For Use With For Use With |
|---|
Pump Type Pump Type |
|---|
|
Maximum Flow Rate Maximum Flow Rate |
|---|
Duty Cycle Duty Cycle |
|---|
|
Maximum Feet of Head Maximum Feet of Head |
|---|
|
Pump Style Pump Style |
|---|
|
Current Current |
|---|
Overall Height Overall Height |
|---|
|
|
|
Flow Rate Flow Rate |
|---|
|
Power Power |
|---|
|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
|---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
|---|
|
How to Prime Your Pump
More
How to Determine Feet of Head
More
About Process Pumps
More
About Sump, Water-Removal, Condensate, and Submersible Pumps
More
About Drum Pumps
More
Harsh-Environment Compact Constant-Flow-Rate Pumps for Water and Oil

An aluminum enclosure around the motor provides protection in dusty and dirty environments. Designed to fit into small equipment, these pumps have miniature gears and a subfractional horsepower motor for low-flow applications. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Intake | Discharge | Overall | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Flow Rate | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Tube Connection Type | Gender | For Tube ID | Tube Connection Type | Gender | For Tube ID | Lg. | Wd. | Ht. | Each | |
12V DC—Without Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
| 0.61 gpm (78 oz./min.) | 20 | 800 | 10° to 180° | Subfractional | 2.2 | Barbed | Male | 3/16" | Barbed | Male | 3/16" | 4" | 1 3/4" | 2 1/2" | 0000000 | 000000 |
24V DC—Without Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
| 0.61 gpm (78 oz./min.) | 20 | 800 | 10° to 180° | Subfractional | 1.4 | Barbed | Male | 3/16" | Barbed | Male | 3/16" | 4" | 1 3/4" | 2 1/2" | 0000000 | 00000 |
Compact Constant-Flow-Rate Pumps for Water and Oil

Designed to fit into small equipment, these pumps have miniature gears and a subfractional horsepower motor for low-flow applications. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Intake | Discharge | Overall | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Flow Rate | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Tube Connection Type | Gender | For Tube ID | Tube Connection Type | Gender | For Tube ID | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
| 0.43 gpm (55 oz./min.) | 20 | 800 | 10° to 180° | Subfractional | 1.5 | Barbed | Male | 3/16" | Barbed | Male | 3/16" | 4 3/8" | 3" | 3 3/4" | 0000000 | 0000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
| 0.43 gpm (55 oz./min.) | 20 | 800 | 10° to 180° | Subfractional | 1.5 | Barbed | Male | 3/16" | Barbed | Male | 3/16" | 4 3/8" | 3" | 3 3/4" | 0000000 | 000000 |
Compact Air-Powered Transfer Pumps
Small enough to fit in the palm of your hand, these pumps transfer water, detergents, and chemicals. They have a chemical-resistant polypropylene housing. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps can run dry.
Pumps with fluoroelastomer diaphragm are also suitable for use with fuel and oil.

Max. Flow Rate, gpm | Overall | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Max. Flow Rate, gpm | @ 1 ft. of Head | @ 3 ft. of Head | @ 4 ft. of Head | @ 5 ft. of Head | Max. Viscosity, cP | Air Consumption, cfm | Air Connection ID | Intake Tube Connection | Discharge Tube connection | Diaphragm Material | Lg. | Wd. | Ht. | Each | |
15 ft. of Head—100 psi Max. Discharge Pressure | |||||||||||||||
| 5 | 5 | 3.7 | 2.9 | 1.8 | 700 | 1.5 | 1/4" Male | 3/8" Male | 3/8" Male | Santoprene Rubber | 4 9/16" | 1 13/16" | 5 13/16" | 0000000 | 0000000 |
| 5 | 5 | 3.7 | 2.9 | 1.8 | 700 | 1.75 | 1/4" Male | 1/2" Male | 1/2" Male | Santoprene Rubber | 4 9/16" | 1 13/16" | 5 13/16" | 0000000 | 000000 |
| 5 | 5 | 3.7 | 2.9 | 1.8 | 700 | 1.75 | 1/4" Male | 1/2" Male | 1/2" Male | Fluoroelastomer Rubber | 4 9/16" | 1 13/16" | 5 13/16" | 0000000 | 000000 |
Submersible Pumps for Water





Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Hardwire pumps must be wired to a plug (not included).

Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
| A | Plug | 2.8 | 1.7 | __ | 7 | 35° to 120° | 1/125 hp | 0.6 | Screened | 1/4 | NPT | Male | 6 | 3 5/8" | 2 7/8" | 3 1/2" | 0000000 | 0000000 |
| A | Plug | 5 | 4 | 2.2 | 12.2 | 35° to 120° | 1/40 hp | 0.8 | Screened | 1/4 | NPT | Male | 6 | 4 1/4" | 2 7/8" | 4 7/8" | 0000000 | 000000 |

Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
115V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||||||
| B | Plug | 3.5 | 1.7 | __ | 7 | 35° to 85° | 1/30 hp | 0.5 | Screened | 1/4 | NPT | Male | 16 | 2 3/4" | 3 1/2" | 4 5/8" | 0000000 | 000000 |
| B | Plug | 5.7 | 4.7 | 2 | 12 | 35° to 85° | 1/15 hp | 0.8 | Screened | 1/4 | NPT | Male | 16 | 4 7/8" | 2 3/4" | 4" | 0000000 | 000000 |
| B | Plug | 9.2 | 7 | 3.5 | 13 | 35° to 85° | 1/10 hp | 1.2 | Screened | 1/2 | NPT | Male | 16 | 3" | 4" | 5" | 0000000 | 000000 |

Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
| C | Plug | 3.5 | 2.5 | __ | 10.2 | 35° to 120° | 1/150 hp | 1.1 | Screened | 1/4 | NPT | Male | 6 | 4 5/8" | 4 1/8" | 4 1/8" | 0000000 | 0000000 |
| C | Plug | 5.4 | 4.5 | 2.2 | 12.3 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 6 | 4 5/8" | 5" | 5" | 0000000 | 000000 |
| C | Plug | 5.4 | 4.5 | 2.2 | 12.3 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 18 | 4 5/8" | 5" | 5" | 0000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
| C | Hardwire | 5.4 | 4.5 | 2.2 | 12.3 | 35° to 120° | 1/40 hp | 0.7 | Screened | 1/4 | NPT | Male | 12 | 4 5/8" | 5" | 5" | 0000000 | 000000 |

Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
| D | Plug | 7.9 | 6.6 | 3.4 | 13.4 | 35° to 120° | 1/28 hp | 1.4 | Screened | 3/8 | NPT | Male | 6 | 4" | 4" | 4 5/8" | 0000000 | 0000000 |

Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Electrical Connection Type | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Cord Length, ft. | Ht. | Wd. | Dp. | Each | ||
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
| E | Plug | 20 | 12 | 4 | 15 | 35° to 85° | 1/15 hp | 1 | Screened | 3/4 | NPT | Male | 15 | 5 1/4" | 3 3/4" | 6 3/8" | 00000000 | 0000000 |
Submersible/Open-Air Pumps for Water

These pumps can be submerged or connected remotely to a pipe in your line. Use them to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Max. Flow Rate, gpm | Intake | Discharge | Overall | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| @ 1 Ft. of Head | @ 5 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Plug | ||||||||||||||||
| 2.8 | 1.7 | 7 | 35° to 120° | 1/125 hp | 0.6 | 1/4 × 1/2 | NPT × NPT | Female × Male | 1/4 | NPT | Male | 3 3/8" | 3 3/4" | 2 3/4" | 0000000 | 0000000 |
Impact-Resistant Submersible/Open-Air Pumps for Water


Protected from impact by a durable epoxy-coated aluminum housing, these pumps can be submerged or connected remotely to a pipe in your line. Use to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Hardwire pumps must be wired to a plug (not included).
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Features | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug | |||||||||||||||||||
| A | 3.4 | 2 | __ | 7.4 | 35° to 120° | 1/150 hp | 1.1 | 1/4 × 1/2 | NPT × NPT | Female × Male | 1/4 | NPT | Male | 4 1/8" | 4 1/8" | 4 5/8" | __ | 0000000 | 0000000 |
| B | 5 | 3.4 | 1.2 | 11.8 | 35° to 120° | 1/40 hp | 1.7 | 3/8 | NPT | Female | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | Removable Intake Screen | 000000 | 000000 |
| B | 8.3 | 5.6 | 3.5 | 17.3 | 35° to 120° | 1/15 hp | 3.2 | 1/2 | NPT | Female | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | Removable Intake Screen | 000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire | |||||||||||||||||||
| B | 5 | 3.4 | 1.2 | 11.8 | 35° to 120° | 1/40 hp | 0.7 | 3/8 | NPT | Female | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | Removable Intake Screen | 0000000 | 000000 |
| B | 10 | 8.6 | 6.9 | 21 | 35° to 120° | 1/15 hp | 1.4 | 1/2 | NPT | Female | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | Removable Intake Screen | 0000000 | 000000 |
Impact-Resistant Submersible Pumps for Water


