McMaster-Carr logo
    Filter by
    Outlet Shape
    System of Measurement
    Inlet Diameter
    Outlet Diameter
    Overall Depth
    Attribute Image
    Wheel Material
    Housing Material
    Wheel Diameter
    Motor Enclosure Type
    Electrical Phase
    Maximum Temperature
    Power Source
    Frequency
    Number of Speeds
    Height
    Volume (Sound) @ Distance
    Industrial Info Snippet
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Overall Height
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    19 Products

    Chemical-Resistant Blowers

    For resistance to chemicals as well as corrosion, these blowers have a plastic housing. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    With Round Outlet and Round Inlet—Totally Enclosed Motor Enclosure
    Image of Product. Front orientation. Blowers. Chemical-Resistant Blowers, Round Outlet.
    Image of Product. Front orientation. Blower Wheels. Chemical-Resistant Blowers.

    Replacement Wheels

    Fiberglass Housing—Fiberglass housing withstands organic chemicals, such as ammonia, antifreeze, and mineral oils.
    Blowers
    Replacement
    Wheels
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Wt.,
    lb.
    Current
    Housing
    Material
    Fasteners
    Included
    Hole
    Dia.
    Each
    Each
    120V AC/230V AC
     
    Single Phase—Hardwire
    810 ft³/min @ 1 in. H₂O
    960 ft³/min @ 1/2 in. H₂O
    Not Rated1,7251/38"8"7"16 3/4"15 1/8"18 1/2"536.0 amp/3.0 ampFiberglassNo3/8"000000000000000000000000000000
     

    Hazardous Location Chemical-Resistant Blowers

    These blowers have an explosion-proof motor that is UL listed and CSA certified for Class I, Divisions 1 and 2, Group D; and Class II, Divisions 1 and 2, Groups F and G hazardous locations. For resistance to chemicals as well as corrosion, they have a plastic housing. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and wet environments.
    Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    With Round Outlet and Round Inlet
    Image of Product. Front orientation. Blowers. Hazardous Location Chemical-Resistant Blowers, Round Outlet.
    Image of Product. Front orientation. Blower Wheels. Hazardous Location Chemical-Resistant Blowers.

    Replacement Wheels

    Fiberglass Housing—Fiberglass housing withstands organic chemicals, such as ammonia, antifreeze, and mineral oils.
    Blowers
    Replacement
    Wheels
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Motor Speed,
    rpm
    Power,
    hp
    Outlet
    Dia.
    Inlet
    Dia.
    Wheel
    Dia.
    Ht.
    Wd.
    Dp.
    Current
    Housing
    Material
    Hazardous Location Rating
    Fasteners
    Included
    Hole
    Dia.
    Each
    Each
    120V AC/230V AC
     
    Single Phase—Hardwire
    810 ft³/min @ 1 in. H₂O
    960 ft³/min @ 1/2 in. H₂O
    Not Rated1,7251/38"8"7"16 3/4"15 1/8"21 1/2"6.0 amp/3.0 ampFiberglassNEC Class I Divisions 1, 2 Group D
    NEC Class II Divisions 1, 2 Groups F, G
    No3/8"000000000000000000000000000000
     

    Wind-Driven Roof-Mount Exhaust Fans

    Image of Product. Front orientation. Contains Annotated. Exhaust Fans. Wind-Driven Roof-Mount Exhaust Fans .
    Designed to spin freely with the slightest breeze, these fans create a vacuum that draws air out from buildings and ventilation systems—no electricity required. They are also known as turbine ventilators. Mount fans on your roof away from wind obstructions.
    Base
    Dia.
    Overall
    Ht.
    Airflow @ Wind
    Speed
    Thk.
    Max. Temp.,
    ° F
    Each
    Galvanized Steel
    10"16 3/4"425 ft³/min @ 4 mph0.018"15000000000000000
     
    Stainless Steel
    10"16 3/4"305 ft³/min @ 4 mph0.018"1500000000000000
     
    Mounting Bases