Electrical Properties Electrical Properties |
---|
|
Width Width |
---|
Airflow Airflow |
---|
|
Air Consumption Air Consumption |
---|
Specifications Met Specifications Met |
---|
|
Airflow Rate Airflow Rate |
---|
|
Also known as ionizing bars, these bars remove static from moving materials on conveyors and assembly lines where there is little or no air movement. Mount bars 1" to 7" from the material. Do not mount directly over metal parts or rollers; the metal will absorb the ion charge and reduce the effectiveness of the bar.
Power supplies are required and can operate up to two static-eliminating bars.
Optional bar tester indicates whether your static eliminator is operating.
Static Control | |||||||||
---|---|---|---|---|---|---|---|---|---|
Wd. | Dp. | Ht. | Wd. | Dp. | Voltage | Power Cord Lg., ft. | Features | Each | |
6" | 7" | 1 3/8" | 6" | 3/4" | 120V AC/240V AC | 6 1/2 | Grounding Cord with Ring Terminal | 0000000 | 0000000 |
9" | 7" | 1 3/8" | 9" | 3/4" | 120V AC/240V AC | 6 1/2 | Grounding Cord with Ring Terminal | 0000000 | 000000 |
12" | 7" | 1 3/8" | 12" | 3/4" | 120V AC/240V AC | 6 1/2 | Grounding Cord with Ring Terminal | 0000000 | 000000 |
15" | 7" | 1 3/8" | 15" | 3/4" | 120V AC/240V AC | 6 1/2 | Grounding Cord with Ring Terminal | 0000000 | 000000 |
18" | 7" | 1 3/8" | 18" | 3/4" | 120V AC/240V AC | 6 1/2 | Grounding Cord with Ring Terminal | 0000000 | 000000 |
20" | 7" | 1 3/8" | 20" | 3/4" | 120V AC/240V AC | 6 1/2 | Grounding Cord with Ring Terminal | 0000000 | 000000 |
24" | 7" | 1 3/8" | 24" | 3/4" | 120V AC/240V AC | 6 1/2 | Grounding Cord with Ring Terminal | 0000000 | 000000 |
30" | 7" | 1 3/8" | 30" | 3/4" | 120V AC/240V AC | 6 1/2 | Grounding Cord with Ring Terminal | 0000000 | 000000 |
33" | 7" | 1 3/8" | 33" | 3/4" | 120V AC/240V AC | 6 1/2 | Grounding Cord with Ring Terminal | 0000000 | 000000 |
36" | 7" | 1 3/8" | 36" | 3/4" | 120V AC/240V AC | 6 1/2 | Grounding Cord with Ring Terminal | 0000000 | 000000 |
42" | 7" | 1 3/8" | 42" | 3/4" | 120V AC/240V AC | 6 1/2 | Grounding Cord with Ring Terminal | 0000000 | 000000 |
48" | 7" | 1 3/8" | 48" | 3/4" | 120V AC/240V AC | 6 1/2 | Grounding Cord with Ring Terminal | 0000000 | 000000 |
60" | 7" | 1 3/8" | 60" | 3/4" | 120V AC/240V AC | 6 1/2 | Grounding Cord with Ring Terminal | 0000000 | 000000 |
66" | 7" | 1 3/8" | 66" | 3/4" | 120V AC/240V AC | 6 1/2 | Grounding Cord with Ring Terminal | 0000000 | 000000 |
72" | 7" | 1 3/8" | 72" | 3/4" | 120V AC/240V AC | 6 1/2 | Grounding Cord with Ring Terminal | 0000000 | 000000 |
96" | 7" | 1 3/8" | 96" | 3/4" | 120V AC/240V AC | 6 1/2 | Grounding Cord with Ring Terminal | 0000000 | 000000 |
Project a curtain-like stream of static-eliminating ionized air to protect against electrostatic discharge.
Blowers with filters keep dust and dirt particles out of the airstream.
Blowers with heaters reduce wind chill to moderate temperature.
