About AC to AC Voltage Transformers
For single-phase equipment, use this formula to find power output: VA = Volts × Amps
For three-phase equipment, use this formula to find power output: VA = Volts × Amps × 1.73
More
Touch-Safe High-Inrush Panel-Mount AC to AC Transformers
Prevent accidental contact with live electrical connections—the screw terminals are covered or recessed. These transformers can handle momentary high-inrush current associated with contactors, solenoids, and relays. Also known as control transformers.
Isolated coils protect equipment from input voltage spikes.
Voltage | |||||||||
---|---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Ht. | Wd. | Dp. | Features | Specifications Met | Each | |
Single Phase—Screw Terminals Input and Output | |||||||||
Step Down Voltage | |||||||||
240V AC/480V AC | 120V AC | 50 | 2.8" | 3" | 3.3" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 75 | 2.8" | 3" | 3.8" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 00000 |
240V AC/480V AC | 120V AC | 100 | 3.1" | 3.4" | 3.8" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 250 | 4" | 4 1/2" | 4.6" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 350 | 4" | 4 1/2" | 5.3" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 500 | 4.7" | 5.3" | 5.8" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 750 | 4.7" | 5.3" | 7" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 1,000 | 5.7" | 7" | 6.6" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 1,500 | 5.7" | 7" | 7.6" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 2,000 | 6" | 6.8" | 8.1" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
Harsh Environment High-Inrush Panel-Mount AC to AC Transformers
Sealed coils protect against dust, dirt, oil, and moisture. These transformers can handle momentary high-inrush current associated with contactors, solenoids, and relays. Also known as control transformers. Choose a transformer with multiple output voltages to simultaneously power multiple devices that require different output voltages.
Input and output fuse blocks are built-in and top-mounted to save panel space and allow quick installation.
Voltage | For Fuse | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Ht. | Wd. | Dp. | Type | O'all Dia. | Specifications Met | Each | |
Single Phase—Screw Terminals Input and Output | ||||||||||
Step Down Voltage—Input and Output Fuse Block | ||||||||||
240V AC/480V AC | 120V AC | 50 | 4" | 3" | 3.8" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 75 | 4" | 3" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 00000 |
240V AC/480V AC | 120V AC | 100 | 4.3" | 3.4" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 00000 |
240V AC/480V AC | 120V AC | 150 | 4.7" | 3.8" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 250 | 5.3" | 4 1/2" | 4.4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 500 | 6" | 5.3" | 6.1" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
High-Inrush Panel-Mount AC to AC Transformers
These transformers can handle momentary high-inrush current associated with contactors, solenoids, and relays. Also known as control transformers.
Input and output fuse blocks are built-in and top-mounted to save panel space and allow quick installation.
Voltage | ||||||||
---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Ht. | Wd. | Dp. | Specifications Met | Each | |
Step Down Voltage | ||||||||
240V AC/480V AC | 120V AC | 50 | 2.6" | 3" | 3.1" | UL Listed, CSA Certified | 0000000 | 0000000 |
240V AC/480V AC | 120V AC | 100 | 2.9" | 3.4" | 3.3" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 150 | 3.2" | 3.8" | 3.6" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 250 | 3.2" | 3.8" | 5.3" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 350 | 3.8" | 4 1/2" | 5.1" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 500 | 3.8" | 4 1/2" | 5 1/2" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 750 | 4 1/2" | 5.3" | 5.6" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 1,000 | 4 1/2" | 5.3" | 6.3" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 1,500 | 6.2" | 7.1" | 5.9" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 2,000 | 5.4" | 7" | 8.4" | UL Listed, C-UL Listed | 0000000 | 000000 |
Voltage | For Fuse | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Ht. | Wd. | Dp. | Type | O'all Dia. | Specifications Met | Each | |
Step Down Voltage | ||||||||||
240V AC/480V AC | 120V AC | 50 | 4" | 3" | 3.1" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 0000000 |
240V AC/480V AC | 120V AC | 100 | 4.2" | 3.4" | 3.3" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 150 | 4 1/2" | 3.8" | 3.6" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 250 | 4 1/2" | 3.8" | 5.3" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 350 | 5.1" | 4 1/2" | 5.1" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 500 | 5.1" | 4 1/2" | 5 1/2" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 750 | 5.8" | 5.3" | 5.6" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 1,000 | 5.8" | 5.3" | 6.3" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 1,500 | 7.7" | 6.8" | 8.1" | UL Class CC Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 2,000 | 7.7" | 6.8" | 7.8" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 000000 |
Enclosed Step-Up/Step-Down AC to AC Transformers
Improve the efficiency of your equipment—wire these transformers to step your input voltage up or down by as much as 20%. Choose an input/output voltage combination that comes closest to matching your application, then choose the power output (in VA) of the equipment you want to operate. You probably won’t find the exact value you need; choose the next highest rating.
