For Removing For Removing |
---|
|
For Use On For Use On |
---|
Volume Volume |
---|
|
Control Type Control Type |
---|
|
Electrical Connection Type Electrical Connection Type |
---|
|
Specifications Met Specifications Met |
---|
|
More
Produce a stream of air down a doorway or other opening to keep out dust, dirt, insects, and fumes while allowing personnel to pass through. These air curtains have wire leads for hardwiring.
Air curtains with disinfecting UV bulbs sanitize air. A UV-C bulb—commonly used in waiting rooms, test labs, and receiving areas—kills up to 99.99% of contaminants such as bacteria, viruses, and mold. A UV-V bulb—commonly found in food-processing facilities, waste areas, and bathrooms—reduces odors and gases such as smoke and VOC fumes. The bulbs also help prevent buildup of bacteria inside air curtains, so germs aren’t blown outwards.
Optional door switches turn air curtains on when the door is opened and off when it is closed.
Air Curtains | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Frame Opening | O'all | Replacement Sets of UV Bulbs | ||||||||||||||
Wd. | Ht. | Wd. | Ht. | Dp. | Airflow, cfm | Volume | No. of Motors | Power per Motor, hp | Current, A | Specifications Met | For Use Outdoors | Temp. Range, °F | Each | Each | ||
120V AC | ||||||||||||||||
36" | 120" | 36" | 10 5/8" | 24 1/8" | 1,379 | 66 dB @ 10 ft. | 1 | 1/2 | 5.1 | ETL Listed | No | 0° to 100° | 00000000 | 000000000 | 00000000 | 0000000 |
42" | 120" | 42" | 10 5/8" | 24 1/8" | 1,418 | 66 dB @ 10 ft. | 1 | 1/2 | 5.1 | ETL Listed | No | 0° to 100° | 00000000 | 00000000 | 00000000 | 000000 |
48" | 120" | 48" | 10 5/8" | 24 1/8" | 1,442 | 66 dB @ 10 ft. | 1 | 1/2 | 5.1 | ETL Listed | No | 0° to 100° | 00000000 | 00000000 | 00000000 | 000000 |
60" | 120" | 60" | 10 5/8" | 24 1/8" | 2,700 | 68 dB @ 10 ft. | 2 | 1/2 | 10.2 | ETL Listed | No | 0° to 100° | 00000000 | 00000000 | 00000000 | 000000 |
72" | 120" | 72" | 10 5/8" | 24 1/8" | 2,758 | 68 dB @ 10 ft. | 2 | 1/2 | 10.2 | ETL Listed | No | 0° to 100° | 00000000 | 00000000 | 00000000 | 000000 |
Optional Door Switch | 000000 | Each | 000000 |
Sized for use in coolers, offices, and other locations with limited clearance above doorways. These air curtains produce a stream of air down a doorway or other opening to keep out dust, dirt, insects, and fumes while allowing personnel to pass through.
Air curtains with disinfecting UV bulbs sanitize air. A UV-C bulb—commonly used in waiting rooms, test labs, and receiving areas—kills up to 99.99% of contaminants such as bacteria, viruses, and mold. A UV-V bulb—commonly found in food-processing facilities, waste areas, and bathrooms—reduces odors and gases such as smoke and VOC fumes. The bulbs also help prevent buildup of bacteria inside air curtains, so germs aren’t blown outwards.
Optional door switches turn air curtains on when the door is opened and off when it is closed.
Air Curtains | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Frame Opening | O'all | Replacement Sets of UV Bulbs | ||||||||||||||||
Wd. | Ht. | Wd. | Ht. | Dp. | Airflow, cfm | Volume | No. of Motors | Power per Motor, hp | Current, A | Plug Type | Cord Lg., ft. | Specifications Met | For Use Outdoors | Temp. Range, °F | Each | Each | ||
Single-Phase Air Curtains with Disinfecting UV Bulbs | ||||||||||||||||||
120V AC | ||||||||||||||||||
36" | 96" | 36" | 8" | 13 3/4" | 900 | 49 dB @ 10 ft. | 1 | 1/6 | 2.4 | Three Prong | 6 | ETL Listed | No | 0° to 100° | 00000000 | 000000000 | 00000000 | 0000000 |
48" | 96" | 48" | 8" | 13 3/4" | 1,200 | 52 dB @ 10 ft. | 1 | 1/6 | 2.4 | Three Prong | 6 | ETL Listed | No | 0° to 100° | 00000000 | 00000000 | 00000000 | 000000 |
60" | 96" | 60" | 8" | 13 3/4" | 1,500 | 53 dB @ 10 ft. | 1 | 1/6 | 2.6 | Three Prong | 6 | ETL Listed | No | 0° to 100° | 00000000 | 00000000 | 00000000 | 000000 |
72" | 96" | 72" | 8" | 13 3/4" | 1,800 | 53 dB @ 10 ft. | 1 | 1/6 | 2.6 | Three Prong | 6 | ETL Listed | No | 0° to 100° | 00000000 | 00000000 | 00000000 | 000000 |
Optional Door Switch | 000000 | Each | 000000 |
Remove viruses, bacteria, dust, and other particles from the air. First, the UV-C light bulbs in these cleaners kill airborne pathogens with UV Germicidal Irradiation (UVGI). Each bulb has been individually tested to ensure that it doesn’t produce harmful ozone. Then, a series of filters remove microbes from the air. To protect more advanced filters, a prefilter traps larger particles. A HEPA filter then captures particles as small as 0.3 microns. With the equivalent of a MERV 17 filter rating, HEPA filters are often used to purify air in hospitals. After the cleaners disinfect and filter air, a multispeed blower circulates the clean air throughout your space.
