Control Type Control Type |
|---|
|
Cooling Capacity Cooling Capacity |
|---|
|
Voltage Voltage |
|---|
|
Mounting Location Mounting Location |
|---|
|
Electrical Connection Type Electrical Connection Type |
|---|
|
Electrical Phase Electrical Phase |
|---|
|
Thermostat Included Thermostat Included |
|---|
|
Airflow Airflow |
|---|
|
Minimum Thermostat Temperature Minimum ThermostatTemperature |
|---|
|
Combined Energy Efficiency Ratio Combined EnergyEfficiency Ratio |
|---|
|
Estimated Yearly Energy Cost Estimated Yearly Energy Cost |
|---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
|---|
Maximum Thermostat Temperature Maximum ThermostatTemperature |
|---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
|---|
|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
|---|
|
About Air Conditioner Cooling Capacity
More
Mobile Air Conditioners

Choose this air conditioner for temporary spot cooling. Roll it to the area that needs to be cooled. It evaporates condensate so there is no tank to empty. This air conditioner has a NEMA 5-15 plug, which is a standard three-prong plug. Vent it to the outdoors with the included vent hose.
The higher the combined energy efficiency ratio, the more energy efficient the unit. Your operating costs will depend on your utility rates and use. The estimated yearly energy cost is based on electricity cost of $0.13 per kWh. For more information, visit www.ftc.gov/energy.
Overall | Thermostat | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cooling Cap., Btu/hr. | Combined Energy Efficiency Ratio | Estimated Yearly Energy Cost | Airflow, cfm | Current, A | Ht. | Wd. | Dp. | Plug Style | Included | Control | Temperature Range, °F | Includes | Each | |
120V AC, Single Phase—Three Prong Plug | ||||||||||||||
| 7,500 | 7.5 | $109 | 240 | 10.5 | 28 3/8" | 17 1/8" | 14 1/4" | NEMA 5-15 | No | Adjustable | 65° to 89° | 5 ft. Long Vent Hose, Vent Hose Mounting Flange | 000000 | 0000000 |
Mobile Evaporative Air Coolers

Also known as swamp coolers, use these air coolers wherever air conditioning is impractical. They take in water, which soaks into pads. When air is blown through the wet pads, the evaporation produces cool air. These air coolers have a direct-drive motor, which has fewer moving parts than belt-drive motors for less maintenance. All have a NEMA 5-15 plug, which is a standard three-prong plug.
Air Coolers | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Inlet Hose | Pads | Replacement Pads | ||||||||||||||
| Airflow, cfm | Reservoir Cap., gal. | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Dp. | Size | Thread Type | Housing Material | No. Required | No. Included | Each | Pkg. Qty. | Pkg. | ||
120V AC, Single Phase—Three-Prong Plug | |||||||||||||||||
| 2,400 | 20 | Variable | 1/4 | 3.4 | 42" | 29" | 27" | 3/4 | GHT | Plastic | 2 | 2 | 0000000 | 000000000 | 2 | 0000000 | 0000000 |
| 3,600 | 30 | Variable | 1/2 | 8.3 | 50" | 29" | 27" | 3/4 | GHT | Plastic | 2 | 2 | 0000000 | 00000000 | 2 | 0000000 | 000000 |
| Replacement Pump | 0000000 | Each | 0000000 |
High-Output Mobile Evaporative Air Coolers


Produce twice as much cool air as standard mobile evaporative air coolers. Also known as swamp coolers, use these air coolers wherever air conditioning is impractical. They take in water, which soaks into pads. When air is blown through the wet pads, the evaporation produces cool air.
Replacement pads are sold separately.
Air Coolers | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Inlet Hose | Pads | Replacement Pads | ||||||||||||||||
| Blade Dia. | Airflow, cfm | Reservoir Cap., gal. | Motor Speed, rpm | No. of Speeds | Power, hp | Current, A | Ht. | Wd. | Dp. | Size | Thread Type | Housing Material | No. Required | No. Included | Each | Pkg. Qty. | Pkg. | ||
120V AC, Single Phase—NEMA 5-15, Three-Prong Plug | |||||||||||||||||||
| 24" | 8,500 cfm | 55 | 1,100 | Variable | 1/2 | 9.2 | 70" | 55" | 33" | 3/4 | GHT | Plastic | 4 | 4 | 0000000 | 000000000 | 4 | 0000000 | 0000000 |
| 36" | 12,500 cfm | 60 | 1,100 | Variable | 1/2 | 9.3 | 77" | 67" | 34 1/2" | 3/4 | GHT | Plastic | 5 | 5 | 0000000 | 00000000 | 5 | 0000000 | 000000 |
120V AC, Single Phase—NEMA 5-20, Three-Prong Plug | |||||||||||||||||||
| 48" | 22,500 cfm | 65 | __ | Variable | 2 1/2 | 15.2 | 90" | 78" | 36" | 3/4 | GHT | Plastic | 6 | 6 | 0000000 | 00000000 | 6 | 0000000 | 000000 |
Digital Air Conditioner Charging and Testing Manifolds

Monitor refrigerant pressure on an LCD when servicing air conditioning systems. This manifold automatically calculates how much refrigerant is needed in a system based on measurements taken with its thermocouples.
Display | |||||||
|---|---|---|---|---|---|---|---|
| For Refrigerant Number | Valve Material | Pipe Connection | Type | Size | Batteries Included | Each | |
Three Valve | |||||||
| R-134A, R-22, R-404A, R-410A | Brass | 1/4 NPT × 1/4 NPT × 1/4 NPT | Digital | 5" | Yes | 0000000 | 0000000 |
Refrigerant Cylinder Charging Scales
Programmable Refrigerant Cylinder Charging Scales

Dispense programmed amounts of refrigerant. This scale weighs refrigerant cylinders to dispense the correct amount. It has an LCD to display weight in lbs. and kg.




