Note: Transfomers are labeled with a prewired power output and pre-wired primary and secondary voltages. Single phase transformers are labeled as 120/240V AC primary voltage and 12/24V AC secondary voltage.Three phase transformers are labeled as 120/240V AC primary voltage and 16/32V AC secondary voltage. All possible input voltage and output voltage wiring combinations are listed.
Prewired | ||||||||
---|---|---|---|---|---|---|---|---|
Input/Output Voltage— Power Output | Power Output Label, VA | Primary Voltage Label | Secondary Voltage Label | Ht. | Wd. | Dp. | Each | |
Single Phase—Wire Leads Input and Output | ||||||||
Step Up/Step Down Voltage | ||||||||
100V AC/120V AC—250VA 110V AC/120V AC—500VA 125V AC/113V AC—520VA 132V AC/120V AC—540VA 189V AC/208V AC—430VA 208V AC/230V AC—480VA 220V AC/242V AC—500VA 230V AC/208V AC—470VA 245V AC/222V AC—500VA 252V AC/240V AC—1,020VA | 50 | 120V AC/240V AC | 12V AC/24V AC | 6.4" | 3.1" | 3.1" | 00000000 | 0000000 |
100V AC/120V AC—500VA 110V AC/120V AC—1,010VA 125V AC/113V AC—1,040VA 132V AC/120V AC—1,080VA 189V AC/208V AC—870VA 208V AC/230V AC—960VA 220V AC/242V AC—1,010VA 230V AC/208V AC—950VA 245V AC/222V AC—1,000VA 252V AC/240V AC—2,040VA | 100 | 120V AC/240V AC | 12V AC/24V AC | 7.2" | 3.9" | 3.7" | 00000000 | 000000 |
100V AC/120V AC—750VA 110V AC/120V AC—1,510VA 125V AC/113V AC—1,560VA 132V AC/120V AC—1,620VA 189V AC/208V AC—1,300VA 208V AC/230V AC—1,430VA 220V AC/242V AC—1,510VA 230V AC/208V AC—1,420VA 245V AC/222V AC—1,500VA 252V AC/240V AC—3,000VA | 150 | 120V AC/240V AC | 12V AC/24V AC | 7.2" | 3.9" | 3.7" | 00000000 | 000000 |
100V AC/120V AC—1,250VA 110V AC/120V AC—2,500VA 125V AC/113V AC—2,600VA 132V AC/120V AC—2,750VA 189V AC/208V AC—2,160VA 208V AC/230V AC—2,390VA 220V AC/242V AC—2,520VA 230V AC/208V AC—2,370VA 245V AC/222V AC—2,500VA 252V AC/240V AC—5,100VA | 250 | 120V AC/240V AC | 12V AC/24V AC | 8.7" | 4.1" | 3.9" | 00000000 | 000000 |
100V AC/120V AC—2,500VA 110V AC/120V AC—5,000VA 125V AC/113V AC—5,200VA 132V AC/120V AC—5,400VA 189V AC/208V AC—4,330VA 208V AC/230V AC—4,790VA 220V AC/242V AC—5,040VA 230V AC/208V AC—4,470VA 245V AC/222V AC—5,000VA 252V AC/240V AC—10,200VA | 500 | 120V AC/240V AC | 12V AC/24V AC | 9.1" | 4.4" | 4.2" | 00000000 | 000000 |
100V AC/120V AC—3,750VA 110V AC/120V AC—7,560VA 125V AC/113V AC—7,800VA 132V AC/120V AC—8,150VA 189V AC/208V AC—6,500VA 208V AC/230V AC—7,190VA 220V AC/242V AC—7,560VA 230V AC/208V AC—7,100VA 245V AC/222V AC—7,500VA 252V AC/240V AC—15,300VA | 750 | 120V AC/240V AC | 12V AC/24V AC | 9.7" | 4.8" | 4 1/2" | 00000000 | 000000 |
100V AC/120V AC—5,000VA 110V AC/120V AC—10,000VA 125V AC/113V AC—10,400VA 132V AC/120V AC—10,800VA 189V AC/208V AC—8,660VA 208V AC/230V AC—9,580VA 220V AC/242V AC—10,000VA 230V AC/208V AC—9,500VA 245V AC/222V AC—10,000VA 252V AC/240V AC—20,400VA | 1,000 | 120V AC/240V AC | 12V AC/24V AC | 10 1/2" | 5 1/2" | 5.1" | 00000000 | 000000 |
Enclosed Isolating AC to AC Transformers
