Component Component |
---|
![]() |
Regulator |
![]() |
Filter/Regulator |
![]() |
Manifold Regulator |
![]() |
Filter/Regulator/Lubricator |
Maximum Flow Rate Maximum Flow Rate |
---|
Outlet Type Outlet Type |
---|
|
More
Adjust and maintain the pressure of your compressed air. All regulators are relieving style, so they exhaust when the downstream pressure exceeds the set pressure. Install in your air line after filters.
Mounting brackets (sold separately) allow you to attach the regulator to a wall or equipment.
Joiner clamps (sold separately) connect the regulator to another Norgren modular component with the same series number. They come with mounting brackets.
End block sets (sold separately) allow you to swap out filter/regulator/lubricator components without unthreading your air line connections. The blocks remain connected to your pipe while you replace components between them.
For technical drawings and 3-D models, click on a part number.
Regulators | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Overall | Joiner Clamps | End Block Sets | |||||||||||||
Manufacturer Series | Inlet | Outlet | Max. Flow Rate | Max. Pressure, psi | Gauge Included | Wd. | Ht. | Max. Temp., °F | Regulating Accuracy | Pressure Regulating Range, psi | Each | Each | Each | |||
Aluminum Housing | ||||||||||||||||
Series No. 73—NPT Female Inlet and Outlet | ||||||||||||||||
R73 | 1/4 | 1/4 | 91 scfm @ 100 psi | 300 | Yes | 2 3/4" | 5 3/8" | 125° | ±3% | 5-150 | 0000000 | 000000 | 000000 | 000000 | 0000000 | 000000 |
R73 | 3/8 | 3/8 | 144 scfm @ 100 psi | 300 | Yes | 2 3/4" | 5 3/8" | 125° | ±3% | 5-150 | 0000000 | 00000 | 000000 | 00000 | 0000000 | 00000 |
R73 | 1/2 | 1/2 | 144 scfm @ 100 psi | 300 | Yes | 2 3/4" | 5 3/8" | 125° | ±3% | 5-150 | 0000000 | 00000 | 000000 | 00000 | 0000000 | 00000 |
Series No. 74—NPT Female Inlet and Outlet | ||||||||||||||||
R74 | 3/8 | 3/8 | 208 scfm @ 100 psi | 300 | Yes | 3 1/4" | 6 3/4" | 125° | ±3% | 5-150 | 0000000 | 00000 | 000000 | 00000 | 0000000 | 00000 |
R74 | 1/2 | 1/2 | 220 scfm @ 100 psi | 300 | Yes | 3 1/4" | 6 3/4" | 125° | ±3% | 5-150 | 0000000 | 00000 | 000000 | 00000 | 0000000 | 00000 |
R74 | 3/4 | 3/4 | 220 scfm @ 100 psi | 300 | Yes | 3 1/4" | 6 3/4" | 125° | ±3% | 5-150 | 0000000 | 00000 | 000000 | 00000 | 0000000 | 00000 |
Connect two or more of these manifold regulators to meet multiple pressure requirements from a single air supply—set a different output pressure with each regulator. Each regulator has two regulated outlets and one unregulated outlet. Regulators are relieving style, so they exhaust when the downstream pressure exceeds the set pressure. Install in your air line after filters.
Mounting brackets (sold separately) allow you to attach manifold regulators to a wall or equipment.
Joiner clamps (sold separately) connect manifold regulators to each other and other Norgren modular components with the same series number. They come with mounting brackets.
End block sets (sold separately) allow you to swap out filter/regulator/lubricator components without unthreading your air line connections. The blocks remain connected to your pipe while you replace components between them.