The durable epoxy-coated aluminum housing handles hard knocks in rough waters. Submerge these pumps to circulate water in small tanks, cooling baths, fountains, and other low-flow applications. Plug in to activate. Do not run dry. Not for use with salt water or flammable liquids.
Hardwire pumps must be wired to a plug (not included).
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Plug | ||||||||||||||||
| A | 2.8 | 1.7 | __ | 7 | 35° to 120° | 1/200 hp | 1.1 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 1/8" | 4 1/8" | 0000000 | 0000000 |
| B | 5 | 3.4 | 1.2 | 11.8 | 35° to 120° | 1/40 hp | 1.7 | Screened | 1/4 | NPT | Male | 4 3/4" | 3 1/2" | 5 1/2" | 000000 | 000000 |
| B | 13.5 | 12.4 | 10.2 | 24.5 | 35° to 120° | 1/12 hp | 3.5 | Screened | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | 000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
| A | 3.4 | 2 | __ | 7.4 | 35° to 120° | 1/150 hp | 0.4 | Screened | 1/4 | NPT | Male | 4 1/4" | 4 1/8" | 4 1/8" | 0000000 | 000000 |
| B | 13.5 | 12.4 | 10.2 | 24.5 | 35° to 120° | 1/12 hp | 1.6 | Screened | 1/2 | NPT | Male | 5 1/2" | 4 1/2" | 7" | 0000000 | 000000 |
Fixed-Flow-Rate Metering Pumps for Chemicals
Also known as peristaltic pumps and tubing pumps, these maintain a fixed flow rate. Pumps are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Mount them up to 25 feet above your liquid source. All can run dry. Do not use with solids.
Pumps with Tygon 2375 lining resist harsh substances such as isopropyl alcohol and sodium chloride.
Pumps with Viton® fluoroelastomer tubing withstand oil such as gasoline and hydraulic oil.

