    5 Products

    Direct-Drive Wall-Mount Exhaust Fans

    Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
    120V AC, Single Phase (Hardwire)—Open Dripproof (ODP) Motor Enclosure
    Image of Product. Front orientation. Open Dripproof (ODP) Motor Enclosure. Direct-Drive Wall-Mount Exhaust Fans .
    Fans with an open dripproof (ODP) motor enclosure are for relatively clean, dry, indoor locations.
    Exhaust Fan Collars—Use a collar (sold separately) to connect these fans to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Ambient
    Temp., ° F
    Frame Material
    Blade
    Material
    Certification
    Each
    Each
    18"4,20069 dBA @ 5 ft.Direct1,55013/424 1/8"24 1/8"11 3/4"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    0000000000000000000000000000
    20"4,10064 dBA @ 5 ft.Direct1,07511/224 1/8"24 1/8"10 5/8"100Powder-Coated SteelAluminum
    C-UL Listed, UL Listed
    00000000000000000000000000

    Hazardous Location Exhaust Fans

    These fans have a motor that is UL listed for hazardous environments. Use them to draw stagnant and humid air out of a room or area.
    120/230V AC, Single Phase—Hardwire
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Exhaust Fans .
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Add a collar (sold separately) to connect a wall-mount fan these fans to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Blade
    Material
    Certification
    Hazardous Location Rating
    Each
    Each
    20"4,80073 dBA @ 5 ft.Direct1,72511/224 1/8"24 1/8"19 1/2"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    000000000000000000000000000000
    230/460V AC, Three Phase—Hardwire
    Image of Product. Front orientation. Exhaust Fans. Hazardous Location Exhaust Fans .
    Direct Drive—Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Add a collar (sold separately) to connect a wall-mount fan these fans to a louver.
    Exhaust Fans
    Exhaust Fan
    Collars
    Overall
    Blade
    Dia.
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Drive
    Type
    Motor Speed,
    rpm
    No. of
    Speeds
    Power,
    hp
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Blade
    Material
    Certification
    Hazardous Location Rating
    Each
    Each
    20"4,80073 dBA @ 5 ft.Direct1,72511/224 1/8"24 1/8"19 1/2"SteelAluminum
    C-UL Listed, UL Listed
    NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    000000000000000000000000000000
    back to top