Regulator Manifolds | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Joiner Clamps | End Block Sets | ||||||||||||
Manufacturer Series | Inlet Pipe Size | Outlet Pipe Size (No. of Outlets) | Max. Flow Rate | Max. Pressure, psi | Wd. | Ht. | Max. Temp., °F | Choose a Pressure Regulating Range, psi | Each | Each | Each | |||
Zinc Housing | ||||||||||||||
Series No. 72—NPT Female Inlet and Outlets | ||||||||||||||
R72 | 1/4 | 1/4 (1 Unregulated), 1/4 (1 Regulated), 1/8 (1 Regulated) | 83 cfm @ 100 psi | 300 | 2" | 4 1/4" | 150° | 000000 | 000000 | 000000 | 000000 | 0000000 | 000000 | |
R72 | 3/8 | 3/8 (1 Unregulated), 1/4 (1 Regulated), 1/8 (1 Regulated) | 83 cfm @ 100 psi | 300 | 2" | 4 1/4" | 150° | 000000 | 00000 | 000000 | 00000 | 0000000 | 00000 | |
Aluminum Housing | ||||||||||||||
Series No. 74—NPT Female Inlet and Outlets | ||||||||||||||
R74 | 1/2 | 1/2 (1 Unregulated), 1/2 (1 Regulated), 1/8 (1 Regulated) | 160 scfm @ 100 psi | 300 | 3 1/8" | 6 5/8" | 175° | 5-150 | 00000000 | 000000 | 000000 | 00000 | 0000000 | 00000 |
R74 | 3/4 | 3/4 (1 Unregulated), 1/2 (1 Regulated), 1/8 (1 Regulated) | 160 scfm @ 100 psi | 300 | 3 1/8" | 6 5/8" | 175° | 5-150 | 00000000 | 000000 | 000000 | 00000 | 0000000 | 00000 |
A filter and regulator joined top-to-bottom, these filter/regulators fit in the same space as a filter alone. They provide clean compressed air at your required pressure. Filter has a clear bowl so you can see inside to monitor contents. Regulator is relieving style, so it exhausts when the downstream pressure exceeds the set pressure.
Mounting brackets (sold separately) allow you to attach the filter/regulator to a wall or equipment.
Joiner clamps (sold separately) connect the filter/regulator to another Norgren modular component with the same series number. They come with mounting brackets.
End block sets (sold separately) allow you to swap out filter/regulator/lubricator components without unthreading your air line connections. The blocks remain connected to your pipe while you replace components between them.
For technical drawings and 3-D models, click on a part number.
Filter/Regulators | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Overall | End Block Sets | |||||||||||
Mfr. Series | Inlet | Outlet | Max. Flow Rate | Pressure Regulating Range, psi | Max. Pressure, psi | Max. Temp., °F | Removes Particle Size Down To, microns | Ht. | Wd. | Each | Each | ||
Polycarbonate Plastic Bowl—Clear with Automatic Drain | |||||||||||||
B07 | 1/8 | 1/8 | 13 scfm @ 100 psi | 5-100 | 150 | 125° | 5 | 6 3/8" | 1 5/8" | 0000000 | 000000 | 000000 | 00 |
B07 | 1/4 | 1/4 | 14 scfm @ 100 psi | 5-100 | 150 | 125° | 5 | 6 3/8" | 1 5/8" | 0000000 | 00000 | 0000000 | 000000 |
Filter/Regulators | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Overall | End Block Sets | |||||||||||
Mfr. Series | Inlet | Outlet | Max. Flow Rate | Pressure Regulating Range, psi | Max. Pressure, psi | Max. Temp., °F | Removes Particle Size Down To, microns | Ht. | Wd. | Each | Each | ||
Polycarbonate Plastic Bowl—Clear with Steel Guard and Automatic Drain | |||||||||||||
B73G | 1/4 | 1/4 | 60 scfm @ 100 psi | 5-150 | 150 | 125° | 5 | 9 5/8" | 2 3/4" | 0000000 | 0000000 | 0000000 | 000000 |
B73G | 3/8 | 3/8 | 42 scfm @ 100 psi | 5-150 | 150 | 125° | 5 | 9 5/8" | 2 3/4" | 0000000 | 000000 | 0000000 | 00000 |
B73G | 1/2 | 1/2 | 66 scfm @ 100 psi | 5-150 | 150 | 125° | 5 | 9 5/8" | 2 3/4" | 0000000 | 000000 | 0000000 | 00000 |
Filter/Regulators | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Overall | Replacement Filter Elements | Replacement Filter Bowls | End Block Sets | |||||||||||||
Mfr. Series | Inlet | Outlet | Max. Flow Rate | Pressure Regulating Range, psi | Max. Pressure, psi | Max. Temp., °F | Removes Particle Size Down To, microns | Ht. | Wd. | Each | Each | Each | Each | ||||
Polycarbonate Plastic Bowl—Clear with Steel Guard and Automatic Drain | |||||||||||||||||
B74G | 3/8 | 3/8 | 95 scfm @ 100 psi | 5-150 | 150 | 125° | 5 | 11 3/8" | 3 1/4" | 0000000 | 0000000 | 0000000 | 000000 | 000000 | 00 | 0000000 | 000000 |
B74G | 1/2 | 1/2 | 120 scfm @ 100 psi | 5-150 | 150 | 125° | 5 | 11 3/8" | 3 1/4" | 0000000 | 000000 | 0000000 | 00000 | 000000 | 00 | 0000000 | 00000 |
B74G | 3/4 | 3/4 | 150 scfm @ 100 psi | 5-150 | 150 | 125° | 5 | 11 3/8" | 3 1/4" | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 0000000 | 0000000 | 00000 |
A Norgren filter, regulator, and lubricator are combined to provide clean, lubricated compressed air at your required pressure. Regulator is relieving style, so it exhausts when the downstream pressure exceeds the set pressure. Filter and lubricator have a clear bowl so you can monitor the contents inside.
