    Panel-Mount Flowmeters for Gases

    Monitor the flow rate of air and other gases from your instrument panel—these flowmeters have fittings on the back for panel mounting. They should be mounted vertically inline with your piping system, so gas flows up from the bottom. As gas passes through, it pushes an indicator up the scale, showing you the flow rate. With an acrylic body, they're completely clear, so you can inspect your gas’s color and clarity for any problems.
    These flowmeters are calibrated with air but can be used with other gases. If you’re using these with a gas other than air, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your gas.
    Choose a fitting material that is compatible with the gas you're running through your line.
    Flowmeters
    Image of Product. Front orientation. Contains Annotated. Flowmeters. Panel-Mount Flowmeters for Gases, Flowmeters.
    Image of Product. Front orientation. Flowmeter Repair Kits. Panel-Mount Flowmeters for Gases.

    Replacement Flowmeter

    Repair Kits

    PVC Fitting—PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Brass Fitting—Brass fittings resist impact better than PVC fittings.
    Calibration Certificate Traceable to NIST—Flowmeters with a calibration certificate traceable to NIST states that the flowmeter has passed a test for accuracy.
    Flowmeters
    Replacement
    Flowmeter Repair Kits
    Temp.,
    ° F
    Calibration
    Certificate Traceable to NIST
    Flow
    Overall
    Ht.
    Ctr.-to-Ctr.
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Each
    Each
    Acrylic Plastic Body with PVC Fittings
     
    1/2 NPT Female
    2 scfm to 20 scfm14 1/2"12 1/4"±2%100 psi @ 70° F33100EPM RubberVertical3281K10700000006766T22000000
    4.2 scfm to 42 scfm14 1/2"12 1/4"±2%100 psi @ 70° F33100EPM RubberVertical3281K1080000006766T2200000
     
    1 NPT Male
    4 scfm to 40 scfm9 1/8"6.437"±4%100 psi @ 70° F33100EPM RubberVertical3281K1090000006766T2100000
    6 scfm to 60 scfm9 1/8"6.437"±4%100 psi @ 70° F33100EPM RubberVertical3281K1110000006766T2100000
     
    Acrylic Plastic Body with Brass Fittings
     
    1/4 NPT Female
    2 scfh to 20 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K240000006766T1800000
    3 scfh to 30 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K1010000006766T1800000
    6 scfh to 60 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K250000006766T1800000
    10 scfh to 100 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K1020000006766T1800000
    15 scfh to 180 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K1030000006766T1800000
    0.4 scfm to 4 scfm4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K260000006766T1800000
     
    Flowmeters with Flow-Control Knob
    Image of Product. Front orientation. Contains Annotated. Flowmeters. Panel-Mount Flowmeters for Gases, Flowmeters with Flow-Control Knob.
    Image of Product. Front orientation. Flowmeter Repair Kits. Panel-Mount Flowmeters for Gases.

    Replacement Flowmeter

    Repair Kits

    Flowmeters with a flow-control knob let you open and close the valve at the inlet to adjust the flow rate within the range.
    PVC Fitting—PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Brass Fitting—Brass fittings resist impact better than PVC fittings.
    316 Stainless Steel Fitting—316 stainless steel fittings resist impact better than PVC fittings.
    1/4 NPT Threaded Female Pipe × 1/2 NPT Threaded Male Pipe—Flowmeters with a female × male connection have internal NPT female threads and external NPT male threads.
    Calibration Certificate Traceable to NIST—Flowmeters with a calibration certificate traceable to NIST states that the flowmeter has passed a test for accuracy.
    Flowmeters
    Replacement
    Flowmeter Repair Kits
    Temp.,
    ° F
    Calibration
    Certificate Traceable to NIST
    Flow
    Overall
    Ht.
    Ctr.-to-Ctr.
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Each
    Each
    Acrylic Plastic Body with PVC Fittings
     
    1 NPT Male
    4 scfm to 40 scfm9 1/8"6.437"±4%100 psi @ 70° F33100EPM RubberVertical3281K11800000006766T25000000
    6 scfm to 60 scfm9 1/8"6.437"±4%100 psi @ 70° F33100EPM RubberVertical3281K1190000006766T2500000
     
