McMaster-Carr logo
    Filter by
    System of Measurement
    For Use With
    Connects To
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    1,088 Products

    Flowmeters

    Check the flow rate of liquids in your system. As your liquid flows through these flowmeters, it pushes an indicator up the scale, showing you the flow rate. Mount them vertically inline with your piping system, so liquid flows up from the bottom. They’re made from acrylic, so they’re completely clear to help you inspect your liquid’s color and clarity for any problems. They also have a white backing to help you read the scale clearly.
    These flowmeters are calibrated with water but can be used with other liquids except for oil. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    Cylindrical Body
    Image of Product. Front orientation. Flowmeters. Flowmeters, Cylindrical Body, Female.
    Image of Product. Front orientation. Flowmeters. Flowmeters, Cylindrical Body, Male.
    Image of Product. Front orientation. Flowmeter Mounting Fittings. Flowmeters.
    Image of Product. Front orientation. Flowmeter Repair Kits. Flowmeters.

    Female

    Male

    Replacement

    Straights

    Replacement

    Flowmeter Repair

    Kits

    Polypropylene Fitting—Polypropylene fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    PVC Fitting—PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Brass Fitting—Brass fittings resist impact better than polypropylene and PVC fittings.
    316 Stainless Steel Fitting—316 stainless steel fittings resist impact better than polypropylene and PVC fittings.
    Calibration Certificate Traceable to NIST—Flowmeters with a calibration certificate traceable to NIST states that the flowmeter has passed a test for accuracy.
    Flowmeters
    Replacement
    Straights
    Replacement
    Flowmeter Repair Kits
    Flow
    Temp.,
    ° F
    Flowmeters
    Calibration
    Certificate Traceable to NIST
    US Customary,
    gpm
    Metric,
    L/min
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Each
    Each
    Each
    Each
    Acrylic Plastic Body with Polypropylene Fittings
     
    1/4 NPT Female
    0.025 to 0.250.1 to 18 3/16"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical4350K450000000———0———0———0
    0.05 to 0.50.2 to 28 3/16"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical4350K511000000———0———0———0
    0.1 to 10.4 to 48 3/16"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical8051K152000000———0———0———0
    0.2 to 21 to 7.58 3/16"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical8051K153000000———0———0———0
    0.3 to 31.5 to 118 3/16"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical8051K154000000———0———0———0
    0.5 to 52 to 208 3/16"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical8051K155000000———0———0———0
     
    3/8 NPT Female
    0.025 to 0.250.1 to 18 3/16"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical4350K512000000———0———0———0
    0.05 to 0.50.2 to 28 3/16"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical4350K513000000———0———0———0
    0.1 to 10.4 to 48 3/16"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical4350K41000000———0———0———0
    0.2 to 21 to 7.58 3/16"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical4350K46000000———0———0———0
    0.3 to 31.5 to 118 3/16"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical4350K47000000———0———0———0
     
    1/2 NPT Female
    0.025 to 0.250.1 to 18 3/16"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical8051K156000000———0———0———0
    0.05 to 0.50.2 to 28 3/16"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical8051K157000000———0———0———0
    0.1 to 10.4 to 48 3/16"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical4350K515000000———0———0———0
    0.2 to 21 to 7.58 3/16"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical4350K516000000———0———0———0
    0.3 to 31.5 to 118 3/16"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical4350K517000000———0———0———0
    0.5 to 52 to 208 3/16"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical4350K42000000———0———0———0
     
    3/4 NPT Female
    1 to 104 to 3811"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical4350K43000000———0———0———0
    2 to 208 to 8011"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical4350K518000000———0———0———0
     
    1 NPT Female
    1 to 104 to 3811"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical4350K519000000———0———0———0
    2 to 208 to 8011"±5%150 psi @ 70° F33150Fluoroelastomer
    Vertical4350K44000000———0———0———0
     
    Acrylic Plastic Body with PVC Fittings
     
    3/8 NPT Female
    0.1 to 18 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K951000000———08051K2720000006766T301000000
    0.2 to 28 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K954000000———08051K272000006766T30100000
    0.3 to 3.58 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K957000000———08051K272000006766T30100000
    0.5 to 58 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K961000000———08051K272000006766T30100000
     
    1 NPT Female
    0.5 to 510 1/4"±3%125 psi @ 70° F33130EPM RubberVertical9746K28000000———08051K245000006766T1100000
    1 to 1010 1/4"±3%125 psi @ 70° F33130EPM RubberVertical9746K31000000———08051K245000006766T1100000
    1.5 to 1510 1/4"±3%125 psi @ 70° F33130EPM RubberVertical9746K29000000———08051K245000006766T1100000
    2.1 to 2110 1/4"±3%125 psi @ 70° F33130EPM RubberVertical9746K32000000———08051K245000006766T1100000
    3.05 to 30.510 1/4"±3%125 psi @ 70° F33130EPM RubberVertical9746K33000000———08051K245000006766T1100000
    10 to 5040 to 20012"±5%130 psi @ 70° F33130Fluoroelastomer
    Vertical4350K523000000———0———0———0
     
    1 1/2 NPT Female
    4 to 4015 to 15014"±5%130 psi @ 70° F33130Fluoroelastomer
    Vertical8051K15800000000———0———0———0
    20 to 10075 to 37514"±5%150 psi @ 70° F33130Fluoroelastomer
    Vertical4350K52700000000———0———0———0
     
    1 1/2 NPT Male
    4 to 4012 1/16"±6%125 psi @ 70° F33130EPM RubberVertical9746K340000008051K81600000008051K246000006766T1200000
    5 to 5012 1/16"±6%125 psi @ 70° F33130EPM RubberVertical9746K350000008051K8170000008051K246000006766T1200000
     
