About Pressure Transmitters
More
About Pressure Switches
More
Air Sensors for Differential Pressure





Use these sensors with differential pressure gauges and switches to measure the static pressure drop across air filters, cooling coils, and blowers in air-handling equipment. Install them in duct through a hole and connect to your gauge with tubing.
Sensors with pressure tubes give more accurate measurements in applications with high air flow. Style D is held in place with a magnet so you can move it for use in multiple locations.
For technical drawings and 3-D models, click on a part number.
| Style | For Tube ID | For Tube OD | Insertion Dp. | Tube Connection Type | Gender | Mount Type | Material | Features | Each | |
| A | 1/8"-3/16" | __ | __ | Barbed | Male | Screw On | Brass | __ | 0000000 | 00000 |
| B | __ | 1/4" | __ | Compression | Female | Screw On | Brass | __ | 0000000 | 0000 |
| C | 1/8"-3/16" | __ | 4" | Barbed | Male | Screw On | Brass | Pressure Tubes | 0000000 | 00000 |
| D | 3/16" | __ | 3" | Barbed | Male | Magnetic | Brass | Pressure Tubes | 0000000 | 00000 |
| E | __ | 1/4" | 4" | Compression | Female | Screw On | Brass | Pressure Tubes | 0000000 | 00000 |
Air Sensors

Also known as pitot tubes, these can be used with manometers to measure air flow rate. Sensors have inch graduation marks so you can monitor your insertion depth.
For technical drawings and 3-D models, click on a part number.
| For Tube ID | Insertion Dp. | OD | For Min. Duct Dia. | Tube Connection Type | Gender | Material | Each | |
| 1/4" | 8 5/8" | 5/16" | 10" | Tube Stem | Male | 304 Stainless Steel | 0000000 | 0000000 |
| 1/4" | 12 5/8" | 5/16" | 10" | Tube Stem | Male | 304 Stainless Steel | 0000000 | 000000 |
| 1/4" | 18 5/8" | 5/16" | 10" | Tube Stem | Male | 304 Stainless Steel | 0000000 | 000000 |
| 1/4" | 24 5/8" | 5/16" | 10" | Tube Stem | Male | 304 Stainless Steel | 0000000 | 000000 |
Differential Pressure Transmitters

- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±0.5%
- Pipe Connection: NPT Female
- Conduit Connection: NPT Female
- Housing Material: 316 Stainless Steel
- Connection Material: 316 Stainless Steel
- Temperature Range: 0° to 200° F
Measure the difference in pressure between two points in flow applications, such as heating, cooling, and pumping systems. These transmitters, also known as transducers, convert differential pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure range and output signal. Transmitters will only provide accurate readings within the rated pressure range. Maximum pressure is the maximum spike in pressure a transmitter can withstand without damage. Transmitters are accurate only within the pressure range, not up to the maximum pressure. All transmitters are rated IP66 and NEMA 4X for use in washdown and corrosive environments.
These transmitters connect using two wires to send a 4-20mA current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Mounting Holes | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pressure Range, psi | Max. Pressure, psi | Input Voltage | Pipe Size | For Conduit Trade Size | For No. of Wires | No. of Wire Leads | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Environmental Rating | Each | |
4-20mA Current Output—Screw Terminals | ||||||||||||||
| 0-5 | 50 | 10-35V DC | 1/4 | 1/2 | 2 | 2 | No | 1/4" | 2 | 2" | 1 7/16" | IP66, NEMA 4X | 0000000 | 0000000 |
| 0-10 | 50 | 10-35V DC | 1/4 | 1/2 | 2 | 2 | No | 1/4" | 2 | 2" | 1 7/16" | IP66, NEMA 4X | 0000000 | 000000 |
| 0-25 | 120 | 10-35V DC | 1/4 | 1/2 | 2 | 2 | No | 1/4" | 2 | 2" | 1 7/16" | IP66, NEMA 4X | 0000000 | 000000 |
| 0-50 | 250 | 10-35V DC | 1/4 | 1/2 | 2 | 2 | No | 1/4" | 2 | 2" | 1 7/16" | IP66, NEMA 4X | 0000000 | 000000 |
| 0-100 | 500 | 10-35V DC | 1/4 | 1/2 | 2 | 2 | No | 1/4" | 2 | 2" | 1 7/16" | IP66, NEMA 4X | 0000000 | 000000 |
| 0-150 | 750 | 10-35V DC | 1/4 | 1/2 | 2 | 2 | No | 1/4" | 2 | 2" | 1 7/16" | IP66, NEMA 4X | 0000000 | 000000 |
| 0-200 | 1,000 | 10-35V DC | 1/4 | 1/2 | 2 | 2 | No | 1/4" | 2 | 2" | 1 7/16" | IP66, NEMA 4X | 0000000 | 000000 |
| 0-300 | 1,200 | 10-35V DC | 1/4 | 1/2 | 2 | 2 | No | 1/4" | 2 | 2" | 1 7/16" | IP66, NEMA 4X | 0000000 | 000000 |
| 0-500 | 2,000 | 10-35V DC | 1/4 | 1/2 | 2 | 2 | No | 1/4" | 2 | 2" | 1 7/16" | IP66, NEMA 4X | 0000000 | 000000 |
High-Accuracy Differential Pressure Transmitters

