Fire Sprinkler Heads




Sprinkler heads must be installed and maintained according to National Fire Protection Association (NFPA) standards. Install using sprinkler-head wrenches (sold separately) or any hand wrench that fits the NPT size.
Pendent-style sprinkler heads are designed to be suspended below support piping. They can be used with exposed piping or finished ceilings.
Upright-style sprinkler heads are designed to be installed above support piping and can only be used with exposed piping.
Glass-bulb sprinkler heads are triggered when the liquid-filled bulb bursts at the rated temperature.
Fusible-link sprinkler heads are triggered by a soft metal alloy that melts at the rated temperature.
Temperature | ||||||||
|---|---|---|---|---|---|---|---|---|
| Rating, ° F | Color Code | Max. Pressure, psi | Material | Specifications Met | Choose a Style | Flow Rate | Each | |
1/2 NPT Male Connection | ||||||||
Glass Bulb | ||||||||
| 155° | Red | 175 | Brass | FM Approved, UL Listed | 74 gpm @ 175 psi | 00000000 | 000000 | |
| 175° | Yellow | 175 | Brass | FM Approved, UL Listed | 74 gpm @ 175 psi | 00000000 | 00000 | |
| 200° | Green | 175 | Brass | FM Approved, UL Listed | 74 gpm @ 175 psi | 00000000 | 00000 | |
| 286° | Blue | 175 | Brass | FM Approved, UL Listed | 74 gpm @ 175 psi | 00000000 | 00000 | |
| 360° | Purple | 175 | Brass | FM Approved, UL Listed | 74 gpm @ 175 psi | 00000000 | 00000 | |
Fusible Link | ||||||||
| 165° | __ | 175 | Brass | FM Approved, UL Listed | 74 gpm @ 175 psi | 0000000 | 00000 | |
| 212° | White | 175 | Brass | FM Approved, UL Listed | 74 gpm @ 175 psi | 0000000 | 00000 | |
| 280° | Blue | 175 | Brass | FM Approved, UL Listed | 74 gpm @ 175 psi | 0000000 | 00000 | |
3/4 NPT Male Connection | ||||||||
Glass Bulb | ||||||||
| 155° | Red | 175 | Brass | FM Approved, UL Listed | 105 gpm @ 175 psi | 00000000 | 00000 | |
| 175° | Yellow | 175 | Brass | FM Approved, UL Listed | 105 gpm @ 175 psi | 00000000 | 00000 | |
| 200° | Green | 175 | Brass | FM Approved, UL Listed | 105 gpm @ 175 psi | 00000000 | 00000 | |
| 286° | Blue | 175 | Brass | FM Approved, UL Listed | 105 gpm @ 175 psi | 00000000 | 00000 | |
| 360° | Purple | 175 | Brass | FM Approved, UL Listed | 105 gpm @ 175 psi | 00000000 | 00000 | |
Fusible Link | ||||||||
| 165° | __ | 175 | Brass | FM Approved, UL Listed | Upright | 105 gpm @ 175 psi | 00000000 | 00000 |
| 212° | White | 175 | Brass | FM Approved, UL Listed | Upright | 105 gpm @ 175 psi | 00000000 | 00000 |
| 280° | Blue | 175 | Brass | FM Approved, UL Listed | Upright | 105 gpm @ 175 psi | 00000000 | 00000 |
Quick-Response Fire Sprinkler Heads


These sprinkler heads react to heat up to five times faster than other sprinkler heads. They are triggered when the liquid-filled bulb bursts at the rated temperature. Heads must be installed and maintained according to National Fire Protection Association (NFPA) standards. Install using sprinkler-head wrenches (sold separately) or any hand wrench that fits the NPT size.
Pendent-style sprinkler heads are designed to be suspended below support piping. They can be used with exposed piping or finished ceilings.
Upright-style sprinkler heads are designed to be installed above support piping and can only be used with exposed piping.
Temperature | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Rating, ° F | Color Code | Max. Pressure, psi | Material | Specifications Met | Choose a Style | Gender | Flow Rate | Each | |
1/2 NPT Male Connection | |||||||||
| 155° | Red | 175 | Brass | FM Approved, UL Listed | Male | 74 gpm @ 175 psi | 0000000 | 000000 | |
| 175° | Yellow | 175 | Brass | FM Approved, UL Listed | Male | 74 gpm @ 175 psi | 0000000 | 00000 | |
| 200° | Green | 175 | Brass | FM Approved, UL Listed | Male | 74 gpm @ 175 psi | 0000000 | 00000 | |
| 286° | Blue | 175 | Brass | FM Approved, UL Listed | Male | 74 gpm @ 175 psi | 0000000 | 00000 | |
3/4 NPT Male Connection | |||||||||
| 155° | Red | 175 | Brass | FM Approved, UL Listed | Male | 105 gpm @ 175 psi | 0000000 | 00000 | |
| 175° | Yellow | 175 | Brass | FM Approved, UL Listed | Male | 105 gpm @ 175 psi | 0000000 | 00000 | |
| 200° | Green | 175 | Brass | FM Approved, UL Listed | Male | 105 gpm @ 175 psi | 0000000 | 00000 | |
| 286° | Blue | 175 | Brass | FM Approved, UL Listed | Male | 105 gpm @ 175 psi | 0000000 | 00000 | |
| Wrench for Sprinkler Heads | 0000000 | Each | 0000000 |
Adjustable-Depth Two-Piece Cover Plates for Fire Sprinkler Heads


Snap these two-piece covers around existing sprinkler heads without having to disassemble or drain the system. Also known as escutcheons, they give your sprinkler heads a clean look.
Chrome-Plated Steel | White Painted Steel | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| Dp. Range | For Sprinkler Head Style | For Pipe Size | For Thread Type | ID | OD | Each | Each | ||
| 1/4"-1 5/8" | Pendent | 1/2 | NPT | 3/4" | 3 3/4" | 000000 | 000000 | 000000 | 00 |
| 3/4"-1 7/8" | Pendent | 1/2 | NPT | 3/4" | 3 3/4" | 000000 | 00000 | 000000 | 00 |
| 2"-3" | Pendent | 1/2 | NPT | 3/4" | 3 1/2" | 000000 | 0000 | 0000000 | 000000 |
| 3"-4" | Pendent | 1/2 | NPT | 3/4" | 4 1/2" | 000000 | 00000 | 0000000 | 00000 |
| 3"-5" | Pendent | 1/2 | NPT | 3/4" | 4 1/2" | 0000000 | 00000 | 0000000 | 00000 |
Two-Piece Cover Plates for Fire Sprinkler Heads

Snap these two-piece covers around existing sprinkler heads without having to disassemble or drain the system. Also known as escutcheons, they give your sprinkler heads a clean look.
Cover Plates for Fire Sprinkler Heads

Install this cover at the same time as a new sprinkler head. Also known as an escutcheon, it gives your sprinkler head a clean look.
| For Sprinkler Head Style | For Pipe Size | For Thread Type | Material | Dp. Range | ID | OD | Each | |
| Pendent | 1/2 | NPT | Chrome-Plated Steel | 2"-3" | 3/4" | 3 1/2" | 000000 | 000000 |
Recessed Fire Sprinkler Heads


Use these sprinkler heads for low-profile fire safety. Install using required wrenches (sold separately).
Glass-bulb sprinkler heads are triggered when the liquid-filled bulb bursts at the rated temperature.
Fusible-link sprinkler heads are triggered by a soft metal alloy that melts at the rated temperature.
1/2 NPT Male Connection | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature | Cover Plates | Required Wrenches | |||||||||||
| Rating, °F | Color Code | Flow Rate | Max. Pressure, psi | Recess Dia. | Recess Dp. | Material | Specifications Met | Each | Each | Each | |||
Glass Bulb | |||||||||||||
| 155° | Red | 74 gpm @ 175 psi | 175 | 1 15/16" | 1" | Chrome-Plated Bronze | FM Approved, UL Listed | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 0000000 |
| 175° | Yellow | 74 gpm @ 175 psi | 175 | 1 15/16" | 1" | Chrome-Plated Bronze | FM Approved, UL Listed | 00000000 | 00000 | 00000000 | 0000 | 00000000 | 000000 |
| 200° | Green | 74 gpm @ 175 psi | 175 | 1 15/16" | 1" | Chrome-Plated Bronze | FM Approved, UL Listed | 00000000 | 00000 | 00000000 | 0000 | 00000000 | 000000 |
Fusible Link | |||||||||||||
| 165° | __ | 74 gpm @ 175 psi | 175 | 1 15/16" | 1" | Chrome-Plated Bronze | FM Approved, UL Listed | 00000000 | 00000 | 00000000 | 0000 | 00000000 | 000000 |
| 212° | White | 74 gpm @ 175 psi | 175 | 1 15/16" | 1" | Chrome-Plated Bronze | FM Approved, UL Listed | 00000000 | 00000 | 00000000 | 0000 | 00000000 | 000000 |
Concealed Fire Sprinkler Heads

An inconspicuous cover plate provides a clean look for sprinkler heads. When the plate's temperature rating is reached, it falls away to expose the sprinkler head. The head itself has a liquid-filled glass bulb that bursts at the rated temperature to trigger the sprinkler. Install using required wrenches (sold separately).
1/2 NPT Male Connection | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature | Cover Plates | Required Wrenches | ||||||||||
| Plate Temperature Rating, ° F | Plate Color | Rating, °F | Color Code | Flow Rate | Specifications Met | Sprinkler Head Style | Each | Each | Each | |||
| 139° | Chrome | 155° | Red | 74 gpm @ 175 psi | FM Approved, UL Listed | Pendent | 00000000 | 000000 | 00000000 | 000000 | 0000000 | 0000000 |
| 139° | White | 155° | Red | 74 gpm @ 175 psi | FM Approved, UL Listed | Pendent | 00000000 | 00000 | 00000000 | 00000 | 0000000 | 000000 |
| 165° | Chrome | 200° | Green | 74 gpm @ 175 psi | FM Approved, UL Listed | Pendent | 00000000 | 00000 | 00000000 | 00000 | 0000000 | 000000 |
| 165° | White | 200° | Green | 74 gpm @ 175 psi | FM Approved, UL Listed | Pendent | 00000000 | 00000 | 00000000 | 00000 | 0000000 | 000000 |
Fire Sprinkler Head Stoppers

Prevent water from spraying without having to shut down the entire sprinkler system. To reach the sprinkler head, insert any 3/4" to 1" dia. pole (not included) into the stopper base.
| For Sprinkler Head Style | Base ID | Each | |
| Pendent, Upright | 1" | 0000000 | 000000 |