Filter by
System of Measurement
Voltage
Current @ Temperature
Wire Construction
Wire Material
Flexibility
Certification
Shielding
Outer Jacket Material
Maximum Temperature
Environment
Wire Finish
Finish
RoHS
Wire and Cable Use
DFARS Specialty Metals
Export Control Classification Number (ECCN)
REACH
About Wire and Cable
More
High-Voltage Cable

- Use For: Power Supply, Outdoors
- Flexible
- Temperature Range: -40° to 190° F
- Insulation: EPDM Rubber
Often used in mining equipment, submersible pumps, and drilling rigs, this cable withstands 2,000 volts AC/DC. The EPDM insulation resists abrasion, so it can be pulled over rough surfaces without damaging the wires inside.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | |
Stranded Wire | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
2,000V AC/2,000V DC | ||||||||||||
8 | 2 | 8/2 | 74 A @ 86° F | 0.78" | Black | Black, White | UL Listed, CSA Certified | 000000 | ||||
8 | 3 | 8/3 | 74 A @ 86° F | 0.92" | Black | Black, Green, White | UL Listed, CSA Certified | 000000 | ||||
6 | 2 | 6/2 | 99 A @ 86° F | 0.91" | Black | Black, White | UL Listed, CSA Certified | 000000 | ||||
6 | 3 | 6/3 | 99 A @ 86° F | 0.99" | Black | Black, Green, White | UL Listed, CSA Certified | 000000 | ||||
4 | 3 | 4/3 | 130 A @ 86° F | 1.13" | Black | Black, Green, White | UL Listed, CSA Certified | 000000 | ||||
2 | 3 | 2/3 | 174 A @ 86° F | 1.28" | Black | Black, Green, White | UL Listed, CSA Certified | 000000 |
UV-Resistant Wire

- Use for outdoors, buildings, solar equipment, power supply
- Flexible
- Temperature Range: -40° to 190° F
- Insulation: Cross-Linked Polyethylene (XLPE)
Also known as photovoltaic (PV) wire, this wire won’t deteriorate from UV light when used outdoors. Often used in solar panels, the cross-linked polyethylene (XPLE) insulation won’t break down from prolonged exposure to high temperatures. The insulation also resists chemicals. An RHW-2 industry designation means this wire withstands underground and wet locations.
2,000V AC/2,000V DC
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Choose an Outer Insulation Color | 10 ft. | 25 ft. | 50 ft. | 100 ft. | |
Stranded Wire | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
12 | 19/25 | 40 A @ 86° F | 0.21" | PV, RHW-2 | UL Listed, C-UL Listed, UL 2556 VW-1 | 000000 | |||||
10 | 19/21 | 40 A @ 86° F | 0.24" | PV, RHW-2 | UL Listed, C-UL Listed, UL 2556 VW-1 | 000000 | |||||
8 | 19/21 | 55 A @ 86° F | 0.3" | PV, RHW-2 | UL Listed, C-UL Listed, UL 2556 VW-1 | 000000 |