McMaster-Carr logo
    Filter by
    System of Measurement
    Minimum Pressure
    Display Type
    Graduations
    Connects To
    Outlet Pressure
    Inlet Pipe Size
    Industrial Info Compare
    Maximum Pressure Differential
    Pressure Numeric Increments
    Dial Type
    Maximum Pressure Regulation
    Thread Type
    Industrial Info Compare
    Outlet Pipe Size
    Industrial Info Compare
    Inlet Thread Type
    Industrial Info Compare
    Dial Diameter
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    29 Products
    About Pressure Gauges
    industrial info icon

    Find a gauge with the right connection material and dial type—many with traceable calibration certificates.

    Low-Pressure Differential Gauges with Color Indicator

    A band of green, yellow, and red provides a clear indication of changes in differential pressure. Gauges are commonly used to indicate clogged filters.
    Glass-Filled Nylon Case with Anodized Aluminum Connections (Pounds per Square Inch)
    Image of Product. Front orientation. Differential Pressure Gauges. Low-Pressure Differential Gauges with Color Indicator.
    Pressure
    Range, psi
    Green
    Band
    Yellow
    Band
    Red Band
    Max. Pressure,
    psi
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    Ht.
    Wd.
    Dp.
    Case
    Color
    For Use With
    Accuracy
    Each
    1/4 NPT Female Threaded Pipe Connection
    0 to 22 to 2.52.5 to 3.5300-40 to 200-40 to 2003 1/4"3 1/4"1 1/2"BlackAir, Water, Hydraulic Fluid, Carbon Dioxide, Nitrogen, Hydrogen, Argon, Acetylene±5%2238K210000000
     

    Back-Pressure-Regulating Valves for Air and Inert Gas

    Image of Product. Front orientation. Pressure-Regulating Valves. Back-Pressure-Regulating Valves for Air and Inert Gas.
    Often used to protect equipment running on air compressors, these valves obstruct flow to maintain sufficient operating pressure in your system. If the system pressure exceeds the set pressure, they exhaust through the unthreaded relief port. Adjust the set pressure within the range. Valves have two gauge ports.
    Inlet
    Outlet
    Gauge Port
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Pipe
    Size
    Location
    Pressure Adjustment
    Method
    Pressure Gauge
    Included
    Pipe
    Size
    Location
    Connection
    Relief Port
    Location
    End-to-End
    Lg.
    For Use With
    Temp. Range,
    ° F
    Outlet Pressure,
    psi
    Each
    NPT Female
     
    Aluminum Body—Buna-N Diaphragm and Seal
    1/4
    Side2501/4
    SideKnobNo1/4
    SideNPT FemaleSide3"Air, Inert Gas0 to 1500 to 24783K510000000
    3/8
    Side2503/8
    SideKnobNo1/4
    SideNPT FemaleSide3"Air, Inert Gas0 to 1500 to 24783K53000000
    1/2
    Side2501/2
    SideKnobNo1/4
    SideNPT FemaleSide3"Air, Inert Gas0 to 1500 to 24783K55000000
     

    Medium-Pressure Differential Gauges

    Popular for use with natural gas, these gauges measure pressure differences in pipelines and filters with a maximum pressure of 1,500 pounds per square inch.
    Aluminum Case with Aluminum Connections—Single Scale (Pounds per Square Inch)
    Image of Product. Front orientation. Differential Pressure Gauges. Medium-Pressure Differential Gauges.
    Dial
    Dia.
    Max. Pressure,
    psi
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    For Use With
    Accuracy
    Pressure,
    psi
    Graduations,
    psi
    Pressure Numeric
    Increments, psi
    Each
    1/4 NPT Female Threaded Pipe Connection
    2 1/2"1,5000 to 1500 to 200Water, Hydraulic Fluid, Gasoline, Natural Gas±2%0 to 20.10.54028K1120000000
    4 1/2"1,5000 to 1500 to 200Water, Hydraulic Fluid, Gasoline, Natural Gas±2%0 to 20.10.54028K312000000
     
