About Sump, Water-Removal, Condensate, and Submersible Pumps
More
About Vacuum Pumps
More
About Process Pumps
More
About Drum Pumps
More
About Air Compressors
More
Harsh-Environment Self-Priming Water-Removal Pumps

This pump has a totally enclosed nonventilated (TENV) motor that is cooled by the liquid being pumped. Also known as a flexible impeller pump, it creates a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. Mount up to 6 feet above your liquid source. Pump can pass solids up to 1/4" in diameter without clogging, so there’s no need to filter sediment and debris. A handle makes it convenient for on-the-go removal of bilge water, waste oil, and spills. Pump can also be used to cool marine engines and drain liquid from holding tanks.
Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Ft. of Head, ft. | Max. Solids Dia. | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Intake Size | Discharge Size | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||
Plug with 8 ft. Cord | |||||||||||||
5 4/5 | 30 | 1/4" | 125 | 60° to 180° | 1/4 hp | 4.2 | 1/2 NPT Female, 3/4 GHT Male | 1/2 NPT Female, 3/4 GHT Male | 9" | 5 5/8" | 7 3/8" | 0000000 | 0000000 |
Battery-Operated Water-Removal Pumps

Remove water in locations without power with these battery-operated pumps. They attach to an 18-volt battery. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Intake | Discharge | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate @ 5 Ft. of Head, gpm | Max. Ft. of Head, ft. | Temp. Range, °F | Thread Size | Thread Type | Gender | Hose Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
8 | 75 | 35° to 140° | 3/4 | GHT | Male | 3/4 | GHT | Male | 6" | 5 3/4" | 13 1/4" | 0000000 | 0000000 |
Heavy Duty Battery-Operated Water-Removal Pumps

This pump has an impact-resistant aluminum housing and handles larger solids than other battery-operated water-removal pumps. Attach it to a 12-volt battery to remove water in locations without power. Pump is gravity fed and requires an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Discharge | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate @ 5 Ft. of Head, gpm | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Ht. | Each | |
12V DC—With Thermal Overload Protection | |||||||||||||
41 | 20 | 1/4" | 1/4" | 35° to 190° | 1/3 hp | 30 | 1 1/2 | NPT | Female | 9 37/64" | 22 3/64" | 000000 | 000000000 |
Water Removal Pumps with Hose

Use this pump to remove water with small solids up to 1/4" in diameter. It activates when plugged in; add a plug-in switch to control when the pump activates. Install in water that's at least 2" deep. Pump includes a 25-ft. hose with cam-and-groove fittings for quick, secure connections and a storage crate with built-in filtration to protect the pump from debris.
Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Flow Rate | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Connection Coupling Size | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||
Plug with 15" Cord | |||||||||||||||||
41 | 32 | 23 | 11 | 41 gpm | 25 | 1/4" | 7/16" | 35° to 100° | 4/10 hp | 3 | 1 1/4 | Male | 12 3/4" | 11 13/16" | 15 3/4" | 0000000 | 0000000 |
Miniature Water-Removal Pumps with Hose

Complete with a suction strainer and 6 feet of garden hose, this little pump comes ready to clean up small open spaces. It activates when you plug it in. Use with debris-free water.
Maintenance kits (sold separately) include an impeller, an O-ring, and a seal.
Note: The pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Thread Size | Thread Type | Gender | Hose Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug with 6 ft. Cord | |||||||||||||||||||
5.5 | 5 | 4.5 | 4 | 43 | 1/8" | 35° to 75° | 1/12 hp | 2 | 3/4 | GHT | Male | 3/4 | GHT | Male | 6" | 5" | 7" | 0000000 | 0000000 |
Maintenance Kit | 0000000 | Each | 000000 |
Easy-Carry Water-Removal Pumps without Switch

These pumps activate when plugged in. You can add a plug-in switch to control when the pump activates. Use the handle to carry pumps from job to job. Install in debris-free water that’s at least 3/4" deep. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||
23 | 20 | 14 | 9 | 26 | 1/8" | 35° to 120° | 1/6 hp | 2 | 1 | NPT | Female | 8" | 6" | 4.3" | 00000000 | 0000000 |
Plug with 25 ft. Cord | ||||||||||||||||
18 | 17 | 14 | 9 | 26.3 | 1/8" | 35° to 120° | 1/6 hp | 5 | 1 | NPT | Female | 8" | 7" | 5" | 00000000 | 000000 |
Long-Life Easy-Carry Water-Removal Pumps

