Airflow @ Static Pressure Airflow @ Static Pressure |
---|
Outlet Shape Outlet Shape |
---|
|
Housing Material Housing Material |
---|
|
Motor Enclosure Type Motor Enclosure Type |
---|
|
Current Current |
---|
Environmental Rating Environmental Rating |
---|
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard blowers can handle. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. Blowers with an open dripproof motor enclosure are for relatively clean, dry, indoor locations. Blowers with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
High-Output Blowers | ||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Outlet | Overall | Replacement Wheels | ||||||||||||||||||
Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Dia. | Ht. | Wd. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Wt., lbs. | Temp. Range, °F | Mount. Fasteners Included | Mount. Hole Dia. | Cannot Be Sold To | Each | Each | ||
With Round Outlet and Inlet—Totally Enclosed Motor Enclosure | ||||||||||||||||||||
230/460V AC, Three Phase—Hardwire | ||||||||||||||||||||
120 cfm @ 5 in. of H₂O 315 cfm @ 3 in. of H₂O | 65 dB @ 15 ft. | 3,450 | 1/3 | 4" | __ | __ | 5" | 9" | 17 3/4" | 15 3/8" | 17 3/4" | 52 | -10° to 150° | No | 7/16" | __ | 0000000 | 0000000 | 0000000 | 0000000 |
515 cfm @ 5 in. of H₂O 680 cfm @ 3 in. of H₂O | 65 dB @ 15 ft. | 3,450 | 1 | 6" | __ | __ | 6" | 11" | 21 1/8" | 19 1/8" | 18 1/4" | 62 | -10° to 150° | No | 7/16" | __ | 0000000 | 000000 | 0000000 | 000000 |
1,000 cfm @ 5 in. of H₂O 1,200 cfm @ 3 in. of H₂O | 70 dB @ 15 ft. | 3,450 | 3 | 6" | __ | __ | 7" | 13" | 21 1/8" | 19 1/8" | 18 7/8" | 95 | -10° to 150° | No | 7/16" | __ | 0000000 | 00000000 | 0000000 | 000000 |
1,500 cfm @ 5 in. of H₂O 1,900 cfm @ 3 in. of H₂O | 75 dB @ 15 ft. | 3,450 | 5 | 8" | __ | __ | 8" | 14" | 26 1/8" | 23 3/4" | 25 1/4" | 176 | -10° to 150° | No | 7/16" | __ | 0000000 | 00000000 | 0000000 | 000000 |
With Rectangular Outlet and Round Inlet—Totally Enclosed Motor Enclosure | ||||||||||||||||||||
120/230V AC, Single Phase—Hardwire | ||||||||||||||||||||
195 cfm @ 5 in. of H₂O 345 cfm @ 3 in. of H₂O | 70 dB @ 15 ft. | 3,450 | 3/4 | __ | 3 1/2" | 3 1/2" | 5" | 9" | 15 3/4" | 20 3/4" | 13 5/8" | 40 | -15° to 180° | No | 3/8" | __ | 0000000 | 000000 | 0000000 | 000000 |
505 cfm @ 5 in. of H₂O 635 cfm @ 3 in. of H₂O | 75 dB @ 15 ft. | 3,450 | 1 1/2 | __ | 4" | 3 1/2" | 6" | 10 5/8" | 19" | 20 3/4" | 15 5/8" | 64 | -15° to 180° | No | 3/8" | __ | 0000000 | 000000 | 0000000 | 000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||||||||
195 cfm @ 5 in. of H₂O 345 cfm @ 3 in. of H₂O | 70 dB @ 15 ft. | 3,450 | 3/4 | __ | 3 1/2" | 3 1/2" | 5" | 9" | 15 3/4" | 20 3/4" | 13 5/8" | 39 | -15° to 180° | No | 3/8" | __ | 0000000 | 000000 | 0000000 | 000000 |
505 cfm @ 5 in. of H₂O 635 cfm @ 3 in. of H₂O | 75 dB @ 15 ft. | 3,450 | 1 1/2 | __ | 4" | 3 1/2" | 6" | 10 5/8" | 19" | 20 3/4" | 15 5/8" | 64 | -15° to 180° | No | 3/8" | __ | 0000000 | 000000 | 0000000 | 000000 |
1,600 cfm @ 5 in. of H₂O 1,800 cfm @ 3 in. of H₂O | 85 dB @ 15 ft. | 3,450 | 7 1/2 | __ | 7 1/8" | 5 3/4" | 8" | 13 1/2" | 23 1/8" | 22" | 22 3/8" | 224 | -15° to 180° | No | 3/8" | CA | 0000000 | 00000000 | 0000000 | 000000 |
With Rectangular Outlet and Round Inlet—Open Dripproof Motor Enclosure | ||||||||||||||||||||