Overall | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Flow Rate, gal./day (For Tube ID) | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Lg. | Wd. | Ht. | Includes | Each | |
115V AC, Single Phase—Plug | |||||||||||
Polypropylene Plastic and Tygon Wetted Parts Material | |||||||||||
| 0.07 (1/16") 0.25 (1/8") | 30 | 800 | 32° to 122° | Subfractional | 0.03 | 5 1/2" | 3 1/4" | 3 3/4" | 4 1/2" Lg. of 1/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 4 1/2" Lg. of 1/8" ID Tygon Tubing with Tygon 2375 Lining (Shore A60) | 000000000 | 0000000 |
| 0.34 (1/16") 1.25 (1/8") | 30 | 800 | 32° to 122° | Subfractional | 0.03 | 5 1/2" | 3 1/4" | 3 3/4" | 4 1/2" Lg. of 1/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 4 1/2" Lg. of 1/8" ID Tygon Tubing with Tygon 2375 Lining (Shore A60) | 000000000 | 000000 |
| 0.87 (1/16") 3.53 (1/8") 6.84 (3/16") | 30 | 800 | 32° to 122° | Subfractional | 0.03 | 5 1/2" | 3 1/4" | 3 3/4" | 6" Lg. of 1/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 1/8" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 3/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60) | 000000000 | 000000 |
| 1.75 (1/16") 7.07 1/8") 13.68 (3/16") | 30 | 800 | 32° to 122° | Subfractional | 0.03 | 5 1/2" | 3 1/4" | 3 3/4" | 6" Lg. of 1/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 1/8" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 3/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60) | 000000000 | 000000 |
| 22.80 (3/16") 38.00 (1/4") | 15 | 500 | 32° to 122° | Subfractional | 0.52 | 5" | 5" | 7" | 6" Lg. of 3/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 1/4" ID Tygon Tubing with Tygon 2375 Lining (Shore A60) | 000000000 | 000000 |
| 45.6 (3/16") 76.00 (1/4") | 15 | 200 | 32° to 122° | Subfractional | 0.65 | 5" | 5" | 7" | 6" Lg. of 3/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 1/4" ID Tygon Tubing with Tygon 2375 Lining (Shore A60) | 000000000 | 000000 |
| 228.00 (3/16") 380.00 (1/4") | 15 | 50 | 32° to 122° | Subfractional | 1.74 | 5" | 5" | 7" | 6" Lg. of 3/16" ID Tygon Tubing with Tygon 2375 Lining (Shore A60), 6" Lg. of 1/4" ID Tygon Tubing with Tygon 2375 Lining (Shore A60) | 000000000 | 000000 |
PVDF Plastic and Viton® Fluoroelastomer Rubber Wetted Parts Material | |||||||||||
| 0.02 (1/32") 0.07 (1/16") 0.25 (1/8") | 30 | 800 | 32° to 122° | Subfractional | 0.03 | 5 1/2" | 3 1/4" | 3 3/4" | 4 1/2" Lg. of 1/32" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60) | 000000000 | 000000 |
| 0.11 (1/32") 0.34 (1/16") 1.25 (1/8") | 30 | 800 | 32° to 122° | Subfractional | 0.03 | 5 1/2" | 3 1/4" | 3 3/4" | 4 1/2" Lg. of 1/32" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60) | 000000000 | 000000 |
| 0.87 (1/16") 3.53 (1/8") 6.84 (3/16") | 30 | 800 | 32° to 122° | Subfractional | 0.03 | 5 1/2" | 3 1/4" | 3 3/4" | 6" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60) | 000000000 | 000000 |
| 1.75 (1/16") 7.07 1/8") 13.68 (3/16") | 30 | 800 | 32° to 122° | Subfractional | 0.03 | 5 1/2" | 3 1/4" | 3 3/4" | 6" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60) | 000000000 | 000000 |
| 22.80 (3/16") 38.00 (1/4") | 15 | 500 | 32° to 122° | Subfractional | 0.52 | 5" | 5" | 7" | 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60) | 000000000 | 000000 |
| 45.6 (3/16") 76.00 (1/4") | 15 | 200 | 32° to 122° | Subfractional | 0.65 | 5" | 5" | 7" | 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60) | 000000000 | 000000 |
| 228.00 (3/16") 380.00 (1/4") | 15 | 50 | 32° to 122° | Subfractional | 1.74 | 5" | 5" | 7" | 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60) | 000000000 | 000000 |