The switch activates on increasing pressure caused by rising water levels for a long service life. It has a separate cord, so you can replace the switch without replacing the whole pump. Use the handle to carry pumps from job to job. Install in debris-free water that’s at least 3/4" deep. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Turn-On | Turn-Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Plug with 10 ft. Cord | |||||||||||||||||
23 | 19 | 8 | 26 | 1/8" | 9" | 4" | 35° to 120° | 1/6 hp | 2 | 1 | NPT | Female | 8" | 8" | 5" | 00000000 | 0000000 |
Plug with 18 ft. Cord | |||||||||||||||||
23 | 19 | 8 | 26 | 1/8" | 3" | 1 1/2" | 35° to 120° | 1/6 hp | 2 | 1 | NPT | Female | 8" | 8" | 5" | 00000000 | 000000 |
Compact Water-Removal Pumps
Also known as bilge pumps, these remove fresh and salt water from spots where other pumps don’t fit. They have an internal sensor, so they turn on when they detect water and turn off when the water is removed. Pumps are fully submersible. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on.
Pumps for 12 volts DC work with 12-volt batteries.
Pumps for 120 volts AC are for use in debris-free water.

Max. Flow Rate, gpm | Discharge | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Sensor Time Interval | Horsepower | Current, A | For Tube ID | Gender | Dia. | Ht. | Each | |
ABS Plastic Housing | |||||||||||||
Hardwire with 2 ft. Cord | |||||||||||||
5 | 1 | 11 | 1/4" | 30° to 140° | 2.5 min. | Not Rated | 1.6 | 3/4" | Male | 3" | 4" | 0000000 | 000000 |
10 | 3 | 10 | 1/4" | 30° to 140° | 2.5 min. | Not Rated | 3.7 | 1", 1 1/8" | Male | 3" | 5" | 0000000 | 000000 |

Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Sensor Time Interval | Horsepower | Current | Pipe Size | Thread Type | Gender | Dia. | Ht. | Includes | Each | |
ABS Plastic Housing | |||||||||||||||
Plug with 8 ft. Cord | |||||||||||||||
20 | 13 | 18 | 1" | 40° to 140° | 2.5 min. | Not Rated | Not Rated | 1 | NPT | Male | 5" | 8" | Garden Hose Adapter | 0000000 | 0000000 |
Plug with 24 ft. Cord | |||||||||||||||
20 | 13 | 18 | 1" | 40° to 140° | 2.5 min. | Not Rated | Not Rated | 1 | NPT | Male | 5" | 8" | Garden Hose Adapter | 0000000 | 000000 |
Drill-Operated Water-Removal Pumps



Convenient to keep in your toolkit for on-site cleanup, these pumps attach to your drill for small liquid extraction jobs, as well as draining water from clogged sinks and emptying tanks. Pumps are self-priming, which means they create a suction force to draw liquid upward. Do not use with solids.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Intake | Discharge | Shaft | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Feet of Head, ft. | Max. Viscosity, cP | Temp. Range, °F | Hose Size | Thread Type | Gender | Hose Size | Thread Type | Gender | Motor Speed, rpm | Dia. | Lg. | Ht. | Wd. | Lg. | Includes | Each | |
3 3/4 | 90 | 1 | 40° to 110° | 3/4 | GHT | Male | 3/4 | GHT | Male | 1,200 | 1/4" | 3/4" | 3" | 4 1/2" | 3" | __ | 00000000 | 000000 |
3 3/4 | 90 | 1 | 40° to 110° | 3/4 | GHT | Male | 3/4 | GHT | Male | 1,200 | 1/4" | 3/4" | 3" | 4 1/2" | 3" | 30" Slip-On Intake Tube, 34" Discharge Tube with 3/4" Male GHT Connection | 00000000 | 00000 |
Mobile Gasoline-Powered Sewage Water-Removal Pumps

Wheel these pumps to remote areas with no power. They can handle sewage water with thick sludge, silt, and debris up to 2" in diameter. Pumps are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Mount up to 20 feet above your liquid source. All have a pull-start engine. They are not submersible. These pumps cannot be sold to Canada due to import regulations.
Pump with a tank capacity of 1.6 gallons includes an electric starter that operates on a 12-volt battery (sold separately). It cannot be sold outside the United States because of energy efficiency requirements.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Intake (NPT) | Discharge (NPT) | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 30 Ft. of Head | @ 60 Ft. of Head | @ 90 Ft. of Head | @ 100 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To, ft. | Temp. Range, °F | Horsepower | Pipe Size | Gender | Pipe Size | Gender | Ht. | Wd. | Lg. | Cannot Be Sold To | Each | |
1.6 gal. Tank Capacity | ||||||||||||||||||
530 | 335 | 110 | 20 | 103 | 2" | 20 | 40° to 180° | 13 hp | 4 | Female | 4 | Female | 31" | 38" | 45" | Outside United States | 00000000 | 000000000 |
1.7 gal. Tank Capacity | ||||||||||||||||||
460 | 275 | 75 | __ | 100 | 2" | 20 | 40° to 180° | 13 hp | 4 | Male | 4 | Male | 37" | 38" | 45" | Canada | 00000000 | 00000000 |
Portable Oil-Free Electric Vacuum Pumps

