    12 Products

    Capacitive Noncontact Level Sensor Switches for Chemicals

    Image of Product. Front orientation. Level Sensor Switches. Capacitive Noncontact Level Sensor Switches for Chemicals.
    This switch mounts to the outside of your tank and detects chemical level through plastic tank walls by measuring the capacitance between the switch and tank contents; it cannot be used with metal tanks. Mount switch horizontally or vertically with the included mounting bracket.
    Temp. Range,
    ° F
    Switch Starting
    Position
    Switch
    Designation
    Current @ Voltage
    Dia.
    Lg.
    Electrical
    Connection
    Includes
    Certification
    Each
    20V AC to 240V AC Input Voltage
    -10 to 1751 Off, 1 On
    SPST-NC
    SPST-NO
    0.25 amp @ 240V AC1 3/16"3"Wire LeadsMounting BracketUL Listed, CSA Certified
    00000000000000
     

    Noncontact Level Sensor Switches for Conductive Liquids

    Measure the level of conductive liquids without drilling a hole in your tank—these switches mount to the outside of the tank and track the capacitance between them and the tank’s contents. Use them on nonconductive plastic or glass wall tanks; they’re not compatible with metal tanks. They automatically adapt to your tank’s wall thickness, making them ready to use. These switches only respond when the liquid reaches the desired level, so foam and residue on the top of the liquid won’t trigger them early. For even more challenging setups, such as those with thick, sticky fluids, or if your tank has walls as thick as 10 mm, you can teach these switches to avoid false detections. All have LED indicators to show their power and output status.
    Made of plastic, their body is chemical resistant and NEMA and IP rated, so it keeps out dust and dirt, as well as drips of oil and jets of hot water. UL listed, C-UL listed, and CE marked, they meet U.S., Canadian, and European Union safety standards.
    Mount these switches directly on your sight glass using their adhesive back or use the included mounting bracket if you’ll need to remove them frequently. They also include foam pads for mounting them using straps around the outside of your tank.
    Level Sensor Switches with Nano M8 4-Pin Connection
    Image of Product. With Nano M8 4-pin Connection. Front orientation. Level Sensor Switches. Noncontact Level Sensor Switches for Conductive Liquids, Level Sensor Switches with Nano M8 4-Pin Connection.
    Image of Specification. Nano M8 4-pin. Front orientation. Nano M8 Connection. Noncontact Level Sensor Switches for Conductive Liquids, 4 Pins.

    With Nano M8 4-pin

    Connection

    Nano

    M8

    4-pin

    Switches with an Nano M8 4-Pin connection have a standard plug that’s easy to connect.
    PNP Signal Output—PNP switches communicate with your system by sending a positive signal.
    Signal
    Output
    Wd.
    Ht.
    Thk.
    Temp. Range,
    ° F
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Enclosure Rating
    Each
    10V DC to 30V DC Input Voltage
     
    Polybutylene/Polycarbonate Body
    PNP5/8"1 5/16"5/16"-10 to 1751 Off
    SPST-NO
    0.1 amp @ 30V DCNEMA 4X, NEMA 12, IP68, IP69K, IP66
    00000000000000
    PNP5/8"1 5/16"5/16"-10 to 1751 On
    SPST-NC
    0.1 amp @ 30V DCNEMA 4X, NEMA 12, IP68, IP69K, IP66
    0000000000000
     
    Level Sensor Switches with Wire Lead Connection
    Image of Product. With Wire Lead Connection. Front orientation. Level Sensor Switches. Noncontact Level Sensor Switches for Conductive Liquids, Level Sensor Switches with Wire Lead Connection.

    With Wire Lead Connection

    Switches with wire leads need to be hardwired, so use them in applications where you won’t move them often.
    PNP Signal Output—PNP switches communicate with your system by sending a positive signal.
    NPN Signal Output—NPN switches send a negative signal to communicate with your system.
    Signal
    Output
    Wd.
    Ht.
    Thk.
    Temp. Range,
    ° F
    Switch Starting
    Position
    Switch
    Designation
    Current @
    Voltage
    Wire Lead
    Lg., ft.
    Enclosure Rating
    Each
    10V DC to 30V DC Input Voltage
     