    2 NPT Female
    4 to 4013 1/4"±4%125 psi @ 70° F33130EPM RubberVertical8051K116000000———0———0———0
    6 to 6013 1/4"±4%125 psi @ 70° F33130EPM RubberVertical9746K36000000———08051K2470000006766T1300000
    8 to 8013 1/4"±4%125 psi @ 70° F33130EPM RubberVertical9746K41000000———08051K2470000006766T1300000
    20 to 20013 1/4"±4%125 psi @ 70° F33130EPM RubberVertical9746K37000000———08051K2470000006766T1300000
    45 to 16013 1/4"±4%125 psi @ 70° F33130EPM RubberVertical9746K38000000———08051K2470000006766T1300000
    56 to 20013 1/4"±4%125 psi @ 70° F33130EPM RubberVertical9746K39000000———08051K2470000006766T1300000
     
    Acrylic Plastic Body with Brass Fittings
     
    3/8 NPT Female
    0.1 to 18 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K9480000008051K9620000008051K249000006766T30100000
    0.2 to 28 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K9520000008051K9650000008051K249000006766T30100000
    0.3 to 3.58 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K9550000008051K9680000008051K249000006766T30100000
    0.5 to 58 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K9580000008051K9720000008051K249000006766T30100000
     
    1/2 NPT Female
    0.1 to 18 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K117000000———0———0———0
    0.2 to 28 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K118000000———0———0———0
    0.3 to 3.58 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K119000000———0———0———0
    0.5 to 58 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K121000000———0———0———0
     
    1 NPT Female
    0.5 to 510 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K843000000———08051K2530000006766T1100000
    1 to 1010 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K844000000———08051K2530000006766T1100000
    1.5 to 1510 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K845000000———08051K2530000006766T1100000
    2.1 to 2110 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K846000000———08051K2530000006766T1100000
    3.05 to 30.510 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K847000000———08051K2530000006766T1100000
     
    1 1/2 NPT Male
    4 to 4012 1/16"±6%125 psi @ 70° F33130EPM RubberVertical8051K848000000———08051K2540000006766T1200000
    5 to 5012 1/16"±6%125 psi @ 70° F33130EPM RubberVertical8051K849000000———08051K2540000006766T1200000
     
    2 NPT Female
    4 to 4013 1/4"±4%125 psi @ 70° F33130EPM RubberVertical8051K12200000000———0———0———0
    8 to 8013 1/4"±4%125 psi @ 70° F33130EPM RubberVertical8051K12300000000———0———0———0
    20 to 20013 1/4"±4%125 psi @ 70° F33130EPM RubberVertical8051K12400000000———0———0———0
    45 to 16013 1/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K12500000000———0———0———0
    56 to 20013 1/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K12600000000———0———0———0
     
    Acrylic Plastic Body with 316 Stainless Steel Fittings
     
    3/8 NPT Female
    0.1 to 18 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K949000000———08051K2570000006766T30100000
    0.2 to 28 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K953000000———08051K2570000006766T30100000
    0.3 to 3.58 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K956000000———08051K2570000006766T30100000
    0.5 to 58 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K959000000———08051K2570000006766T30100000
     
    1/2 NPT Female
    0.1 to 18 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K127000000———0———0———0
    0.2 to 28 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K128000000———0———0———0
    0.3 to 3.58 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K129000000———0———0———0
    0.5 to 58 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K131000000———0———0———0
     
    1 NPT Female
    0.5 to 510 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K871000000———08051K2610000006766T1100000
    1 to 1010 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K872000000———08051K2610000006766T1100000
    1.5 to 1510 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K873000000———08051K2610000006766T1100000
    2.1 to 2110 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K874000000———08051K2610000006766T1100000
    3.05 to 30.510 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K875000000———08051K2610000006766T1100000
     
    1 1/2 NPT Male
    4 to 4012 1/16"±6%125 psi @ 70° F33130EPM RubberVertical8051K876000000———08051K2620000006766T1200000
    5 to 5012 1/16"±6%125 psi @ 70° F33130EPM RubberVertical8051K877000000———08051K2620000006766T1200000
     
    2 NPT Female
    6 to 6013 1/4"±4%125 psi @ 70° F33130EPM RubberVertical8051K87800000000———08051K2630000006766T1300000
    8 to 8013 1/4"±4%125 psi @ 70° F33130EPM RubberVertical8051K87900000000———08051K2630000006766T1300000
    20 to 20013 1/4"±4%125 psi @ 70° F33130EPM RubberVertical8051K88100000000———08051K2630000006766T1300000
    45 to 16013 1/4"±4%125 psi @ 70° F33130EPM RubberVertical8051K88200000000———08051K2630000006766T1300000
    56 to 20013 1/4"±4%125 psi @ 70° F33130EPM RubberVertical8051K88300000000———08051K2630000006766T1300000
     
    Rectangular Body
    Image of Product. Front orientation. Flowmeters. Flowmeters, Rectangular Body, Female.
    Image of Product. Front orientation. Flowmeters. Flowmeters, Rectangular Body, Male.
    Image of Product. Front orientation. Flowmeter Mounting Fittings. Flowmeters.
    Image of Product. Front orientation. Flowmeter Repair Kits. Flowmeters.