    316 Stainless Steel Case with 316 Stainless Steel Connections—Single Scale (Pounds per Square Inch)
    Image of Product. Front orientation. Differential Pressure Gauges. Medium-Pressure Differential Gauges.
    Gauges with 316 stainless steel case are more corrosion resistant than gauges with an aluminum case.
    Dial
    Dia.
    Max. Pressure,
    psi
    Environment
    Temp. Range, ° F
    Process Temp.
    Range, ° F
    For Use With
    Accuracy
    Pressure,
    psi
    Graduations,
    psi
    Pressure Numeric
    Increments, psi
    Each
    1/4 NPT Female Threaded Pipe Connection
    2 1/2"1,5000 to 1500 to 200Water, Hydraulic Fluid, Gasoline, Natural Gas±2%0 to 20.10.54028K4120000000
    4 1/2"1,5000 to 1500 to 200Water, Hydraulic Fluid, Gasoline, Natural Gas±2%0 to 20.10.54028K612000000
     

    High-Flow Precision Compressed Air Regulators

    Deliver a large volume of air at a steady pressure for precise, repeatable movement in cylinders, actuators, and automated systems. No matter how irregular your compressed air supply pressure is, these precision regulators have a flexible diaphragm that automatically adjusts to input pressure changes and an aspirator tube that creates a feedback loop to maintain set pressure within a tight band.
    Relieving Regulators
    Image of Product. Front orientation. Compressed Air Regulators. High-Flow Precision Compressed Air Regulators.
    Image of Product. Mounting Bracket. Front orientation. Filter/Regulator/Lubricator Mounting Brackets. High-Flow Precision Compressed Air Regulators.

    Mounting Bracket

    Relieving regulators exhaust when the downstream pressure exceeds the set pressure.
    BSPP Inlet Thread—BSPP threads are also known as G threads.
    Mounting Brackets—Add mounting brackets to attach the regulator to a wall or your equipment.
    Regulators
    Mounting
    Brackets
    Pipe
    Size
    Overall
    Inlet
    Outlet
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Gauge
    Included
    No. of Gauge
    Ports
    Wd.
    Ht.
    Housing
    Material
    Max. Temp.,
    ° F
    Pressure Regulation,
    psi
    Each
    Each
    NPT Female Inlet × NPT Female Outlet
     
    ±0.1% Regulating Accuracy
    1/2
    1/2
    225 scfm @ 100 psi250No24"7 5/8"Aluminum2000 to 21888K21400000001888K171000000
     
    ±0.05% Regulating Accuracy
    1/4
    1/4
    80 scfm @ 100 psi250No23"6 1/8"Aluminum1600 to 21888K10000001888K50000
    3/8
    3/8
    80 scfm @ 100 psi250No23"6 1/8"Aluminum1600 to 21888K20000001888K50000
    1/2
    1/2
    80 scfm @ 100 psi250No23"6 1/8"Aluminum1600 to 21888K30000001888K50000
     
    BSPP Female Inlet × BSPP Female Outlet
     
    ±0.05% Regulating Accuracy
    1/4
    1/4
    80 scfm @ 100 psi250No23"6 1/8"Aluminum1600 to 21888K2180000001888K50000
    3/8
    3/8
    80 scfm @ 100 psi250No23"6 1/8"Aluminum1600 to 21888K2190000001888K50000
    1/2
    1/2
    80 scfm @ 100 psi250No23"6 1/8"Aluminum1600 to 21888K2110000001888K50000
     
    Pressure Gauges
    Nonrelieving Regulators
    Image of Product. Front orientation. Compressed Air Regulators. High-Flow Precision Compressed Air Regulators.
    Image of Product. Mounting Bracket. Front orientation. Filter/Regulator/Lubricator Mounting Brackets. High-Flow Precision Compressed Air Regulators.