- For Use With: Air, Water
- Accuracy: ±0.25%
- Pipe Connection: NPT Female
- Conduit Connection: NPT Female
- Housing Material: Aluminum
- Connection Material: 17-4 PH Stainless Steel
- Temperature Range: 0° to 175° F
At least twice as accurate as standard transmitters, these transmitters sense differential pressure at an accuracy of ±0.25%. Use them in laboratories or testing applications where the difference in pressure between two points needs to be measured with high accuracy. They convert differential pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. As the differential increases, the output signal from the transmitter will increase. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the pressure range and output signal of the transmitter. Transmitters will only provide accurate readings within the rated pressure range. Maximum pressure is the maximum spike in pressure a transmitter can withstand without damage. Transmitters are accurate only within the pressure range, not up to the maximum pressure. All transmitters are rated NEMA 4 for protection in washdown environments.
4-20mA current output transmitters connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
DC voltage output transmitters connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
For technical drawings and 3-D models, click on a part number.
| Pressure Range, psi | Max. Pressure, psi | Input Voltage | Pipe Size | For Conduit Trade Size | For No. of Wires | Mounting Hardware Included | Ht. | Wd. | Environmental Rating | Each | |
4-20mA Current Output—Screw Terminals | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 0-1 | 350 | 9-30V DC | 1/4 | 7/8 | 2 | Yes | 3 1/8" | 2 7/16" | NEMA 4 | 0000000 | 0000000 |
| 0-2 | 350 | 9-30V DC | 1/4 | 7/8 | 2 | Yes | 3 1/8" | 2 7/16" | NEMA 4 | 0000000 | 000000 |
| 0-5 | 350 | 9-30V DC | 1/4 | 7/8 | 2 | Yes | 3 1/8" | 2 7/16" | NEMA 4 | 0000000 | 000000 |
| 0-10 | 350 | 9-30V DC | 1/4 | 7/8 | 2 | Yes | 3 1/8" | 2 7/16" | NEMA 4 | 0000000 | 000000 |
| 0-25 | 350 | 9-30V DC | 1/4 | 7/8 | 2 | Yes | 3 1/8" | 2 7/16" | NEMA 4 | 0000000 | 000000 |
| 0-50 | 350 | 9-30V DC | 1/4 | 7/8 | 2 | Yes | 3 1/8" | 2 7/16" | NEMA 4 | 0000000 | 000000 |
Low-Pressure Differential Pressure Transmitters

- For Use With: Air, Argon, Nitrogen
- Accuracy: ±1%
- Tube Connection Type: Barbed
- Housing Material: Polycarbonate
- Temperature Range: 32° to 122° F
These transmitters are commonly used to monitor airflow and to indicate when filters in HVAC systems become clogged. They convert the difference in pressure between two points in a low-pressure system into an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. Transmitters will only provide accurate readings within the rated pressure range. They come with a calibration certificate traceable to NIST. Maximum pressure is the maximum spike in pressure a transmitter can withstand without damage. Transmitters are accurate only within the pressure range, not up to the maximum pressure. All transmitters are rated IP67 for protection in washdown environments.
These transmitters connect using three wires—two wires into the power supply and a separate wire that sends a voltage signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
Mounting Holes | Transmitters with Calibration Certificate Traceable to NIST | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pressure Range, in. of H2O | Max. Pressure, psi | Input Voltage | For Tube ID | For No. of Wires | For DIN Rail Ht., mm | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Each | |
0-10V DC Voltage Output—Screw Terminals | ||||||||||||
Surface Mount | ||||||||||||
| -0.5 to 0.5, -1 to 1, -2.5 to 2.5, -5 to 5 | 10 | 13-30V DC | 3/16" | 3 | __ | No | 3/16" | 2 | 5 7/16" | 3 3/16" | 0000000 | 0000000 |
DIN Rail or Surface Mount | ||||||||||||
| -0.5 to 0.5, -1 to 1, -2.5 to 2.5, -5 to 5 | 10 | 13-30V DC | 3/16" | 3 | 35 | No | 3/16" | 2 | 5 7/16" | 3 3/16" | 0000000 | 000000 |
Hazardous Location Easy-Setup Differential Pressure Transmitters