    Female

    Male

    Replacement

    Straights

    Replacement

    Flowmeter Repair

    Kits

    Flowmeters with a rectangular body are made from a single block of acrylic, so they’re more durable and resist impact better than flowmeters with a cylindrical body. However, they’re not as durable as flowmeters with a protective case.
    PVC Fitting—PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Brass Fitting—Brass fittings resist impact better than polypropylene and PVC fittings.
    316 Stainless Steel Fitting—316 stainless steel fittings resist impact better than polypropylene and PVC fittings.
    Calibration Certificate Traceable to NIST—Flowmeters with a calibration certificate traceable to NIST states that the flowmeter has passed a test for accuracy.
    Flowmeters
    Replacement
    Straights
    Replacement
    Flowmeter Repair Kits
    Temp.,
    ° F
    Flowmeters
    Calibration
    Certificate Traceable to NIST
    Flow
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Each
    Each
    Each
    Each
    Acrylic Plastic Body with PVC Fittings
     
    1/4 NPT Male
    0.7 gph to 7 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K132000000———0———0———0
    1 gph to 12 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K1500000———08051K2410000006766T14000000
    2.2 gph to 22 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K1600000———08051K241000006766T1400000
    4.4 gph to 44 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K1700000———08051K241000006766T1400000
    6 gph to 60 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K1800000———08051K241000006766T1400000
    7.5 gph to 75 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K13300000———0———0———0
     
    1/2 NPT Female
    0.1 gpm to 1 gpm6 1/2"±5%125 psi @ 70° F33130EPM RubberVertical8051K94400000———08051K243000006766T1700000
    0.1 gpm to 1 gpm9 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K134000000———0———0———0
    0.2 gpm to 2 gpm6 1/2"±5%125 psi @ 70° F33130EPM RubberVertical8051K1100000———08051K243000006766T1700000
    0.2 gpm to 2 gpm9 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K130000008051K80300000008051K243000006766T1700000
    0.35 gpm to 3.5 gpm9 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K9460000008051K9470000008051K24300000———0
    0.35 gpm to 3.6 gpm6 1/2"±5%125 psi @ 70° F33130EPM RubberVertical8051K13500000———0———0———0
    0.4 gpm to 5 gpm6 1/2"±5%125 psi @ 70° F33130EPM RubberVertical8051K1200000———08051K243000006766T1700000
    0.5 gpm to 5 gpm9 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K140000008051K8040000008051K243000006766T1700000
     
    3/4 NPT Female
    0.2 gpm to 2 gpm14 13/16"±2%125 psi @ 70° F33130EPM RubberVertical8051K136000000———0———0———0
    0.35 gpm to 3.5 gpm14 13/16"±2%125 psi @ 70° F33130EPM RubberVertical8051K137000000———0———0———0
    0.5 gpm to 5 gpm14 13/16"±2%125 psi @ 70° F33130EPM RubberVertical8051K280000008051K8050000008051K244000006766T1600000
    1 gpm to 10 gpm14 13/16"±2%125 psi @ 70° F33130EPM RubberVertical8051K290000008051K8060000008051K244000006766T1600000
     
    1 NPT Female
    1 gpm to 10 gpm8 3/8"±4%125 psi @ 70° F33130EPM RubberVertical8051K25000000———08051K275000006766T1500000
    1.5 gpm to 15 gpm8 3/8"±4%125 psi @ 70° F33130EPM RubberVertical8051K26000000———08051K275000006766T1500000
    2 gpm to 20 gpm8 3/8"±4%125 psi @ 70° F33130EPM RubberVertical8051K27000000———08051K275000006766T1500000
     
    Acrylic Plastic Body with Brass Fittings
     
    1/4 NPT Female
    0.7 gph to 7 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K13800000———0———0———0
    1 gph to 12 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K85600000———08051K248000006766T1400000
    2.2 gph to 22 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K85700000———08051K248000006766T1400000
    4.4 gph to 44 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K85800000———08051K248000006766T1400000
    6 gph to 60 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K85900000———08051K248000006766T1400000
    7.5 gph to 75 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K13900000———0———0———0
     
    1/2 NPT Female
    0.1 gpm to 1 gpm6 1/2"±5%125 psi @ 70° F33130EPM RubberVertical8051K861000000———08051K251000006766T1700000
    0.1 gpm to 1 gpm9 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K141000000———0———0———0
    0.2 gpm to 2 gpm6 1/2"±5%125 psi @ 70° F33130EPM RubberVertical8051K833000000———08051K251000006766T1700000
    0.2 gpm to 2 gpm9 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K835000000———08051K25100000———0
    0.35 gpm to 3.5 gpm9 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K862000000———08051K25100000———0
    0.35 gpm to 3.6 gpm6 1/2"±5%125 psi @ 70° F33130EPM RubberVertical8051K142000000———0———0———0
    0.4 gpm to 5 gpm6 1/2"±5%125 psi @ 70° F33130EPM RubberVertical8051K834000000———08051K251000006766T1700000
    0.5 gpm to 5 gpm9 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K836000000———08051K25100000———0
     
    3/4 NPT Female
    0.2 gpm to 2 gpm14 13/16"±2%125 psi @ 70° F33130EPM RubberVertical8051K143000000———0———0———0
    0.35 gpm to 3.5 gpm14 13/16"±2%125 psi @ 70° F33130EPM RubberVertical8051K144000000———0———0———0
    0.5 gpm to 5 gpm14 13/16"±2%125 psi @ 70° F33130EPM RubberVertical8051K837000000———08051K2520000006766T1600000
    1 gpm to 10 gpm14 13/16"±2%125 psi @ 70° F33130EPM RubberVertical8051K838000000———08051K2520000006766T1600000
     
    1 NPT Female
    1 gpm to 10 gpm8 3/8"±4%125 psi @ 70° F33130EPM RubberVertical8051K839000000———08051K2730000006766T1500000
    1.5 gpm to 15 gpm8 3/8"±4%125 psi @ 70° F33130EPM RubberVertical8051K841000000———08051K2730000006766T1500000
    2 gpm to 20 gpm8 3/8"±4%125 psi @ 70° F33130EPM RubberVertical8051K842000000———08051K2730000006766T1500000
     
    Acrylic Plastic Body with 316 Stainless Steel Fittings
     
    1/4 NPT Female
    0.7 gph to 7 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K145000000———0———0———0
    1 gph to 12 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K884000000———08051K256000006766T1400000
    2.2 gph to 22 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K885000000———08051K256000006766T1400000
    4.4 gph to 44 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K886000000———08051K256000006766T1400000
    6 gph to 60 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K887000000———08051K256000006766T1400000
    7.5 gph to 75 gph4 3/4"±6%125 psi @ 70° F33130EPM RubberVertical8051K146000000———0———0———0
     