These transformers have isolated primary and secondary coils to protect your sensitive equipment from input voltage spikes.
Three phase transformers have Wye wiring for output voltage.
Sealed coils and cores prevent corrosion and insulation damage.
When wired as constant voltage transformers, they filter out voltage spikes and electrical noise.
Transformers that cannot be sold to California are restricted by local energy efficiency regulations.
Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Ht. | Wd. | Dp. | Features | Environment | Environmental Rating | Specifications Met | Each | |
Step Up/Step Down/Constant Voltage | |||||||||||
120V AC, 240V AC | 120V AC, 240V AC | 1,000 | 10 1/2" | 5 1/2" | 5.1" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, C-UL Listed | 0000000 | 0000000 |
120V AC, 240V AC | 120V AC, 240V AC | 2,000 | 13" | 5 1/2" | 5.1" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC, 240V AC | 120V AC, 240V AC | 3,000 | 11 1/2" | 10.3" | 7.1" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC, 240V AC | 120V AC, 240V AC | 5,000 | 14.4" | 10.3" | 7.1" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, C-UL Listed | 0000000 | 00000000 |
Step Down/Constant Voltage | |||||||||||
240V AC, 480V AC | 120V AC, 240V AC | 750 | 11.3" | 5.3" | 6 1/2" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC, 480V AC | 120V AC, 240V AC | 1,000 | 11.3" | 5.3" | 6 1/2" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC, 480V AC | 120V AC, 240V AC | 1,500 | 13.3" | 6.3" | 7.8" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC, 480V AC | 120V AC, 240V AC | 3,000 | 13.3" | 6.3" | 7.8" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC, 480V AC | 120V AC, 240V AC | 5,000 | 15" | 10.2" | 10.6" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC, 480V AC | 120V AC, 240V AC | 7,500 | 15.2" | 13 1/2" | 10.8" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, CSA Certified | 0000000 | 00000000 |
240V AC, 480V AC | 120V AC, 240V AC | 10,000 | 15.2" | 13 1/2" | 10.8" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, CSA Certified | 0000000 | 00000000 |
240V AC, 480V AC | 120V AC, 240V AC | 15,000 | 16.9" | 14.1" | 11.6" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, CSA Certified | 0000000 | 00000000 |
240V AC, 480V AC | 120V AC, 240V AC | 25,000 | 18.4" | 16.1" | 13.3" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, CSA Certified | 0000000 | 00000000 |
Voltage | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Ht. | Wd. | Dp. | Features | Environment | Environmental Rating | Specifications Met | Each | |
Step Down Voltage | |||||||||||
480V AC | 120V AC, 208V AC | 3,000 | 10.4" | 12.4" | 7 1/2" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, CSA Certified | 0000000 | 000000000 |
480V AC | 120V AC, 208V AC | 6,000 | 11.8" | 14.2" | 8.8" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, CSA Certified | 0000000 | 00000000 |
