    8 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Riser-Rated Fire Alarm Cable

    This FPLR cable is approved for use in vertical shafts and large facilities with multiple levels. It has flame-resistant insulation for use in critical circuits such as fire alarm systems and smoke detectors.
    Unshielded—Use unshielded cable in applications where signal interference is not a concern.
    Shielded—Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Features
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    Unshielded Solid Wire
    Image of Product. Front orientation. Fire Alarm Cable. Riser-Rated Fire Alarm Cable , Unshielded.
     
    300V AC/300V DC
    18
    218/2
    0.13"PVC
    RedPVC
    Black, Red0 to 140FPLR
    ETL Listed
    8435T41
    00000
    000000
    000000
    000000
    000000
    18
    418/4
    0.15"PVC
    RedPVC
    Black, Green, Red, Yellow0 to 140FPLR
    ETL Listed
    8435T43
    00000
    00000
    00000
    00000
     
    Shielded Solid Wire
    Image of Product. Front orientation. Fire Alarm Cable. Riser-Rated Fire Alarm Cable , Shielded.
     
    300V AC/300V DC
    18
    218/2
    0.15"PVC
    RedPVC
    Black, Red0 to 140Uninsulated Ground WireFPLR
    ETL Listed
    8435T42
    0000
    00000
    00000
    00000
     

    Duct-Rated Fire Alarm Cable

    Also known as plenum cable, this FPLP cable has low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. The insulation is also flame resistant for use in critical circuits such as fire alarm systems and smoke detectors.
    Unshielded—Use unshielded cable in applications where signal interference is not a concern.
    Shielded—Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire that is not counted in the number of wires.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Features
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    Unshielded Solid Wire
    Image of Product. Front orientation. Fire Alarm Cable. Duct-Rated Fire Alarm Cable , Unshielded.
     
    300V AC/300V DC
    18
    218/2
    0.15"PVC
    RedPVC
    Black, Red0 to 165FPLP
    UL Listed
    8435T21
    000000
    000000
    000000
    000000
    0000000
    18
    418/4
    0.18"PVC
    RedPVC
    Black, Green, Red, Yellow0 to 165FPLP
    UL Listed
    8435T23
    00000
    00000
    00000
    00000
     
    Shielded Solid Wire
    Image of Product. Front orientation. Fire Alarm Cable. Duct-Rated Fire Alarm Cable , Shielded.
     
    300V AC/300V DC
    18
    218/2
    0.16"PVC
    RedPVC
    Black, Red32 to 165Uninsulated Ground WireFPLP
    UL Listed
    8435T22
    00000
    00000
    00000
    00000
    000000
     

    Armored Fire Alarm Cable

    Image of Product. Side1 orientation. Fire Alarm Cable. Armored Fire Alarm Cable , Unshielded.

    Unshielded

    Image of Product. Side1 orientation. Fire Alarm Cable. Armored Fire Alarm Cable , Shielded.

    Shielded

    Prevent damage to wires for fire alarm systems, smoke detectors, and other critical circuits with this armored cable. Also known as metal clad (MC) cable, the metal armor acts as a conduit to protect the wires inside. The PVC inner insulation resists flames. Its nylon jacket is low smoke, so it can be used without conduit in duct work, under raised floors, and above a drop ceiling. This cable has a ground wire that is not counted in the number of wires.
    Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it’s rated for your environment.
    Shielded—Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Features
    Armored
    Cable Type
    Hazardous Location Rating
    Certification
    Flammability
    Rating
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    Unshielded Solid Wire
     
    300V AC/300V DC
    18
    418/4
    0.43"Aluminum
    RedNylon, PVC
    Black, Blue, Green, Red, White-10 to 190Insulated Ground WireMC-FPLPNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Division 2
    UL Listed
    UL 2556 VW-1
    6123N12
    000000
    000000
    000000
    0000000
    0000000
     
    Shielded Solid Wire
     
    300V AC/300V DC
    18
    218/2
    0.39"Aluminum
    RedNylon, PVC
    Black, White-10 to 190Uninsulated Ground WireMC-FPLPNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Division 2
    UL Listed
    UL 2556 VW-1
    6123N11
    00000
    00000
    00000
    00000
    000000
     