Maximum Temperature Maximum Temperature |
---|
|
Minimum Temperature Minimum Temperature |
---|
|
Maximum Working Distance Maximum Working Distance |
---|
|
|
|
Connection Type Connection Type |
---|
|
Scale Scale |
---|
|
Housing Material Housing Material |
---|
|
Certification Certification |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Environmental Rating Environmental Rating |
---|
Emissivity Type Emissivity Type |
---|
|
Specifications Met Specifications Met |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
Sensor Type Sensor Type |
---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
Choosing an Electrical Switch
More
About Hazardous Location Environmental Ratings
More
About Selecting Temperature Sensors
More
Noncontact Infrared Thermocouple Probes for Surfaces


Monitor the temperature of hazardous, sensitive, and hard-to-reach surfaces without touching them. Enclosure meets NEMA 4 for use in washdown environments and IP65 for protection from dust and splashing water.
Use a power adapter (not included) to convert AC voltage to DC voltage. Use the included nuts to install these probes through a mounting bracket (not included) for continuous, hands-free temperature monitoring.
Probe | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range, ° F | Lg. | Dia. | Accuracy | Response Time, sec. | Cable Lg., ft. | Connection Type | For Panel Cutout Dia. | Cable Material | Max. Cable Temperature, ° F | Max. Working Distance, ft. | DC Voltage | Environmental Rating | Each | |
Type J | ||||||||||||||
32° to 660° | 3 1/2" | 3/4" | ±2% | 0.35 | 3.25 | Wire Leads | 3/4" | PVC Plastic | 220° | 4 | 12, 24 | IP65, NEMA 4 | 00000000 | 0000000 |
85° to 930° | 3 1/2" | 3/4" | ±2% | 0.35 | 3.25 | Wire Leads | 3/4" | PVC Plastic | 220° | 4 | 12, 24 | IP65, NEMA 4 | 00000000 | 000000 |
Infrared Thermometer Transmitters
Monitor the temperature of molten steel, furnaces, glass, and other hazardous surfaces without touching them. A built-in transmitter reads surface energy levels and converts them to analog and digital output values that can be read by a receiving device, such as a PLC. Because of this, you can use these transmitters for measuring and switching applications.
Adjust set points, emissivity range, and other settings on-site using the buttons on the transmitters. Connect transmitters to an IO-link controller (not included) to change settings remotely and alert you to errors on PLCs and human-machine interfaces.
Plug these transmitters into shielded M12 sockets since they're extremely prone to signal interference. These transmitters connect using two wires to send a 4-20mA current output and four wires to use the switching output and IO-link. Connect to pin 5 to utilize the test function to verify that the transmitter's signal processing is working correctly. To view transmitter wiring diagrams, select a part number and click Product Detail.
Their lenses resist scratches, which could cause transmitters to lose focus. All are IP-rated for protection against dust and low-pressure jets of water. Made of 303 stainless steel, these transmitters resist corrosion.
Transmitters can be used on all surfaces. For best results when measuring at an angle or working on round or uneven surfaces, use transmitters with laser sight.
Transmitters with a wavelength range of 0.78–1.06 microns are best for use with glass. Use transmitters with a wavelength range of 1–1.7 microns on metal, ceramics, and graphite. Transmitters with a wavelength range of 8–14 microns are useful for plastic, fabrics, food products, and other metal-free surfaces.
Add accessories to protect your infrared thermometer transmitter in hot or dirty environments. Air purges flush out dust, moisture, and other contaminants on transmitter lenses that can interfere with infrared radiation focus and cause inaccurate readings. Cooling jackets connect to a compressed air or water line to keep temperature transmitters from overheating. Protective covers prevent dirt buildup and excessive exposure to light, which can cause transmitters to lose focus. Insulating tubes prevent overheating by protecting thermometers against heat from mounting brackets or other surfaces.
For technical drawings and 3-D models, click on a part number.