480V AC | 120V AC, 208V AC | 9,000 | 14" | 17.8" | 11 1/2" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, CSA Certified | 0000000 | 00000000 |
480V AC | 120V AC, 208V AC | 15,000 | 18.9" | 20.3" | 9" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, CSA Certified | 0000000 | 00000000 |
Voltage | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Ht. | Wd. | Dp. | Features | Environment | Environmental Rating | Specifications Met | Cannot Be Sold To | Each | |
Step Down Voltage | ||||||||||||
480V AC | 120V AC, 208V AC | 30,000 | 25 1/2" | 24.4" | 19.4" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, CSA Certified | CA | 0000000 | 000000000 |
480V AC | 120V AC, 208V AC | 45,000 | 25 1/2" | 24.4" | 19.4" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, CSA Certified | CA | 0000000 | 00000000 |
480V AC | 120V AC, 208V AC | 75,000 | 29.4" | 28.2" | 22.4" | Isolated Coils, Sealed Coils, Sealed Cores | Outdoor | NEMA 3R | UL Listed, CSA Certified | CA | 0000000 | 00000000 |
Enclosed Voltage-Stabilizing AC to AC Transformers
Protect sensitive equipment from electromagnetic interference and maintain power during three-millisecond power dips. These transformers also isolate output and input voltage (output regulation is ±3% with input voltage fluctuations from +10% to -20%). When wired for constant voltage, transformers filter out voltage spikes and electrical noise.
Voltage | ||||||||
---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Ht. | Wd. | Dp. | Specifications Met | Each | |
Single Phase—Screw Terminals Input and Output | ||||||||
Step Up/Step Down/Constant Voltage | ||||||||
120V AC, 208V AC, 240V AC, 480V AC | 120V AC, 208V AC, 240V AC | 140 | 4.4" | 6" | 8 1/2" | UL Listed, CSA Certified | 0000000 | 0000000 |
120V AC, 208V AC, 240V AC, 480V AC | 120V AC, 208V AC, 240V AC | 250 | 4.4" | 6" | 9.7" | UL Listed, CSA Certified | 0000000 | 000000 |
120V AC, 208V AC, 240V AC, 480V AC | 120V AC, 208V AC, 240V AC | 500 | 6 1/2" | 6.3" | 12.3" | UL Listed, CSA Certified | 0000000 | 00000000 |
120V AC, 208V AC, 240V AC, 480V AC | 120V AC, 208V AC, 240V AC | 750 | 6 1/2" | 6.3" | 13.3" | UL Listed, CSA Certified | 0000000 | 00000000 |
120V AC, 208V AC, 240V AC, 480V AC | 120V AC, 208V AC, 240V AC | 1,000 | 6 1/2" | 6.3" | 14.2" | UL Listed, CSA Certified | 0000000 | 00000000 |
120V AC, 208V AC, 240V AC, 480V AC | 120V AC, 208V AC, 240V AC | 1,500 | 9.9" | 9.4" | 17.6" | UL Listed, CSA Certified | 0000000 | 00000000 |
120V AC, 208V AC, 240V AC, 480V AC | 120V AC, 208V AC, 240V AC | 3,000 | 9.9" | 9.4" | 19.9" | UL Listed, CSA Certified | 0000000 | 00000000 |
Enclosed Step-Down AC to AC Transformers
Also known as auto transformers, these decrease incoming voltage to meet the needs of your application. They have sealed coils and cores to prevent corrosion and insulation damage.
When wired for constant voltage, transformers filter out voltage spikes and electrical noise.
