McMaster-Carr logo
    Filter by
    Inlet Pipe Size
    Industrial Info Compare
    Outlet Pipe Size
    Industrial Info Compare
    Inlet Thread Type
    Industrial Info Compare
    Maximum Outlet Pressure Gauge Measurement
    Inlet Gender
    Outlet Thread Type
    Industrial Info Compare
    Outlet Pressure Adjustment Method
    Outlet Connection Port
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    44 Products

    Cleaned and Bagged Pressure-Regulating Valves for Air and Inert Gas

    Image of Product. Front orientation. Pressure-Regulating Valves. Cleaned and Bagged Pressure-Regulating Valves for Air and Inert Gas.
    Often used for oxygen service and other high-purity applications, these valves are cleaned and bagged to meet CGA G-4.1 standards to prevent contamination. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Valves have two gauge ports. They are no-bleed style, so they keep process gases contained in the valve.
    Inlet
    Outlet
    Gauge Port
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Pipe
    Size
    Location
    Pressure Adjustment
    Method
    Pressure Gauge
    Included
    Pipe
    Size
    Location
    Connection
    End-to-End
    Lg.
    For Use With
    Temp. Range,
    ° F
    Specs.
    Met
    Choose an Outlet Pressure, psi
    Each
    NPT Female
     
    Brass Body—Buna-N Diaphragm and Fluoroelastomer Seal
    1/2
    Side5001/2
    SideT-HandleNo1/4
    SideNPT Female2 13/16"Nitrogen, Oxygen, Argon, Helium, Neon-40 to 165CGA G-4.1
    5 to 55
    ,
    40 to 110
    ,
    100 to 200
    ,
    175 to 300
    000000000000000
    3/4
    Side5003/4
    SideT-HandleNo1/4
    SideNPT Female3 5/16"Nitrogen, Oxygen, Argon, Helium, Neon-40 to 165CGA G-4.1
    5 to 55
    ,
    40 to 110
    ,
    100 to 200
    ,
    175 to 275
    00000000000000
    1
    Side5001
    SideT-HandleNo1/4
    SideNPT Female3 5/16"Nitrogen, Oxygen, Argon, Helium, Neon-40 to 165CGA G-4.1
    5 to 55
    ,
    40 to 110
    ,
    100 to 200
    ,
    175 to 275
    00000000000000
     

    Clean Room Pressure-Regulating Valves for Water, Air, and Inert Gas

    Image of Product. Front orientation. Pressure-Regulating Valves. Clean Room Pressure-Regulating Valves for Water, Air, and Inert Gas.
    To maintain contaminant-free standards in clean room environments, these valves come cleaned and bagged to Fed. Std. Class 100 and ISO Class 5 clean room standards and have a 316 stainless steel body with a smooth finish to resist dust collection. They automatically reduce a high, variable inlet pressure to a lower, stable output pressure. Adjust the outlet pressure within the range. Valves are no-bleed style, so they keep process media contained within the valve.
    Inlet
    Outlet
    Thread
    Size
    Location
    Max. Pressure,
    psi
    Thread
    Size
    Location
    Pressure Range,
    psi
    Pressure Adjustment
    Method
    Pressure Gauge
    Included
    End-to-End
    Lg.
    Panel Cutout
    Dia.
    Clean Room Std.
    For Use With
    Temp. Range,
    ° F
    Each
    Metric Female
     
    316 Stainless Steel Body—Fluoroelastomer Diaphragm and 316 Stainless Steel Seal
    M5 × 0.8 mmSide150M5 × 0.8 mmSide1.4 to 28KnobNo1 3/16"1 1/4"Fed. Std. Class 100, ISO Class 5
    Deionized Water, Air, Nitrogen, Oxygen41 to 140000000000000000
    M5 × 0.8 mmSide150M5 × 0.8 mmSide7 to 99KnobNo1 3/16"1 1/4"Fed. Std. Class 100, ISO Class 5
    Deionized Water, Air, Nitrogen, Oxygen41 to 14000000000000000
     

    ASME-Code Fast-Acting Pressure-Relief Valves for Cryogenic Fluids

    These valves meet ASME Code Section VIII for use with cryogenic pressure vessels. Rated for use with argon, carbon dioxide, helium, hydrogen, methane, nitrogen, and oxygen, they are cleaned and bagged for oxygen service and other high-purity applications. All spring fully open at the set pressure and remain open until the system pressure is restored below the set pressure. Attach a drain line to the threaded relief port for remote discharge.
    NPT Male Inlet and NPT Female Relief Port
    Image of Product. Front orientation. Pressure-Relief Valves. ASME-Code Fast-Acting Pressure-Relief Valves for Cryogenic Fluids.
    Inlet
    Relief
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Port Pipe
    Size
    Port
    Location
    Shape
    Overall
    Ht.
    For Use With
    Temp. Range,
    ° F
    Valve
    Type
    Certification
    Choose a Set Pressure, psi
    Each
     