Transmitters | Mounting Brackets | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wavelength Range, microns | Temperature Range | Resolution | Accuracy | Digital Display Type | Emissivity | Response Time, sec. | Length | Diameter | Housing Material | Output Type | Each | Each | ||
Bracket Mount with Scratch-Resistant Lens | ||||||||||||||
0.78 - 1.06 | 932° to 4532° F/500° to 2500° C | 1° F/1° C | ±0.3% | LED | 0.1 to 1.1 | 0.002 | 8 7/16" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 00000000 | 000000000 | 00000000 | 000000 |
1 - 1.7 | 482° to 2912° F/250° to 1600° C | 1° F/1° C | ±0.5% | LED | 0.1 to 1.1 | 0.002 | 8 7/16" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 00000000 | 00000000 | 00000000 | 00000 |
8 - 14 | 32° to 1831° F/0° to 1000° C | 1° F/0.5° C | ±1% | LED | 0.1 to 1.1 | 0.1 | 7 1/2" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 00000000 | 00000000 | 00000000 | 00000 |
Bracket Mount with Scratch-Resistant Lens and Laser Sight | ||||||||||||||
1 - 1.7 | 482° to 2912° F/250° to 1600° C | 1° F/1° C | ±0.5% | LED | 0.1 to 1.1 | 0.002 | 9 7/16" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 00000000 | 00000000 | 00000000 | 00000 |
8 - 14 | 32° to 1831° F/0° to 1000° C | 1° F/0.5° C | ±1% | LED | 0.1 to 1.1 | 0.1 | 8 1/8" | 1 3/16" | 303 Stainless Steel | Digital/Analog | 00000000 | 00000000 | 00000000 | 00000 |
Infrared Thermometers with Calibration Certificate








Ensure the accuracy of noncontact temperature readings of dangerous and inaccessible surfaces with these thermometers that come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy. Maximum working distance is the distance a one foot target can be reliably measured.
Thermometers with adjustable emissivity can be calibrated for more accurate readings of shiny surfaces than thermometers with fixed emissivity.
Warning: These infrared thermometers are not intended for medical use.
Temperature Range | Resolution | Accuracy | Max. Working Distance, ft. | Emissivity | Response Time, sec. | Ht. | Wd. | Housing Material | Specifications Met | Batteries Included | Each | ||
For Dark Surfaces | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Fixed Emissivity | |||||||||||||
A | -76° to 932° F/-60° to 500° C | 0.1/0.1 | ±2% | 2 | 0.95 | 1 | 7" | 1 1/2" | Plastic | CE Marked | Yes | 0000000 | 0000000 |
B | -58° to 1832° F/-50° to 1000° C | 0.1/0.1 | ±1.5% | 50 | 0.95 | 1 | 9" | 2 1/4" | Plastic | CE Marked | Yes | 00000000 | 000000 |
For Dark, Light, Shiny Surfaces | |||||||||||||
Adjustable Emissivity | |||||||||||||
C | -58° to 1200° F/-50° to 650° C | 0.1/0.1 | ±1% | 12 | 0.1 to 1 | 1 | 6 3/8" | 1 5/8" | Plastic | CE Marked | Yes | 0000000 | 000000 |
D | -40° to 1202° F/-40° to 650° C | 0.1/0.1 | ±1% | 30 | 0.1 to 1 | 1 | 7" | 2" | Plastic | CE Marked | Yes | 00000000 | 000000 |
D | -40° to 1472° F/-40° to 800° C | 0.1/0.1 | ±1% | 50 | 0.1 to 1 | 1 | 7" | 2" | Plastic | CE Marked | Yes | 00000000 | 000000 |
E | -40° to 1022° F/-40° to 550° C | 0.1/0.1 | ±1% | 12 | 0.3 to 0.95 | 1 | 7" | 2" | Plastic | CE Marked | Yes | 00000000 | 000000 |
F | -4° to 1202° F/-20° to 650° C | 0.1/0.1 | ±1% | Not Rated | 0.1 to 1 | 0.5 | 7 3/8" | 2 3/16" | Plastic | CE Marked | Yes | 00000000 | 000000 |
G | -58° to 1832° F/-50° to 1000° C | 0.1/0.1 | ±1% | Not Rated | 0.1 to 1 | 0.5 | 5 11/16" | 1 11/16" | Plastic | CE Marked | Yes | 00000000 | 000000 |
H | -58° to 3992° F/-50° to 2200° C | 0.1/0.1 | ±1% | Not Rated | 0.1 to 1 | 0.1 | 8" | 2" | Plastic | CE Marked | Yes | 00000000 | 000000 |
Fixed Emissivity | |||||||||||||
B | -4° to 630° F/-20° to 330° C | 0.1/0.1 | ±2% | Not Rated | 0.95 | 0.5 | 6 1/4" | 1 9/16" | Plastic | CE Marked | Yes | 00000000 | 000000 |
Pocket Infrared Thermometers






