Specifications Met Specifications Met |
|---|
|
Environment Environment |
|---|
|
Thermometer Type Thermometer Type |
|---|
| Noncontact | |
Environmental Rating Environmental Rating |
|---|
Display Type Display Type |
|---|
| Digital | |
Response Time Response Time |
|---|
|
Scale Scale |
|---|
|
Batteries Included Batteries Included |
|---|
|
Maximum Emissivity Maximum Emissivity |
|---|
|
Minimum Emissivity Minimum Emissivity |
|---|
|
NEC Hazardous Location Temperature Classification NEC Hazardous LocationTemperature Classification |
|---|
|
Protection Type Protection Type |
|---|
|
Housing Material Housing Material |
|---|
|
Emissivity Type Emissivity Type |
|---|
|
System of Measurement System of Measurement |
|---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
|---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
|---|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
|---|
|
Battery Chemistry Battery Chemistry |
|---|
|
Height Height |
|---|
|
Depth Depth |
|---|
|
About Hazardous Location Environmental Ratings
More
Hazardous Location Infrared Thermometers

These thermometers are rated for environments where hazardous material is present. They measure the temperature of surfaces without making contact and are often used to locate and diagnose problems in electrical, heating, and ventilation systems. Maximum working distance is the distance a one foot target can be reliably measured. Thermometers have adjustable emissivity, which means they can be calibrated for accurate readings of shiny surfaces.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.
Warning: These infrared thermometers are not intended for medical use. Use Non-Contact Forehead Thermometers for medical use.
Batteries | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Temp. Range | Resolution | Accuracy | Max. Working Distance, ft. | Emissivity | Response Time, sec. | Ht. | Wd. | Housing Material | Environmental Rating | Included | Size | No. Required | Each | |
For Dark, Dull, Light, Shiny Surfaces | ||||||||||||||
Adjustable Emissivity | ||||||||||||||
| -40° to 1472° F/-40° to 800° C | 0.1/0.1 | ±1% | 30 | 0.1 to 1 | 0.5 | 7" | 2" | Plastic | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Zone 1 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA | Yes | AAA | 2 | 0000000 | 000000000 |