    1/2 NPT Female
    0.1 gpm to 1 gpm6 1/2"±5%125 psi @ 70° F33130EPM RubberVertical8051K51000000———08051K258000006766T1700000
    0.1 gpm to 1 gpm9 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K147000000———0———0———0
    0.2 gpm to 2 gpm6 1/2"±5%125 psi @ 70° F33130EPM RubberVertical8051K863000000———08051K258000006766T1700000
    0.2 gpm to 2 gpm9 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K54000000———08051K258000006766T1700000
    0.35 gpm to 3.5 gpm9 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K56000000———08051K258000006766T1700000
    0.35 gpm to 3.6 gpm6 1/2"±5%125 psi @ 70° F33130EPM RubberVertical8051K148000000———0———0———0
    0.5 gpm to 5 gpm6 1/2"±5%125 psi @ 70° F33130EPM RubberVertical8051K53000000———08051K258000006766T1700000
    0.5 gpm to 5 gpm9 1/4"±3%125 psi @ 70° F33130EPM RubberVertical8051K864000000———08051K25800000———0
     
    3/4 NPT Female
    0.2 gpm to 2 gpm14 13/16"±2%125 psi @ 70° F33130EPM RubberVertical8051K149000000———0———0———0
    0.35 gpm to 3.5 gpm14 13/16"±2%125 psi @ 70° F33130EPM RubberVertical8051K151000000———0———0———0
    0.5 gpm to 5 gpm14 13/16"±2%125 psi @ 70° F33130EPM RubberVertical8051K865000000———08051K2590000006766T1600000
    1 gpm to 10 gpm14 13/16"±2%125 psi @ 70° F33130EPM RubberVertical8051K866000000———08051K2590000006766T1600000
     
    1 NPT Female
    1 gpm to 10 gpm8 3/8"±4%125 psi @ 70° F33130EPM RubberVertical8051K867000000———08051K2710000006766T1500000
    1.5 gpm to 15 gpm8 3/8"±4%125 psi @ 70° F33130EPM RubberVertical8051K868000000———08051K2710000006766T1500000
    2 gpm to 20 gpm8 3/8"±4%125 psi @ 70° F33130EPM RubberVertical8051K869000000———08051K2710000006766T1500000
     

    Panel-Mount Flowmeters for Gases

    Monitor the flow rate of air and other gases from your instrument panel—these flowmeters have fittings on the back for panel mounting. They should be mounted vertically inline with your piping system, so gas flows up from the bottom. As gas passes through, it pushes an indicator up the scale, showing you the flow rate. With an acrylic body, they're completely clear, so you can inspect your gas’s color and clarity for any problems.
    These flowmeters are calibrated with air but can be used with other gases. If you’re using these with a gas other than air, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your gas.
    Choose a fitting material that is compatible with the gas you're running through your line.
    Flowmeters
    Image of Product. Front orientation. Contains Annotated. Flowmeters. Panel-Mount Flowmeters for Gases, Flowmeters.
    Image of Product. Front orientation. Flowmeter Repair Kits. Panel-Mount Flowmeters for Gases.

    Replacement Flowmeter

    Repair Kits

    PVC Fitting—PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Brass Fitting—Brass fittings resist impact better than PVC fittings.
    1/4 NPT Threaded Female Pipe × 1/2 NPT Threaded Male Pipe—Flowmeters with a female × male connection have internal NPT female threads and external NPT male threads.
    Calibration Certificate Traceable to NIST—Flowmeters with a calibration certificate traceable to NIST states that the flowmeter has passed a test for accuracy.
    Flowmeters
    Replacement
    Flowmeter Repair Kits
    Temp.,
    ° F
    Flowmeters
    Calibration
    Certificate Traceable to NIST
    Flow
    Overall
    Ht.
    Ctr.-to-Ctr.
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Each
    Each
    Each
    Acrylic Plastic Body with PVC Fittings
     
    1/4 NPT Threaded Female Pipe × 1/2 NPT Threaded Male Pipe
    0.8 scfm to 8.2 scfm6 7/8"5"±4%100 psi @ 70° F33100EPM RubberVertical41945K420000000———06766T19000000
    0.8 scfm to 8.2 scfm8 7/16"6.437"±3%100 psi @ 70° F33100EPM RubberVertical41945K44000000———06766T1900000
    2.2 scfm to 22 scfm8 7/16"6.437"±3%100 psi @ 70° F33100EPM RubberVertical41945K45000000———06766T1900000
    2.3 scfm to 23 scfm6 7/8"5"±4%100 psi @ 70° F33100EPM RubberVertical41945K43000000———06766T1900000
     
    1/2 NPT Female
    2 scfm to 20 scfm14 1/2"12 1/4"±2%100 psi @ 70° F33100EPM RubberVertical41945K380000003281K10700000006766T2200000
    4.2 scfm to 42 scfm14 1/2"12 1/4"±2%100 psi @ 70° F33100EPM RubberVertical41945K390000003281K1080000006766T2200000
     
    1 NPT Male
    4 scfm to 40 scfm9 1/8"6.437"±4%100 psi @ 70° F33100EPM RubberVertical41945K360000003281K1090000006766T2100000
    6 scfm to 60 scfm9 1/8"6.437"±4%100 psi @ 70° F33100EPM RubberVertical41945K370000003281K1110000006766T2100000
     
    Acrylic Plastic Body with Brass Fittings
     
    1/4 NPT Female
    2 scfh to 20 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K32000003281K240000006766T1800000
    3 scfh to 30 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K33000003281K1010000006766T1800000
    6 scfh to 60 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K34000003281K250000006766T1800000
    10 scfh to 100 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K35000003281K1020000006766T1800000
    15 scfh to 180 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K41000003281K1030000006766T1800000
    0.4 scfm to 4 scfm4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K31000003281K260000006766T1800000
     
    Flowmeters with Flow-Control Knob
    Image of Product. Front orientation. Contains Annotated. Flowmeters. Panel-Mount Flowmeters for Gases, Flowmeters with Flow-Control Knob.
    Image of Product. Front orientation. Flowmeter Repair Kits. Panel-Mount Flowmeters for Gases.

    Replacement Flowmeter

    Repair Kits

    Flowmeters with a flow-control knob let you open and close the valve at the inlet to adjust the flow rate within the range.
    PVC Fitting—PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Brass Fitting—Brass fittings resist impact better than PVC fittings.
    303 Stainless Steel Fitting—303 stainless steel fittings resist impact better than PVC fittings.
    316 Stainless Steel Fitting—316 stainless steel fittings resist impact better than PVC fittings.
    1/4 NPT Threaded Female Pipe × 1/2 NPT Threaded Male Pipe—Flowmeters with a female × male connection have internal NPT female threads and external NPT male threads.
    Calibration Certificate Traceable to NIST—Flowmeters with a calibration certificate traceable to NIST states that the flowmeter has passed a test for accuracy.
    Flowmeters
    Replacement
    Flowmeter Repair Kits
    Temp.,
    ° F
    Flowmeters
    Calibration
    Certificate Traceable to NIST
    Flow
    Overall
    Ht.
    Ctr.-to-Ctr.
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Each
    Each
    Each
    Acrylic Plastic Body with PVC Fittings
     
    1/4 NPT Threaded Female Pipe × 1/2 NPT Threaded Male Pipe
    4.2 scfh to 42 scfh8 7/16"6.437"±3%125 psi @ 70° F33100EPM RubberVertical41945K1180000000———0———0
    10 scfh to 100 scfh8 7/16"6.437"±3%125 psi @ 70° F33100EPM RubberVertical41945K119000000———0———0
    0.4 scfm to 4 scfm6 7/8"5"±4%125 psi @ 70° F33100EPM RubberVertical41945K122000000———0———0
    25 scfh to 175 scfh8 7/16"6.437"±3%125 psi @ 70° F33100EPM RubberVertical41945K121000000———0———0
    0.8 scfm to 8.2 scfm6 7/8"5"±4%100 psi @ 70° F33100EPM RubberVertical41945K52000000———06766T24000000
    0.8 scfm to 8.2 scfm8 7/16"6.437"±3%100 psi @ 70° F33100EPM RubberVertical41945K54000000———06766T2400000
    1.5 scfm to 15 scfm6 7/8"5"±4%125 psi @ 70° F33100EPM RubberVertical41945K123000000———0———0
    2.2 scfm to 22 scfm8 7/16"6.437"±3%100 psi @ 70° F33100EPM RubberVertical41945K55000000———06766T2400000
    2.3 scfm to 23 scfm6 7/8"5"±4%100 psi @ 70° F33100EPM RubberVertical41945K53000000———06766T2400000
     
    1/2 NPT Female
    0.8 scfm to 8 scfm14 1/2"12 1/4"±2%125 psi @ 70° F33100EPM RubberVertical41945K124000000———06766T2600000
    1.4 scfm to 14.4 scfm14 1/2"12 1/4"±2%125 psi @ 70° F33100EPM RubberVertical41945K125000000———06766T2600000
    2 scfm to 20 scfm14 1/2"12 1/4"±2%100 psi @ 70° F33100EPM RubberVertical41945K82000000———06766T2600000
    4.2 scfm to 42 scfm14 1/2"12 1/4"±2%100 psi @ 70° F33100EPM RubberVertical41945K83000000———06766T2600000
     
    1 NPT Female
    3 scfm to 25 scfm10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K211000000———0———0
    4 scfm to 50 scfm10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K46000000———0———0
    10 scfm to 100 scfm10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K212000000———0———0
     
    1 NPT Male
    4 scfm to 40 scfm9 1/8"6.437"±4%100 psi @ 70° F33100EPM RubberVertical41945K780000003281K11800000006766T2500000
    6 scfm to 60 scfm9 1/8"6.437"±4%100 psi @ 70° F33100EPM RubberVertical41945K790000003281K1190000006766T2500000
     
    Acrylic Plastic Body with Brass Fittings
     
    1/8 NPT Female
    0.1 scfh to 1 scfh4"3"±5%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K20100000———0———0
    0.2 scfh to 2 scfh4"3"±5%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K20200000———0———0
    0.4 scfh to 5 scfh4"3"±5%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K20300000———0———0
    0.5 scfh to 10 scfh4"3"±5%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K20400000———0———0
    4 scfh to 50 scfh4"3"±5%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K20500000———0———0
    10 scfh to 100 scfh4"3"±5%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K20600000———0———0
    20 scfh to 200 scfh4"3"±5%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K20700000———0———0
     
    1/4 NPT Female
    0.26 scfh to 2.6 scfh4 1/8"3"±6%125 psi @ 70° F33100EPM RubberVertical41945K101000000———0———0
    0.5 scfh to 5 scfh4 1/8"3"±6%125 psi @ 70° F33100EPM RubberVertical41945K102000000———0———0
    1 scfh to 10 scfh4 1/8"3"±6%125 psi @ 70° F33100EPM RubberVertical41945K103000000———0———0
    2 scfh to 20 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K740000003281K340000006766T2300000
    3 scfh to 30 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K750000003281K1040000006766T2300000
    6 scfh to 60 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K760000003281K350000006766T2300000
    10 scfh to 100 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K770000003281K1050000006766T2300000
    15 scfh to 180 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K510000003281K1060000006766T2300000
    0.4 scfm to 4 scfm4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K730000003281K360000006766T2300000
    1 scfm to 10 scfm6 5/8"5 1/2"±3%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K208000000———0———0
    4 scfm to 20 scfm6 5/8"5 1/2"±3%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K209000000———0———0
     
    1/4 NPT Threaded Female Pipe × 1/2 NPT Threaded Male Pipe
    4.2 scfh to 42 scfh8 7/16"6.437"±3%125 psi @ 70° F33100EPM RubberVertical41945K104000000———0———0
    10 scfh to 100 scfh8 7/16"6.437"±3%125 psi @ 70° F33100EPM RubberVertical41945K105000000———0———0
    0.4 scfm to 4 scfm6 7/8"5"±4%125 psi @ 70° F33100EPM RubberVertical41945K107000000———06766T2400000
    25 scfh to 175 scfh8 7/16"6.437"±3%125 psi @ 70° F33100EPM RubberVertical41945K106000000———0———0
    0.8 scfm to 8 scfm6 7/8"5"±4%125 psi @ 70° F33100EPM RubberVertical41945K108000000———06766T2400000
    1.5 scfm to 15 scfm6 7/8"5"±4%125 psi @ 70° F33100EPM RubberVertical41945K109000000———06766T2400000
    2.3 scfm to 23 scfm6 7/8"5"±4%125 psi @ 70° F33100EPM RubberVertical41945K111000000———06766T2400000
     
    1/2 NPT Female
    0.8 scfm to 8 scfm14 1/2"12 1/4"±2%125 psi @ 70° F33100EPM RubberVertical41945K112000000———06766T2600000
    1.4 scfm to 14.4 scfm14 1/2"12 1/4"±2%125 psi @ 70° F33100EPM RubberVertical41945K113000000———06766T2600000
    2 scfm to 20 scfm14 1/2"12 1/4"±2%125 psi @ 70° F33100EPM RubberVertical41945K114000000———06766T2600000
    5 scfm to 42 scfm14 1/2"12 1/4"±2%125 psi @ 70° F33100EPM RubberVertical41945K115000000———06766T2600000
     
    1 NPT Male
    4 scfm to 40 scfm9 1/8"6.437"±4%125 psi @ 70° F33100EPM RubberVertical41945K116000000———06766T2500000
    6 scfm to 60 scfm9 1/8"6.437"±4%125 psi @ 70° F33100EPM RubberVertical41945K117000000———06766T2500000
     
    Acrylic Plastic Body with 303 Stainless Steel Fittings
     
    1/8 NPT Female
    0.1 scfh to 1 scfh4"3"±5%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K213000000———0———0
    0.2 scfh to 2 scfh4"3"±5%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K214000000———0———0
    0.4 scfh to 5 scfh4"3"±5%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K215000000———0———0
    0.5 scfh to 10 scfh4"3"±5%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K216000000———0———0
    4 scfh to 50 scfh4"3"±5%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K217000000———0———0
    10 scfh to 100 scfh4"3"±5%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K218000000———0———0
    20 scfh to 200 scfh4"3"±5%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K219000000———0———0
     
    1/4 NPT Female
    0.5 scfm to 5 scfm6 5/8"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K42000000———0———0
    1 scfm to 10 scfm6 5/8"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K221000000———0———0
    4 scfm to 20 scfm6 5/8"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K44000000———0———0
     
    1 NPT Female
    3 scfm to 25 scfm10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K222000000———0———0
    4 scfm to 50 scfm10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K223000000———0———0
    10 scfm to 100 scfm10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K224000000———0———0
     
    Acrylic Plastic Body with 316 Stainless Steel Fittings
     
    1/4 NPT Female
    0.26 scfh to 2.6 scfh4 1/4"3"±6%125 psi @ 70° F33100EPM RubberVertical41945K126000000———0———0
    0.5 scfh to 5 scfh4 1/4"3"±6%125 psi @ 70° F33100EPM RubberVertical41945K127000000———0———0
    1 scfh to 10 scfh4 1/4"3"±6%125 psi @ 70° F33100EPM RubberVertical41945K128000000———0———0
    2 scfh to 20 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K110000003281K440000006766T2300000
    3 scfh to 30 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K120000003281K1340000006766T2300000
    6 scfh to 60 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K130000003281K450000006766T2300000
    10 scfh to 100 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K140000003281K1350000006766T2300000
    15 scfh to 180 scfh4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K150000003281K1360000006766T2300000
    0.4 scfm to 4 scfm4 1/8"3"±6%100 psi @ 70° F33100EPM RubberVertical41945K160000003281K460000006766T2300000
     
    1/4 NPT Threaded Female Pipe × 1/2 NPT Threaded Male Pipe
    4.2 scfh to 42 scfh8 7/16"6.437"±3%125 psi @ 70° F33100EPM RubberVertical41945K129000000———0———0
    10 scfh to 100 scfh8 7/16"6.437"±3%125 psi @ 70° F33100EPM RubberVertical41945K131000000———0———0
    0.4 scfm to 4 scfm6 7/8"5"±4%125 psi @ 70° F33100EPM RubberVertical41945K133000000———0———0
    25 scfh to 175 scfh8 7/16"6.437"±3%125 psi @ 70° F33100EPM RubberVertical41945K132000000———0———0
    0.8 scfm to 8.2 scfm6 7/8"5"±4%100 psi @ 70° F33100EPM RubberVertical41945K190000003281K1330000006766T2400000
    0.8 scfm to 8.2 scfm8 7/16"6.437"±3%100 psi @ 70° F33100EPM RubberVertical41945K21000000———06766T2400000
    1.5 scfm to 15 scfm6 7/8"5"±4%125 psi @ 70° F33100EPM RubberVertical41945K134000000———0———0
    2.2 scfm to 22 scfm8 7/16"6.437"±3%100 psi @ 70° F33100EPM RubberVertical41945K23000000———06766T2400000
    2.3 scfm to 23 scfm6 7/8"5"±4%100 psi @ 70° F33100EPM RubberVertical41945K220000003281K1290000006766T2400000
     
    1/2 NPT Female
    0.8 scfm to 8 scfm14 1/2"12 1/4"±2%125 psi @ 70° F33100EPM RubberVertical41945K135000000———06766T2600000
    1.44 scfm to 14.4 scfm14 1/2"12 1/4"±2%125 psi @ 70° F33100EPM RubberVertical41945K136000000———06766T2600000
    2 scfm to 20 scfm14 1/2"12 1/4"±2%100 psi @ 70° F33100EPM RubberVertical41945K170000003281K1250000006766T2600000
    4.2 scfm to 42 scfm14 1/2"12 1/4"±2%100 psi @ 70° F33100EPM RubberVertical41945K180000003281K1260000006766T2600000
     
    1 NPT Male
    4 scfm to 40 scfm9 1/8"6.437"±4%100 psi @ 70° F33100EPM RubberVertical41945K24000000———06766T2500000
    6 scfm to 60 scfm9 1/8"6.437"±4%100 psi @ 70° F33100EPM RubberVertical41945K25000000———06766T2500000
     

    Panel-Mount Flowmeters

    Fittings on the back let you install these flowmeters in instrument panels. Mount them vertically inline with your piping system, so liquid flows up from the bottom. As liquid passes through, it pushes an indicator up the scale, showing you the flow rate. With an acrylic body, they're completely clear, so you can inspect your liquid's color and clarity for any problems.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    Flowmeters
    Image of Product. Front orientation. Contains Annotated. Flowmeters. Panel-Mount Flowmeters, Flowmeters.
    Image of Product. Front orientation. Flowmeter Repair Kits. Panel-Mount Flowmeters.

    Replacement Flowmeter

    Repair Kits

    PVC Fitting—PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Brass Fitting—Brass fittings resist impact better than PVC fittings.
    1/4 NPT Threaded Female Pipe × 1/2 NPT Threaded Male Pipe—Flowmeters with a female × male connection have internal NPT female threads and external NPT male threads.
    Calibration Certificate Traceable to NIST—Flowmeters with a calibration certificate traceable to NIST states that the flowmeter has passed a test for accuracy.
    Flowmeters
    Replacement
    Flowmeter Repair Kits
    Temp.,
    ° F
    Flowmeters
    Calibration
    Certificate Traceable to NIST
    Flow
    Overall
    Ht.
    Ctr.-to-Ctr.
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Each
    Each
    Each
    Acrylic Plastic Body with PVC Fittings
     
    1/4 NPT Threaded Female Pipe × 1/2 NPT Threaded Male Pipe
    0.1 gpm to 1 gpm6 7/8"5"±4%125 psi @ 70° F33130EPM RubberVertical4351K520000000———06766T19000000
    0.1 gpm to 1 gpm8 7/16"6 7/16"±3%125 psi @ 70° F33130EPM RubberVertical4351K18000000———06766T1900000
    0.2 gpm to 2 gpm6 7/8"5"±4%125 psi @ 70° F33130EPM RubberVertical4351K16000000———06766T1900000
    0.2 gpm to 2 gpm8 7/16"6 7/16"±3%125 psi @ 70° F33130EPM RubberVertical4351K66000000———06766T1900000
    0.3 gpm to 3.5 gpm6 7/8"5"±4%125 psi @ 70° F33130EPM RubberVertical4351K17000000———06766T1900000
    0.5 gpm to 5 gpm6 7/8"5"±4%125 psi @ 70° F33130EPM RubberVertical4351K53000000———06766T1900000
    0.5 gpm to 5 gpm8 7/16"6 7/16"±3%125 psi @ 70° F33130EPM RubberVertical4351K67000000———06766T1900000
     
    1/2 NPT Female
    0.2 gpm to 2 gpm14 1/2"12 1/4"±2%125 psi @ 70° F33130EPM RubberVertical4351K68000000———06766T2200000
    0.35 gpm to 3.5 gpm14 1/2"12 1/4"±2%125 psi @ 70° F33130EPM RubberVertical4351K21000000———06766T2200000
    0.5 gpm to 5 gpm14 1/2"12 1/4"±2%125 psi @ 70° F33130EPM RubberVertical4351K690000003281K2300000006766T2200000
    1 gpm to 10 gpm14 1/2"12 1/4"±2%125 psi @ 70° F33130EPM RubberVertical4351K71000000———06766T2200000
     
    1 NPT Male
    1 gpm to 10 gpm9 1/8"6 1/2"±7%125 psi @ 70° F33130EPM RubberVertical4351K54000000———06766T2100000
    1.5 gpm to 15 gpm9 1/8"6 1/2"±7%125 psi @ 70° F33130EPM RubberVertical4351K19000000———06766T2100000
    2 gpm to 20 gpm9 1/8"6 1/2"±7%125 psi @ 70° F33130EPM RubberVertical4351K55000000———06766T2100000
     
    Acrylic Plastic Body with Brass Fittings
     
    1/4 NPT Female
    0.7 gph to 7 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K51000003281K210000006766T1800000
    1 gph to 12 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K1100000———06766T1800000
    2 gph to 22 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K1200000———06766T1800000
    2.2 gph to 22 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical———03281K220000006766T1800000
    4 gph to 44 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K1300000———06766T1800000
    6 gph to 60 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K1400000———06766T1800000
    7.5 gph to 75 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K1500000———06766T1800000
     
    Flowmeters with Flow-Control Knob
    Image of Product. Front orientation. Contains Annotated. Flowmeters. Panel-Mount Flowmeters, Flowmeters with Flow-Control Knob.
    Image of Product. Front orientation. Flowmeter Repair Kits. Panel-Mount Flowmeters.