    Brass Body—Brass Seal
    1/2
    Bottom6003/4
    Side90° Elbow6 9/16"Argon, Carbon Dioxide, Helium, Hydrogen, Methane, Nitrogen, Oxygen-320 to 150Pop SafetyASME BPVC.VIII
    20
    ,
    30
    ,
    40
    ,
    50
    ,
    60
    ,
    70
    ,
    80
    ,
    90
    ,
    100
    ,
    110
    ,
    120
    ,
    130
    ,
    140
    ,
    150
    ,
    160
    ,
    170
    ,
    180
    ,
    190
    ,
    200
    ,
    210
    ,
    220
    ,
    230
    ,
    240
    ,
    250
    ,
    260
    ,
    270
    ,
    280
    ,
    290
    ,
    300
    00000000000000
    3/4
    Bottom6001
    Side90° Elbow6 9/16"Argon, Carbon Dioxide, Helium, Hydrogen, Methane, Nitrogen, Oxygen-320 to 150Pop SafetyASME BPVC.VIII
    20
    ,
    30
    ,
    40
    ,
    50
    ,
    60
    ,
    70
    ,
    80
    ,
    90
    ,
    100
    ,
    110
    ,
    120
    ,
    130
    ,
    140
    ,
    150
    ,
    160
    ,
    170
    ,
    180
    ,
    190
    ,
    200
    ,
    210
    ,
    220
    ,
    230
    ,
    240
    ,
    250
    ,
    260
    ,
    270
    ,
    280
    ,
    290
    ,
    300
    0000000000000
     

    Tank-Mount Pressure-Regulating Valves for Air and Inert Gas

    These valves automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. All have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Valves have a gauge to monitor outlet pressure and a gauge to monitor inlet pressure from the tank.
    Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
    Single Stage
    Image of Product. UNF Male Outlet × Female Inlet Single-Stage Valves with T-Handle. Front orientation. Pressure-Regulating Valves. Tank-Mount Pressure-Regulating Valves for Air and Inert Gas, Single Stage, Female Inlet, UNF Outlet Thread, Male Outlet, Outlet-Pressure-Adjustment T-Handle.
    Image of Product. UNF Male Outlet × Female Inlet Single-Stage Valves with Knob. Front orientation. Pressure-Regulating Valves. Tank-Mount Pressure-Regulating Valves for Air and Inert Gas, Single Stage, Female Inlet, UNF Outlet Thread, Male Outlet, Outlet-Pressure-Adjustment Knob.

    UNF Male Outlet × Female

    Inlet Single-Stage

    Valves with T-Handle

    UNF Male Outlet ×

    Female Inlet

    Single-Stage Valves

    with Knob

    Single-stage valves reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank. They’re best for applications where a constant outlet pressure isn’t critical.
    Brass Body—Valves with a brass body have a longer service life than valves with a brass and steel body.
    Stainless Steel Diaphragm—Valves with a stainless steel diaphragm can withstand harsh environments.
    Inlet
    Outlet
    Material
    CGA
    No.
    Location
    Thread
    Direction
    Pressure Gauge
    Reading Range, psi
    Location
    Thread
    Direction
    Pressure
    Range, psi
    Pressure Adjustment
    Method
    Body
    Seal
    Diaphragm
    Temp. Range,
    ° F
    Each
    For Oxygen
     
    9/16"-18 UNF Male Outlet × NGO Female Inlet
    540
    SideRight Hand
    0 to 4,000SideLeft Hand
    0 to 50KnobBrassPTFENeoprene-20 to 120000000000000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 50T-HandleBrassPTFEStainless Steel-20 to 12000000000000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 125T-HandleBrassPTFERubber-20 to 1200000000000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 125T-HandleBrassPTFEStainless Steel-20 to 1200000000000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 145KnobBrass/SteelPTFERubber-20 to 1200000000000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 200T-HandleBrassPTFERubber-20 to 120000000000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 200T-HandleBrassPTFEStainless Steel-20 to 12000000000000000
     
    Two Stage
    Image of Product. NPT Female Outlet × Female Inlet Two-Stage Valves with T-Handle. Front orientation. Pressure-Regulating Valves. Tank-Mount Pressure-Regulating Valves for Air and Inert Gas, Two Stage, NPT Outlet Thread, Female Outlet, Female Inlet, Outlet-Pressure-Adjustment T-Handle.
    Image of Product. UNF Male Outlet × Female Inlet Two-Stage Valves with T-Handle. Front orientation. Pressure-Regulating Valves. Tank-Mount Pressure-Regulating Valves for Air and Inert Gas, Two Stage, Female Inlet, UNF Outlet Thread, Male Outlet, Outlet-Pressure-Adjustment T-Handle.