120V AC, Single Phase—Plug | |||||||||||
ABS Plastic and Tygon Wetted Parts Material | |||||||||||
| 0.02 (1/32") 0.07 (1/16") 0.25 (1/8") | 30 | 300 | 32° to 122° | Subfractional | 0.03 | 5 1/2" | 3 1/4" | 3 3/4" | 4 1/2" Lg. of 1/32" ID Tygon Tubing (Shore A60), 4 1/2" Lg. of 1/16" ID Tygon Tubing (Shore A60), 4 1/2" Lg. of 1/8" ID Tygon Tubing (Shore A60) | 000000000 | 000000 |
| 0.11 (1/32") 0.34 (1/16") 2.35 (1/8") | 30 | 300 | 32° to 122° | Subfractional | 0.03 | 5 1/2" | 3 1/4" | 3 3/4" | 4 1/2" Lg. of 1/32" ID Tygon Tubing (Shore A60), 4 1/2" Lg. of 1/16" ID Tygon Tubing (Shore A60), 4 1/2" Lg. of 1/8" ID Tygon Tubing (Shore A60) | 000000000 | 000000 |
| 0.87 (1/32") 3.53 (1/16") 6.84 (3/16") | 30 | 500 | 32° to 122° | Subfractional | 0.03 | 5 1/2" | 3 1/4" | 3 3/4" | 5 1/2" Lg. of 1/16" ID Tygon Tubing (Shore A60), 5 1/2" Lg. of 1/8" ID Tygon Tubing (Shore A60), 6" Lg. of 3/16" ID Tygon Tubing (Shore A60) | 000000000 | 000000 |
| 22.80 (3/16") 38.00 (1/4") | 15 | 1,000 | 32° to 122° | Subfractional | 0.52 | 7" | 5" | 5" | 7" Lg. of 3/16" ID Tygon Tubing (Shore A60), 7" Lg. of 1/4" ID Tygon Tubing (Shore A60) | 000000000 | 000000 |
Norprene and Santoprene Rubber Wetted Parts Material | |||||||||||
| 5.36 (1/8") 11.34 (3/16") 18.560 (1/4") | 25 | 10,000 | 32° to 104° | Subfractional | 0.37 | 6" | 5" | 5 5/8" | 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60), 9" Lg. of 1/4" ID Norprene Tubing (Shore A60) | 000000000 | 000000 |
| 24.88 (1/8") 52.34 (3/16") 85.820 (1/4") | 25 | 10,000 | 32° to 104° | Subfractional | 1.2 | 6" | 5" | 5 5/8" | 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60), 9" Lg. of 1/4" ID Norprene Tubing (Shore A60) | 000000000 | 000000 |
| 39.41 (1/8") 82.93 (3/16") 135.960 (1/4") | 25 | 10,000 | 32° to 104° | Subfractional | 1.9 | 6" | 5" | 5 5/8" | 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60), 9" Lg. of 1/4" ID Norprene Tubing (Shore A60) | 00000000 | 000000 |
| 71.25 (1/8") 149.84 (3/16") 245.670 (1/4") | 25 | 10,000 | 32° to 104° | Subfractional | 2.2 | 6" | 5" | 5 5/8" | 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60), 9" Lg. of 1/4" ID Norprene Tubing (Shore A60) | 000000000 | 000000 |
| 114.96 (1/8") 241.86 (3/16") 396.460 (1/4") | 25 | 10,000 | 32° to 104° | Subfractional | 3.3 | 6" | 5" | 5 5/8" | 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60), 9" Lg. of 1/4" ID Norprene Tubing (Shore A60) | 00000000 | 000000 |
| For Flow Rate, gal./day | Each | |
For Polypropylene Plastic and Tygon Wetted Parts Material | ||
|---|---|---|
| 0.06-0.34 | 000000000 | 000000 |
| 0.24-1.25 | 000000000 | 00000 |
| 0.87-1.75 | 000000000 | 00000 |
| 3.53-7.07 | 000000000 | 00000 |
| 6.84-13.68 | 000000000 | 00000 |
| 22.8-228 | 000000000 | 00000 |
| 38-380 | 000000000 | 00000 |
For PVDF Plastic and Viton® Fluoroelastomer Wetted Parts Material | ||
| 0.02-0.11 | 000000000 | 00000 |
| 0.06-0.34 | 000000000 | 00000 |
| 0.24-1.25 | 000000000 | 00000 |
| 0.87-1.75 | 000000000 | 00000 |
| 3.53-7.07 | 000000000 | 00000 |
| 6.84-13.68 | 000000000 | 00000 |
| 22.8-228 | 000000000 | 00000 |
| 38-380 | 000000000 | 00000 |
For ABS Plastic and Tygon Wetted Parts Material | ||
| 0.02-0.11 | 000000000 | 00000 |
| 0.06-0.34 | 000000000 | 00000 |
| 0.24-1.25 | 000000000 | 00000 |
| 0.87 | 000000000 | 00000 |
| 3.53 | 000000000 | 00000 |
| 6.84 | 000000000 | 00000 |
| 22.8 | 000000000 | 00000 |
| 38 | 000000000 | 00000 |
For Norprene and Santoprene Wetted Parts Material | ||
| 1-376 | 00000000 | 00000 |
Panel-Mount Fixed-Flow-Rate Metering Pumps for Chemicals