These pumps weigh only 16 pounds and have a handle, so they're convenient for on-site sampling, atomizing, and vacuum filtration. They're also for use in pressure applications up to 60 psi. Since they don't require lubrication, there’s no risk of oil contamination. Maximum flow rate is the rate at which air is pumped before a vacuum is created. Flow rate steadily decreases as the pump generates the vacuum. The larger the tank, the longer it will take to form a vacuum. Tube and fitting ID will also affect flow.
Repair kits include filter/muffler components, a gasket, a leaf valve, limiters, and an O-ring.
Pumps | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Intake | Discharge | Overall | Repair Kits | ||||||||||||||
Max. Vacuum, in. of Hg | Max. Flow Rate, cfm | Max. Pressure, psi | Temp. Range, °F | Volume, dBA | Horsepower | Current, A | Tube Connection Type | For Tube ID | Tube Connection Type | For Tube ID | Lg. | Wd. | Ht. | Each | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
NEMA 5-15 Plug | |||||||||||||||||
25.5 | 1.1 | 60 | 35° to 100° | 65 | 1/8 hp | 4.2 | Barbed | 3/8" | Barbed | 3/8" | 7 3/4" | 5 7/8" | 11" | 0000000 | 0000000 | 0000000 | 000000 |
Portable Battery-Operated Drum Pumps for Diesel Fuel

For on-site diesel fuel dispensing at construction sites, on boats, and in other environments without electrical hookups, attach these portable pumps to any 12-volt battery.
Temp. Range, °F | Intake | Discharge | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | Includes | Hose Connection Type | For Hose ID | Hose Connection Type | For Hose ID | Features | Each | |
12V DC, Single Phase | |||||||||||||||
13 | 21 | 5.3 | 25° | 100° | Not Rated | 18 | 6 | 6 1/2-ft. Battery Cable with Clamps | Barbed | 3/4" | Barbed | 3/4" | Bypass Relief Valve | 00000000 | 0000000 |
Portable Battery-Operated Drum Pumps with Nozzle for Diesel Fuel

A nozzle and hose allow you to dispense directly into your container. For on-site diesel fuel dispensing at construction sites, on boats, and in other environments without electrical hookups, attach these portable pumps to any 12-volt battery.
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | Includes | Hose Connection Type | For Hose ID | ID | Lg., ft. | Features | Each | |
12V DC, Single Phase | |||||||||||||||
13 | 14 | 5.3 | 25° | 100° | Not Rated | 22 | 6 | 6 1/2-ft. Battery Cable with Clamps | Barbed | 3/4" | 3/4" | 13 | Bypass Relief Valve | 00000000 | 0000000 |
Air Pumps




Pump with vehicle plug connects to a 12-volt vehicle outlet. Pump with spring clamps connects directly to a 12-volt vehicle battery.
Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Max. Pressure, psi | For Valve Type | Cord Lg. | Lg. | Wd. | Ht. | Air Hose Lg. | Includes | Housing Material | Each | |
Manual | ||||||||||
100 | Schrader | __ | 7" | 3" | 20" | 12" | __ | Steel | 0000000 | 000000 |
200 | Schrader | __ | 9" | 4" | 27" | 39" | Pressure Gauge | Steel | 0000000 | 00000 |
Vehicle Battery Powered with Vehicle Plug | ||||||||||
12V DC | ||||||||||
60 | Schrader | 9 ft. | 9 1/4" | 3" | 5 1/2" | 3ft. | Pressure Gauge | Aluminum | 0000000 | 00000 |
Vehicle Battery Powered with Spring Clamps | ||||||||||
12V DC | ||||||||||
120 | Schrader | 9 ft. | 10" | 3" | 5 1/2" | 12ft. | Pressure Gauge | Aluminum | 0000000 | 00000 |
Portable Air Compressors