- For Use With: Air, Argon, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±0.075%
- Pipe Connection: NPT Female
- Housing Material: Aluminum
- Connection Material: Hastelloy
- Temperature Range: -40° to 185° F
For use in hazardous locations, these transmitters safely measure the difference in pressure between two process lines in flow applications—such as heat exchangers, chillers, and pumps. They meet NEC safety standards, so they protect against an explosion where flammable gases and vapors are present.
Automatically compensating for error from temperature fluctuations or vibration, these transmitters don’t require additional programming into your receiving device to correct these factors. Set the pressure range with the keypad, select the unit of measure, and zero the transmitter. They convert differential pressure into an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers (PLCs), and motor speed controls, to monitor pressure or control equipment. Transmitters will only provide accurate readings within the rated pressure range. Maximum pressure is the greatest spike in pressure a transmitter can tolerate without damage. Transmitters are accurate only within the pressure range, not up to the maximum pressure. Rated IP66 and NEMA 4X, they protect against dirt, dust, corrosion, weather, and washdowns, and the hastelloy connection protects against harsh chemicals.
Most often, these transmitters connect using two wires to send a 4-20mA current output. The same wire that sends a signal to the receiver also powers the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices. Three- and four-wire configurations are also possible.
For technical drawings and 3-D models, click on a part number.
Mounting Holes | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pressure Range | Max. Pressure, psi | Input Voltage | Pipe Size | For No. of Wires | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Communication Protocol | Environmental Rating | Each | |
4-20mA Current Output—Screw Terminals | |||||||||||||
| 0-24 in. of H2O | 3,625 | 11-55V DC | 1/4 | 2, 3, 4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | NEC Class I Divisions 1, 2 Groups A, B, C, D; IP66; NEMA 4X | 0000000 | 000000000 |
| 0-160 in. of H2O | 5,800 | 11-55V DC | 1/4 | 2, 3, 4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | NEC Class I Divisions 1, 2 Groups A, B, C, D; IP66; NEMA 4X | 0000000 | 00000000 |
| 0-1,000 in. of H2O | 5,800 | 11-55V DC | 1/4 | 2, 3, 4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | NEC Class I Divisions 1, 2 Groups A, B, C, D; IP66; NEMA 4X | 0000000 | 00000000 |
| 0-145 psi | 5,800 | 11-55V DC | 1/4 | 2, 3, 4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | NEC Class I Divisions 1, 2 Groups A, B, C, D; IP66; NEMA 4X | 0000000 | 00000000 |
| 0-435 psi | 5,800 | 11-55V DC | 1/4 | 2, 3, 4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | NEC Class I Divisions 1, 2 Groups A, B, C, D; IP66; NEMA 4X | 0000000 | 00000000 |
| 0-1,450 psi | 5,800 | 11-55V DC | 1/4 | 2, 3, 4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | NEC Class I Divisions 1, 2 Groups A, B, C, D; IP66; NEMA 4X | 0000000 | 00000000 |
Easy-Setup Differential Pressure Transmitters