Install these pumps in a panel cutout. Often used in food and beverage, pharmaceutical, and lab applications, they dispense small amounts of liquid at a set rate. Pumps can be wired to a switch for manual operation, or a PLC for automated equipment. The removable pump head includes an intake tube that quickly connects to your line with barbed fittings (not included). To change lines, disconnect tubing and twist and pull the head off the motor. Then twist on a replacement head (sold separately). Pumps come in three colors for easy identification or to match your existing equipment. All are self-priming and create suction to draw liquid upward. Mount pumps up to 28 ft. above your liquid source. They can run dry.
Overall | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Flow Rate, ml/min. | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Wd. | Ht. | Dp. | Each | |
Blue | ||||||||||
24V DC | ||||||||||
Hardwire | ||||||||||
| 55 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 0000000 |
| 160 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
Clear | ||||||||||
24V DC | ||||||||||
Hardwire | ||||||||||
| 55 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
| 160 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
Green | ||||||||||
24V DC | ||||||||||
Hardwire | ||||||||||
| 55 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
| 160 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
Miniature Metering Pumps for Chemicals

With a footprint that's only a few inches in any direction, these pumps fit into compact systems to dispense small amounts of acids, cleaning fluids, and other chemicals. They're often used in sterilization, photochemical, and water treatment systems. Choose from pumps with either a 4-20mA or 1-5V DC input signal that controls the flow rate.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
External | Overall | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Flow Rate, gal./day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Current, A | Signal | Voltage | For Intake Tube ID | For Discharge Tube ID | For Tube OD | Lg. | Wd. | Ht. | Each | |
12V DC—With Thermal Overload Protection | ||||||||||||||
Hardwire | ||||||||||||||
| 14 | 29 | 6 | 30° to 100° | 1.5 | __ | 1-5V DC | 1/8" | 1/8" | 1/4" | 4" | 2 1/2" | 3 5/8" | 000000 | 0000000 |
| 14 | 29 | 6 | 30° to 100° | 1.5 | 4-20mA | __ | 1/8" | 1/8" | 1/4" | 4" | 2 1/2" | 3 5/8" | 000000 | 000000 |
24V DC—With Thermal Overload Protection | ||||||||||||||
Hardwire | ||||||||||||||
| 14 | 29 | 6 | 30° to 100° | 1 | __ | 1-5V DC | 1/8" | 1/8" | 1/4" | 4" | 2 1/2" | 3 5/8" | 000000 | 000000 |
| 14 | 29 | 6 | 30° to 100° | 1 | 4-20mA | __ | 1/8" | 1/8" | 1/4" | 4" | 2 1/2" | 3 5/8" | 000000 | 000000 |
Condensate Pumps with Tank

Equipped with a built-in container for condensate, these pumps work alongside your system to remove condensate from air conditioners, refrigerators, dehumidifiers, and other equipment. They are not submersible. A safety switch turns off your equipment in case of pump failure. Pumps turn on and off automatically.
Hardwire pumps must be wired to a power source.
Style A pumps have a two-piece body so you can install them up to 3 ft. away from the condensate reservoir.

Max. Flow Rate, gpm | Level | Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Style | Electrical Connection Type | Tank Capacity, oz. | @ 1 Ft. of Head | @ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Max. Pressure, psi | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Discharge Pipe Size | Ht. | Wd. | Dp. | Each | |
120V AC/240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
| A | Hardwire | 0.7 | 0.04 | 0.03 | 0.03 | 33 | 26 | 9/16" | 0.38" | 35° to 140° | Not Rated | 0.1/0.2 | 1/4 NPT Male | 2 3/8" | 1 7/8" | 4 1/8" | 0000000 | 0000000 |
Miniature Water-Removal Pumps with Hose
Complete with a suction strainer and 6 feet of garden hose, this little pump comes ready to clean up small open spaces. It activates when you plug it in. Use with debris-free water.
Maintenance kits (sold separately) include an impeller, an O-ring, and a seal.
Note: The pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| @ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Thread Size | Thread Type | Gender | Hose Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug with 6 ft. Cord | |||||||||||||||||||
| 5.5 | 5 | 4.5 | 4 | 43 | 1/8" | 35° to 75° | 1/12 hp | 2 | 3/4 | GHT | Male | 3/4 | GHT | Male | 6" | 5" | 7" | 0000000 | 0000000 |
| Maintenance Kit | 0000000 | Each | 000000 |
Water Removal Pumps with Hose

Use this pump to remove water with small solids up to 1/4" in diameter. It activates when plugged in; add a plug-in switch to control when the pump activates. Install in water that's at least 2" deep. Pump includes a 25-ft. hose with cam-and-groove fittings for quick, secure connections and a storage crate with built-in filtration to protect the pump from debris.
Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| @ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Flow Rate | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Connection Coupling Size | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||
Plug with 15" Cord | |||||||||||||||||
| 41 | 32 | 23 | 11 | 41 gpm | 25 | 1/4" | 7/16" | 35° to 100° | 4/10 hp | 3 | 1 1/4 | Male | 12 3/4" | 11 13/16" | 15 3/4" | 0000000 | 0000000 |
Drum Pumps for Food and Beverage
Use these pumps in food and beverage applications.

























