McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    22 Products

    Line-Voltage Thermostats

    Image of Product. Front orientation. Thermostats. Line-Voltage Thermostats, For Air Conditioners and Heaters.
    Image of Product. For Heaters. Front orientation. 120V AC to 277V AC. Line-Voltage Thermostats.

    For Air

    Conditioners

    and Heaters

    For Heaters

    Regulate line-voltage HVAC systems.
    For Heaters—Thermostats for heaters mount to a surface-mount outlet box.
    Cannot Be Sold To—Energy efficiency requirements restrict sales to the listed jurisdictions/areas.
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Display
    Type
    Certification
    Cannot Be
    Sold To
    Each
    For Air Conditioners and Heaters
     
    Dial Control
    24 to 2772240 to 90SPDT
    Hardwire4 3/4"3"1 3/8"NoYesAnalogUL Listed
    Colorado00000000000000
     
    For Heaters
     
    Dial Control
    120 to 2772250 to 90SPST
    Hardwire4 1/2"2 3/4"1 1/2"NoNoAnalogETL Listed
    Colorado0000000000000
    120 to 2772250 to 90DPST
    Hardwire4 1/2"2 3/4"1 1/2"NoNoAnalogETL Listed
    Colorado0000000000000
     

    Remote-Sensing Line-Voltage Thermostats

    Image of Product. Style A. Front orientation. Thermostats. Remote-Sensing Line-Voltage Thermostats, For Air Conditioners and Heaters, Dial Control, Style A.
    Image of Product. Style B. Front orientation. Thermostats. Remote-Sensing Line-Voltage Thermostats, For Air Conditioners and Heaters, Dial Control, Style B.

    Style A

    Style B

    Place sensor in enclosures or different rooms than the rest of the thermostat to control temperature from outside the space. Thermostats work with line-voltage HVAC systems.
    Overall
    Style
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    Sensor
    Cord Lg., ft.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Display
    Type
    Certification
    Each
    For Air Conditioners and Heaters
     
    Dial Control
    A120 to 27722-30 to 100SPDT
    Hardwire5"2 1/4"1 5/8"8NoNo1/8"AnalogUL Listed
    00000000000000
    B120 to 2772240 to 110SPDT
    Hardwire5 1/2"2 1/8"2 5/8"2NoNo1/8"AnalogUL Listed
    0000000000000
     

    Programmable Line-Voltage Thermostats

    Image of Product. Front orientation. Thermostats. Programmable Line-Voltage Thermostats.
    Set these thermostats to adjust the temperature at certain times each day. They regulate heaters that use direct electrical power, such as baseboard and wall heaters.
    For
    System
    Overall
    Type
    Efficiency
    Program
    Function
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Display
    Type
    Each
    For Heaters
     
    Push-Button Control
    ElectricSingle StageDaily1201640 to 86SPST
    Hardwire4 7/8"2 3/4"7/8"NoYesDigital00000000000000
    ElectricSingle StageDaily2401540 to 86DPST
    Hardwire4 7/8"2 3/4"7/8"NoYesDigital0000000000000
    ElectricSingle StageDaily2401640 to 86SPST
    Hardwire4 7/8"2 3/4"7/8"NoYesDigital0000000000000
     

    Tamper-Resistant Line-Voltage Thermostats

    Image of Product. Front orientation. Thermostats. Tamper-Resistant Line-Voltage Thermostats.
    Image of Product. Thermostat with Tamper-Resistant Guard Removed. Front orientation. Thermostats. Tamper-Resistant Line-Voltage Thermostats, For Heaters, Dial Control.

    Thermostat with

    Tamper-Resistant

    Guard Removed

    A built-in guard prevents accidental changes and other tampering and protects these thermostats from damage. These thermostats regulate the temperature in HVAC systems that use direct electrical power. They’re often used with baseboard and wall heaters.
    DPST—DPST (double pole, single throw) thermostats control two circuits, so they have an “off” setting that cuts power to the thermostat. As a result, they’re more energy efficient and slightly safer than SPST (single pole, single throw) thermostats, which stay at a low setting instead of turning off completely.
    Cannot Be Sold To—Energy efficiency requirements restrict sales to the listed jurisdictions/areas.
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Features
    Display
    Type
    Certification
    Cannot Be
    Sold To
    Each
    For Heaters
     