- For Use With: Air, Argon, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±0.075%
- Pipe Connection: NPT Female
- Housing Material: Aluminum
- Connection Material: Hastelloy
- Temperature Range: -40° to 185° F
Measure the difference in pressure between two process lines in flow applications such as heat exchangers, chillers, and pumps. These transmitters automatically compensate for error introduced by vibration as well as temperature fluctuations, so you do not need to program your receiving device to correct for these factors. Use the keypad to set the pressure range, choose the unit of measure, and zero the transmitter. These transmitters convert differential pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. Transmitters will only provide accurate readings within the rated pressure range. Maximum pressure is the maximum spike in pressure a transmitter can withstand without damage. Transmitters are accurate only within the pressure range, not up to the maximum pressure. All transmitters meet IP66 and NEMA 4X for use in washdown and corrosive environments and have a hastelloy diaphragm to resist harsh chemicals.
These transmitters typically connect using two wires to send a 4-20mA current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices. They can also be configured using three or four wires.
For technical drawings and 3-D models, click on a part number.
Mounting Holes | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pressure Range | Max. Pressure, psi | Input Voltage | Pipe Size | For No. of Wires | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Communication Protocol | Environmental Rating | Each | |
4-20mA Current Output—Screw Terminals | |||||||||||||
| 0-24 in. of H2O | 3,625 | 11-55V DC | 1/4 | 2, 3, 4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | 0000000 | 000000000 |
| 0-160 in. of H2O | 5,800 | 11-55V DC | 1/4 | 2, 3, 4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | 0000000 | 00000000 |
| 0-1,000 in. of H2O | 5,800 | 11-55V DC | 1/4 | 2, 3, 4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | 0000000 | 00000000 |
| 0-145 psi | 5,800 | 11-55V DC | 1/4 | 2, 3, 4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | 0000000 | 00000000 |
| 0-435 psi | 5,800 | 11-55V DC | 1/4 | 2, 3, 4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | 0000000 | 00000000 |
| 0-1,450 psi | 5,800 | 11-55V DC | 1/4 | 2, 3, 4 | No | 7/16" | 8 | 7 7/8" | 5 1/4" | HART | IP66, NEMA 4X | 0000000 | 00000000 |
Low Differential Pressure Switches

- For Use With: Air
- Connection Material: Aluminum
- Connection: NPT Female
- Switching Current: 15A
- Switching Voltage: 120V AC/240V AC/480V AC
Often used with ovens, dryers, and HVAC systems, these switches detect small differences in pressure. When the differential pressure exceeds your setpoint, the switch is activated. Use them to automate controls or activate an alarm in your process. Switches are single pole, double throw (SPDT), so they switch one circuit on or off. They can be wired normally open (NO) or normally closed (NC).
Temperature Range, °F | Conduit | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Setpoint, in. of H2O | Approximate Difference Between Setpoint and Reset Point, in. of H2O | Max. Pressure, in. of H2O | Accuracy | Pipe Size | Environment | Process | For Trade Size | Connection Gender | Specifications Met | Each | |
Zinc-Plated Steel Housing | |||||||||||
| 0.07-0.15 | 0.04 | 45 | ±3% | 1/8 | -30° to 180° | -30° to 180° | 7/8 | Female | CE Marked, CSA Certified, FM Approved, UL Recognized Component | 00000000 | 000000 |
| 0.15-0.55 | 0.1 | 45 | ±3% | 1/8 | -30° to 180° | -30° to 180° | 7/8 | Female | CE Marked, CSA Certified, FM Approved, UL Recognized Component | 00000000 | 00000 |
| 0.4-1.6 | 0.16 | 45 | ±3% | 1/8 | -30° to 180° | -30° to 180° | 7/8 | Female | CE Marked, CSA Certified, FM Approved, UL Recognized Component | 00000000 | 00000 |
| 1.4-5 1/2 | 0.3 | 45 | ±3% | 1/8 | -30° to 180° | -30° to 180° | 7/8 | Female | CE Marked, CSA Certified, FM Approved, UL Recognized Component | 00000000 | 00000 |
| 3-11 3/4 | 0.4 | 45 | ±3% | 1/8 | -30° to 180° | -30° to 180° | 7/8 | Female | CE Marked, CSA Certified, FM Approved, UL Recognized Component | 00000000 | 00000 |
| 4-20 | 0.5 | 45 | ±3% | 1/8 | -30° to 180° | -30° to 180° | 7/8 | Female | CE Marked, CSA Certified, FM Approved, UL Recognized Component | 00000000 | 00000 |
Washdown Differential Pressure Switches with Dial Indicator

