For Use With For Use With | Show |
|---|
|
For Use With For Use With | Hide |
|---|
Housing Material Housing Material |
|---|
|
Power Source Power Source |
|---|
|
Maximum Flow Rate Maximum Flow Rate |
|---|
Pump Type Pump Type |
|---|
|
Priming Type Priming Type |
|---|
|
Maximum Temperature Maximum Temperature |
|---|
|
Diaphragm Material Diaphragm Material |
|---|
|
Pump Style Pump Style |
|---|
|
Discharge Connection Style Discharge Connection Style |
|---|
|
Maximum Feet of Head Maximum Feet of Head |
|---|
|
Maximum Discharge Pressure Maximum Discharge Pressure |
|---|
|
Intake Connection Type Intake Connection Type |
|---|
|
Discharge Pipe Connection Type Discharge PipeConnection Type |
|---|
| Threaded | |
Discharge Thread Type Discharge Thread Type |
|---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
|---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
|---|
|
How to Prime Your Pump
More
How to Determine Feet of Head
More
About Process Pumps
More
316 Stainless Steel Air-Powered Transfer Pumps
for Chemicals, Fuel, and Flammable Liquids
With a 316 stainless steel housing and a PTFE diaphragm, these pumps resist a variety of acids, alkalies, and flammable liquids such as phosphoric acid, acetone, and methyl ethyl ketone (MEK). They're designed for moving large volumes of thick sludges and slurries in demanding environments. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
For technical drawings and 3-D models, click on a part number.

Max. Flow Rate, gpm | Overall | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 Max. ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
| 15 | 12 | 10 | 7 | 10,000 | 20 | 1/4 Female | 1/2 Female | 1/2 Female | 9" | 10" | 10" | 00000000 | 000000000 |
| 45 | 38 | 30 | 19 | 20,000 | 40 | 1/2 Female | 1 Female | 1 Female | 13" | 10" | 13" | 00000000 | 00000000 |
| 106 | 77 | 62 | 45 | 30,000 | 50 | 3/4 Female | 1 1/2 Female | 1 1/2 Female | 15" | 17" | 22" | 00000000 | 00000000 |
| 150 | 104 | 76 | 53 | 40,000 | 100 | 3/4 Female | 2 Female | 2 Female | 15" | 17" | 26" | 00000000 | 00000000 |
| 235 | 174 | 127 | 90 | 50,000 | 140 | 3/4 Female | 3 Female | 3 Female | 17" | 20" | 32" | 00000000 | 000000000 |
| Air-Motor Maintenance Kit for 41655K28 | 0000000 | Each | 0000000 |
| Fluid-Side Maintenance Kit for 41655K28 | 0000000 | Each | 000000 |
| Air-Motor Maintenance Kit for 41655K29, 41655K31, 41655K32 | 0000000 | Each | 000000 |
| Fluid-Side Maintenance Kit for 41655K29 | 0000000 | Each | 00000000 |
| Fluid-Side Maintenance Kit for 41655K31 | 0000000 | Each | 00000000 |
| Fluid-Side Maintenance Kit for 41655K32 | 0000000 | Each | 00000000 |
| Air-Motor Maintenance Kit for 41655K27 | 0000000 | Each | 00000000 |
| Fluid-Side Maintenance Kit for 41655K27 | 0000000 | Each | 000000 |
Aluminum Air-Powered Transfer Pumps for Oil, Chemicals, and Fuel
These pumps have a PTFE diaphragm compatible with oil, fuel, and chemicals such as mineral spirits, methyl ethyl ketone (MEK), and xylene. They have a rugged aluminum housing for moving large volumes of thick sludges and slurries in demanding environments. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
Fluid-side maintenance kits include diaphragms, check valve balls, and seals.
Air-motor maintenance kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.

Max. Flow Rate, gpm | Overall | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connection (NPT) | Discharge Pipe Connection (NPT) | Lg. | Wd. | Ht. | Each | |
289 Max. ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
| 15 | 12 | 10 | 7 | 10,000 | 20 | 1/4 Female | 1/2 Female, 1/2 Female | 1/2 Female, 1/2 Female | 9" | 10" | 12" | 0000000 | 000000000 |
| 45 | 38 | 30 | 19 | 20,000 | 40 | 1/2 Female | 1 Female | 1 Female | 13" | 10" | 13" | 0000000 | 00000000 |
| 106 | 77 | 62 | 45 | 30,000 | 50 | 3/4 Female | 1 1/2 Female | 1 1/2 Female | 15" | 17" | 22" | 0000000 | 00000000 |
| 150 | 104 | 76 | 53 | 40,000 | 100 | 3/4 Female | 2 Female | 2 Female | 15" | 17" | 26" | 0000000 | 00000000 |
| 235 | 174 | 127 | 90 | 50,000 | 140 | 3/4 Female | 3 Female | 3 Female | 17" | 20" | 32" | 0000000 | 00000000 |
| Fluid-Side Maintenance Kit for 9948K21 | 0000000 | Each | 000000000 |
| Air-Motor Maintenance Kit for 9948K21, 9948K23 and 9948K24 | 0000000 | Each | 000000 |
| Fluid-Side Maintenance Kit for 9948K16 | 0000000 | Each | 000000 |
| Air-Motor Maintenance Kit for 9948K16 | 0000000 | Each | 00000000 |
| Air-Motor Maintenance Kit for 9948K19 | 0000000 | Each | 000000 |
| Fluid-Side Maintenance Kit for 9948K19 | 0000000 | Each | 000000 |
| Fluid-Side Maintenance Kit for 9948K24 | 0000000 | Each | 00000000 |
| Fluid-Side Maintenance Kit for 9948K23 | 0000000 | Each | 00000000 |
Plastic Air-Powered Transfer Pumps for Fuel and Flammable Liquids
These pumps can be grounded to dissipate static electricity and are rated for use with flammable liquids such as gasoline, kerosene, isopropyl alcohol, and mineral spirits. All are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps are submersible and can run dry.

Max. Flow Rate, gpm | Overall | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Flow Rate, gpm | @ 80 ft. of Head | @ 120 ft. of Head | @ 160 ft. of Head | Max. Viscosity | Air Consumption, cfm | Air Connection (NPT) | Intake Pipe Connections (NPT) | Discharge Pipe Connections (NPT) | Lg. | Wd. | Ht. | Each | |
288 ft. of Head—125 psi Max. Discharge Pressure | |||||||||||||
| 5.3 | 3.2 | 2.3 | 1.7 | Not Rated | 6.1 | 1/4 Female | 1/4 Female, 3/4 Male | 1/4 Female, 3/4 Male | 7" | 5" | 7" | 0000000 | 0000000 |