About Calculating the Airflow Required for Air Cleaning
More
About Air Compressors
More
Office Floor Fans

Tilt the head of these fans to direct air where it's needed.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | No. of Speeds | Current, A | Ht. | Wd. | Dp. | Cord Lg., ft. | Blade Material | Guard Material | Specifications Met | Each | |
120V AC, Single Phase—Three Prong Plug | ||||||||||||
Non-Oscillating, Tilting | ||||||||||||
18" | 3,100 | 3 | 1.5 | 22" | 22" | 10" | 9 | Steel | Steel | ETL Listed | 0000000 | 0000000 |
Wall-Mount Office Fans

Keep cool with these personal-size wall-mount fans. The fan head tilts to direct air where it's needed.
For technical drawings and 3-D models, click on a part number.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | No. of Speeds | Current, A | Ht. | Wd. | Dp. | Cord Lg., ft. | Blade Material | Guard Material | Mount. Fasteners Included | Specifications Met | Each | |
120V AC, Single Phase—Three Prong Plug | |||||||||||||
Oscillating, Tilting | |||||||||||||
16" | 1,700 | 3 | 0.7 | 22" | 18" | 14" | 6 | Plastic | Steel | Yes | ETL Listed | 0000000 | 000000 |
High-Flow Low-Pressure Hazardous Location Compressed Air Blowers

Safely produce high-flow compressed air with low pressure or vacuum in environments with flammable gases and combustible dust, such as propane and carbon-based dust. These blowers have an explosion-proof motor and are UL listed for use in hazardous locations. Also known as regenerative blowers, they are commonly used to operate pump drives, lift tables, and conveying systems. They can also be used for drying, exhausting, and aerating.
For technical drawings and 3-D models, click on a part number.
Overall | Pipe Size | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Pressure | Max. Flow Rate | Vacuum Rating | hp | Full Load Current | Vol., dBA | Lg. | Wd. | Ht. | Temp. Range, °F | Inlet | Outlet | Environmental Rating | Each | |
Three Phase, 208V AC/230V AC/460V AC (Inverter Rated) | ||||||||||||||
NPT Female Inlet and Outlet | ||||||||||||||
2 psi 50 in. of H2O | 556 cfm @ 0 psi | 3.7 in. of Hg 50 in. of H2O | 10 | 24.3 A @ 208 V AC 22.4 A @ 230 V AC 11.2 A @ 460 V AC | 81 | 25" | 20" | 22" | 5° to 100° | 4 | 4 | NEC Class I Division 1 Group D; NEC Class II Division 2 Groups F, G | 0000000 | 000000000 |
2 psi 60 in. of H2O | 471 cfm @ 0 psi | 4.4 in. of Hg 60 in. of H2O | 10 | 24.3 A @ 208 V AC 22.4 A @ 230 V AC 11.2 A @ 460 V AC | 81 | 25" | 19" | 22" | 5° to 100° | 4 | 4 | NEC Class I Division 1 Group D; NEC Class II Division 2 Groups F, G | 0000000 | 00000000 |
Overall | Pipe Size | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Pressure | Max. Flow Rate | Vacuum Rating | hp | Full Load Current | Vol., dBA | Lg. | Wd. | Ht. | Temp. Range, °F | Inlet | Outlet | Environmental Rating | Each | |
Three Phase, 208V AC/230V AC/460V AC (Inverter Rated) | ||||||||||||||
NPT Female Inlet and Outlet | ||||||||||||||
2 psi 115 in. of H2O | 274 cfm @ 0 psi | 8.5 in. of Hg 115 in. of H2O | 10 | 24.3 A @ 208 V AC 22.4 A @ 230 V AC 11.2 A @ 460 V AC | 81 | 27" | 20" | 22" | 5° to 100° | 4 | 4 | NEC Class I Division 1 Group D; NEC Class II Division 2 Groups F, G | 0000000 | 000000000 |
3 psi 110 in. of H2O | 220 cfm @ 0 psi | 8.1 in. of Hg 110 in. of H2O | 7 1/2 | 18.9 A @ 208 V AC 17.8 A @ 230 V AC 8.9 A @ 460 V AC | 78 | 27" | 19" | 22" | 5° to 100° | 4 | 4 | NEC Class I Division 1 Group D; NEC Class II Division 2 Groups F, G | 0000000 | 00000000 |
Fume Hoods

Pair these hoods with an exhaust system to contain harmful fumes, vapors, and gasses while venting them away from work spaces—they protect users from inhaling or coming in contact with them. To access the enclosed space, these hoods have an adjustable sliding window, which also lets your exhaust system pull air from the outside.
Polyethylene hoods have a molded one-piece construction with rounded inside corners to prevent gaps and crevices, making them easy to wipe clean.
Overall | Opening | Windows | Outlets | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Recommended Airflow, cfm | Height | Width | Depth | Height | Width | Number of | Material | Clarity | Number of | OD | Gender | Each | |
Polyethylene Plastic with Adjustable Sliding Window | |||||||||||||
200 | 22" | 27" | 13" | 12" | 22" | 1 | Acrylic Plastic | Clear | 1 | 4", 6" | Male | 00000000 | 0000000 |