    Dial Control
    120 to 2772250 to 90SPST
    Hardwire4 9/16"2 13/16"1 3/4"NoNoTamper-Resistant GuardAnalogETL Listed
    Colorado0000000000000
    120 to 2772250 to 90DPST
    Hardwire4 9/16"2 13/16"1 3/4"NoNoTamper-Resistant GuardAnalogETL Listed
    Colorado000000000000
     

    Plug-In Line-Voltage Thermostats

    Image of Product. Front orientation. Thermostats. Plug-In Line-Voltage Thermostats.
    Plug in the thermostat, then plug your line-voltage heater into the socket on the thermostat's plug. Use the included metal hanger for mounting.
    Electrical
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Cord Lg.,
    ft.
    Electrical
    Connection Type
    Connection
    No. of
    Blades
    Ht.
    Wd.
    Dp.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Display
    Type
    Certification
    Each
    For Heaters
     
    Dial Control
    1201340 to 90SPST
    6Plug InStraight Blade35 1/2"2 1/8"2 5/8"NoNoAnalogUL Listed
    0000000000000
     

    DIN-Rail Mount Remote-Sensing Line-Voltage Thermostats

    Image of Product. Front orientation. Thermostats. DIN-Rail Mount Remote-Sensing Line-Voltage Thermostats.
    Image of Product. Replacement Sensor and Cable. Front orientation. DIN-Rail Mount Remote-Sensing Line-Voltage Thermostats.

    Replacement Sensor and

    Cable

    Place sensor in enclosures or different rooms than the rest of the thermostat to control temperature from outside the space. Thermostat works with line-voltage HVAC systems.
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    Sensor
    Cord Lg., ft.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Display
    Type
    Certification
    Each
    For Air Conditioners and Heaters
     
    Keypad Control
    120 to 24015-30 to 212SPDT
    Hardwire5"2 3/8"2 3/8"6NoNo1/4"DigitalUL Listed
    00000000000000
     
    Temperature and Humidity Sensors

    Multispeed Line-Voltage Thermostats

    Image of Product. Front orientation. Thermostats. Multispeed Line-Voltage Thermostats.
    Control one- and two-speed line-voltage HVAC systems. Set the thermostat to activate the device’s second speed when the temperature surpasses the setting for the first speed by 3.6° F to 9° F.
    Cannot Be Sold To—Energy efficiency requirements restrict sales to the listed jurisdictions/areas.
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    Temp. Differential,
    ° F
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Display
    Type
    Enclosure
    Rating
    Certification
    Cannot Be
    Sold To
    Each
    For Air Conditioners and Heaters
     
    Dial Control
    24 to 2501532 to 140SPDT
    Hardwire6"2 3/4"3 3/8"3.6 to 9YesYesAnalogIP65, NEMA 4
    CE Marked
    Colorado00000000000000
     

    Wet-Location Line-Voltage Thermostats

    Image of Product. Hardwire. Front orientation. Thermostats. Wet-Location Line-Voltage Thermostats, For Air Conditioners and Heaters, Dial Control, Hardwire.
    Image of Product. Plug. Front orientation. Thermostats. Wet-Location Line-Voltage Thermostats, For Heaters, Dial Control, Plug In.

    Hardwire

    Plug

    Regulate temperatures in wet locations for HVAC systems that use direct electrical power, such as air conditioners and heaters. These thermostats have a sealed housing to protect against dripping, splashing, and falling liquids.
    Plug In—Thermostats with a plug are easy to connect. Plug in the thermostat and then plug your heater into the thermostat.
    Cannot Be Sold To—Energy efficiency requirements restrict sales to the listed jurisdictions/areas.
    Electrical
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Cord Lg.,
    ft.
    Electrical
    Connection Type
    Connection
    No. of
    Blades
    Ht.
    Wd.
    Dp.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Display
    Type
    Certification
    UL File
    No.
    Cannot Be
    Sold To
    Each
    For Air Conditioners and Heaters
     
    Dial Control
    120 to 2772230 to 110SPDT
    Hardwire7 3/4"3"2 5/8"YesNo7/32"AnalogC-UL Listed, UL Listed
    E313212Colorado00000000000000
    120 to 2772230 to 110DPDT
    Hardwire7 3/4"3"2 5/8"YesNo7/32"AnalogC-UL Listed, UL Listed
    E313212Colorado0000000000000
     