Voltage | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Ht. | Wd. | Dp. | Environment | Environmental Rating | Specifications Met | Each | |
Step Down/Constant Voltage | ||||||||||
240V AC | 120V AC, 240V AC | 1,000 | 9.1" | 4.4" | 4.2" | Outdoor | NEMA 3R | UL Listed, CSA Certified | 0000000 | 0000000 |
240V AC | 120V AC, 240V AC | 1,500 | 9.7" | 4 1/2" | 4 1/2" | Outdoor | NEMA 3R | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC | 120V AC, 240V AC | 2,000 | 10 1/2" | 5 1/2" | 5.1" | Outdoor | NEMA 3R | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC | 120V AC, 240V AC | 3,000 | 11.6" | 5 1/2" | 5.1" | Outdoor | NEMA 3R | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC | 120V AC, 240V AC | 5,000 | 13" | 5 1/2" | 5.1" | Outdoor | NEMA 3R | UL Listed, CSA Certified | 0000000 | 00000000 |
Backup Power Supplies
Transfer power to a built-in battery during brownouts and blackouts with only a momentary loss of power during transfer. With a USB connection and cord, you can save data and safely shut down an unattended computer during an outage with these supplies. They also protect against line noise and power surges. Choose a power output equal to or greater than the power your equipment requires. Determine your volt-amps requirement by multiplying the amp draw of your equipment by 120V AC. Power supplies cannot be sold to the regions listed due to local energy efficiency requirements.
Output | Run Time, min. | NEMA Sockets | Ethernet Sockets | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power | Current, A | Half Load | Full Load | Input Plug Type (NEMA Style) | Output Connection NEMA Style | No. of Outlets | Output USB Connection Type | No. of Outlets | Output Ethernet Connection Type | No. of Outlets | Ht. | Wd. | Dp. | Cannot Be Sold To | Each | |
700VA/350W | 5.8 | 10 | 3 | Three Prong (5-15) | 5-15 | 6 | A | 1 | RJ45 | 1 | 9.8" | 4.8" | 13.6" | CO, VT, WA | 0000000 | 0000000 |
Low-Profile Power Conditioning Backup Power Supplies
Smaller in height than standard backup power supplies, these fit in tight spaces. They transfer power to a built-in battery during brownouts and blackouts with only a momentary loss of power during transfer. They also protect against line noise and power surges. All have a USB connection and cord so you can save data and safely shut down an unattended computer during outage. Choose a power output equal to or greater than the power your equipment requires. Determine your volt-amps requirement by multiplying the amp draw of your equipment by 120V AC. Power supplies cannot be sold to the regions listed due to local energy efficiency requirements.
Output | Run Time, min. | NEMA Sockets | USB Sockets | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power | Current, A | Half Load | Full Load | Input Plug Type (NEMA Style) | Output Connection NEMA Style | No. of Outlets | No. of Outlets with Battery Backup | Output USB Connection Type | No. of Outlets | Ht. | Wd. | Dp. | Cannot Be Sold To | Each | |
350VA/210W | 2.9 | 8 | 2 | Three Prong (5-15) | 5-15 | 6 | 3 | B | 1 | 4.1" | 4.3" | 7.3" | __ | 0000000 | 000000 |
550VA/300W | 4.6 | 5 | 1.2 | Three Prong (5-15) | 5-15 | 10 | 5 | A; B | 2 | 4.1" | 4.3" | 7.3" | __ | 0000000 | 000000 |
750VA/450W | 6.3 | 11 | 2.5 | Three Prong (5-15) | 5-15 | 12 | 6 | A | 1 | 3.1" | 12.2" | 6.9" | CO, VT, WA | 0000000 | 000000 |
Power Conditioning Backup Power Supplies
Protect sensitive equipment—these conditioners raise or lower current to keep it at a stable level during dips and surges. There is no battery transfer time during a power dip. During brownouts and blackouts, they transfer power to a built-in battery with only a momentary loss of power during transfer. Power supplies also protect against line noise and power surges. They have a USB connection and cord so you can save data and safely shut down an unattended computer during outage.