Keep these small thermometers in your pocket or toolkit to spot check the temperature of dangerous, hard-to-reach, and moving surfaces without touching them. Maximum working distance is the distance a one foot target can be reliably measured.
Thermometers with adjustable emissivity can be calibrated for more accurate readings of shiny surfaces than thermometers with fixed emissivity.
Thermometers with laser sight have a red beam of light to indicate the precise area being measured.
Thermometers with Bluetooth wirelessly send temperature results to an app downloaded to your smartphone. Use the app to adjust the emissivity.
Warning: These infrared thermometers are not intended for medical use.
Temperature Range | Resolution | Accuracy | Max. Working Distance | Emissivity | Response Time, sec. | Ht. | Wd. | Features | Housing Material | Environmental Rating | Batteries Included | Each | ||
For Dark Surfaces | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Fixed Emissivity | ||||||||||||||
A | -27° to 482° F/-33° to 250° C | 0.1/0.1 | ±2% | Not Rated | 0.95 | 1 | 6" | 1/2" | Automatic Shutoff | Brass | __ | Yes | 0000000 | 000000 |
B | -27° to 932° F/-33° to 500° C | 0.1/0.1 | ±2% | 6" | 0.95 | 1 | 6" | 1" | Automatic Shutoff, Backlit Display, Laser Sight | Plastic | __ | Yes | 0000000 | 00000 |
C | -25° to 999° F/-32° to 535° C | 0.1/0.1 | ±5° F/±3° C | 2ft. | 0.95 | 1 | 8 1/16" | 2 7/16" | Automatic Shutoff, Laser Sight | Plastic | __ | Yes | 0000000 | 000000 |
C | -13° to 482° F/-25° to 250° C | 0.1/0.1 | ±2% | Not Rated | 95 | 1 | 3 1/8" | 1 1/4" | Min./Max. Memory | Plastic | IP65 | Yes | 0000000 | 00000 |
For Dark, Dull, Light, Shiny Surfaces | ||||||||||||||
Adjustable Emissivity | ||||||||||||||
F | -22° to 480° F/-30° to 250° C | 0.1/0.1 | ±2.7% | __ | 0.1 to 1 | 1 | 5 1/2" | 1 3/8" | Data Logging Capabilities, Laser Sight, Bluetooth, Min./Max. Memory | Plastic | __ | Yes | 0000000 | 000000 |
For Dark, Light, Shiny Surfaces | ||||||||||||||
Adjustable Emissivity | ||||||||||||||
D | -22° to 572° F/-30° to 300° C | 0.1/0.1 | ±2% | 6" | 0.2 to 0.99 | 0.5 | 4 1/2" | 1.7" | Automatic Shutoff, Laser Sight | Plastic | IP40 | Yes | 0000000 | 000000 |
E | 32° to 932° F/0° to 500° C | 1/1 | ±3.6° F/±2° C | 15ft. | 0.7 to 0.95 | 1 | 6 5/16" | 1 11/16" | Automatic Shutoff, Laser Sight | Plastic | IP67 | Yes | 0000000 | 000000 |
Accessories for Infrared Thermometer Transmitters




Use these accessories to protect your infrared thermometer transmitter and keep it working properly in hot or dirty environments.
Air purges flush out dust, moisture, and other contaminants on transmitter lenses that can interfere with infrared radiation focus and cause inaccurate readings. Connect them to a compressed air line to use.
Cooling jackets connect to a compressed air or water line to keep temperature transmitters from overheating. They’re recommended for use if operating in environments over 149° F.
Protective covers prevent dirt buildup and excessive exposure to light, which can cause transmitters to lose focus.
Insulating tubes prevent overheating by protecting thermometers against heat from mounting brackets or other surfaces.
For technical drawings and 3-D models, click on a part number.
Thermal Imaging Cameras