    Acrylic Plastic Body with Brass Fittings
     
    1/4 NPT Female
    2 scfh to 20 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K340000006766T2300000
    3 scfh to 30 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K1040000006766T2300000
    6 scfh to 60 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K350000006766T2300000
    10 scfh to 100 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K1050000006766T2300000
    15 scfh to 180 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K1060000006766T2300000
    0.4 scfm to 4 scfm4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K360000006766T2300000
     
    Acrylic Plastic Body with 316 Stainless Steel Fittings
     
    1/4 NPT Female
    2 scfh to 20 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K440000006766T2300000
    3 scfh to 30 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K1340000006766T2300000
    6 scfh to 60 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K450000006766T2300000
    10 scfh to 100 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K1350000006766T2300000
    15 scfh to 180 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K1360000006766T2300000
    0.4 scfm to 4 scfm4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical3281K460000006766T2300000
     
    1/4 NPT Threaded Female Pipe × 1/2 NPT Threaded Male Pipe
    0.8 scfm to 8.2 scfm6 7/8"5"±4%100 psi @ 70° F33100EPM RubberVertical3281K1330000006766T2400000
    2.3 scfm to 23 scfm6 7/8"5"±4%100 psi @ 70° F33100EPM RubberVertical3281K1290000006766T2400000
     
    1/2 NPT Female
    2 scfm to 20 scfm14 1/2"12 1/4"±2%100 psi @ 70° F33100EPM RubberVertical3281K1250000006766T2600000
    4.2 scfm to 42 scfm14 1/2"12 1/4"±2%100 psi @ 70° F33100EPM RubberVertical3281K1260000006766T2600000
     

    Flowmeter/Totalizers

    Determine the flow rate and total volume of liquid flowing through your system with the same meter. To measure flow, these flowmeter/totalizers count how many times their turbine turns as liquid passes through. Use them only with clean, low-viscosity liquids to avoid clogging the turbine and other damage to these flowmeter/totalizers. You can reset the batch total, but you can’t reset the cumulative total. Mount them inline with your pipe system. They’re accurate in any mounting orientation.
    These flowmeter/totalizers are either calibrated with water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Choose a fitting material that is compatible with the liquid you're running through your line. IP rated, all seal out dust and can be lightly rinsed.
    PVC Body with PVC Fittings and 316 Stainless Steel Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, PVC Body.
    Image of Product. Shown with 90° Display Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers, PVC Body.

    Shown with 90°

    Display Adapter Kit

    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flowmeter/Totalizers.

    Replacement Displays

    Image of Product. Front orientation. Flowmeter Rotors. Flowmeter/Totalizers.

    Replacement Flowmeter Rotors

    PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    NEMA 4 Enclosure Rating—NEMA 4 flowmeter/totalizers protect against weather and washdowns.
    Flowmeter/Totalizers
    Replacement Displays
    Replacement
    Flowmeter Rotors
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Each
    Display
    Type
    Each
    Each
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    1/2 NPT Female1 to 1080
    6"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T4310000000Digital4352K5130000000———0
    3/4 NPT Female2 to 2080
    6 1/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T441000000Digital4352K523000000———0
    1 NPT Female5 to 5080
    6 1/2"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T451000000Digital4352K533000000———0
    1 1/2 NPT Female10 to 10080
    7 5/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T461000000Digital4352K543000000———0
    2 NPT Female20 to 20080
    7 7/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T471000000Digital4352K553000000———0
    4 NPT Female60 to 60080
    17"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T49100000000Digital4352K1090000004352K1120000000
     
    Accessories for Flowmeters
    Nylon Body with Nylon Fittings and 316 Stainless Steel Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, Nylon Body, Nylon Fitting.
    Image of Product. Shown with 90° Display Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers, Nylon Body, Nylon Fitting.

