Wall-Mount Motion-Sensing Light Controls


Light controls fit standard wall plates. Also known as occupancy sensors, they turn lights on when movement is detected and off when an area is unoccupied. The infrared sensors detect changes in heat sources and require a direct view of the occupants. All have a time delay to turn lights off after a set time.
Ivory | White | |||||||
---|---|---|---|---|---|---|---|---|
Coverage, sq. ft. | No. of Circuits Controlled | Input Voltage | Wattage | Wire Connection Type | Each | Each | ||
180 | 2 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | Wire Leads | 0000000 | 0000000 | 0000000 | 0000000 |
300 | 1 | 120V AC 240V AC 277V AC | 1,200 W @ 277 V AC 1,200 W @ 240 V AC 1,000 W @ 120 V AC | Wire Leads | 0000000 | 00000 | 0000000 | 00000 |
Multi-Way Wall-Mount Motion-Sensing Light Controls

Control lights on a single circuit from more than one motion-sensing switch. Also known as occupancy sensors, these controls turn lights on when movement is detected and off when an area is unoccupied. The infrared sensors detect changes in heat sources and require a direct view of the occupants. Use up to four controls on the same circuit to detect motion in large rooms. All have a time delay to turn lights off after a set time.
Coverage, sq. ft. | No. of Circuits Controlled | Max. No. per Circuit | Input Voltage | Wattage | For Outlet Box Type | Max. Mounting Ht., ft. | Color | Housing Material | Wire Connection Type | Specifications Met | Each | |
1,050 | 1 | 4 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 1 Device (1 Gang) | 4 | White | Plastic | Wire Leads | UL Listed, C-UL Listed | 0000000 | 0000000 |
Fixture-Mount Motion-Sensing Light Controls for Wet Locations

Rated IP65, these controls are protected from washdowns. Also known as occupancy sensors, they turn lights on when movement is detected and off when an area is unoccupied. The infrared sensors detect changes in heat sources and require a direct view of the occupants. All have a time delay to turn lights off after a set time.
Conduit | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Coverage, sq. ft. | No. of Circuits Controlled | Input Voltage | Wattage | Max. Mounting Ht., ft. | Color | Housing Material | Connection Gender | Trade Size | Thread Type | Ht. | Dia. | Wire Connection Type | Specifications Met | Each | |
1,000 | 1 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 40 | White | Plastic | Male | 1/2 | NPT | 1 15/16" | 3 11/16" | Wire Leads | UL Listed, C-UL Listed | 0000000 | 0000000 |
1,200 | 1 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 20 | White | Plastic | Male | 1/2 | NPT | 2 1/4" | 3 11/16" | Wire Leads | UL Listed, C-UL Listed | 0000000 | 000000 |
Fixture-Mount Motion-Sensing Light Controls

Mount these controls directly to a light fixture. Also known as occupancy sensors, they turn lights on when movement is detected and off when an area is unoccupied. The infrared sensors detect changes in heat sources and require a direct view of the occupants. All have a time delay to turn lights off after a set time.
Mounting extensions (sold separately) improve the position of light controls.
Conduit | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Coverage, sq. ft. | No. of Circuits Controlled | Input Voltage | Wattage | Max. Mounting Ht., ft. | Color | Housing Material | Connection Gender | Trade Size | Thread Type | Ht. | Wd. | Dp. | Wire Connection Type | Specifications Met | Each | |
155 | 1 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 45 | White | Plastic | Male | 1/2 | NPT | 2 3/16" | 4 3/32" | 4 5/8" | Wire Leads | UL Listed, C-UL Listed | 0000000 | 0000000 |
155 | 2 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 45 | White | Plastic | Male | 1/2 | NPT | 2 3/16" | 4 3/32" | 4 5/8" | Wire Leads | UL Listed, C-UL Listed | 0000000 | 000000 |
Mounting Extension | 0000000 | Each | 000000 |
Ceiling-Mount Motion-Sensing Light Controls