    NPT Female Outlet ×

    Female Inlet Two-Stage

    Valves with T-Handle

    UNF Male Outlet ×

    Female Inlet Two-Stage

    Valves with T-Handle

    Two-stage valves progressively reduce pressure over two steps for more consistent outlet pressure at all times. They’re often used in applications that require a constant outlet pressure regardless of the tank level.
    Brass Body—Valves with a brass body have a longer service life than valves with a brass and steel body.
    Stainless Steel Diaphragm—Valves with a stainless steel diaphragm can withstand harsh environments.
    Inlet
    Outlet
    Material
    CGA
    No.
    Location
    Thread
    Direction
    Pressure Gauge
    Reading Range, psi
    Location
    Thread
    Direction
    Pressure
    Range, psi
    Pressure Adjustment
    Method
    Body
    Seal
    Diaphragm
    Temp. Range,
    ° F
    Each
    For Oxygen
     
    1/4 NPT Female Outlet × NGO Female Inlet
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 250T-HandleBrassPTFENeoprene-20 to 12000000000000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 250T-HandleBrassPTFEStainless Steel-20 to 1200000000000000
     
    9/16"-18 UNF Male Outlet × NGO Female Inlet
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 50T-HandleBrassPTFENeoprene-20 to 12000000000000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 50T-HandleBrassPTFEStainless Steel-20 to 12000000000000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 125T-HandleBrass/SteelPTFERubber-20 to 120000000000000
    540
    SideRight Hand
    0 to 4,000SideRight Hand
    0 to 125T-HandleBrassPTFEStainless Steel-20 to 1200000000000000
     

    Long-Life Pressure-Regulating Valves for Cryogenic Liquids

    Image of Product. Front orientation. Pressure-Regulating Valves. Long-Life Pressure-Regulating Valves for Cryogenic Liquids.
    For a longer service life than standard valves for cryogenic liquids, these have a durable bronze body. All are cleaned and bagged for oxygen service and other high-purity applications. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Valves are designed to withstand the extreme cold of liquid argon, liquid carbon dioxide, liquid nitrogen, and liquid oxygen. They have an internal strainer to trap debris.
    Inlet
    Outlet
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Pipe
    Size
    Location
    Pressure Adjustment
    Method
    End-to-End
    Lg.
    For Use With
    Temp. Range,
    ° F
    Choose an Outlet Pressure, psi
    Each
    NPT Female
     
    Bronze Body—Bronze Diaphragm and PTFE Seal with Internal Strainer
    1/4
    Side4001/4
    SideScrew3 1/16"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    10 to 30
    ,
    75 to 250
    000000000000000
    1/2
    Side4001/2
    SideScrew4 1/2"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    10 to 30
    ,
    20 to 75
    ,
    20 to 100
    ,
    50 to 250
    00000000000000
    1
    Side4001
    SideScrew5 7/8"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    10 to 35
    ,
    20 to 60
    ,
    20 to 100
    ,
    75 to 250
    00000000000000
     

    Fast-Acting Pressure-Relief Valves for Cryogenic Liquids

    Cleaned and bagged for oxygen service and other high-purity applications, these valves can withstand the extreme cold of liquid argon, liquid nitrogen, and liquid oxygen. They spring fully open at the set pressure and remain open until the system pressure is restored below the set pressure. All have a vented relief port to exhaust discharge directly.
    NPT Male Inlet and Relief Vent
    Image of Product. Front orientation. Pressure-Relief Valves. Fast-Acting Pressure-Relief Valves for Cryogenic Liquids.
    Inlet
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Relief Port
    Location
    Shape
    Overall
    Ht.
    For Use With
    Temp. Range,
    ° F
    Valve
    Type
    Choose a Set Pressure, psi
    Each
     
    Brass Body—PTFE Seal
    1/4
    Bottom400Side90° Elbow2 5/16"Liquid Argon, Liquid Nitrogen, Liquid Oxygen-320 to 350Pop Safety
    5
    ,
    10
    ,
    15
    ,
    20
    ,
    25
    ,
    30
    ,
    40
    ,
    50
    ,
    88
    ,
    100
    ,
    110
    ,
    125
    ,
    150
    ,
    200
    ,
    220
    ,
    250
    ,
    300
    ,
    325
    ,
    350
    ,
    400
    0000000000000
     