    Mounting Bracket

    Nonrelieving regulators don’t exhaust any downstream pressure—a helpful setup in highly controlled environments. To prevent pressure buildup, manually vent them or use a relief valve.
    BSPP Inlet Thread—BSPP threads are also known as G threads.
    Mounting Brackets—Add mounting brackets to attach the regulator to a wall or your equipment.
    Regulators
    Mounting
    Brackets
    Pipe
    Size
    Overall
    Inlet
    Outlet
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Gauge
    Included
    No. of Gauge
    Ports
    Wd.
    Ht.
    Housing
    Material
    Max. Temp.,
    ° F
    Pressure Regulation,
    psi
    Each
    Each
    NPT Female Inlet × NPT Female Outlet
     
    ±0.1% Regulating Accuracy
    3/4
    3/4
    250 scfm @ 100 psi250No24"7 5/8"Aluminum2000 to 21888K22600000001888K171000000
     
    ±0.05% Regulating Accuracy
    1/4
    1/4
    80 scfm @ 100 psi250No23"6 1/8"Aluminum1600 to 21888K2160000001888K50000
    1/2
    1/2
    80 scfm @ 100 psi250No23"6 1/8"Aluminum1600 to 21888K2130000001888K50000
     
    BSPP Female Inlet × BSPP Female Outlet
     
    ±0.05% Regulating Accuracy
    1/4
    1/4
    80 scfm @ 100 psi250No23"6 1/8"Aluminum1600 to 21888K2210000001888K50000
     
    Pressure Gauges

    Differential Pressure Transmitters with Dial Indicator for Air

    Check the difference in air pressure between two inputs at the source using the dial indicator or remotely using a receiver. The dial indicator on these transmitters operates independently and shows differential pressure in real time for troubleshooting. Also known as transducers, these transmitters convert pressure to an electrical signal that is interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. They are often used to indicate a filter is clogged or help you maintain a certain air pressure in ovens, dryers, and HVAC systems. All are CE marked, so they meet European safety standards.
    When measuring pressure in ductwork, pair them with a static pressure probe.
    For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range. Connect them using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    Aluminum HousingAbout Aluminum Housing
    Image of Product. Front orientation. Differential Pressure Transmitters. Differential Pressure Transmitters with Dial Indicator for Air.
    Connection
    Pressure Differential,
    in. H₂O
    Max. Input
    Pressure, psi
    Input Voltage,
    V DC
    Pipe
    Size
    For No.
    of Wires
    Mounting Hardware
    Included
    No. of Mounting
    Holes
    Dia.
    Certification
    For Use
    With
    Accuracy
    Pipe
    Fitting
    Material
    Temp. Range,
    ° F
    Each
    4 to 20 mA Output Signal—Screw Terminals
    0 to 2210 to 351/8
    2No35 1/2"CE Marked
    Air±2%NPT FemaleThreaded
    Aluminum
    20 to 12038525K2130000000
    0 to 3210 to 351/8
    2No35 1/2"CE Marked
    Air±2%NPT FemaleThreaded
    Aluminum
    20 to 12038525K214000000
    0 to 10210 to 351/8
    2No35 1/2"CE Marked
    Air±2%NPT FemaleThreaded
    Aluminum
    20 to 12038525K215000000
     

    High-Accuracy Differential Pressure Transmitters

    At least twice as accurate as standard transmitters, these transmitters sense differential pressure at an accuracy of ±0.25%. Use them in laboratories or testing applications where the difference in pressure between two points needs to be measured with high accuracy. These transmitters are often used to indicate a filter is clogged or help you maintain a certain pressure in pumps, HVAC, cooling, and other air and liquid systems. They convert differential pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. All transmitters are rated NEMA 4 for protection in washdown environments.
    For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the pressure range and output signal of the transmitter. As the differential increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range. Connect them using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
    Aluminum HousingAbout Aluminum Housing
    Image of Product. Front orientation. Contains Annotated. Differential Pressure Transmitters. High-Accuracy Differential Pressure Transmitters.
    Mounting
    Holes
    Connection
    Pressure Differential,
    psi
    Max. Input
    Pressure, psi
    Input Voltage,
    V DC
    Pipe
    Size
    For No.
    of Wires
    Mounting Hardware
    Included
    Dia.
    No.
    of
    Ht.
    Wd.
    Enclosure
    Rating
    For Use
    With
    Accuracy
    Pipe
    Fitting
    Material
    Temp. Range,
    ° F
    Each
    4 to 20 mA Output Signal—Screw Terminals
    0 to 23509 to 301/4
    2Yes5/32"43 1/8"2 7/16"NEMA 4
    Air, Water±0.25%NPT FemaleThreaded
    17-4 PH Stainless Steel
    0 to 1759917K12000000000
     