- For Use With: Air, Hydraulic Fluid, Water
- Connection Material: Brass
- Connection: NPT Female
- Switching Current: 0.25A
- Switching Voltage: 120V AC
Not only are these switches rated NEMA 4X for protection from dirt, washdowns, and corrosion, they also have an indicator for additional monitoring at the source of your application. Switches operate based on the difference in pressure between two process lines. When the differential pressure exceeds your setpoint, the switch is activated. Use them to automate controls or activate an alarm in your process. Switches are single pole, double throw (SPDT), so they switch one circuit on or off. They can be wired normally open (NO) or normally closed (NC).
Temperature Range, °F | Conduit | Lens | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Setpoint, psi | Approximate Difference Between Setpoint and Reset Point, psi | Max. Pressure, psi | Accuracy | Pipe Size | Environment | Process | For Trade Size | Connection | Dia. | Material | Specifications Met | Each | |
Brass Housing | |||||||||||||
| 3-15 | 3 | 5,000 | ±2% | 1/4 | -40° to 175° | -40° to 175° | 1/2 | NPT Female | 3" | Glass | CSA Certified | 00000000 | 0000000 |
| 6-30 | 6 | 5,000 | ±2% | 1/4 | -40° to 175° | -40° to 175° | 1/2 | NPT Female | 3" | Glass | CSA Certified | 00000000 | 000000 |
| 10-50 | 10 | 5,000 | ±2% | 1/4 | -40° to 175° | -40° to 175° | 1/2 | NPT Female | 3" | Glass | CSA Certified | 00000000 | 000000 |
Differential Pressure Switches

- For Use With: Air, Hydraulic Fluid (Petroleum Based), Water
- Connection Material: Brass
- Connection: NPT Female
- Switching Current: 5A
- Switching Voltage: 120V AC/240V AC
These switches operate based on the difference in pressure between two process lines. When the differential pressure exceeds your setpoint, the switch is activated. Often used to indicate clogged filters, they are designed to automate controls or activate an alarm in your process. Switches are single pole, double throw (SPDT), so they switch one circuit on or off. They can be wired normally open (NO) or normally closed (NC). They are rated NEMA 4 to withstand washdowns, dust, and outdoor environments.
Temperature Range, °F | Conduit | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Setpoint, psi | Approximate Difference Between Setpoint and Reset Point, psi | Max. Pressure, psi | Accuracy | Pipe Size | Environment | Process | For Trade Size | Connection Gender | Environmental Rating | Specifications Met | Each | |
300 Series Stainless Steel and Polyester Plastic Housing | ||||||||||||
| 1-10 | 0.75 | 150 | ±1% | 1/4 | 30° to 160° | 0° to 200° | 7/8 | Female | NEMA 4 | UL Listed, C-UL Listed, CE Marked | 00000000 | 0000000 |
| 4-45 | 1 | 150 | ±1% | 1/4 | 30° to 160° | 0° to 200° | 7/8 | Female | NEMA 4 | UL Listed, C-UL Listed, CE Marked | 00000000 | 000000 |
Washdown Differential Pressure Switches

- For Use With: Air, Hydraulic Fluid (Petroleum Based), Water
- Connection Material: Brass
- Connection: NPT Female
- Switching Current: 5A
- Switching Voltage: 120V AC/240V AC
These switches are rated NEMA 4 for protection from dirt and washdowns. They operate based on the difference in pressure between two process lines. When the differential pressure exceeds your setpoint, the switch is activated. Often used to indicate clogged filters, they are designed to automate controls or activate an alarm in your process. Switches are single pole, double throw (SPDT), so they switch one circuit on or off. They can be wired normally open (NO) or normally closed (NC).
For technical drawings and 3-D models, click on a part number.
Temperature Range, °F | Conduit | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Setpoint, psi | Approximate Difference Between Setpoint and Reset Point, psi | Max. Pressure, psi | Accuracy | Pipe Size | Environment | Process | For Trade Size | Connection | Specifications Met | Each | |
300 Series Stainless Steel and Polyester Plastic Housing | |||||||||||
| 1-10 | 0.75 | 150 | ±1% | 1/4 | 30° to 160° | 0° to 200° | 7/8 | NPT Female | C-UL Listed, CE Marked, UL Listed | 00000000 | 0000000 |
| 4-45 | 1 | 150 | ±1% | 1/4 | 30° to 160° | 0° to 200° | 7/8 | NPT Female | C-UL Listed, CE Marked, UL Listed | 00000000 | 000000 |