Static Control | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | No. of Speeds | Wd. | Dp., ft. | Ht. | Wd. | Dp. | Voltage | Plug Type | Cord Lg., ft. | Each | |
Blowers with Filter | |||||||||||
148 | Variable | 18" | 3 | 7 3/4" | 10 3/16" | 9 3/8" | 120V AC | Three Prong | 6 | 0000000 | 000000000 |
255 | Variable | 24" | 8 | 8 3/4" | 14 1/8" | 10" | 120V AC | Three Prong | 6 | 0000000 | 00000000 |
300 | Variable | 24" | 10 | 9 3/4" | 16 3/8" | 13 1/2" | 120V AC | Three Prong | 6 | 0000000 | 00000000 |
Blowers with Heater | |||||||||||
120 | 3 | 36" | 6 | 7 7/16" | 17 1/2" | 8 11/16" | 120V AC | Three Prong | 6 | 0000000 | 000000 |
150 | 3 | 36" | 6 | 7 1/4" | 14 1/8" | 6 1/2" | 120V AC | Three Prong | 6 | 0000000 | 000000 |
Floor Stand for 300 cfm Blower (50"-74" Ht.) | 0000000 | Each | 0000000 |
These blowers create an extra-wide field of ionized air to protect against electrostatic discharge in large areas. They can be suspended from a ceiling or mounted to a wall, floor, or machine frame.
Optional filters keep dust and dirt particles out of the airstream.
Static Control | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | No. of Speeds | No. of Fans | Wd. | Dp., ft. | Ht. | Wd. | Dp. | Voltage | Plug Type | Cord Lg., ft. | Each | |
105 | Variable | 1 | 14" | 8 | 3 9/16" | 20" | 5 3/8" | 120V AC | Three Prong | 6 1/2 | 0000000 | 000000000 |
210 | Variable | 2 | 24" | 8 | 3 9/16" | 30" | 5 3/8" | 120V AC | Three Prong | 6 1/2 | 0000000 | 00000000 |
315 | Variable | 3 | 34" | 8 | 3 9/16" | 40" | 5 3/8" | 120V AC | Three Prong | 6 1/2 | 0000000 | 00000000 |
524 | Variable | 5 | 54" | 8 | 3 9/16" | 60" | 5 3/8" | 120V AC | Three Prong | 6 1/2 | 0000000 | 00000000 |
Optional Air Filters (Pkg. of 10) | 0000000 | Pkg. | 000000 |
Spread the range of static control further than static eliminators without a fan. Small enough to fit on your desktop, these create an ionized field across your immediate workspace to protect against electrostatic discharge.
Static eliminators with a heater offer an optional warm airflow for comfort in cool areas.
Static eliminators with a quiet mode have a slower fan speed than other static eliminators and are often used in small-parts and soldering applications. They’re also suitable for use in clean rooms rated to both Federal Standard and ISO classes.
Use the optional articulating arms for positioning the static eliminators.
The replacement filter kits contain one filter retainer, which holds a filter in place, and one filter.
Static Control | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | No. of Speeds | Wd. | Dp. | Ht. | Wd. | Dp. | Voltage | Plug Type | Environmental Rating | Cord Lg., ft. | Each | |
With Swivels | ||||||||||||
42 | 2 | 12" | 36" | 5 3/8" | 3 7/8" | 2 3/8" | 120V AC | Three Prong | __ | 7 | 0000000 | 0000000 |
With Heater | ||||||||||||
70 | Variable | 12" | 60" | 8 5/8" | 5 1/2" | 3 1/4" | 120V AC | Three Prong | __ | 7 | 0000000 | 000000 |
129 | 3 | 12" | 48" | 9 1/8" | 6 13/16" | 3 5/16" | 120V AC | Three Prong | __ | 7 | 0000000 | 000000 |
With Quiet Mode | ||||||||||||
129 | 4 | 12" | 60" | 7 5/16" | 5 1/8" | 2 3/8" | 24V DC | Three Prong | Fed. Std. Class 10, ISO Class 4 | 7 | 0000000 | 000000 |
Small enough to fit on your desktop, these create an ionized field across your immediate workspace to protect against electrostatic discharge.