Stacked filter/regulator/lubricators require less horizontal space than inline FRLs. The filter and regulator are joined top-to-bottom with the lubricator on the side.
Mounting brackets allow you to attach the filter/regulator/lubricator to a wall or equipment.
Joiner clamps (sold separately) connect the filter/regulator/lubricator to another Norgren modular component with the same series number. They come with mounting brackets.
End block sets (sold separately) allow you to swap out filter/regulator/lubricator components without unthreading your air line connections. The blocks remain connected to your pipe while you replace components between them. They come with mounting brackets.
Filter/Regulator/Lubricators (FRLs) | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Overall | Joiner Clamps | End Block Sets | Replacement Seal Kits | ||||||||||||
Manufacturer Series | Inlet | Outlet | Max. Flow Rate | Max. Pressure, psi | Removes Particle Size Down To, microns | Pressure Regulating Range, psi | Ht. | Wd. | Each | Each | Each | Each | ||||
Inline with Clear Polycarbonate Plastic Bowl | ||||||||||||||||
C73A | 1/4 | 1/4 | 91 scfm @ 90 psi | 150 | 5 | 5-150 | 8" | 9 1/8" | 00000000 | 0000000 | 000000 | 000000 | 000000 | 00 | 000000 | 00 |
C73A | 3/8 | 3/8 | 208 scfm @ 90 psi | 150 | 5 | 5-150 | 10" | 9 1/8" | 00000000 | 000000 | 000000 | 00000 | 0000000 | 000000 | 0000000 | 000000 |
C73A | 1/2 | 1/2 | 220 scfm @ 90 psi | 150 | 5 | 5-150 | 8" | 9 1/8" | 00000000 | 000000 | 000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
Stacked with Clear Polycarbonate Plastic Bowl | ||||||||||||||||
C73H | 1/4 | 1/4 | 78 scfm @ 90 psi | 150 | 5 | 5-150 | 10" | 5 7/8" | 00000000 | 000000 | 000000 | 00000 | 000000 | 00 | 0000000 | 00000 |
C73H | 3/8 | 3/8 | 123 scfm @ 90 psi | 150 | 5 | 5-150 | 10" | 9 1/8" | 00000000 | 000000 | 000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
Filter/Regulator/Lubricators (FRLs) | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Overall | Joiner Clamps | End Block Sets | Replacement Seal Kits | ||||||||||||
Manufacturer Series | Inlet | Outlet | Max. Flow Rate | Max. Pressure, psi | Removes Particle Size Down To, microns | Pressure Regulating Range, psi | Ht. | Wd. | Each | Each | Each | Each | ||||
Inline with Clear Polycarbonate Plastic Bowl | ||||||||||||||||
C74A | 3/8 | 3/8 | 208 scfm @ 90 psi | 150 | 5 | 5-150 | 8 7/8" | 10 1/2" | 00000000 | 0000000 | 000000 | 000000 | 000000 | 00 | 0000000 | 000000 |
C74A | 1/2 | 1/2 | 220 scfm @ 90 psi | 150 | 5 | 5-150 | 8 7/8" | 10 1/2" | 00000000 | 000000 | 000000 | 00000 | 0000000 | 000000 | 0000000 | 00000 |
C74A | 3/4 | 3/4 | 220 scfm @ 90 psi | 150 | 5 | 5-150 | 8 7/8" | 10 1/2" | 00000000 | 000000 | 000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
Stacked with Clear Polycarbonate Plastic Bowl | ||||||||||||||||
C74H | 3/8 | 3/8 | 163 scfm @ 90 psi | 150 | 5 | 5-150 | 12" | 6 7/8" | 00000000 | 000000 | 000000 | 00000 | 000000 | 00 | 0000000 | 00000 |
C74H | 1/2 | 1/2 | 212 scfm @ 90 psi | 150 | 5 | 5-150 | 12" | 6 7/8" | 0000000 | 000000 | 000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
C74H | 3/4 | 3/4 | 220 scfm @ 90 psi | 150 | 5 | 5-150 | 12" | 6 7/8" | 0000000 | 000000 | 000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |