Sets include a variety of electrical and valve lockouts as well as padlocks. The padlocks, hasps, and lockouts are red. They help you comply with OSHA 1910.147 procedures for the control of energy sources that could injure workers.
For Use With | Includes | Specifications Met | Each | |
Electrical Controls, Valves | 1 Each: Cable Lockout 1 Each: Circuit Breaker Padlock 1 Each: Lockout Hasp 1 Each: Snap-On Lockout Hasp 1 Each: Wall Switch Lockout 2 Each: Valve Handle Lockouts (Fits 3/8 to 4 Pipe Size and 11" Maximum Handle Length) 3 Each: 1/4" Shackle Diameter Keyed Alike Padlocks with Labels 3 Valve Wheel Lockouts (1 Each that fits 1"-3", 2"-5", and 4"-6 1/2" Diameter Wheels) 5 Each: Circuit Breaker Lockouts 12 Each: Tags Plastic Box | OSHA 1910.147 | 0000000 | 0000000 |
Electrical Controls, Electrical Plugs, Valves | 1 Each: 120/220V AC Plug Cover 1 Each: 250/550V AC Plug Cover 1 Each: Cable Lockout 1 Each: Lockout Hasp 1 Each: Snap-On Lockout Hasp 2 Each: Circuit Breaker Padlocks 2 Each: Valve Handle Lockouts (Fits 3/8 to 4 Pipe Size and 11" Maximum Handle Length) 2 Each: Wall Switch Lockouts 3 Valve Wheel Lockouts (1 Each that fits 1"-3", 2"-5", and 4"-6 1/2" Diameter Wheels) 6 Each: 1/4" Shackle Diameter Keyed Differently Padlocks with Labels 9 Each: Circuit Breaker Lockouts 24 Each: Tags Plastic Bag | OSHA 1910.147 | 0000000 | 000000 |
The padlocks and hasp are red. They help you comply with OSHA 1910.147 procedures for the control of energy sources that could injure workers.
For Use With | Includes | Specifications Met | Each | |
Electrical Controls | 1 Each: Lockout Hasp 3 Each: 1/4" Shackle Diameter Keyed Alike Padlocks with Labels 12 Each: Tags Waist Pouch | OSHA 1910.147 | 0000000 | 000000 |
Lock out the on/off or emergency-stop buttons on machinery to prevent accidental or unauthorized startups, such as during maintenance. Install these covers over the buttons and use a padlock to temporarily deny access to them. The locked covers let workers know the equipment is off for safety.
To comply with OSHA 1910.147 lockout requirements for maintaining machinery, you must cut off the electricity at the circuit in addition to disabling the push button.
Removable covers twist on and off a mounted base that fits around a button. The included labels help you identify the buttons.
Hinged covers have a door that you can flip open for access to the button when the lockout is complete. These covers fit 22 mm buttons; snap off the tabs around the mounting hole to fit 30 mm buttons.
Often used with emergency-stop buttons, crossbar covers have a bar that locks a button in the off position.
Covers | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Mounting Bases | |||||||||||
For Panel Cutout Dia. | Dia. | Dp. | For Max. No. of Padlocks | For Max. Padlock Shackle Dia. | Label Included | Includes | Specifications Met | Choose a Color | Each | Each | ||
Plastic | ||||||||||||
16 mm (5/8") | 2 1/2" | 1 3/4" | 1 | 5/16" | Yes | Adhesive Backing for Mounting Base | OSHA 1910.147 | 0000000 | 000000 | 0000000 | 00000 | |
16 mm (5/8") | 2 1/2" | 3" | 1 | 5/16" | Yes | Adhesive Backing for Mounting Base | OSHA 1910.147 | 0000000 | 00000 | 0000000 | 0000 | |
22 mm (7/8") | 2 1/2" | 1 3/4" | 1 | 5/16" | Yes | Adhesive Backing for Mounting Base | OSHA 1910.147 | 0000000 | 00000 | 0000000 | 0000 | |
30 mm (1 3/16") | 1 7/8" | 2" | 1 | 5/16" | Yes | Adhesive Backing for Mounting Base | OSHA 1910.147 | 0000000 | 00000 | 0000000 | 0000 |
Overall | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Panel Cutout Dia. | Wd. | Ht. | Dp. | For Max. No. of Padlocks | For Max. Padlock Shackle Dia. | Specifications Met | Color | Each | |
Plastic | |||||||||
22 mm, 30 mm (7/8", 1 3/16") | 1 3/4" | 1 3/4" | 1 7/8" | 1 | 5/16" | OSHA 1910.147 | Clear | 0000000 | 000000 |
Mount this lockout over toggle- and rocker-style wall switches to make the switch inaccessible. Switches can be locked out in either the on or off position. When not in use, the cover flips up to allow normal switch operation. Lockout mounts using the screws from your switch cover plate.