    Shown with 90°

    Display Adapter Kit

    Nylon fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    NEMA 4 Enclosure Rating—NEMA 4 flowmeter/totalizers protect against weather and washdowns.
    FM Approved—FM-approved flowmeter/totalizers are safe for use in hazardous location.
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    1 NPT Female0.3 to 380
    4"±1.5%999,999 Gallons999,999 Gallons150 psi @ 70° F14140YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx Ia IIC T4
    FM Approved
    4352K2320000000
     
    Accessories for Flowmeters
    PVDF Body with PVDF Fittings and Fluoroelastomer Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, PVDF Body.
    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flowmeter/Totalizers.

    Replacement Displays

    Image of Product. Front orientation. Flowmeter Rotors. Flowmeter/Totalizers.

    Replacement Flowmeter Rotors

    PVDF fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    NEMA 4 Enclosure Rating—NEMA 4 flowmeter/totalizers protect against weather and washdowns.
    FM Approved—FM-approved flowmeter/totalizers are safe for use in hazardous location.
    Flowmeter/Totalizers
    Replacement Displays
    Replacement
    Flowmeter Rotors
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    Display
    Type
    Each
    Each
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    1/2 NPT Female1.2 to 1280
    7 5/16"±2%999,999 Gallons999,999 Gallons100 psi @ 70° F0125YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    AEx Ia IIC T4
    FM Approved
    4352K103000000000Digital4352K51300000004352K1040000000
     
    Accessories for Flowmeters
    316 Stainless Steel Body with 316 Stainless Steel Fittings and 316 Stainless Steel Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, 316 Stainless Steel Body.
    Image of Product. Shown with 90° Display Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers, 316 Stainless Steel Body.
    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flowmeter/Totalizers.

    Shown with 90°

    Display Adapter Kit

    Replacement Displays

    316 stainless steel fittings resist impact better than plastic fittings.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    FM Approved—FM-approved flowmeter/totalizers are safe for use in hazardous location.
    Flowmeter/Totalizers
    Replacement Displays
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    Display
    Type
    Each
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    1/2 NPT Female1 to 104 1/4"±1.5%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K852000000000Digital4352K5130000000
    3/4 NPT Female2 to 204 3/8"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K86200000000Digital4352K523000000
    1 NPT Female5 to 504 1/2"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K87200000000Digital4352K533000000
    1 1/2 NPT Female10 to 1005 3/8"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K88200000000Digital4352K543000000
    2 NPT Female20 to 2006 3/8"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K89200000000Digital4352K553000000
     
    Accessories for Flowmeters

    Compression Tube Flow Transmitters for Gases

    Image of Product. Front orientation. Flow Transmitters. Compression Tube Flow Transmitters for Gases.
    Commonly referred to as thermal mass flowmeters, these transmitters calculate flow rate by measuring how much they cool as air and other gases pass through them. This means they’re accurate even if there are temperature and pressure changes, unlike most other transmitters. Used to monitor flow or control equipment, these transmitters, also known as transducers, convert measurements to an electrical signal that is interpreted by receiving devices. As flow increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. A digital display makes it easy to check the flow rate and adjust settings. Mount these transmitters inline with your system.
    These transmitters are calibrated with air. You can use them with other gases, but they will not be as accurate.
    Adapters—Voltage adapters are required to connect these transmitters to a power source.
    Flow Transmitters
    Adapters
    For Tube
    OD
    Flow Range,
    L/min
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Seal Material
    Input Voltage
    Range, V DC
    Mounting
    Position
    Each
    Each
    One 4-20 mA Analog Transmitter Output—2.1 mm Plug End ID Barrel Connection/DB9 Connection Plug
     