Compressors turn on when the tank falls to the actuation pressure and they turn off when the tank reaches the maximum pressure.
Compressors that cannot be sold to the listed areas are restricted due to product regulations.
Pressure, psi | Overall | Outlet | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. | Actuation | Max. Flow Rate @ psi | hp | Full Load Current, A | Tank Cap., gal. | Volume, dBA | Lg. | Wd. | Ht. | Pipe Size | Thread Type | Gender | Compressor Oil Type | Weight, lbs. | Cannot Be Sold To | Each | |
Single Tank | |||||||||||||||||
Single Phase, 120V AC | |||||||||||||||||
150 | 120 | 3 cfm @ 100 3 cfm @ 50 3 cfm @ 75 3 cfm @ 90 4 cfm @ 25 | 0.45 | 10 | 6 | 82 | 16" | 16" | 18" | 1/4 | NPT | Female | __ | 34 | __ | 0000000 | 0000000 |
Single Tank with Solid Wheels | |||||||||||||||||
Single Phase, 120V AC | |||||||||||||||||
140 | 110 | 6.5 cfm @ 90 | 3 | 13.8 | 5.2 | 84 | 19 1/2" | 19" | 29" | 1/4 | NPT | Female | 30W | 88 | Outside United States | 0000000 | 000000 |
Double Tank with Flat-Free Wheel | |||||||||||||||||
Single Phase, 120V AC | |||||||||||||||||
135 | 95 | 4.9 cfm @ 135 5.7 cfm @ 90 | 2 | 15 | 8 | 78 | 43" | 18" | 25" | 3/8 | NPT | Female | 10W-40W | 175 | __ | 0000000 | 00000000 |
Single Phase, 230V AC | |||||||||||||||||
135 | 95 | 10.3 cfm @ 135 11.3 cfm @ 90 | 3 | 15 | 8 | 78 | 43" | 18" | 25" | 3/8 | NPT | Female | 10W-40W | 175 | __ | 0000000 | 00000000 |
Air Compressors with DC Motor

Get compressed air from a DC power source—these compressors can run on a 12-volt vehicle battery (not included) for use on trucks and heavy equipment, or a DC generator. Use them to inflate tires, clean filters, and operate light-duty tools, such as nailers, hammers, and small impact wrenches. For best results with a vehicle battery, use a deep-cycle, large-cell battery rated for continuous use.
Connector assemblies come with a three-foot hose and a connector that can be fixed to a panel or frame for operating compressors installed in difficult-to-reach locations, such as under a vehicle.
Compressor | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Outlet (Female) | Overall | |||||||||||
Max. Pressure, psi | Max. Flow Rate @ psi | hp | Full Load Current, A | Vol., dBA | Pipe Size | Thread Type | Lubricant Required | Lg. | Wd. | Ht. | Each | |
12V DC | ||||||||||||
200 | 7.9 cfm @ 200 8 cfm @ 100 9 cfm @ 75 | 2 1/5 | 180 | 83 | 3/8 | NPT | Yes | 21" | 7" | 11" | 0000000 | 000000000 |
Mobile Fuel Dispensers



Style C have a filter that strains out dirt and water, a valve to switch between filling and draining, and a flame arrester to protect against outside ignition. Rotate the hand pump to dispense fuel. The pump hose has a grounding strap.
Wheel | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | For Fuel Type | Cap., gal. | Flow Rate, gpm | Lg. | Wd. | Ht. | Fill Opening Dia. | Nozzle OD | Hose Lg., ft. | Color | Material | Material | Type | Includes | Specifications Met | UN Shipping Standard | Each | |
Gravity Fed | ||||||||||||||||||
A | Gasoline | 14 | 2 | 11" | 17" | 34" | 1 3/4" | 1" | 10 | Red | Plastic | Plastic | Solid | __ | UN3H1/Y/130 | __ | 00000000 | 0000000 |
B | Gasoline | 25 | 2 | 17" | 22" | 43" | 2" | 3/4" | 8 | Red | Plastic | Rubber | Pneumatic | __ | UN3H1W/Y1.2/110 | UN3H1 | 00000000 | 000000 |
B | Diesel | 25 | 2 | 17" | 22" | 43" | 2" | 3/4" | 8 | Yellow | Plastic | Rubber | Pneumatic | __ | UN3H1W/Y1.2/110 | UN3H1 | 00000000 | 000000 |
Hand Pump | ||||||||||||||||||
C | Gasoline | 34 | 4 | 48" | 17" | 39" | 1 1/2" | 3/4" | 7 | Red | Powder-Coated Steel | Rubber | Solid | 8-ft. Grounding Strap with Clamp | FM Approved | __ | 0000000 | 00000000 |
C | Diesel | 34 | 4 | 48" | 17" | 39" | 1 1/2" | 3/4" | 7 | Green | Powder-Coated Steel | Rubber | Solid | 8-ft. Grounding Strap with Clamp | FM Approved | __ | 0000000 | 00000000 |