    Tank-Mount High-Pressure-Regulating Valves for Air and Inert Gas

    Often used for pressure-vessel testing and other high-pressure applications, these valves can handle at least seven times the outlet pressure of standard tank-mount pressure-regulating valves. They automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. All have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Outlet fittings are Swagelok® for a leak-free seal around hard metal tubing in high-pressure lines. Also known as instrumentation fittings, Swagelok® fittings are compatible with Parker A-Lok, Gyrolok, Bilok, and Tylok fittings. Valves have a gauge to monitor outlet pressure and a gauge to monitor inlet pressure from the tank. They are single stage and reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank.
    Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
    For Oxygen
    Image of Product. Female Outlet × Female Inlet Straight With Knob. Front orientation. Pressure-Regulating Valves. Tank-Mount High-Pressure-Regulating Valves for Air and Inert Gas, Female Inlet, Female Outlet, Single Stage, Outlet-Pressure-Adjustment Knob.

    Female Outlet × Female

    Inlet Straight With Knob

    Inlet
    Outlet
    Material
    CGA
    No.
    Location
    Thread
    Direction
    Pressure Gauge
    Reading Range, psi
    No. of
    Stages
    For Tube
    OD
    Location
    Pressure Range,
    psi
    Pressure Adjustment
    Method
    Shape
    Body
    Seal
    Diaphragm
    Temp. Range,
    ° F
    Each
    NGO Female Inlet × Swagelok® Female Outlet
    540
    SideRight Hand
    0 to 4,000Single1/4"Side0 to 1,500KnobStraightBrassPCTFENeoprene-20 to 12000000000000000
    540
    SideRight Hand
    0 to 4,000Single1/4"Side0 to 2,500KnobStraightBrassPCTFENeoprene-20 to 1200000000000000
     

    Pressure-Relief Valves for Cryogenic Applications

    Image of Product. Front orientation. Pressure-Relief Valves. Pressure-Relief Valves for Cryogenic Applications.
    Cleaned and bagged to meet CGA G-4.1 for oxygen service and other high-purity applications, these valves are built to withstand the extreme cold of liquid carbon dioxide, liquid nitrogen, and liquid oxygen. They begin opening at the set pressure and fully open at about 10% over the set pressure. Valves begin closing as pressure drops and fully close when the system pressure is restored below the set pressure. Set pressure is not adjustable. Valves are not intended for direct contact with cryogenic liquids.
    Riser Tubes—Riser tubes (sold separately) are required to convert cryogenic liquids into gases before they contact the valve. 3/8 NPT valve requires a 1/2 NPT × 3/8 NPT bushing when using a riser.
    Adapters—Adapters (sold separately) convert the valve relief-port connection from UNEF female threads to NPT female threads.
    Valves
    Riser Tubes
    Adapters
    Inlet
    Relief
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Port Thread
    Size
    Port
    Location
    Overall
    Ht.
    For Use With
    Temp. Range,
    ° F
    Choose a Set Pressure, psi
    Each
    Each
    Each
    NPT Male Inlet and UNEF Female Relief Port
     
    Brass Body
    1/4
    Bottom6003/4"-20
    Top2 5/8"Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 165
    22
    ,
    35
    ,
    50
    ,
    75
    ,
    100
    ,
    125
    ,
    150
    ,
    200
    ,
    250
    ,
    300
    ,
    350
    ,
    400
    ,
    450
    000000000000000000000000000000000000000000
    3/8
    Bottom6003/4"-20
    Top2 5/8"Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 165
    22
    ,
    35
    ,
    50
    ,
    75
    ,
    100
    ,
    125
    ,
    150
    ,
    200
    ,
    250
    ,
    300
    ,
    350
    ,
    400
    ,
    450
    000000000000000000000000000000000000000
    1/2
    Bottom6003/4"-20
    Top2 13/16"Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 165
    22
    ,
    35
    ,
    50
    ,
    75
    ,
    100
    ,
    125
    ,
    150
    ,
    200
    ,
    250
    ,
    300
    ,
    350
    ,
    400
    ,
    450
    000000000000000000000000000000000000000
     

    Pressure-Regulating Valves for Cryogenic Liquids

    Image of Product. Front orientation. Pressure-Regulating Valves. Pressure-Regulating Valves for Cryogenic Liquids.
    These valves can withstand the extreme cold of liquid argon, liquid carbon dioxide, liquid nitrogen, and liquid oxygen. All are cleaned and bagged for oxygen service and other high-purity applications. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range.
    Inlet
    Outlet
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Pipe
    Size
    Location
    Pressure Adjustment
    Method
    End-to-End
    Lg.
    For Use With
    Temp. Range,
    ° F
    Choose an Outlet Pressure, psi
    Each
    NPT Female
     