Choose a power output equal to or greater than the power your equipment requires. Determine your volt-amps requirement by multiplying the amp draw of your equipment by 120V AC.
Output | Run Time, min. | NEMA Sockets | USB Sockets | Ethernet Sockets | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power | Current, A | Half Load | Full Load | Input Plug Type (NEMA Style) | Output Connection NEMA Style | No. of Outlets | No. of Outlets with Battery Backup | Output USB Connection Type | No. of Outlets | Output Ethernet Connection Type | No. of Outlets | Ht. | Wd. | Dp. | Each | |
750VA/460W | 6.3 | 11 | 3.6 | Three Prong (5-15) | 5-15 | 12 | 6 | B | 1 | RJ45 | 2 | 4.1" | 7.5" | 12" | 00000000 | 0000000 |
1,440VA/900W | 12 | 12 | 3 | Three Prong (5-15) | 5-15 | 10 | 5 | A | 2 | __ | __ | 11" | 3.9" | 16.1" | 00000000 | 000000 |
Uninterruptible Power Supplies
Protect sensitive and critical electronic equipment—these uninterruptible power supplies (UPS) do not suffer a loss of power when switching from your power source to the UPS during an outage. They also protect against frequency variation and waveform distortion. All have USB and DB9 connections with cords so you can save data and safely shut down an unattended computer during outages. Choose a power output that is equal to or greater than the power your equipment requires.
Output | Run Time, min. | No. of Outlets | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input Voltage Range | Voltage (Accuracy) | Power | Current, A | Half Load | Full Load | Input Plug Type (NEMA Style) | 5-15 Sockets | 5-20 Sockets | L5-20 Sockets | Ht. | Wd. | Dp. | Specifications Met | Each | |
100V AC-127V AC | 120V AC (±2%) | 1,000VA/900W | 9.1 | 14 | 4.8 | Three Prong (5-15) | 6 | __ | __ | 3.5" | 17.5" | 12.5" | UL 1778 | 00000000 | 000000000 |
100V AC-127V AC | 120V AC (±2%) | 1,500VA/1,350W | 12.5 | 14 | 4.2 | Three Prong (5-15) | 6 | __ | __ | 3.5" | 17.5" | 18.5" | UL 1778 | 00000000 | 00000000 |
100V AC-127V AC | 120V AC (±2%) | 2,200VA/1,800W | 15 | 12 | 4 | Three Prong (5-20) | __ | 6 | 1 | 3.5" | 17.5" | 19" | UL 1778 | 00000000 | 00000000 |
Rack-Mount Power Supply Conditioners
Install these conditioners in standard 19" wide electronics racks. They raise or lower current to keep it at a stable level during dips and surges. Choose a power output that is equal to or greater than the power your equipment requires. Determine your required volt-amps by multiplying the amp draw of your equipment by 120V AC.
Voltage | Output | Input Connection | Output Connection | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input | Output (Accuracy) | Power | Current, A | Plug Type | NEMA Style | Cord Lg., ft. | Type | NEMA Style | No. of Outlets | Ht. | Wd. | Dp. | Each | |
89V AC-147V AC | 120V AC (±9%) | 2,400VA/2,400W | 20 | Three Prong | 5-15 | 12 | Socket | 5-15 | 14 | 5.3" | 19" | 5" | 0000000 | 0000000 |
Power Supply Conditioners
These units raise or lower current to keep it at a stable level during dips and surges. Choose a power output that is equal to or greater than the power your equipment requires. Determine your required volt-amps by multiplying the amp draw of your equipment by 120V AC.
