Filter by
For Testing
For Use With
Meter Type
Maximum Conductivity
pH Range
Environment
Chemistry Features
Certification
Batteries Included
Housing Material
DFARS Specialty Metals
Export Control Classification Number (ECCN)
Remote-Reading Multifunction Chemistry Meters
For Testing Conductivity, Salinity, Temperature, and Total Dissolved Solids (TDS)
Conductivity | Salinity | Total Dissolved Solids (TDS) | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Range | Accuracy | Range, ppt | Accuracy | Temp. Accuracy | Range | Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Wd. | Dp. | Batteries Included | Display Type | Each | |||
For Use With Clean and Dirty Liquids | ||||||||||||||||||
| 0 to 19.99 μS 20 to 199.9 μS 200 to 1,999 μS 2 to 19.99 mS 20 to 199.9 mS | ±1% ±1% ±1% ±1% ±1% | 0 to 100 | ±1% | ±0.9° F | 0 ppm to 0.1 ppm | ±1% | 32 to 212 | IP57 | CE Marked | 7 1/2" | 3 9/16" | 1 5/16" | Yes | LCD | 1122T12 | 0000000 | ||
For Testing Oxidation Reduction Potential (ORP), pH, and Temperature
Oxidation Reduction Potential (ORP) | pH | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Range, mV | Accuracy | Range, pH | Accuracy | Temp. Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Wd. | Dp. | Batteries Included | Display Type | Each | |||
For Use With Clean and Dirty Liquids | ||||||||||||||||
| -1,000 to 1,000 | ±0.2% | 0 to 14 | ±0.01 pH | ±0.9° F | 32 to 212 | IP57 | CE Marked | 7 1/2" | 3 9/16" | 1 5/16" | Yes | LCD | 1122T14 | 0000000 | ||
Water-Resistant Multifunction Chemistry Meters
For Testing Conductivity, Salinity, and Total Dissolved Solids (TDS)
Conductivity | Salinity | Total Dissolved Solids (TDS) | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range | Accuracy | Range, ppm | Accuracy | Range | Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Wd. | Dp. | Batteries Included | Display Type | Each | |||
For Use With Clean and Dirty Liquids | ||||||||||||||||||
| Plastic | 0 to 199.9 μS 200 to 1,999 μS 2 to 19.99 mS | ±2% | 0 to 99.9 | ±2% | 0 to 99.9 ppm 100 to 999 ppm 1 to 9.99 ppt | ±2% | 32 to 149 | IP57 | CE Marked | 6 3/4" | 1 3/8" | 1 5/8" | Yes | LCD | 13945T52 | 0000000 | ||
Remote-Reading Multifunction Chemistry Meters with PC Output
For Testing Conductivity, Resistivity, Salinity, Temperature, and Total Dissolved Solids (TDS)
Conductivity | Resistivity | Salinity | Total Dissolved Solids (TDS) | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Range | Accuracy | Range, Mohm | Accuracy | Range, ppt | Accuracy | Temp. Accuracy | Range | Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Wd. | Dp. | Batteries Included | Display Type | Each | |||
For Use With Clean and Dirty Liquids | ||||||||||||||||||||
| 0 mS to 200 mS | ±1.5% | 0 to 20 | ±1.5% | 0 to 100 | ±1.5% | ±0.9° F | 0 ppt to 100 ppt | ±0.1% | 32 to 212 | IP67 | CE Marked | 6 5/16" | 3 3/16" | 1 5/8" | Yes | LCD | 14345T44 | 000000000 | ||
Bench-Top Conductivity Meters
For Testing Conductivity
Conductivity | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range | Accuracy | ATC Range, ° F | Ht. | Wd. | Dp. | Batteries Included | Each | |||
For Use With Dirty Liquids | |||||||||||
| Plastic | 0 to 0.5 μS 0 to 5 μS 0 to 50 μS 0 to 500 μS 0 to 5,000 μS | ±2% | 32 to 120 | 4" | 3 1/2" | 4 1/2" | Yes | 1128T14 | 0000000 | ||
| Plastic | 0 to 10 μS 0 to 100 μS 0 to 1,000 μS 0 to 10,000 μS | ±2% | 50 to 160 | 4" | 3 1/2" | 4 1/2" | Yes | 1128T137 | 000000 | ||
Bench-Top TDS Meters
For Testing Total Dissolved Solids (TDS)
Total Dissolved Solids (TDS) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range | Accuracy | ATC Range, ° F | Ht. | Wd. | Dp. | Batteries Included | Each | |||
For Use With Dirty Liquids | |||||||||||
| Plastic | 0 to 50 ppm 0 to 500 ppm 0 to 5,000 ppm | ±2% | 50 to 160 | 4" | 3 1/2" | 4 1/2" | Yes | 1128T16 | 0000000 | ||
ORP Meters
![]() |
For Testing Oxidation Reduction Potential (ORP)
Oxidation Reduction Potential (ORP) | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range, mV | Accuracy | Ht. | Wd. | Dp. | Batteries Included | Display Type | Each | |||
For Use With Dirty Liquids | |||||||||||
| Plastic | -999 to 999 | ±2 mV | 7" | 1 1/2" | 1 1/2" | Yes | LCD | 1196T99 | 0000000 | ||
pH Meters
For Testing pH
pH | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range, pH | Accuracy | ATC Range, ° F | Ht. | Wd. | Dp. | Batteries Included | Display Type | Each | |||
For Use With Dirty Liquids | ||||||||||||
| Glass | 0 to 14 | ±0.1 pH | 32 to 122 | 7" | 1 1/2" | 1 1/4" | Yes | LCD | 1196T35 | 0000000 | ||
Remote-Reading pH Meters
Water-Resistant ORP Meters
For Testing Oxidation Reduction Potential (ORP)
Oxidation Reduction Potential (ORP) | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range, mV | Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Wd. | Dp. | Batteries Included | Display Type | Each | |||
For Use With Dirty Liquids | ||||||||||||||
| Glass | -1,000 to 1,000 | ±2 mV | 32 to 140 | IP67 | CE Marked | 8" | 4" | 3" | Yes | LCD | 13945T18 | 0000000 | ||
Water-Resistant pH Meters
For Testing pH
pH | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor Material | Range, pH | Accuracy | ATC Range, ° F | Enclosure Rating | Certification | Ht. | Batteries Included | Display Type | Each | |||
For Use With Dirty Liquids | ||||||||||||
| Glass | -2 to 16 | ±0.01 pH | 32 to 122 | IP67 | CE Marked | 7" | Yes | LCD | 13945T19 | 0000000 | ||