    Aluminum Body with Brass Fitting
    1/4"0 to 0.015 1/8"±1.0%1,000 psi @ 70° F32 to 122Viton® Fluoroelastomer
    12 to 26Horizontal9365K66000000070235K4900000
    1/4"0 to 0.055 1/8"±1.0%1,000 psi @ 70° F32 to 122Viton® Fluoroelastomer
    12 to 26Horizontal9365K6700000070235K490000
    1/4"0 to 0.15 1/8"±1.0%1,000 psi @ 70° F32 to 122Viton® Fluoroelastomer
    12 to 26Horizontal9365K6800000070235K490000
    1/4"0 to 0.55 1/8"±1.0%1,000 psi @ 70° F32 to 122Viton® Fluoroelastomer
    12 to 26Horizontal9365K6900000070235K490000
    1/4"0 to 15 1/8"±1.0%1,000 psi @ 70° F32 to 122Viton® Fluoroelastomer
    12 to 26Horizontal9365K7100000070235K490000
    1/4"0 to 55 1/8"±1.0%1,000 psi @ 70° F32 to 122Viton® Fluoroelastomer
    12 to 26Horizontal9365K7200000070235K490000
    1/4"0 to 105 1/8"±1.0%1,000 psi @ 70° F32 to 122Viton® Fluoroelastomer
    12 to 26Horizontal9365K7300000070235K490000
    1/4"0 to 506 3/16"±1.0%1,000 psi @ 70° F32 to 122Viton® Fluoroelastomer
    12 to 26Horizontal9365K740000000070235K490000
    3/8"0 to 1006 1/4"±1.0%1,000 psi @ 70° F32 to 122Viton® Fluoroelastomer
    12 to 26Horizontal9365K750000000070235K490000
     

    Panel-Mount Flowmeters

    Fittings on the back let you install these flowmeters in instrument panels. Mount them vertically inline with your piping system, so liquid flows up from the bottom. As liquid passes through, it pushes an indicator up the scale, showing you the flow rate. With an acrylic body, they're completely clear, so you can inspect your liquid's color and clarity for any problems.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    Flowmeters
    Image of Product. Front orientation. Contains Annotated. Flowmeters. Panel-Mount Flowmeters, Flowmeters.
    Image of Product. Front orientation. Flowmeter Repair Kits. Panel-Mount Flowmeters.

    Replacement Flowmeter

    Repair Kits

    PVC Fitting—PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Brass Fitting—Brass fittings resist impact better than PVC fittings.
    Calibration Certificate Traceable to NIST—Flowmeters with a calibration certificate traceable to NIST states that the flowmeter has passed a test for accuracy.
    Flowmeters
    Replacement
    Flowmeter Repair Kits
    Temp.,
    ° F
    Calibration
    Certificate Traceable to NIST
    Flow
    Overall
    Ht.
    Ctr.-to-Ctr.
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Each
    Each
    Acrylic Plastic Body with PVC Fittings
     
    1/2 NPT Female
    0.5 gpm to 5 gpm14 1/2"12 1/4"±2%125 psi @ 70° F33130EPM RubberVertical3281K230000000———0
     
    Acrylic Plastic Body with Brass Fittings
     
    1/4 NPT Female
    0.7 gph to 7 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical3281K210000006766T18000000
    2.2 gph to 22 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical3281K220000006766T1800000
     
    Flowmeters with Flow-Control Knob
    Image of Product. Front orientation. Contains Annotated. Flowmeters. Panel-Mount Flowmeters, Flowmeters with Flow-Control Knob.
    Image of Product. Front orientation. Flowmeter Repair Kits. Panel-Mount Flowmeters.

    Replacement Flowmeter

    Repair Kits

    Flowmeters with a flow-control knob let you open and close the valve at the inlet to adjust the flow rate within the range.
    PVC Fitting—PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Brass Fitting—Brass fittings resist impact better than PVC fittings.
    303 Stainless Steel Fitting—303 stainless steel fittings resist impact better than PVC fittings.
    316 Stainless Steel Fitting—316 stainless steel fittings resist impact better than PVC fittings.
    Calibration Certificate Traceable to NIST—Flowmeters with a calibration certificate traceable to NIST states that the flowmeter has passed a test for accuracy.
    Flowmeters
    Replacement
    Flowmeter Repair Kits
    Temp.,
    ° F
    Calibration
    Certificate Traceable to NIST
    Flow
    Overall
    Ht.
    Ctr.-to-Ctr.
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Each
    Each
    Acrylic Plastic Body with PVC Fittings
     
    1/2 NPT Female
    0.5 gpm to 5 gpm14 1/2"12 1/4"±2%125 psi @ 70° F33130EPM RubberVertical3281K3300000006766T26000000
     