    For Heaters
     
    Dial Control
    1251030 to 110SPDT
    7Plug InStraight Blade37 3/4"3"2 5/8"YesNo7/32"AnalogC-UL Listed, UL Listed
    E313212Colorado0000000000000
     

    Hazardous Location Line-Voltage Thermostats

    Image of Product. Front orientation. Thermostats. Hazardous Location Line-Voltage Thermostats.
    Use to regulate line-voltage HVAC systems where flammable gases, vapors, and dust are present.
    Hazardous Location Rating—Thermostats are rated Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G.
    Cannot Be Sold To—Energy efficiency requirements restrict sales to the listed jurisdictions/areas.
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Display
    Type
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    Cannot Be
    Sold To
    Each
    For Air Conditioners and Heaters
     
    Dial Control
    24 to 2772250 to 90SPDT
    Hardwire5 3/4"6 3/8"5 5/8"NoNo1/4"AnalogNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7
    CSA Certified, UL Listed
    Colorado00000000000000
    24 to 2772250 to 90DPDT
    Hardwire5 3/4"6 3/8"5 5/8"NoNo1/4"AnalogNEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7
    CSA Certified, UL Listed
    Colorado0000000000000
     

    Line-Voltage Thermostats with Thermowell

    Image of Product. Front orientation. Thermostats. Line-Voltage Thermostats with Thermowell.
    Commonly used with line-voltage hydronic heaters, this thermostat senses the temperature of liquids. The thermowell protects the sensor.
    Cannot Be Sold To—Energy efficiency requirements restrict sales to the listed jurisdictions/areas.
    Overall
    Thermowell
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    For Use
    Outdoors
    Thread
    Type
    Pipe
    Size
    Mounting Fasteners
    Included
    Display
    Type
    Certification
    Cannot Be
    Sold To
    Each
    For Air Conditioners and Heaters
     
    Dial Control
    120 to 24010100 to 240SPDT
    Hardwire4 1/2"2 1/4"1 7/8"NoNPT
    1/2
    NoAnalogUL Listed
    Colorado0000000000000
     

    Remote-Sensing Line-Voltage Thermostats with Thermowell

    Image of Product. Front orientation. Thermostats. Remote-Sensing Line-Voltage Thermostats with Thermowell.
    Commonly used with line-voltage hydronic heaters, this thermostat senses the temperature of liquids at a distance using the remote sensor. The thermowell protects the sensor.
    Cannot Be Sold To—Energy efficiency requirements restrict sales to the listed jurisdictions/areas.
    Overall
    Thermowell
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    Sensor
    Cord Lg., ft.
    For Use
    Outdoors
    Thread
    Type
    Pipe
    Size
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Display
    Type
    Certification
    Cannot Be
    Sold To
    Each
    For Air Conditioners and Heaters
     
    Dial Control
    120 to 24010100 to 240SPDT
    Hardwire4 1/2"2 1/4"1 7/8"8NoNPT
    1/2
    No1/4"AnalogUL Listed
    Colorado0000000000000
     

    Remote-Sensing Hazardous Location Line-Voltage Thermostats

    Image of Product. Front orientation. Thermostats. Remote-Sensing Hazardous Location Line-Voltage Thermostats.
    Place sensor in enclosures or different rooms than the rest of the thermostat to control temperature from outside the space. Use to regulate line-voltage HVAC systems where flammable gases, vapors, and dust are present.
    Hazardous Location Rating—Thermostats are rated Class I, Divisions 1 and 2, Group D; and Class II, Divisions 1 and 2, Groups E, F, and G.
    Overall
    Voltage,
    V AC
    Current,
    amp
    Temp. Setting,
    ° F
    Switch
    Designation
    Electrical
    Connection Type
    Ht.
    Wd.
    Dp.
    Sensor
    Cord Lg., ft.
    For Use
    Outdoors
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Display
    Type
    Hazardous Location Rating
    Enclosure
    Rating
    Certification
    Each
    For Air Conditioners and Heaters
     
    Dial Control
    120 to 2772220 to 80SPDT
    Hardwire5 7/8"3"3 1/4"6NoNo3/8"AnalogNEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 7, NEMA 9
    CSA Certified, UL Listed
    00000000000000
     
    back to top