Detect hot spots, leaks, moisture problems, and construction defects invisible to the eye. These imaging guns translate thermal energy into a color image that indicates hotter areas as brighter and cooler areas as darker, so it’s easy to identify and diagnose problems on instrument panels, HVAC systems, and other equipment. To review footage at a later date, use them to take photos and videos. The lower a camera’s thermal sensitivity, the more precise heat differences it will detect for more detailed images. All are CE marked as meeting European standards for health, safety, and environmental protection. Some include a calibration certificate traceable to NIST stating they’ve passed a test for accuracy.


FDA compliant cameras are approved for use alongside other screening devices to detect differences in skin surface temperature. Use screening mode to scan large crowds of people, and these cameras will notify you when someone’s temperature is above your specified range. Draw a square around a specific area to get its average temperature with the area box function, or target a specific object with the spot meter feature. A laser sight tells you how far you are from your target, so you know you’re standing at a safe distance. Record verbal notes for documentation with the built-in microphone. These cameras connect to computers via Bluetooth, Wi-Fi, or a USB cable for quick data transfers.
Use cameras with a 2732° F maximum temperature in facilities with extremely hot equipment such as boilers and steam systems. A one-touch level/span function lets you focus on a single area by tapping the touch screen, giving you a temperature span and contrast level specific to that area. These cameras have a 180° rotating lens, so you can get a clear view of your target from any angle.
Cameras that cannot be sold to California do not meet local efficiency standards.
Temperature Range | Thermal Sensitivity (NETD) | Resolution | Accuracy | Emissivity | Ht. | Wd. | Screen Size | Housing Material | Specifications Met | Certification | Batteries Included | Cannot Be Sold To | Each | ||
A | -4° to 1200° F/-20° to 650° C | <40 mK | 320 x 240 | ±2% | 0.01 to 1 | 11" | 4 5/8" | 4" | Plastic | CE Marked | __ | Yes | CA | 0000000 | 000000000 |
A | -4° to 1200° F/-20° to 650° C | <40 mK | 320 x 240 | ±2% | 0.01 to 1 | 11" | 4 5/8" | 4" | Plastic | CE Marked | Calibration Certificate Traceable to NIST | Yes | CA | 00000000 | 00000000 |
B | -4° to 2732° F/-20° to 1500° C | <40 mK | 464×348 | ±2% | 0.01 to 1 | 6 5/8" | 5 1/2" | 4" | Plastic | CE Marked; FDA Compliant 21 CFR 884.2980 | __ | Yes | __ | 0000000 | 000000000 |
B | -4° to 2732° F/-20° to 1500° C | <40 mK | 464×348 | ±2% | 0.01 to 1 | 6 5/8" | 5 1/2" | 4" | Plastic | CE Marked; FDA Compliant 21 CFR 884.2980 | Calibration Certificate Traceable to NIST | Yes | __ | 0000000 | 000000000 |
1596469021@halfx_637320478563464625.png?ver=imagenotfound)
Style C cameras plug into your smart phone, displaying the thermal imaging on your phone’s screen.
Emissivity | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Thermal Sensitivity (NETD) | Accuracy | For Dark Surfaces | For Dull Surfaces | For Light Surfaces | For Shiny Surfaces | Ht. | Wd. | Housing Material | Specifications Met | Batteries Included | Each | ||
4-pin USB Type A (Male) C Connection | ||||||||||||||
C | -4° to 752° F/-20° to 400° C | 70 mK | ±5% | 0.95 | 0.8 | 0.6 | 0.3 | 1 5/16" | 2 11/16" | Plastic | CE Marked | Yes | 0000000 | 0000000 |
8 Pin Apple Compatible Connection | ||||||||||||||
C | -4° to 752° F/-20° to 400° C | 70 mK | ±5% | 0.95 | 0.8 | 0.6 | 0.3 | 1 5/16" | 2 11/16" | Plastic | CE Marked; MFi Certified | Yes | 0000000 | 000000 |
Infrared Thermometers