Cleaners with a carbon filter eliminate odors and fumes. They’re commonly used to absorb harmful vapors in laboratories. These cleaners cannot be sold to California due to energy efficiency requirements.
Freestanding air cleaners are easily moved from room to room, allowing you to use them wherever they’re needed at a moment’s notice. Cleaners that are portable include eye bolts for mounting them to a ceiling with a chain. They perform up to six air changeovers per hour in a 30 ft. × 30 ft. space. Cleaners that are mobile have wheels to make them easier to move. CARB compliant, they’re tested for electrical safety and ozone-emission concentration limits. Their prefilter uses magnesium oxide, zinc oxide, and titanium dioxide to neutralize the chemicals in vapors and fumes, instead of simply absorbing them like carbon filters. These cleaners complete between three and five air changeovers per hour in a 1,000 sq. ft. space. Indicator lights alert you when it’s time to replace their air filters and UV bulbs.
Ceiling-mount air cleaners rest flush with your ceiling, blending into the room without taking up floor space. Install them on a 24 in. × 48 in. ceiling tile with the mounting frame, or use a chain and the included eyebolts to mount them elsewhere. Set different airflow patterns with the adjustable louver blades. A hinged panel lets you access and replace filters without having to remove these cleaners from the ceiling. Ceiling-mount air cleaners provide up to six air changeovers per hour in a 27 ft. × 27 ft. space.
Air Cleaners | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement HEPA/Odor-Removal Filters | Replacement Bulbs | ||||||||||||
Airflow, cfm | Volume | Voltage | Current, A | Length | Height | Width | Housing Material | Cannot Be Sold To | Each | Each | Each | |||
White Housing—With Eyebolts, Reusable Carbon Filter, Reusable HEPA Filter, Reusable Prefilter | ||||||||||||||
750 | 71 dB @ 15 ft. | 120V AC | 5.5 | 19" | 22" | 21" | Steel | CA | 0000000 | 000000000 | 0000000 | 0000000 | 0000000 | 000000 |
Black Housing—With Eyebolts, Reusable Carbon Filter, Reusable HEPA Filter, Reusable Prefilter | ||||||||||||||
750 | 71 dB @ 15 ft. | 120V AC | 5.5 | 19" | 22" | 21" | Steel | CA | 0000000 | 00000000 | 0000000 | 000000 | 0000000 | 00000 |
Air Cleaners | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement HEPA Filters | Replacement Prefilters | Replacement Bulbs | ||||||||||||||
Airflow, cfm | Volume | Voltage | Current, A | Length | Height | Width | Housing Material | Features | Specifications Met | Each | Each | Each | Each | ||||
White Housing—With Reusable HEPA Filter, Reusable Prefilter, Thumb Screws | |||||||||||||||||
250 | 62 dB @ 15 ft. | 120V AC | 1 | 15" | 22" | 15 1/2" | Steel | Indicator Lights, Wheels | CARB Compliant | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 000000 |
Air Cleaners | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | For Ceiling Tile | Replacement Prefilters | Replacement Bulbs | |||||||||||||
Airflow, cfm | Volume | Voltage | Current, A | Length | Height | Width | Length | Width | Housing Material | Cannot Be Sold To | Each | Each | Each | |||
White Housing—With Eyebolts, Reusable Carbon Filter, Reusable HEPA Filter, Reusable Prefilter | ||||||||||||||||
600 | 49 dB @ 15 ft. | 120V AC | 3.3 | 23 3/4" | 11" | 47 3/4" | 24" | 48" | Steel | CA | 0000000 | 000000000 | 0000000 | 000000 | 0000000 | 000000 |
Black Housing—With Eyebolts, Reusable Carbon Filter, Reusable HEPA Filter, Reusable Prefilter | ||||||||||||||||
600 | 49 dB @ 15 ft. | 120V AC | 3.3 | 23 3/4" | 11" | 47 3/4" | 24" | 48" | Steel | CA | 0000000 | 00000000 | 0000000 | 00000 | 0000000 | 00000 |
Use in bioremediating (also known as self-cleaning) parts washers. Microbes in the solution consume and destroy grease and oil to prevent it from building up in the solution. Dilute with water to make 19 gallons of solution.
Solution Type | Container Size, gal. | For Use On | For Removing | Max. Temp., °F | Each | |
Liquid Concentrate | ||||||
---|---|---|---|---|---|---|
Water Based | 1 | Aluminum, Brass, Bronze, Copper, Glass, Iron, Plastic, Stainless Steel, Steel, Titanium | Asphalt, Carbon Residue, Fingerprints, Grease, Lapping Compounds, Oil, Paint, Wax | 120° | 0000000 | 0000000 |
The microbes in these clay-based cleaners devour oil, grease, and organic waste and only leave behind carbon dioxide, water, and natural fats. Use these cleaners for oil spills or inside grease traps, septic tanks, and storm drains. Mix with water to activate.
These mild detergents contain bacteria that consume and break down grease and oil, rather than rinsing it into pipes that can clog. For use on hard, nonporous surfaces.
Container | |||||||
---|---|---|---|---|---|---|---|
Type | Size | Composition | Harshness | For Use On | For Removing | Each | |
Liquid | |||||||
Bottle | 32 oz. | Water Based | Mild | Aluminum, Ceramic, Chrome, Concrete, Galvanized Steel, Iron, Stainless Steel, Steel | Dirt, Grease/Oil | 000000 | 000000 |
Jug | 1 gal. | Water Based | Mild | Aluminum, Ceramic, Chrome, Concrete, Galvanized Steel, Iron, Stainless Steel, Steel | Dirt, Grease/Oil | 000000 | 00000 |