Voltage | Output | Input Connection | Output Connection | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input | Output (Accuracy) | Power | Current, A | Plug Type | NEMA Style | Cord Lg., ft. | Type | NEMA Style (No. of Outlets) | Ht. | Wd. | Dp. | Specifications Met | Each | |
89V AC-147V AC | 120V AC (±9%) | 600VA/600W | 5 | Three Prong | 5-15 | 6 | Socket | 5-15 (6) | 5.5" | 4.8" | 4.8" | UL Listed, C-UL Listed | 0000000 | 0000000 |
89V AC-147V AC | 120V AC (±9%) | 1,200VA/1,200W | 10 | Three Prong | 5-15 | 6 | Socket | 5-15 (4) | 7.3" | 6" | 7" | UL Listed, C-UL Listed | 0000000 | 000000 |
89V AC-147V AC | 120V AC (±9%) | 1,800VA/1,500W | 15 | Three Prong | 5-15 | 6 | Socket | 5-15 (6) | 6.8" | 5.8" | 6.8" | UL Listed, C-UL Listed | 0000000 | 000000 |
89V AC-147V AC | 120V AC (±9%) | 2,400VA/2,400W | 20 | Three Prong | 5-15 | 6 | Socket | 5-15 (4), 5-20 (2) | 6.8" | 5.8" | 6.8" | __ | 0000000 | 000000 |
96V AC-132V AC | 120V AC (±5%) | 420VA/300W | 3.5 | Three Prong | 5-15 | 6 | Socket | 5-15 (4) | 5.5" | 6.8" | 9.5" | UL Listed, CSA Certified | 0000000 | 000000 |
96V AC-132V AC | 120V AC (±5%) | 650VA/450W | 5.4 | Three Prong | 5-15 | 6 | Socket | 5-15 (6) | 6.5" | 8.5" | 11.3" | UL Listed, CSA Certified | 0000000 | 000000 |
DC to AC Transformers for Sensitive Electronic Loads
These transformers produce AC output that most closely resembles clean, stable AC-generated power. Also known as inverters and converters, they prevent damage from overloads, short circuits, and overheating.
Voltage | Output | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Input | Output | Power, W | Current, A | Input Plug Type | Output Socket Type (NEMA Style) | Ht. | Wd. | Dp. | Each | |
Step Up Voltage | |||||||||||
1 | 12V DC | 120V AC | 125 | 1.1 | Vehicle | Three Slot (5-15) | 2.2" | 4.9" | 7.9" | 00000000 | 0000000 |
Voltage | Output | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Input | Output | Power, W | Current, A | Output Socket Type (NEMA Style) | Ht. | Wd. | Dp. | Each | |
Step Up Voltage | ||||||||||
1 | 24V DC | 120V AC | 125 | 1.1 | Three Slot (5-15) | 2.2" | 4.9" | 7.9" | 00000000 | 0000000 |
DC to AC Transformers for Motor Loads
Provide AC power to devices that temporarily draw high output, such as motors. These transformers are designed to withstand starting surges up to twice the power output rating. Also known as inverters and converters, they prevent damage from overloads.
Voltage | Output | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Number of Outlets | Input | Output | Power, W | Current, A | Output Socket Type (NEMA Style) | Ht. | Wd. | Dp. | Each | |
Step Up Voltage | ||||||||||
2 | 12V DC | 120V AC | 1,250 | 10.4 | Three Slot (5-15) | 7" | 8.8" | 9" | 0000000 | 0000000 |
DC to AC Transformers
Use DC voltage to power devices that run on AC voltage. Also known as inverters and converters, they prevent damage from overloads.
Voltage | Output | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Input | Output | Power, W | Current, A | Output Socket Type (NEMA Style) | Ht. | Wd. | Dp. | Each | |
Single Phase—Screw Terminals Input and Socket Output | ||||||||||
Step Up Voltage | ||||||||||
3 | 12V DC | 120V AC | 700 | 5.8 | Three Slot (5-15) | 2.8" | 5" | 8.2" | 0000000 | 0000000 |
4 | 12V DC | 120V AC | 1,000 | 8.3 | Three Slot (5-15) | 4.3" | 6" | 13" | 0000000 | 000000 |
4 | 12V DC | 120V AC | 1,800 | 15 | Three Slot (5-15) | 4" | 6" | 15" | 0000000 | 000000 |