Static Control | |||||||||
---|---|---|---|---|---|---|---|---|---|
Wd. | Dp. | Ht. | Wd. | Dp. | Voltage | Plug Type | Cord Lg., ft. | Each | |
12" | 16" | 5 1/2" | 5" | 2 1/2" | 120V AC | Three Prong | 7 | 0000000 | 0000000 |
An ionizing bar temporarily neutralizes static to protect against ESD (electrostatic discharge). Air knives create a sheet of high-velocity air for drying and cooling parts, wiping conveyor belts, controlling coating depth, and blowing liquids, chips, and dust from equipment. They conform to OSHA 1910.242(b) requirements for maximum air outlet pressure. Volume (dB) is measured 3 ft. from the air knife.
A power supply (sold separately) is required. It has two ports for connecting up to two air knives.
Air knives can be mounted with an adjustable arm or mounting bracket (sold separately). Knives up 6” wide can be supported with rigid pipe connected to your air supply.
Shim sets (sold separately) install in the airflow slot to adjust the flow and force of air.
Air Knives | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow | O'all | Shim Sets | ||||||||||||
Slot Wd. | Slot Dp. | Air Consumption | Volume, dB | Wd | Ht. | Dp. | Max. Temp., °F | Max. Inlet Pressure, psi | Static Neutralizing Distance | Specifications Met | Each | Each | ||
1/4 NPT Female Air Inlet | ||||||||||||||
3" | 0.002" | 12.3 cfm @ 100 psi | 86 | 4 5/8" | 1 5/8" | 1 3/8" | 165 | 250 | 6"-20 ft. | C-UL Recognized, OSHA 1910.242(b), UL Recognized | 00000000 | 0000000 | 0000000 | 000000 |
6" | 0.002" | 24.6 cfm @ 100 psi | 86 | 7 5/8" | 1 5/8" | 1 3/8" | 165 | 250 | 6"-20 ft. | C-UL Recognized, OSHA 1910.242(b), UL Recognized | 00000000 | 000000 | 0000000 | 00000 |
12" | 0.002" | 49.2 cfm @ 100 psi | 86 | 13 5/8" | 1 5/8" | 1 3/8" | 165 | 250 | 6"-20 ft. | C-UL Recognized, OSHA 1910.242(b), UL Recognized | 00000000 | 000000 | 0000000 | 00000 |
18" | 0.002" | 73.8 cfm @ 100 psi | 86 | 19 5/8" | 1 5/8" | 1 3/8" | 165 | 250 | 6"-20 ft. | C-UL Recognized, OSHA 1910.242(b), UL Recognized | 00000000 | 000000 | 0000000 | 00000 |
24" | 0.002" | 98.4 cfm @ 100 psi | 86 | 25 5/8" | 1 5/8" | 1 3/8" | 165 | 250 | 6"-20 ft. | C-UL Recognized, OSHA 1910.242(b), UL Recognized | 00000000 | 000000 | 0000000 | 00000 |
36" | 0.002" | 147.6 cfm @ 100 psi | 86 | 37 5/8" | 1 5/8" | 1 3/8" | 165 | 250 | 6"-20 ft. | C-UL Recognized, OSHA 1910.242(b), UL Recognized | 00000000 | 00000000 | 0000000 | 00000 |
O'all | First Port Mounting Holes | Second Port Mounting Holes | FIrst Port | Second Port | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Mounting Hole Dia. | Number of | Ctr.-to-Ctr. | Number of | Ctr.-to-Ctr. | Housing Material | Electrical Connection Type | Voltage | Electrical Connection Type | Voltage | Each | |
4" | 3 7/16" | 6" | 1/4", 9/32" | 4 | 2 7/8" | 4 | 5 3/8" | Steel | Plug | 120V AC | Hardwire | 230V AC | 00000000 | 0000000 |
Max. Projection | For Mounting Hole Thread Size | Mounting Fasteners Included | Features | Each | |
31" | 1/2"-13 | Yes | Two Locking Swivels | 0000000 | 0000000 |
O'all | |||||
---|---|---|---|---|---|
Wd. | Ht. | Dp. | Mounting Fasteners Included | Each | |
5" | 1" | 1" | Yes | 00000000 | 000000 |
These produce the same airflow as standard static-eliminating air knives but are quieter and use 18% less compressed air. They have an ionizing bar that temporarily neutralizes static to protect against ESD (electrostatic discharge). Air knives create a sheet of high-velocity air for drying and cooling parts, wiping conveyor belts, controlling coating depth, and blowing liquids, chips, and dust from equipment. They conform to OSHA 1910.242(b) requirements for maximum air outlet pressure. Volume (dB) is measured 3 ft. from the air knife.