Overall | |||||||||
---|---|---|---|---|---|---|---|---|---|
Lg. | Wd. | Dp. | For Max. No. of Padlocks | For Max. Padlock Shackle Dia. | Color | Language | Message | Each | |
Plastic | |||||||||
4 3/4" | 1 3/4" | 1" | 1 | 9/32" | Red | English/Spanish, English/French | Danger—Locked Out Do Not Remove/Peligro—Cerrado No Lo Quite, Danger—Locked Out Do Not Remove/Danger—Verrouille Ne Pas Enlever | 00000000 | 00000 |
Secure circuit breaker switches that don’t have a hole for a padlock. These lockouts isolate a single switch, so you don’t have to power down an entire electrical panel to service one machine. Clamp them onto a switch with the thumb screw and secure with a padlock (not included). These lockouts prevent injuries from unexpected startups, helping you comply with OSHA 1910.147 requirements for the control of hazardous energy.
For Max. Switch | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Voltage | Wd. | Thick. | Lg. | Wd. | Dp. | For Circuit Breaker Type | For Manufacturer | For Max. No. of Padlocks | For Max. Padlock Shackle Dia. | Temp. Range, °F | Color | Specifications Met | Each | |
Plastic | ||||||||||||||
120V AC, 277V AC | 5/8" | 3/8" | 2" | 1 1/8" | 1 1/2" | Single Pole | Square D | 1 | 9/32" | 0° to 175° | Red | OSHA 1910.147 | 00000000 | 000000 |
480V AC, 600V AC | 1 1/2" | 1/2" | 2 3/4" | 2 5/16" | 2" | Single Pole | Square D | 1 | 9/32" | 0° to 175° | Red | OSHA 1910.147 | 00000000 | 00000 |
480V AC, 600V AC | 2 1/4" | 7/8" | 3 3/4" | 3 3/4" | 2 1/2" | Single Pole | Square D | 1 | 5/16" | 0° to 175° | Red | OSHA 1910.147 | 00000000 | 00000 |
Secure a single breaker switch with multiple padlocks, so electricity stays safely off until everyone's done working. The key that unlocks these lockouts is at the end of a 2-ft. cable—wind it through the lock mount and secure by adding a padlock for each person working. The key is released only when all padlocks are removed.
Less disruptive than turning off an entire panel, these lockouts isolate a single circuit, keeping power flowing elsewhere. And because they're small and don't actually hold the padlocks, you'll still have room in your breaker box to flip adjacent switches on and off and even close the panel door.
Circuit breaker lockouts such as these help your organization comply with OSHA 1910.147, which requires electrical circuits to be locked out during maintenance in order to prevent injuries.