Measure the temperature of dangerous, hard-to-reach, and moving surfaces without risking electrical shock or contamination. These thermometers are often used to locate and diagnose problems in electrical, heating, and ventilation systems. Maximum working distance is the distance a one foot target can be reliably measured.
Thermometers with adjustable emissivity can be calibrated for more accurate readings of shiny surfaces than thermometers with fixed emissivity.
Warning: These infrared thermometers are not intended for medical use. Use Non-Contact Forehead Thermometers for medical use.
Temperature Range | Resolution | Accuracy | Max. Working Distance, ft. | Emissivity | Response Time, sec. | Ht. | Wd. | Housing Material | Features | Specifications Met | Batteries Included | Each | ||
For Dark, Light, Shiny Surfaces | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Adjustable Emissivity | ||||||||||||||
A | -58° to 1200° F/-50° to 650° C | 0.1/0.1 | ±1% | 12 | 0.1 to 1 | 1 | 6 3/8" | 1 5/8" | Plastic | Automatic Shutoff, Laser Sight | CE Marked | Yes | 0000000 | 0000000 |
B | -58° to 1832° F/-50° to 1000° C | 0.1/0.1 | ±1% | 30 | 0.1 to 1 | 1 | 5 3/4" | 1 5/8" | Plastic | Automatic Shutoff, Laser Sight | CE Marked | Yes | 00000000 | 000000 |
C | -40° to 1022° F/-40° to 550° C | 0.1/0.1 | ±1% | 12 | 0.3 to 0.95 | 1 | 7" | 2" | Plastic | Automatic Shutoff, Laser Sight | CE Marked | Yes | 00000000 | 000000 |
D | -40° to 1202° F/-40° to 650° C | 0.1/0.1 | ±1% | 30 | 0.1 to 1 | 1 | 7" | 2" | Plastic | Automatic Shutoff, Laser Sight | CE Marked | Yes | 00000000 | 000000 |
D | -40° to 1472° F/-40° to 800° C | 0.1/0.1 | ±1% | 50 | 0.1 to 1 | 1 | 7" | 2" | Plastic | Automatic Shutoff, Laser Sight | CE Marked | Yes | 00000000 | 000000 |
E | -22° to 932° F/-30° to 500° C | 0.1/0.1 | ±1.5% | 10 | 0.1 to 1 | 1 | 6 7/8" | 3" | Plastic | Automatic Shutoff, Laser Sight | CE Marked | Yes | 0000000 | 000000 |
F | -4° to 1202° F/-20° to 650° C | 0.1/0.1 | ±1% | 12 | 0.1 to 1 | 1 | 7 7/16" | 2 3/16" | Plastic | Automatic Shutoff, Laser Sight, Waterproof | CE Marked | Yes | 00000000 | 000000 |
For Dark Surfaces | ||||||||||||||
Fixed Emissivity | ||||||||||||||
G | 0° to 750° F/-18° to 400° C | 0.1/0.1 | ±2% | 8 | 0.95 | 1 | 6" | 1 1/2" | Plastic | Automatic Shutoff, Laser Sight | CE Marked | Yes | 0000000 | 000000 |
Pocket Infrared Thermometers with Calibration Certificate



