Filter by
Performance
Compressive Strength Range
Dielectric Strength
Impact Strength
Tensile Strength
Hardness Rating
Export Control Classification Number (ECCN)
RoHS
DFARS Specialty Metals
Reinforcement Material
Flexural Strength
Water Absorption
About Composites
Compare our offering of composites to find the right material for you.
Arc-Resistant Garolite G-9 Sheets
Temp. | 12" × 12" | 24" × 24" | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
Min. | Max., ° F | Tensile Strength, psi | Impact Strength, ft·lbf/in | Hardness | For Use Outdoors | Flammability Rating | Each | Each | ||||
1/32" Thick (-0.005" to 0.005") | ||||||||||||
Brown | ||||||||||||
| Not Rated | 280 | 39,000 | 9 to 22.7 | Rockwell M90 (Hard) | No | — | 8661K118 | 000000 | 8661K119 | 000000 | ||
1/16" Thick (-0.008" to 0.008") | ||||||||||||
Brown | ||||||||||||
| Not Rated | 280 | 39,000 | 9 to 22.7 | Rockwell M90 (Hard) | No | UL 94 V-0 | 8661K121 | 00000 | 8661K161 | 00000 | ||
1/8" Thick (-0.012" to 0.012") | ||||||||||||
Brown | ||||||||||||
| Not Rated | 280 | 39,000 | 9 to 22.7 | Rockwell M90 (Hard) | No | UL 94 V-0 | 8661K122 | 00000 | 8661K162 | 000000 | ||
1/4" Thick (-0.022" to 0.022") | ||||||||||||
Brown | ||||||||||||
| Not Rated | 280 | 39,000 | 9 to 22.7 | Rockwell M90 (Hard) | No | UL 94 V-0 | 8661K124 | 00000 | 8661K164 | 000000 | ||
Arc-Resistant Garolite G-9 Rods
Temp., ° F | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dia. | Dia. Tolerance | Min. | Max. | Tensile Strength, psi | Impact Strength, ft·lbf/in | Hardness | For Use Outdoors | Flammability Rating | 1 ft. | 4 ft. | |||
Gray | |||||||||||||
| 1/16" | -0.001" to 0.001" | -40 | 280 | 39,000 | 9 to 22.7 | Rockwell M115 (Extra Hard) | No | UL 94 V-0 | 8534K12 | — | 000000 | ||
| 1/8" | -0.001" to 0.001" | -40 | 280 | 39,000 | 9 to 22.7 | Rockwell M115 (Extra Hard) | No | UL 94 V-0 | 8534K14 | — | 00000 | ||
| 1/4" | -0.001" to 0.001" | -40 | 280 | 39,000 | 9 to 22.7 | Rockwell M115 (Extra Hard) | No | UL 94 V-0 | 8534K17 | — | 00000 | ||
| 5/16" | -0.001" to 0.001" | -40 | 280 | 39,000 | 9 to 22.7 | Rockwell M115 (Extra Hard) | No | UL 94 V-0 | 8534K41 | 00000 | 00000 | ||
| 3/8" | -0.001" to 0.001" | -40 | 280 | 39,000 | 9 to 22.7 | Rockwell M115 (Extra Hard) | No | UL 94 V-0 | 8534K42 | 0000 | 00000 | ||
| 1/2" | -0.001" to 0.001" | -40 | 280 | 39,000 | 9 to 22.7 | Rockwell M115 (Extra Hard) | No | UL 94 V-0 | 8534K51 | 00000 | 00000 | ||
| 5/8" | -0.001" to 0.001" | -40 | 280 | 39,000 | 9 to 22.7 | Rockwell M115 (Extra Hard) | No | UL 94 V-0 | 8534K52 | 00000 | 00000 | ||
