Hazardous-Location Submersible Liquid-Level Transmitters

For Liquids
FM and C-FM approved, these transmitters safely measure liquid levels where explosive gas or dust may be present. Set them at the bottom of your tank in applications that make traditional mounting difficult. They sense liquid levels by measuring the pressure from the weight of the liquid above them. All continuously send measurements, so you can monitor status and manage components in your system. Also known as level loggers, level sensors, and pressure transducers.
For Pressure Range | Overall | Temp. Range, °F | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ft. of H2O | psi | Accuracy | Max. Pressure | Lg. | Dia. | Min. | Max. | Cable Lg., ft. | Input Voltage | For Container Type | Electrical Connection | Environmental Rating | Each | |
4-20mA Output Current | ||||||||||||||
For Liquids | ||||||||||||||
| 0-3 | 0-1 | ±0.25% | 10 psi @ 70° F | 6 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 0000000 |
| 0-5 | 0-2 | ±0.25% | 20 psi @ 70° F | 6 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
| 0-10 | 0-4 | ±0.25% | 40 psi @ 70° F | 6 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
| 0-15 | 0-6 | ±0.25% | 60 psi @ 70° F | 6 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |
| 0-30 | 0-13 | ±0.25% | 125 psi @ 70° F | 6 3/4" | 1" | -10° | 175° | 40 | 10-35V DC | Open Tank | Wire Leads | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 NEMA 6P | 0000000 | 000000 |