    Acrylic Plastic Body with Brass Fittings
     
    1/4 NPT Female
    0.7 gph to 7 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical3281K310000006766T2300000
    2.2 gph to 22 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical3281K320000006766T2300000
     
    Acrylic Plastic Body with 303 Stainless Steel Fittings
     
    1/8 NPT Female
    1 gph to 10 gph6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K406000000———0
    2 gph to 25 gph6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K531000000———0
    6 gph to 60 gph6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K845000000———0
    4 cm³/min to 50 cm³/min6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K375000000———0
    40 cm³/min to 400 cm³/min6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K378000000———0
    200 cm³/min to 3,000 cm³/min6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K387000000———0
     
    1/4 NPT Female
    1 L/min to 10 L/min6 5/8"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K352000000———0
    2 L/min to 20 L/min6 5/8"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K357000000———0
     
    1 NPT Female
    0.6 gpm to 5 gpm10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K336000000———0
    1.5 gpm to 10 gpm10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K337000000———0
    3 gpm to 20 gpm10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K339000000———0
     
    Acrylic Plastic Body with 316 Stainless Steel Fittings
     
    1/4 NPT Female
    0.7 gph to 7 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical3281K410000006766T2300000
    2.2 gph to 22 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical3281K420000006766T2300000
     
    1/2 NPT Female
    0.5 gpm to 5 gpm14 1/2"12 1/4"±2%125 psi @ 70° F33130EPM RubberVertical3281K430000006766T2600000
     

    Flowmeters

    Check the flow rate of liquids in your system. As your liquid flows through these flowmeters, it pushes an indicator up the scale, showing you the flow rate. Mount them vertically inline with your piping system, so liquid flows up from the bottom. They’re made from acrylic, so they’re completely clear to help you inspect your liquid’s color and clarity for any problems. They also have a white backing to help you read the scale clearly.
    These flowmeters are calibrated with water but can be used with other liquids except for oil. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    Cylindrical Body
    Image of Product. Front orientation. Flowmeters. Flowmeters, Cylindrical Body, Female.
    Image of Product. Front orientation. Flowmeters. Flowmeters, Cylindrical Body, Male.
    Image of Product. Front orientation. Flowmeter Mounting Fittings. Flowmeters.
    Image of Product. Front orientation. Flowmeter Repair Kits. Flowmeters.

    Female

    Male

    Replacement

    Straights

    Replacement

    Flowmeter Repair

    Kits

    PVC Fitting—PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Brass Fitting—Brass fittings resist impact better than polypropylene and PVC fittings.
    Calibration Certificate Traceable to NIST—Flowmeters with a calibration certificate traceable to NIST states that the flowmeter has passed a test for accuracy.
    Flowmeters
    Replacement
    Straights
    Replacement
    Flowmeter Repair Kits
    Temp.,
    ° F
    Calibration
    Certificate Traceable to NIST
    Flow, gpm
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Each
    Each
    Each
    Acrylic Plastic Body with PVC Fittings
     
    1 1/2 NPT Male
    4 to 4012 1/16"±6%125 psi @ 70° F33130EPM RubberVertical8051K81600000008051K2460000006766T12000000
    5 to 5012 1/16"±6%125 psi @ 70° F33130EPM RubberVertical8051K8170000008051K246000006766T1200000
     
    Acrylic Plastic Body with Brass Fittings
     
    3/8 NPT Female
    0.1 to 18 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K9620000008051K249000006766T30100000
    0.2 to 28 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K9650000008051K249000006766T30100000
    0.3 to 3.58 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K9680000008051K249000006766T30100000
    0.5 to 58 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K9720000008051K249000006766T30100000
     
    Rectangular Body
    Image of Product. Front orientation. Flowmeters. Flowmeters, Rectangular Body, Female.
    Image of Product. Front orientation. Flowmeter Mounting Fittings. Flowmeters.
    Image of Product. Front orientation. Flowmeter Repair Kits. Flowmeters.