To confirm the accuracy of noncontact temperature readings of dangerous and inaccessible surfaces, these thermometers come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy. Maximum working distance is the distance a one foot target can be reliably measured.
Thermometers with adjustable emissivity can be calibrated for more accurate readings of shiny surfaces than thermometers with fixed emissivity.
Warning: These infrared thermometers are not intended for medical use. Use Non-Contact Forehead Thermometers for medical use.
Temperature Range | Resolution | Accuracy | Max. Working Distance | Emissivity | Response Time, sec. | Ht. | Wd. | Housing Material | Specifications Met | Batteries Included | Each | ||
For Dark, Light, Shiny Surfaces | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Adjustable Emissivity | |||||||||||||
A | -67° to 482° F/-55° to 250° C | 0.1/0.1 | ±2° F/±1° C | 16" | 0.05 to 1 | 1 | 4" | 2" | Plastic | CE Marked | Yes | 0000000 | 000000 |
A | -30° to 430° F/-33° to 220° C | 0.5/0.2 | ±4° F/±2° C | 10" | 0.05 to 1 | 1 | 1 1/2" | 2 1/2" | Plastic | CE Marked | Yes | 0000000 | 00000 |
Fixed Emissivity | |||||||||||||
B | -27° to 428° F/-33° to 220° C | 0.1/0.1 | ±1.8° F/±1.0° C | 10" | 0.95 | 1 | 3 1/4" | 2 1/2" | Plastic | CE Marked | Yes | 0000000 | 00000 |
For Dark Surfaces | |||||||||||||
Fixed Emissivity | |||||||||||||
C | -7° to 230° F/-22° to 110° C | 0.1/0.1 | ±2.7° F/±1.5° C | 10" | 0.95 | 1 | 2 1/2" | 1 1/2" | Plastic | CE Marked | Yes | 0000000 | 00000 |
Non-Contact Temperature Screeners
Quickly take people’s temperatures as they enter your facility to screen out anyone with a high reading. These screeners have a thermal camera that uses infrared light to measure forehead temperature in two seconds at a distance of one to two feet. They’re accurate within 0.9° F and 0.5° C, and work even if people are wearing masks, hats, and glasses. If their temperature is normal, there’s an audible notification. Connect them to your network using Wi-Fi or their Ethernet port in order to create a library of photos, retain data for reporting, and customize the screeners to display directions and your company name and logo. For basic temperature scanning only, there’s no need to connect them to your network—simply plug their power cord into a wall outlet. If you want to keep people from entering until they pass the temperature check, wire these screeners to doors and gates. CE marked, they meet European safety, health, and environmental protection requirements.
Mount these screeners to a wall, or add a floor stand.
Warning: These screeners are not intended for medical use.
For technical drawings and 3-D models, click on a part number.


Temperature Range; Temperature Range - 2 | Resolution ; Resolution - 2 | Accuracy; Accuracy - 2 | Max. Working Distance, ft. | Response Time, sec. | Ht. | Wd. | Dp. | Housing Material | Specifications Met | Cord Lg., ft. | Mounting Fasteners Included | Each | |
89° to 106° F/31° to 41° C | 0.1° F/0.1° C | ±0.9° F/±0.5° C | 2 | 2 | 10 1/8" | 5 7/16" | 1 13/16" | 6061 Aluminum | CE Marked | 5 | Yes | 0000000 | 000000000 |

Component | Ht. | Lg. | Wd. | Each | |
Floor Stand | 45" | 11 5/8" | 14" | 0000000 | 0000000 |
Hazardous Location Infrared Thermometers

These thermometers are rated for environments where hazardous material is present. They measure the temperature of surfaces without making contact and are often used to locate and diagnose problems in electrical, heating, and ventilation systems. Maximum working distance is the distance a one foot target can be reliably measured. Thermometers have adjustable emissivity, which means they can be calibrated for accurate readings of shiny surfaces.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.
Warning: These infrared thermometers are not intended for medical use. Use Non-Contact Forehead Thermometers for medical use.
Batteries | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range | Resolution | Accuracy | Max. Working Distance, ft. | Emissivity | Response Time, sec. | Ht. | Wd. | Housing Material | Environmental Rating | Included | Size | No. Required | Each | |
For Dark, Dull, Light, Shiny Surfaces | ||||||||||||||
Adjustable Emissivity | ||||||||||||||
-40° to 1472° F/-40° to 800° C | 0.1/0.1 | ±1% | 30 | 0.1 to 1 | 0.5 | 7" | 2" | Plastic | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Zone 1 Groups IIC, IIB, IIA IEC Zone 1 Groups IIC, IIB, IIA | Yes | AAA | 2 | 0000000 | 000000000 |
Fixture-Mount Motion-Sensing Light Controls