120/230V AC, Single Phase—Hardwire | ||||||||||||||||||||
195 cfm @ 5 in. of H₂O 345 cfm @ 3 in. of H₂O | 70 dB @ 15 ft. | 3,450 | 3/4 | __ | 3 1/2" | 3 1/2" | 5" | 9" | 15 3/4" | 20 3/4" | 13 5/8" | 36 | -15° to 180° | No | 3/8" | __ | 0000000 | 000000 | 0000000 | 000000 |
505 cfm @ 5 in. of H₂O 635 cfm @ 3 in. of H₂O | 75 dB @ 15 ft. | 3,450 | 1 1/2 | __ | 4" | 3 1/2" | 6" | 10 5/8" | 19" | 20 3/4" | 15 5/8" | 59 | -15° to 180° | No | 3/8" | __ | 0000000 | 000000 | 0000000 | 000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||||||||
1,600 cfm @ 5 in. of H₂O 1,800 cfm @ 3 in. of H₂O | 85 dB @ 15 ft. | 3,450 | 7 1/2 | __ | 7 1/8" | 5 3/4" | 8" | 13 1/2" | 23 1/8" | 22" | 22 3/8" | 197 | -15° to 180° | No | 3/8" | CA | 0000000 | 00000000 | 0000000 | 000000 |
Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard spark-resistant blowers can handle. They have an aluminum housing for spark resistance. They install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
Blowers | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Wheels | ||||||||||||||||
Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Outlet Dia. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Wt., lbs. | Temp. Range, °F | Mount. Fasteners Included | Mount. Hole Dia. | Each | Each | ||
With Round Outlet and Inlet—Totally Enclosed Motor Enclosure | |||||||||||||||||
120/230V AC, Single Phase—Hardwire | |||||||||||||||||
130 cfm @ 3 in. of H₂O | 75 dB @ 15 ft. | 3,450 | 1/3 | 4" | 4" | 7" | 13 5/8" | 11 3/4" | 11 1/2" | 41 | 0° to 100° | No | 7/16" | 0000000 | 0000000 | 0000000 | 0000000 |
250 cfm @ 3 in. of H₂O | 75 dB @ 15 ft. | 3,450 | 1/2 | 4" | 4" | 8 1/8" | 13 5/8" | 11 3/4" | 11 1/2" | 48 | 0° to 100° | No | 7/16" | 0000000 | 000000 | 0000000 | 000000 |
460 cfm @ 5 in. of H₂O 520 cfm @ 3 in. of H₂O | 80 dB @ 15 ft. | 3,450 | 1 | 5" | 6" | 9 3/4" | 18" | 14 1/2" | 16 1/8" | 70 | 0° to 100° | No | 7/16" | 0000000 | 000000 | 0000000 | 000000 |
530 cfm @ 5 in. of H₂O 685 cfm @ 3 in. of H₂O | 80 dB @ 15 ft. | 3,450 | 1 1/2 | 5" | 6" | 10 5/8" | 18" | 14 1/2" | 16 1/8" | 55 | 0° to 100° | No | 7/16" | 0000000 | 000000 | 0000000 | 000000 |
230/460V AC, Three Phase—Hardwire | |||||||||||||||||
250 cfm @ 3 in. of H₂O | 75 dB @ 15 ft. | 3,450 | 1/2 | 4" | 4" | 8 1/8" | 13 5/8" | 11 3/4" | 11 1/2" | 40 | 0° to 100° | No | 7/16" | 0000000 | 000000 | 0000000 | 000000 |
460 cfm @ 5 in. of H₂O 520 cfm @ 3 in. of H₂O | 80 dB @ 15 ft. | 3,450 | 1 | 5" | 6" | 9 3/4" | 18" | 14 1/2" | 16 1/8" | 65 | 0° to 100° | No | 7/16" | 0000000 | 000000 | 0000000 | 000000 |
530 cfm @ 5 in. of H₂O 685 cfm @ 3 in. of H₂O | 80 dB @ 15 ft. | 3,450 | 1 1/2 | 5" | 6" | 10 5/8" | 18" | 14 1/2" | 16 1/8" | 73 | 0° to 100° | No | 7/16" | 0000000 | 000000 | 0000000 | 000000 |
Powerful and durable, these blowers are able to blow air through larger systems that have more airflow resistance than standard hazardous location spark-resistant blowers can handle. They have an explosion-proof motor that is UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G hazardous locations. They also have an aluminum housing for spark resistance. These blowers install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
Blowers | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Wheels | |||||||||||||||
Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Outlet Dia. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Temp. Range, °F | Mount. Fasteners Included | Mount. Hole Dia. | Each | Each | ||
With Round Outlet and Inlet | ||||||||||||||||
120/230V AC, Single Phase—Hardwire | ||||||||||||||||
130 cfm @ 3 in. of H₂O | 75 dB @ 15 ft. | 3,450 | 1/3 | 4" | 4" | 7" | 13 5/8" | 11 3/4" | 11 1/2" | 0° to 100° | No | 7/16" | 0000000 | 0000000 | 0000000 | 0000000 |
250 cfm @ 3 in. of H₂O | 75 dB @ 15 ft. | 3,450 | 1/2 | 4" | 4" | 8 1/8" | 13 5/8" | 11 3/4" | 11 1/2" | 0° to 100° | No | 7/16" | 0000000 | 000000 | 0000000 | 000000 |
460 cfm @ 5 in. of H₂O 520 cfm @ 3 in. of H₂O | 80 dB @ 15 ft. | 3,450 | 1 | 5" | 6" | 9 3/4" | 18" | 14 1/2" | 16 1/8" | 0° to 100° | No | 7/16" | 0000000 | 00000000 | 0000000 | 000000 |
530 cfm @ 5 in. of H₂O 685 cfm @ 3 in. of H₂O | 80 dB @ 15 ft. | 3,450 | 1 1/2 | 5" | 6" | 10 5/8" | 18" | 14 1/2" | 16 1/8" | 0° to 100° | No | 7/16" | 0000000 | 00000000 | 0000000 | 000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||||
250 cfm @ 3 in. of H₂O | 75 dB @ 15 ft. | 3,450 | 1/2 | 4" | 4" | 8 1/8" | 13 5/8" | 11 3/4" | 11 1/2" | 0° to 100° | No | 7/16" | 0000000 | 000000 | 0000000 | 000000 |
460 cfm @ 5 in. of H₂O 520 cfm @ 3 in. of H₂O | 80 dB @ 15 ft. | 3,450 | 1 | 5" | 6" | 9 3/4" | 18" | 14 1/2" | 16 1/8" | 0° to 100° | No | 7/16" | 0000000 | 00000000 | 0000000 | 000000 |
530 cfm @ 5 in. of H₂O 685 cfm @ 3 in. of H₂O | 80 dB @ 15 ft. | 3,450 | 1 1/2 | 5" | 6" | 10 5/8" | 18" | 14 1/2" | 16 1/8" | 0° to 100° | No | 7/16" | 0000000 | 00000000 | 0000000 | 000000 |
A 304 stainless steel housing offers good corrosion resistance. These blowers install in ductwork similar to duct fans, but are for use where high static pressures are present. Use them for equipment cooling, material conveying, drying, ventilating, and exhausting. All blowers have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
Outlet | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Ht. | Wd. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Temp. Range, °F | Mount. Fasteners Included | Mount. Hole Dia. | Each | |
With Rectangular Outlet and Round Inlet—Totally Enclosed Motor Enclosure | |||||||||||||||
120/230V AC, Single Phase—Hardwire | |||||||||||||||
195 cfm @ 5 in. of H₂O 345 cfm @ 3 in. of H₂O | 70 dB @ 15 ft. | 3,450 | 3/4 | 3 1/2" | 3 1/2" | 5" | 9" | 15 3/4" | 20 3/4" | 13 5/8" | -15° to 180° | No | 3/8" | 0000000 | 0000000 |
505 cfm @ 5 in. of H₂O 635 cfm @ 3 in. of H₂O | 75 dB @ 15 ft. | 3,450 | 1 1/2 | 4" | 3 1/2" | 6" | 10 5/8" | 19" | 20 3/4" | 15 5/8" | -15° to 180° | No | 3/8" | 0000000 | 00000000 |
230/460V AC, Three Phase—Hardwire | |||||||||||||||
195 cfm @ 5 in. of H₂O 345 cfm @ 3 in. of H₂O | 70 dB @ 15 ft. | 3,450 | 3/4 | 3 1/2" | 3 1/2" | 5" | 9" | 15 3/4" | 20 3/4" | 13 5/8" | -15° to 180° | No | 3/8" | 0000000 | 00000000 |
505 cfm @ 5 in. of H₂O 635 cfm @ 3 in. of H₂O | 75 dB @ 15 ft. | 3,450 | 1 1/2 | 4" | 3 1/2" | 6" | 10 5/8" | 19" | 20 3/4" | 15 5/8" | -15° to 180° | No | 3/8" | 0000000 | 00000000 |
1,600 cfm @ 5 in. of H₂O 1,800 cfm @ 3 in. of H₂O | 85 dB @ 15 ft. | 3,450 | 7 1/2 | 7 1/8" | 5 3/4" | 8" | 13 1/2" | 23 1/8" | 22" | 22 3/8" | -15° to 180° | No | 3/8" | 0000000 | 00000000 |