McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    10 Products
    About Selecting Thermal Insulation
    industrial info icon

    Compare R-value and temperature range to find the insulation material that best suits your application.

    Humidity-Resistant Paper Insulation Sheets

    Often used in high-humidity applications for its low moisture absorption, this flexible paper insulation is made of inorganic materials. It’s typically used in appliances and electrical devices. Insulation meets UL 94 V-0 and UL 94 5VA for flame resistance.
    93 lb/ft³ Density
    Image of Product. Front orientation. Insulation Sheets. Humidity-Resistant Paper Insulation Sheets.
    Wd.
    Lg.,
    ft.
    Insulation
    R Value
    Flexibility
    Temp. Range,
    ° F
    Heat Flow Rate
    @ Temp.
    Color
    Performance
    Flammability Rating
    Each
    0.015" Thick
    36"20.06Flexible0 to 2651.73 BTU/hr @ 355° FOff-WhiteFlame Resistant, Moisture Resistant, Humidity ResistantUL 94 V-0, UL 94 5VA
    0000000000000
     

    Lightweight Melamine Insulation Sheets

    The lowest-density insulation we offer, these sheets are made of lightweight melamine foam. To use outdoors, add metal jacketing or a coating.
    0.44 lb/ft³ Density
    Image of Product. Front orientation. Insulation Sheets. Lightweight Melamine Insulation Sheets, Sheets with Kraft Paper Facing.
    Image of Product. Sheets Without Facing. Front orientation. Insulation Sheets. Lightweight Melamine Insulation Sheets.

    Sheets with Kraft Paper

    Facing

    Sheets Without Facing

    Sheets with Kraft Paper Facing—Sheets with kraft paper facing have added impact resistance.
    Sheets with Kraft Paper Facing
    Facing
    Wd.
    Lg.,
    ft.
    Insulation
    R Value
    Flexibility
    Temp. Range,
    ° F
    Heat Flow Rate
    @ Temp.
    Color
    Performance
    Flammability Rating
    Temperature,
    ° F
    Color
    Each
    1/2" Thick
    24"41.9Flexible-40 to 3500.27 BTU/hr @ 75° FGrayLightweightASTM E84 25/50 for Flame and Smoke
    30 to 150White0000000000000
    24"81.9Flexible-40 to 3500.27 BTU/hr @ 75° FGrayLightweightASTM E84 25/50 for Flame and Smoke
    30 to 150White0000000000000
    48"81.9Flexible-40 to 3500.27 BTU/hr @ 75° FGrayLightweightASTM E84 25/50 for Flame and Smoke
    30 to 150White0000000000000
     
    1" Thick
    24"43.7Flexible-40 to 3500.27 BTU/hr @ 75° FGrayLightweightASTM E84 25/50 for Flame and Smoke
    30 to 150White000000000000
    24"83.7Flexible-40 to 3500.27 BTU/hr @ 75° FGrayLightweightASTM E84 25/50 for Flame and Smoke
    30 to 150White0000000000000
    48"83.7Flexible-40 to 3500.27 BTU/hr @ 75° FGrayLightweightASTM E84 25/50 for Flame and Smoke
    30 to 150White0000000000000
     
    2" Thick
    24"47.4Flexible-40 to 3500.27 BTU/hr @ 75° FGrayLightweightASTM E84 25/50 for Flame and Smoke
    30 to 150White0000000000000
    48"87.4Flexible-40 to 3500.27 BTU/hr @ 75° FGrayLightweightASTM E84 25/50 for Flame and Smoke
    30 to 150White0000000000000
     
    Tape
    back to top