Mount these controls directly to a light fixture. Also known as occupancy sensors, they turn lights on when movement is detected and off when an area is unoccupied. The infrared sensors detect changes in heat sources and require a direct view of the occupants. All have a time delay to turn lights off after a set time.
Mounting extensions (sold separately) improve the position of light controls.
For technical drawings and 3-D models, click on a part number.
Conduit | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Coverage, sq. ft. | No. of Circuits Controlled | Input Voltage | Wattage | Max. Mounting Ht., ft. | Color | Housing Material | Connection Gender | Trade Size | Thread Type | Ht. | Wd. | Dp. | Wire Connection Type | Specifications Met | Each | |
155 | 1 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 45 | White | Plastic | Male | 1/2 | NPT | 2 3/16" | 4 3/32" | 4 5/8" | Wire Leads | UL Listed, C-UL Listed | 0000000 | 0000000 |
155 | 2 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 45 | White | Plastic | Male | 1/2 | NPT | 2 3/16" | 4 3/32" | 4 5/8" | Wire Leads | UL Listed, C-UL Listed | 0000000 | 000000 |
Mounting Extension | 0000000 | Each | 000000 |
Fixture-Mount Motion-Sensing Light Controls for Wet Locations

Rated IP65, these controls are protected from washdowns. Also known as occupancy sensors, they turn lights on when movement is detected and off when an area is unoccupied. The infrared sensors detect changes in heat sources and require a direct view of the occupants. All have a time delay to turn lights off after a set time.
For technical drawings and 3-D models, click on a part number.
Conduit | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Coverage, sq. ft. | No. of Circuits Controlled | Input Voltage | Wattage | Max. Mounting Ht., ft. | Color | Housing Material | Connection Gender | Trade Size | Thread Type | Ht. | Dia. | Wire Connection Type | Specifications Met | Each | |
1,000 | 1 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 40 | White | Plastic | Male | 1/2 | NPT | 1 15/16" | 4 1/16" | Wire Leads | UL Listed, C-UL Listed | 0000000 | 0000000 |
1,200 | 1 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 20 | White | Plastic | Male | 1/2 | NPT | 1 15/16" | 4 1/16" | Wire Leads | UL Listed, C-UL Listed | 0000000 | 000000 |
Ceiling-Mount Motion-Sensing Light Controls

Also known as occupancy sensors, these controls turn lights on when movement is detected and off when an area is unoccupied. All have a time delay to turn lights off after a set time.
Infrared sensors detect moving heat sources and require a direct view of the occupants.
Infrared/ultrasonic sensors minimize false activation by detecting changes in heat sources and motion. They can be set so that only one or both detection methods are required to activate and hold lights on.
For technical drawings and 3-D models, click on a part number.
Motion Sensor Type | Coverage, sq. ft. | No. of Circuits Controlled | Input Voltage | Wattage | For Outlet Box Type | Color | Ht. | Dia. | Wire Connection Type | Specifications Met | Each | |
Infrared | 1,500 | 1 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 2 Device (2 Gang) | White | 2 1/8" | 4" | Wire Leads | UL Listed, C-UL Listed | 0000000 | 0000000 |
Infrared/Ultrasonic | 1,000 | 1 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 2 Device (2 Gang) | White | 2 1/16" | 4 1/2" | Screw Terminals | UL Listed, C-UL Listed | 0000000 | 000000 |
Guard | 0000000 | Each | 000000 |
Multi-Way Wall-Mount Motion-Sensing Light Controls

Control lights on a single circuit from more than one motion-sensing switch. Also known as occupancy sensors, these controls turn lights on when movement is detected and off when an area is unoccupied. The infrared sensors detect changes in heat sources and require a direct view of the occupants. Use up to four controls on the same circuit to detect motion in large rooms. All have a time delay to turn lights off after a set time.
Coverage, sq. ft. | No. of Circuits Controlled | Max. No. per Circuit | Input Voltage | Wattage | For Outlet Box Type | Max. Mounting Ht., ft. | Color | Housing Material | Wire Connection Type | Specifications Met | Each | |
1,050 | 1 | 4 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 1 Device (1 Gang) | 4 | White | Plastic | Wire Leads | UL Listed, C-UL Listed | 0000000 | 0000000 |
Wall/Ceiling-Mount Motion-Sensing Light Controls