| 3/4" | -0.001" to 0.001" | -40 | 280 | 39,000 | 9 to 22.7 | Rockwell M115 (Extra Hard) | No | UL 94 V-0 | 8534K53 | 00000 | 00000 | ||
| 1" | -0.001" to 0.001" | -40 | 280 | 39,000 | 9 to 22.7 | Rockwell M115 (Extra Hard) | No | UL 94 V-0 | 8534K54 | 00000 | 00000 | ||
Arc-Resistant Garolite G-9 Angles
Outside | Inside | Temp. | 36" | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Wd. Tolerance | Ht. | Ht. Tolerance | Wd. | Ht. | Min. | Max., ° F | Tensile Strength, psi | Impact Strength, ft·lbf/in | Hardness | For Use Outdoors | Flammability Rating | Each | |||
1/8" Thick Wall (-0.03" to 0.03") | ||||||||||||||||
Gray | ||||||||||||||||
| 1" | -0.125" to 0.125" | 1" | -0.125" to 0.125" | 7/8" | 7/8" | Not Rated | 280 | 30,000 to 37,000 | 5.5 to 7 | Rockwell M120 (Extra Hard) | Yes | UL 94 V-0 | 6780N111 | 0000000 | ||
| 1 1/2" | -0.187" to 0.187" | 1 1/2" | -0.187" to 0.187" | 1 3/8" | 1 3/8" | Not Rated | 280 | 30,000 to 37,000 | 5.5 to 7 | Rockwell M120 (Extra Hard) | Yes | UL 94 V-0 | 6780N112 | 000000 | ||
| 2" | -0.25" to 0.25" | 2" | -0.25" to 0.25" | 1 7/8" | 1 7/8" | Not Rated | 280 | 30,000 to 37,000 | 5.5 to 7 | Rockwell M120 (Extra Hard) | Yes | UL 94 V-0 | 6780N113 | 000000 | ||
3/16" Thick Wall (-0.04" to 0.04") | ||||||||||||||||
Gray | ||||||||||||||||
| 1" | -0.125" to 0.125" | 1" | -0.125" to 0.125" | 13/16" | 13/16" | Not Rated | 280 | 30,000 to 37,000 | 5.5 to 7 | Rockwell M120 (Extra Hard) | Yes | UL 94 V-0 | 6780N114 | 000000 | ||
| 1 1/2" | -0.187" to 0.187" | 1 1/2" | -0.187" to 0.187" | 1 5/16" | 1 5/16" | Not Rated | 280 | 30,000 to 37,000 | 5.5 to 7 | Rockwell M120 (Extra Hard) | Yes | UL 94 V-0 | 6780N115 | 000000 | ||
| 2" | -0.25" to 0.25" | 2" | -0.25" to 0.25" | 1 13/16" | 1 13/16" | Not Rated | 280 | 30,000 to 37,000 | 5.5 to 7 | Rockwell M120 (Extra Hard) | Yes | UL 94 V-0 | 6780N116 | 000000 | ||
1/4" Thick Wall (-0.05" to 0.05") | ||||||||||||||||
Gray | ||||||||||||||||
| 1" | -0.125" to 0.125" | 1" | -0.125" to 0.125" | 3/4" | 3/4" | Not Rated | 280 | 30,000 to 37,000 | 5.5 to 7 | Rockwell M120 (Extra Hard) | Yes | UL 94 V-0 | 6780N117 | 000000 | ||
| 1 1/2" | -0.187" to 0.187" | 1 1/2" | -0.187" to 0.187" | 1 1/4" | 1 1/4" | Not Rated | 280 | 30,000 to 37,000 | 5.5 to 7 | Rockwell M120 (Extra Hard) | Yes | UL 94 V-0 | 6780N118 | 000000 | ||
| 2" | -0.25" to 0.25" | 2" | -0.25" to 0.25" | 1 3/4" | 1 3/4" | Not Rated | 280 | 30,000 to 37,000 | 5.5 to 7 | Rockwell M120 (Extra Hard) | Yes | UL 94 V-0 | 6780N119 | 000000 | ||