A power supply (sold separately) is required. It has two ports for connecting up to two air knives.
Air knives can be mounted with an adjustable arm or mounting bracket (sold separately). Knives up 6” wide can be supported with rigid pipe connected to your air supply.
Shim sets (sold separately) install in the airflow slot to adjust the flow and force of air.
For technical drawings and 3-D models, click on a part number.
Air Knives | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow | O'all | Shim Sets | ||||||||||||
Slot Wd. | Slot Dp. | Air Consumption | Volume, dB | Wd. | Ht. | Dp. | Max. Temp., °F | Max. Inlet Pressure, psi | Static Neutralizing Distance | Specifications Met | Each | Each | ||
1/4 NPT Female Air Inlet | ||||||||||||||
3" | 0.002" | 10.5 cfm @ 100 psi | 72 | 4 5/8" | 1 7/8" | 2 1/4" | 165° | 250 | 6"-20 ft. | UL Recognized Component, C-UL Recognized Component, OSHA 1910.242(b) | 0000000 | 0000000 | 0000000 | 000000 |
6" | 0.002" | 21 cfm @ 100 psi | 72 | 7 5/8" | 1 7/8" | 2 1/4" | 165° | 250 | 6"-20 ft. | UL Recognized Component, C-UL Recognized Component, OSHA 1910.242(b) | 0000000 | 000000 | 0000000 | 00000 |
12" | 0.002" | 42 cfm @ 100 psi | 72 | 13 5/8" | 1 7/8" | 2 1/4" | 165° | 250 | 6"-20 ft. | UL Recognized Component, C-UL Recognized Component, OSHA 1910.242(b) | 0000000 | 000000 | 0000000 | 00000 |
18" | 0.002" | 63 cfm @ 100 psi | 72 | 19 5/8" | 1 7/8" | 2 1/4" | 165° | 250 | 6"-20 ft. | UL Recognized Component, C-UL Recognized Component, OSHA 1910.242(b) | 0000000 | 000000 | 0000000 | 00000 |
24" | 0.002" | 84 cfm @ 100 psi | 72 | 25 5/8" | 1 7/8" | 2 1/4" | 165° | 250 | 6"-20 ft. | UL Recognized Component, C-UL Recognized Component, OSHA 1910.242(b) | 0000000 | 000000 | 0000000 | 00000 |
36" | 0.002" | 126 cfm @ 100 psi | 72 | 37 5/8" | 1 7/8" | 2 1/4" | 165° | 250 | 6"-20 ft. | UL Recognized Component, C-UL Recognized Component, OSHA 1910.242(b) | 0000000 | 00000000 | 0000000 | 00000 |
Air Filter/Regulator for 24" and 36" Air Slot Widths | 00000000 | Each | 0000000 |
Air Filter/Regulator for 3", 6", 12", and 18" Air Slot Widths | 0000000 | Each | 000000 |
Air Filter/Regulator for 3", 6", 12", and 18" Air Slot Widths | 000000000 | Each | 00000 |
1/8 | 000000000 | Each | 00000 |
Air Filter/Regulator for 24" and 36" Air Slot Widths | 000000000 | Each | 000000 |
Air Filter/Regulator for 24" and 36" Air Slot Widths | 000000000 | Each | 000000 |
1 | 000000000 | Each | 000000 |
O'all | First Port Mounting Holes | Second Port Mounting Holes | First Port | Second Port | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Mounting Hole Dia. | Number of | Ctr.-to-Ctr. | Number of | Ctr.-to-Ctr. | Housing Material | Electrical Connection Type | Voltage | Electrical Connection Type | Voltage | Each | |
4" | 3 7/16" | 6" | 1/4", 9/32" | 4 | 2 7/8" | 4 | 5 3/8" | Steel | Plug | 120V AC | Hardwire | 230V AC | 00000000 | 0000000 |
Max. Projection | For Mounting Hole Thread Size | Mounting Fasteners Included | Features | Each | |
31" | 1/2"-13 | Yes | Two Locking Swivels | 0000000 | 0000000 |
O'all | |||||
---|---|---|---|---|---|
Wd. | Ht. | Dp. | Mounting Fasteners Included | Each | |
5" | 1" | 1" | Yes | 00000000 | 000000 |
Secure an air knife to the bracket and position where needed. Two swiveling joints allow 360° movement. Use one arm for 3" to 18" wide air knives; two arms for 24" to 42" wide air knives, and three arms for 48" wide air knives.