Also known as occupancy sensors, these controls turn lights on when movement is detected and off when an area is unoccupied. All have a time delay to turn lights off after a set time.
Infrared sensors detect moving heat sources and require a direct view of the occupants.
Infrared/ultrasonic sensors minimize false activation by detecting changes in heat sources and motion. They can be set so that only one or both detection methods are required to activate and hold lights on.
Ultrasonic sensors detect movement and don’t require a direct view of the occupants.
Motion Sensor Type | Coverage, sq. ft. | No. of Circuits Controlled | Input Voltage | Wattage | For Outlet Box Type | Color | Ht. | Dia. | Wire Connection Type | Specifications Met | Each | |
Infrared | 1,500 | 1 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 2 Device (2 Gang) | White | 1 7/8" | 4" | Wire Leads | UL Listed, C-UL Listed | 0000000 | 0000000 |
Infrared/Ultrasonic | 1,000 | 1 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 2 Device (2 Gang) | White | 1 1/2" | 4 1/2" | Screw Terminals | UL Listed, C-UL Listed | 0000000 | 000000 |
Ultrasonic | 2,000 | 1 | 120V AC 277V AC | 800 W @ 120 V AC 1,200 W @ 277 V AC | 2 Device (2 Gang) | White | 1 1/2" | 4 1/2" | Screw Terminals | UL Listed, C-UL Listed | 0000000 | 000000 |
Guard | 0000000 | Each | 000000 |
Wall/Ceiling-Mount Motion-Sensing Light Controls

Also known as occupancy sensors, these controls turn lights on when movement is detected and off when an area is unoccupied. The infrared/ultrasonic sensors minimize false activation by detecting heat and motion. They can be set so that only one or both detection methods are required to activate and hold lights on. All have a time delay to turn lights off after a set time. The mounting bracket swivels 90° so that the control can be mounted on a wall or ceiling.
Power controllers (sold separately) are required to switch a 120- or 277-volt AC lighting circuit. They have a relay that switches a maximum 20 amp load.
Coverage, sq. ft. | No. of Circuits Controlled | Input Voltage | Max. Mounting Ht., ft. | Mounting Hardware Included | Swivel Angle | Color | Housing Material | Ht. | Wd. | Dp. | Wire Connection Type | Specifications Met | Each | |
2,000 | 1 | 24V DC | 10 | Yes | 90° | White | Plastic | 4 3/8" | 3 3/8" | 2" | Wire Leads | UL Listed, C-UL Listed | 0000000 | 0000000 |
Power Controller | 0000000 | Each | 000000 |
Light Beam Finger-Touch Switches

An infrared light beam senses the lightest finger contact to switch a circuit on or off. The included guard prevents accidental activation. An indicator lights up to confirm that switches are actuated. They’re rated NEMA 4X, 13, and IP66 for protection from corrosion, washdowns, and oil/coolant spraying.
Switches with a 5-pole mini plug can quickly be changed out.
For technical drawings and 3-D models, click on a part number.
Wire Leads | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switch Action | Industry Designation | Actuator Color | Switching Current @ Voltage | Current Output, mA | Input Voltage | Dp. Behind Panel | No. of | Ga. | Features | Each | |
Plastic Actuator with Wire Leads | |||||||||||||
For 30 mm Panel Cutout Dia. | |||||||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | SPDT | Black | 7 A @ 120 V AC | __ | 120V AC | 3/4" | 5 | 22 | Guard Output Indicator Power Indicator | 00000000 | 0000000 |
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | SPDT | Black | 7 A @ 120 V AC | __ | 20V AC-30V AC/20V DC-30V DC | 3/4" | 5 | 22 | Guard Output Indicator Power Indicator | 00000000 | 000000 |
Plastic Actuator with Wire Leads and NPN Output | |||||||||||||
For 30 mm Panel Cutout Dia. | |||||||||||||
__ | __ | Springs Back (Momentary) | __ | Black | __ | 150 | 10V DC-30V DC | 3/4" | 4 | 22 | Guard Output Indicator Power Indicator | 00000000 | 000000 |
Plastic Actuator with 5-Pole Mini Plug | |||||||||||||
For 30 mm Panel Cutout Dia. | |||||||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | SPDT | Black | 7 A @ 120 V AC | __ | 120V AC | 1 3/8" | __ | __ | Guard Output Indicator Power Indicator | 00000000 | 000000 |