    Brass Body—Bronze Diaphragm and PTFE Seal
    1/4
    Side6001/4
    SideScrew1 3/4"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    15 to 65
    ,
    75 to 175
    ,
    100 to 250
    000000000000000
    3/8
    Side6003/8
    SideScrew1 3/4"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    15 to 65
    ,
    75 to 175
    ,
    100 to 250
    00000000000000
     

    Vacuum Breakers for Chemicals

    A plastic body withstands pH neutralizing, cleaning, and plating solutions containing sodium hydroxide, methyl ethyl ketone, and other harsh chemicals. Also known as vacuum-breaking valves, these valves have vents that open when pressure drops to relieve vacuum conditions and prevent backward suction from drawing liquid into upstream piping.
    Diaphragm Check Valve
    Image of Product. Front orientation. Vacuum Breakers. Vacuum Breakers for Chemicals.
    Material
    CPVC Body
    PVC Body
    Inlet Pipe
    Size
    Outlet
    Pipe SIze
    For Pipe
    Schedule
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Min. Opening
    Pressure, psi
    End-to-End
    Lg.
    Seal
    DIaphragm
    For Use With
    Temp. Range,
    ° F
    Color
    Each
    Temp. Range,
    ° F
    Color
    Each
    NPT Female Inlet × NPT Female Outlet
    1/2
    1/2
    80
    Not Rated100 psi @ 75° F14 5/16"Fluoroelastomer
    Fluoroelastomer
    Beverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon40 to 180Light Gray0000000000000040 to 140Gray0000000000000
    3/4
    3/4
    80
    Not Rated100 psi @ 75° F14 5/8"Fluoroelastomer
    Fluoroelastomer
    Beverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon40 to 180Light Gray000000000000040 to 140Gray0000000000000
    1
    1
    80
    Not Rated100 psi @ 75° F15 1/8"Fluoroelastomer
    Fluoroelastomer
    Beverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon40 to 180Light Gray000000000000040 to 140Gray0000000000000
     
    Spring-Loaded Piston Check Valve
    Image of Product. Front orientation. Vacuum Breakers. Vacuum Breakers for Chemicals.
    Material
    CPVC Body
    PVC Body
    Inlet Pipe
    Size
    Outlet
    Pipe SIze
    For Pipe
    Schedule
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Min. Opening
    Pressure, psi
    End-to-End
    Lg.
    Seal
    Piston
    Spring
    For Use With
    Temp. Range,
    ° F
    Color
    Each
    Temp. Range,
    ° F
    Color
    Each
    NPT Female Inlet × NPT Female Outlet
    1 1/2
    1 1/2
    80
    Not Rated100 psi @ 75° F17 15/16"Fluoroelastomer
    CPVC
    PolymerBeverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon40 to 180Light Gray00000000000000———0
    2
    2
    80
    Not Rated100 psi @ 75° F18 1/2"Fluoroelastomer
    PVC
    PolymerBeverage, Food, Air, Ammonia, Argon, Carbon Dioxide, Chlorinated Water, Diesel Fuel, Drinking Water, Ethylene Glycol, Helium, Hydrochloric Acid, Kerosene, Krypton, Liquid Carbon Dioxide, Methanol (Methyl Alcohol), Methyl Ethyl Ketone (MEK), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oil, Oxygen, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Water, Xenon———040 to 140Gray00000000000000
     

    Tank-Mount Pressure-Regulating Valves for Cryogenic Cylinders

    Image of Product. Front orientation. Pressure-Regulating Valves. Tank-Mount Pressure-Regulating Valves for Cryogenic Cylinders.
    Automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. These valves can remove gases from liquid cryogenic cylinders. They have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Valves come with a gauge to monitor outlet pressure. They are single stage and reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank.
    Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
    Inlet
    Outlet
    For Use
    With
    CGA
    No.
    Location
    Thread
    Direction
    No. of
    Stages
    Thread
    Size
    Location
    Thread
    Direction
    Pressure
    Range, psi
    Pressure Adjustment
    Method
    Temp. Range,
    ° F
    Each
    UNF Male Outlet × NGO Female Inlet
     
    Brass Body—Stainless Steel Diaphragm and PTFE Seal
    Oxygen540
    SideRight Hand
    Single9/16"-18
    BottomRight Hand
    0 to 125T-Handle-20 to 12000000000000000
     
    back to top