    Female

    Replacement

    Straights

    Replacement

    Flowmeter Repair

    Kits

    Flowmeters with a rectangular body are made from a single block of acrylic, so they’re more durable and resist impact better than flowmeters with a cylindrical body. However, they’re not as durable as flowmeters with a protective case.
    PVC Fitting—PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Calibration Certificate Traceable to NIST—Flowmeters with a calibration certificate traceable to NIST states that the flowmeter has passed a test for accuracy.
    Flowmeters
    Replacement
    Straights
    Replacement
    Flowmeter Repair Kits
    Temp.,
    ° F
    Calibration
    Certificate Traceable to NIST
    Flow, gpm
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Each
    Each
    Each
    Acrylic Plastic Body with PVC Fittings
     
    1/2 NPT Female
    0.2 to 29 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K80300000008051K243000000———0
    0.35 to 3.59 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K9470000008051K24300000———0
    0.5 to 59 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K8040000008051K24300000———0
     
    3/4 NPT Female
    0.5 to 514 13/16"±2%125 psi @ 70° F33130EPM RubberVertical8051K8050000008051K244000006766T16000000
    1 to 1014 13/16"±2%125 psi @ 70° F33130EPM RubberVertical8051K8060000008051K244000006766T1600000
     

    Flowmeter/Totalizers with Sanitary Quick-Clamp Fittings

    Image of Product. Shown with 90° Display
Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers with Sanitary Quick-Clamp Fittings.
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers with Sanitary Quick-Clamp Fittings.

    Shown with 90°

    Display Adapter Kit

    Image of Product. Front orientation. Flowmeter Displays. Flowmeter/Totalizers with Sanitary Quick-Clamp Fittings, Digital Display.

    Replacement Displays

    Easy to remove for cleaning and maintenance, these flowmeter/totalizers connect to sanitary quick-clamp fittings (often called tri-clamp fittings) and measure the flow rate and volume of liquid passing through your system. You'll need a gasket and clamp to connect these to your line. They count how many times their turbine turns as liquid passes through to measure flow. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. You can reset the batch total, but you can't reset the cumulative total. Mount them directly inline with your piping system. They measure flow correctly no matter the mounting orientation.
    For use in hazardous locations, these flowmeter/totalizers are FM-approved. They’re also rated NEMA 4 to protect against weather and washdowns.
    These flowmeter/totalizers are calibrated with either water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    Flowmeter/Totalizers
    Replacement Displays
    Flowmeter/Totalizers with Calibration
    Certificate Traceable to NIST
    Max. Volume
    Displayed
    Temp., ° F
    For Tube
    OD
    Connections
    Flow,
    gpm
    Flange
    OD
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Enclosure
    Rating
    Min.
    Max.
    Each
    Display
    Type
    Each
    Turbine Flow Measurement
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    3/4"Female1 to 100.984"5"±1.5%999,999 Gallons999,999 Gallons1,500 psi @ 70° FAny AngleYesIP65
    NEMA 4
    141409011N21000000000Digital9011N4110000000
    1"Female2 to 201.984"5"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° FAny AngleYesIP65
    NEMA 4
    141409011N2200000000Digital9011N412000000
    1 1/2"Female5 to 501.984"5 1/2"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° FAny AngleYesIP65
    NEMA 4
    141409011N2300000000Digital9011N413000000
    2"Female10 to 1002.515"6 1/2"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° FAny AngleYesIP65
    NEMA 4
    141409011N2400000000Digital9011N414000000
    2 1/2"Female20 to 2003.047"7"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° FAny AngleYesIP65
    NEMA 4
    141409011N2500000000Digital9011N415000000
     
    Accessories for Flowmeters

    Flowmeter/Totalizers for Oil and Fuel

    Image of ProductInUse. Shown with 90° Display
Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers for Oil and Fuel.

    Shown with 90°

    Display Adapter Kit

    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers for Oil and Fuel.
    Image of Product. Front orientation. Flowmeter Displays. Flowmeter/Totalizers for Oil and Fuel, Digital Display.

    Replacement Displays

    Image of Product. Front orientation. Flowmeter Rotors. Flowmeter/Totalizers for Oil and Fuel.

    Replacement Flowmeter

    Rotors

    Use these flowmeter/totalizers to measure both the flow rate and total flow volume of oil, gasoline, diesel fuel, and kerosene. They count how many times their turbine turns as liquid passes through them to measure flow. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. You can reset the batch total, but you can't reset the cumulative total. Mount them directly inline with your piping system. They measure flow correctly no matter the mounting orientation. Rated NEMA 4 and IP65, they seal out dust and protect against washdowns.
    These flowmeter/totalizers are calibrated with either water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    Flowmeter/Totalizers
    Replacement Displays
    Replacement
    Flowmeter Rotors
    Flowmeter/Totalizers with Calibration
    Certificate Traceable to NIST
    Max. Volume
    Displayed
    Temp., ° F
    Connections
    Flow,
    gpm
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Enclosure
    Rating
    Min.
    Max.
    Each
    Display
    Type
    Each
    Each
    Turbine Flow Measurement
     
    Aluminum Body with Aluminum Fitting and 316 Stainless Steel Seal
    1/2 NPT Female1 to 104 3/16"±2%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    01254352K202000000000Digital4352K51300000004352K6650000000
    3/4 NPT Female2 to 204 5/16"±1.5%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    01254352K20400000000Digital4352K5230000004352K666000000
    1 NPT Female0.3 to 34"±5%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    141404352K912000000———0———0
    1 NPT Female3 to 504"±1.5%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    141404352K922000000———0———0
    1 1/2 NPT Female10 to 1005 5/16"±1%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    01254352K20600000000Digital4352K5430000004352K668000000
    2 NPT Female20 to 2006"±0.75%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    141404352K4200000000Digital4352K4000000———0
     
    Accessories for Flowmeters

    Remote-Reading Airflow/Temperature Meters

    With a probe on a cord, these meters access hard-to-reach places in duct. They display airflow and temperature simultaneously and can show airflow measurements on multiple scales, such as fpm, mph, and knots. Also known as anemometers.
    Fan
    Image of Product. Front orientation. Airflow Meters. Remote-Reading Airflow/Temperature Meters, Fan.
    Fan meters are also known as vane meters. Those with a built-in surface temperature thermometer also measure the temperature of hard-to-reach surfaces.
    Overall
    Airflow Speed
    Temperature
    Range
    Display
    Type
    Max. Air Volume,
    ft³/min
    Ht.
    Wd.
    Dp.
    Probe Cable
    Lg., ft.
    Batteries
    Included
    Includes
    Each
    Measures Airflow, Temperature, and Air Volume, —With Calibration Certificate Traceable to NIST
    80 to 5,906 fpm
    0.9 to 67.2 mph
    0.8 to 58.3 kn
    0.4 to 30 m/s
    1.4 to 108 kph
    14° to 140° F
    -10° to 60° C
    Digital9,9997"2 7/8"1 5/16"4YesCarrying Case4120K1090000000
     
    Telescoping Tube
    Image of Product. Front orientation. Airflow Meters. Remote-Reading Airflow/Temperature Meters, Telescoping Tube.
    Telescoping tube meters are also known as hot wire meters. They have a probe that telescopes to reach into narrow openings.
    3.5 mm Audio Connection—Meters with a 3.5 mm audio data connection can transmit data through a USB connection using a USB adapter cord (sold separately, except for Style C).
    Overall
    Probe
    Airflow Speed
    Temperature
    Range
    Display
    Type
    Ht.
    Wd.
    Dp.
    Dia.
    Cable Lg.,
    ft.
    Max. Probe
    Extension, ft.
    Data
    Connection
    Batteries
    Included
    Each
    Measures Airflow and Temperature—With Calibration Certificate Traceable to NIST
    40 to 3,900 fpm
    0.5 to 40 mph
    1 to 30 kn
    0.2 to 20 m/s
    0.7 to 70 kph
    32° to 122° F
    0° to 50° C
    Digital7"2 15/16"1 5/16"1/2"433.5 mm AudioYes4120K1110000000
     
    USB Cords