For Max. Switch | Overall | Lock Mount | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Circuit Breaker Switch Type | For Voltage | Wd. | Thick. | Lg. | Wd. | Dp. | For Circuit Breaker Type | For Manufacturer | For Max. No. of Padlocks | For Max. Padlock Shackle Dia. | Lg. | Wd. | Dp. | Type | Temp. Range, °F | Each | |
Plastic | |||||||||||||||||
No Hole | 120V, 277V | 1/2" | 7/16" | 2 3/8" | 3/4" | 1" | Single Pole | American Switch, Bryant, Challenger, Crouse Hinds, Federal Pacific Electric, Frank Adams, GE, ITE, Square D, Sylvania, Thomas & Betts, Westinghouse, Zinsoo | 7 | 5/16" | 4" | 13/16" | 11/16" | Adhesive Back | 0° to 250° | 00000000 | 000000 |
Through Hole | 120V, 277V | 1/2" | 5/16" | 1 7/8" | 3/4" | 1" | Single Pole | American Switch, Cutler Hammer, ITE, Square D | 7 | 5/16" | 4" | 13/16" | 11/16" | Adhesive Back | 0° to 250° | 00000000 | 00000 |
Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Max. No. of Padlocks | For Max. Padlock Shackle Dia. | Lg. | Wd. | Dp. | Mount Type | Temp. Range, °F | Specifications Met | Pkg. Qty. | Pkg. | |
Small Pack | ||||||||||
Plastic | ||||||||||
7 | 5/16" | 4" | 13/16" | 11/16" | Adhesive Back | 0° to 250° | OSHA 1910.147 | 1 | 00000000 | 00000 |
15 | 5/16" | 8" | 13/16" | 11/16" | Adhesive Back | 0° to 250° | OSHA 1910.147 | 1 | 00000000 | 00000 |
Large Pack | ||||||||||
Plastic | ||||||||||
7 | 5/16" | 4" | 13/16" | 11/16" | Adhesive Back | 0° to 250° | OSHA 1910.147 | 6 | 00000000 | 00000 |
15 | 5/16" | 8" | 13/16" | 11/16" | Adhesive Back | 0° to 250° | OSHA 1910.147 | 6 | 00000000 | 00000 |
Suitable for most major multipole breakers that have a tie bar, including GE, ITE, Sylvania, Challenger, Bryant, Westinghouse, Square D, and General Switch Co. This lockout prevents electrical circuits from being energized. It helps you comply with OSHA 1910.147 procedures for the control of energy sources that could injure workers.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Voltage | Lg. | Wd. | Dp. | For Circuit Breaker Type | For Manufacturer | For Max. No. of Padlocks | For Max. Padlock Shackle Dia. | Temp. Range, ° F | Color | Specifications Met | Each | |
Plastic | ||||||||||||
120V AC, 277V AC | 2 1/4" | 1 1/4" | 1 1/16" | Multipole | Bryant, Challenger, GE, General Switch, ITE, Square D, Sylvania, Westinghouse | 1 | 9/32" | 0° to 175° | Red | OSHA 1910.147 | 00000000 | 000000 |
Lockout works with most 120V AC circuit breakers that have a hole through the breaker lever. It prevents electrical circuits from being energized, helping you comply with OSHA 1910.147 requirements for the control of hazardous energy.
Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Voltage | Lg. | Wd. | Dp. | For Circuit Breaker Type | For Manufacturer | For Max. No. of Padlocks | For Max. Padlock Shackle Dia. | Temp. Range, ° F | Color | Specifications Met | Each | |
Plastic | ||||||||||||
120V AC | 2 1/8" | 13/16" | 5/16" | Single Pole | Square D | 1 | 9/32" | 0° to 175° | Red | OSHA 1910.147 | 00000000 | 00000 |
Choose an actuator and contact block to make your own switch. Actuators are rated NEMA 3S, 4X and 13 for protection from dust, outdoor environments, corrosion, oil, and washdowns. Use legend plates (not included) to label switches. BACO Controls switches are only compatible with BACO manufactured legend plates.
Padlockable covers prevent unauthorized use.
For technical drawings and 3-D models, click on a part number.
Dia. | For Max. Padlock Shackle Dia. | Material | Color | Environmental Rating | Each | |
2" | 5/16" | Plastic | Clear | IP65 | 000000 | 000000 |
Dia. | For Switch Action | For Push-Button Style | For Max. Padlock Shackle Dia. | Material | Manufacturer | Color | Each | |
2" | Maintained | Mushroom | 1/4" | Plastic | BACO Controls | Yellow | 0000000 | 000000 |