Also known as occupancy sensors, these controls turn lights on when movement is detected and off when an area is unoccupied. The infrared/ultrasonic sensors minimize false activation by detecting heat and motion. They can be set so that only one or both detection methods are required to activate and hold lights on. All have a time delay to turn lights off after a set time. The mounting bracket swivels 90° so that the control can be mounted on a wall or ceiling.
Power controllers (sold separately) are required to switch a 120- or 277-volt AC lighting circuit. They have a relay that switches a maximum 20 amp load.
For technical drawings and 3-D models, click on a part number.
Coverage, sq. ft. | No. of Circuits Controlled | Input Voltage | Max. Mounting Ht., ft. | Mounting Hardware Included | Swivel Angle | Color | Housing Material | Ht. | Wd. | Dp. | Wire Connection Type | Specifications Met | Each | |
2,000 | 1 | 24V DC | 10 | Yes | 90° | White | Plastic | 4 3/8" | 3 3/8" | 2" | Wire Leads | UL Listed, C-UL Listed | 0000000 | 0000000 |
Power Controller | 0000000 | Each | 000000 |
Wall-Mount Motion-Sensing Light Controls


Light controls fit standard wall plates. Also known as occupancy sensors, they turn lights on when movement is detected and off when an area is unoccupied. The infrared sensors detect changes in heat sources and require a direct view of the occupants. All have a time delay to turn lights off after a set time.
Ivory | White | |||||||
---|---|---|---|---|---|---|---|---|
Coverage, sq. ft. | No. of Circuits Controlled | Input Voltage | Wattage | Wire Connection Type | Each | Each | ||
180 | 2 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | Wire Leads | 0000000 | 0000000 | 0000000 | 0000000 |
300 | 1 | 120V AC 240V AC 277V AC | 1,200 W @ 277 V AC 1,200 W @ 240 V AC 1,000 W @ 120 V AC | Wire Leads | 0000000 | 00000 | 0000000 | 00000 |
Motion-Sensing Door Chimes


A chime announces when someone passes through the infrared light beam and a counter keeps track of each entrance and exit. Mount the transmitter and beam reflector between 2 and 20 feet apart. The chime's volume is adjustable up to 85 dB. It cannot be sold to California due to local energy efficiency regulations.
Additional chimes (sold separately) can be added to the transmitter.
Chime | Transmitter | Beam Reflector | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Wd. | Ht. | Dp. | Wd. | Ht. | Material | Color | Volume | For Use Outdoors | Electrical Connection | Includes | Mount Type | Mount. Fasteners Included | Cannot Be Sold To | Each | |
3 3/4" | 5" | 1 1/2" | 5" | 2 3/4" | 2 1/2" | 4" | 2" | Plastic | White | 85 dB @ 10 ft. | No | Two-Prong Plug | 26-ft. of 24 Gauge Wire, Beam Reflector, Chime, Plug-In Transformer, Transmitter | Surface | Yes | CA | 00000000 | 0000000 |
Additional Chime | 00000000 | Each | 0000000 |
Non-Contact Forehead Thermometers

These thermometers take touch-free readings in a single second with an infrared sensor. Unlike traditional thermometers, they don’t need to be disinfected between uses, so you can quickly take temperatures from multiple people without the risk of spreading illness. The digital LCD display is easy to read even in dim lighting. These thermometers glow green, orange, or red to indicate normal, elevated, or high body temperatures.
All are registered with the FDA for use as a medical device. They also meet ISO 13485 standards for medical device design and manufacturing.
These thermometers cannot be sold to Canada due to import regulations.
Temperature Range | Resolution | Accuracy | Max. Distance | Response Time, sec. | Ht. | Dp. | Housing Material | Specifications Met | Batteries Included | Cannot Be Sold To | Each | |
95° to 107° F/35° to 42° C | 0.1° F/0.1° C | ±0.4° F/±0.2° C | 1" | 1 | 5" | 1 1/2" | Plastic | FDA Registered, Class II Medical Device; ISO 13485 | Yes | Canada | 000000 | 0000000 |