    Polybutylene/Polycarbonate Body
    PNP5/8"1 5/16"5/16"-10 to 1751 Off
    SPST-NO
    0.1 amp @ 30V DC6NEMA 4X, NEMA 12, IP68, IP69K, IP66
    00000000000000
    PNP5/8"1 5/16"5/16"-10 to 1751 On
    SPST-NC
    0.1 amp @ 30V DC6NEMA 4X, NEMA 12, IP68, IP69K, IP66
    0000000000000
    NPN5/8"1 5/16"5/16"-10 to 1751 Off
    SPST-NO
    0.1 amp @ 30V DC6NEMA 4X, NEMA 12, IP68, IP69K, IP66
    0000000000000
    NPN5/8"1 5/16"5/16"-10 to 1751 On
    SPST-NC
    0.1 amp @ 30V DC6NEMA 4X, NEMA 12, IP68, IP69K, IP66
    0000000000000
     

    Infrared Noncontact Level Sensor Switches for Chemicals

    Image of Product. Front orientation. Contains Annotated. Level Sensor Switches. Infrared Noncontact Level Sensor Switches for Chemicals.
    Detect chemical level with infrared light to avoid false switch activation caused by vibration in your tank. Also known as optical switches, these sense the level by reflecting light into a receiver that sends an output current to activate an alarm or control circuit. They are sensitive to light and should be shielded or used in enclosed tanks. Mount them horizontally or vertically.
    SPST-NC—SPST-NC switches activate when the tip is exposed to air and light reflects into the receiver.
    SPST-NO—SPST-NO switches activate when the tip is submerged in liquid and light stops reflecting into the receiver.
    Pipe
    Size
    Thread
    Type
    Gender
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Output Current,
    mA
    Overall
    Lg.
    Hex
    Size
    Electrical
    Connection
    Each
    10V DC to 40V DC Input Voltage
     
    Polysulfone Body
    3/8
    BSPP
    Male145 psi @ 70° F0 to 1751 3/4"1 Off
    SPST-NO
    2003"1 1/16"Wire Leads00000000000000
    3/8
    BSPP
    Male145 psi @ 70° F0 to 1751 3/4"1 On
    SPST-NC
    2003"1 1/16"Wire Leads0000000000000
     

    Noncontact Level Sensor Switches for Water

    Image of Product. Front orientation. Contains Annotated. Level Sensor Switches. Noncontact Level Sensor Switches for Water.
    Detect water level with infrared light to avoid false switch activation caused by vibration in your tank. Also known as optical switches, these sense the level by reflecting light into a receiver that sends an output current to activate an alarm or control circuit. They are sensitive to light and should be shielded or used in enclosed tanks. Mount them horizontally or vertically.
    SPST-NC—SPST-NC switches activate when the tip is exposed to air and light reflects into the receiver.
    SPST-NO—SPST-NO switches activate when the tip is submerged in liquid and light stops reflecting into the receiver.
    Pipe
    Size
    Thread
    Type
    Gender
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Insertion
    Dp.
    Switch Starting
    Position
    Switch
    Designation
    Output Current,
    mA
    Overall
    Lg.
    Hex
    Size
    Electrical
    Connection
    Each
    10V DC to 28V DC Input Voltage
     
    Polysulfone Body
    1/4
    NPT
    Male150 psi @ 70° F0 to 1751/4"1 Off
    SPST-NO
    402 3/16"5/8"Wire Leads000000000000000
    1/4
    NPT
    Male150 psi @ 70° F0 to 1751/4"1 On
    SPST-NC
    402 3/16"5/8"Wire Leads00000000000000
     

    Ultrasonic Noncontact Level Sensor Switches for Chemicals

    Image of Product. Front orientation. Level Sensor Switches. Ultrasonic Noncontact Level Sensor Switches for Chemicals.
    Use high-frequency sound waves to detect chemical level. This switch has three relays that can be programmed for multiple set points. Use it to activate several alarms or to automate tank filling and emptying. It’s rated NEMA 4X for protection from corrosion and washdowns.
    Pipe
    Conduit
    Size
    Thread
    Type
    Gender
    Sensing Distance,
    ft.
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Switch Starting
    Position
    Switch
    Designation
    Current @ Voltage
    Lg.
    Wd.
    Electrical
    Connection
    Enclosure
    Rating
    Trade
    Size
    Thread
    Type
    Gender
    Each
    95V AC to 250V AC Input Voltage
     
    Polycarbonate Body
    1
    NPT
    Male0.33 to 9.830 psi @ 70° F-5 to 1401 Off or 1 On
    SPDT
    0.17 amp @ 120V AC3 15/16"5 3/16"Screw TerminalIP65, NEMA 4X
    1/2
    NPT
    Female00000000000000
     
    back to top