For technical drawings and 3-D models, click on a part number.
Max. Projection | For Mounting Hole Thread Size | Mounting Fasteners Included | Each | |
31" | 1/2"-13 | Yes | 0000000 | 0000000 |
Use one bracket for 3" to 18" wide air knives; two brackets for 24" to 42" wide air knives, and three brackets for 48" wide air knives.
O'all | |||||
---|---|---|---|---|---|
Wd. | Ht. | Dp. | Mounting Fasteners Included | Each | |
5" | 1" | 1" | Yes | 00000000 | 000000 |
Eliminate static charges and guard against ESD (electrostatic discharge) in electronics assembly and clean room applications. This blowgun requires a clean, dry air supply. A filter at the nozzle tip ensures that the air is clean. Gun conforms to OSHA 1910.242(b) requirements for maximum air outlet pressure. Volume (dB) is measured 3 ft. from the blowgun at 100 psi.
Air Inlet | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume, dB | Static Neutralizing Distance | Removes Particle Size Down To, microns | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Nozzle Tip Material | Voltage | Environmental Rating | Specifications Met | Each | |
Straight | ||||||||||||||
7 7/8" | 7.4 cfm @ 100 psi | 97 | 4"-10" | 0.01 | 100 | 1/4 | NPT | Female | Nickel Alloy | 120V AC | Fed. Std. Class 1,000; ISO Class 6 | OSHA 1910.242(b) | 00000000 | 000000000 |
Bend the stand's flexible arm to position the blowgun and it will stay in place. Step on the included foot pedal to activate airflow and static elimination. Good for electronics assembly and clean room applications, this blowgun requires a clean, dry air supply. It conforms to OSHA 1910.242(b) requirements for maximum air outlet pressure.
Air Inlet | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume | Static Neutralizing Distance | Arm Lg. | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Nozzle Tip Material | Voltage | Specifications Met | Each | |
Straight | |||||||||||||
7 7/8" | 7.4 cfm @ 100 psi | Not Rated | 1"-36" | 18" | 100 | 1/4 | NPT | Female | Nickel Alloy | 120V AC | OSHA 1910.242(b), C-UL Listed, UL Listed | 0000000 | 000000000 |
Replacement Steel Foot Pedals | 0000000 | Each | 000000 |
This blowgun provides more than three times the airflow of a standard blowgun. Good for electronics assembly and clean room applications, it eliminates static charges and guards against ESD (electrostatic discharge). Gun requires a clean, dry air supply. It conforms to OSHA 1910.242(b) requirements for maximum air outlet pressure. Volume (dB) is measured 3 ft. from the blowgun at 100 psi.
Air Inlet | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Nozzle Lg. | Air Consumption | Volume, dB | Static Neutralizing Distance | Max. Inlet Pressure, psi | Pipe Size | Thread Type | Gender | Nozzle Tip Material | Voltage | Specifications Met | Each | |
Straight | ||||||||||||
3 7/16" | 24 cfm @ 100 psi | 85 | 2"-10 ft. | 250 | 1/4 | NPT | Female | 303 Stainless Steel | 120V AC | OSHA 1910.242(b), C-UL Recognized Component, UL Recognized Component | 0000000 | 0000000 |
Replacement Blowguns with Cable | 0000000 | Each | 0000000 |