    Replacement Flowmeter

    Repair Kits

    Flowmeters with a flow-control knob let you open and close the valve at the inlet to adjust the flow rate within the range.
    PVC Fitting—PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Brass Fitting—Brass fittings resist impact better than PVC fittings.
    303 Stainless Steel Fitting—303 stainless steel fittings resist impact better than PVC fittings.
    316 Stainless Steel Fitting—316 stainless steel fittings resist impact better than PVC fittings.
    1/4 NPT Threaded Female Pipe × 1/2 NPT Threaded Male Pipe—Flowmeters with a female × male connection have internal NPT female threads and external NPT male threads.
    Calibration Certificate Traceable to NIST—Flowmeters with a calibration certificate traceable to NIST states that the flowmeter has passed a test for accuracy.
    Flowmeters
    Replacement
    Flowmeter Repair Kits
    Temp.,
    ° F
    Flowmeters
    Calibration
    Certificate Traceable to NIST
    Flow
    Overall
    Ht.
    Ctr.-to-Ctr.
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Each
    Each
    Each
    Acrylic Plastic Body with PVC Fittings
     
    1/4 NPT Threaded Female Pipe × 1/2 NPT Threaded Male Pipe
    1 gph to 10 gph8 1/4"6 7/16"±3%150 psi @ 70° F33130EPM RubberVertical4351K3160000000———0———0
    2 gph to 20 gph8 1/4"6 7/16"±3%150 psi @ 70° F33130EPM RubberVertical4351K317000000———0———0
    4 gph to 40 gph8 1/4"6 7/16"±3%150 psi @ 70° F33130EPM RubberVertical4351K318000000———0———0
    0.1 gpm to 1 gpm6 7/8"5"±4%125 psi @ 70° F33130EPM RubberVertical4351K82000000———06766T24000000
    0.1 gpm to 1 gpm8 7/16"6 7/16"±3%125 psi @ 70° F33130EPM RubberVertical4351K38000000———06766T2400000
    10 gph to 100 gph8 1/4"6 7/16"±3%150 psi @ 70° F33130EPM RubberVertical4351K319000000———0———0
    0.2 gpm to 2 gpm6 7/8"5"±4%125 psi @ 70° F33130EPM RubberVertical4351K36000000———06766T2400000
    0.2 gpm to 2 gpm8 7/16"6 7/16"±3%125 psi @ 70° F33130EPM RubberVertical4351K86000000———06766T2400000
    0.3 gpm to 3.5 gpm6 7/8"5"±4%125 psi @ 70° F33130EPM RubberVertical4351K37000000———06766T2400000
    0.5 gpm to 5 gpm6 7/8"5"±4%125 psi @ 70° F33130EPM RubberVertical4351K83000000———06766T2400000
    0.5 gpm to 5 gpm8 7/16"6 7/16"±3%125 psi @ 70° F33130EPM RubberVertical4351K87000000———06766T2400000
     
    1/2 NPT Female
    0.2 gpm to 2 gpm14 1/2"12 1/4"±2%125 psi @ 70° F33130EPM RubberVertical4351K88000000———06766T2600000
    0.35 gpm to 3.5 gpm14 1/2"12 1/4"±2%125 psi @ 70° F33130EPM RubberVertical4351K41000000———06766T2600000
    0.5 gpm to 5 gpm14 1/2"12 1/4"±2%125 psi @ 70° F33130EPM RubberVertical4351K890000003281K3300000006766T2600000
    1 gpm to 10 gpm14 1/2"12 1/4"±2%125 psi @ 70° F33130EPM RubberVertical4351K91000000———06766T2600000
     
    1 NPT Female
    0.8 gpm to 5 gpm10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K115000000———0———0
    1.5 gpm to 10 gpm10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K36000000———0———0
    3 gpm to 20 gpm10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K38000000———0———0
    1 L/min to 19 L/min10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K116000000———0———0
    4 L/min to 36 L/min10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K117000000———0———0
    5 L/min to 75 L/min10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K118000000———0———0
     
    1 NPT Male
    1 gpm to 10 gpm9 1/8"6 1/2"±7%125 psi @ 70° F33130EPM RubberVertical4351K84000000———06766T2500000
    1.5 gpm to 15 gpm9 1/8"6 1/2"±7%125 psi @ 70° F33130EPM RubberVertical4351K39000000———06766T2500000
    2 gpm to 20 gpm9 1/8"6 1/2"±7%125 psi @ 70° F33130EPM RubberVertical4351K85000000———06766T2500000
     
    Acrylic Plastic Body with Brass Fittings
     
    1/8 NPT Female
    0.2 gph to 2 gph4"3"±5%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K10100000———0———0
    0.4 gph to 5 gph4"3"±5%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K10200000———0———0
    1 gph to 10 gph6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K103000000———0———0
    2 gph to 25 gph6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K104000000———0———0
    6 gph to 60 gph6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K105000000———0———0
    4 cm³/min to 50 cm³/min6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K106000000———0———0
    10 cm³/min to 120 cm³/min6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K107000000———0———0
    25 cm³/min to 225 cm³/min6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K108000000———0———0
    40 cm³/min to 400 cm³/min6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K109000000———0———0
    100 cm³/min to 1,500 cm³/min6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K111000000———0———0
    200 cm³/min to 3,000 cm³/min6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K112000000———0———0
    300 cm³/min to 3,700 cm³/min6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K113000000———0———0
     
    1/4 NPT Female
    0.7 gph to 7 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K810000003281K310000006766T2300000
    1 gph to 12 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K31000000———06766T2300000
    2 gph to 22 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K32000000———06766T2300000
    2.2 gph to 22 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical———03281K320000006766T2300000
    4 gph to 44 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K33000000———06766T2300000
    6 gph to 60 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K34000000———06766T2300000
    7.5 gph to 75 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K35000000———06766T2300000
    0.25 gpm to 2.5 gpm6 5/8"5 1/2"±3%100 psi @ 70° FNot Rated150Buna-N
    Vertical2968K114000000———0———0
     
    1/4 NPT Threaded Female Pipe × 1/2 NPT Threaded Male Pipe
    1 gph to 10 gph8 1/4"6 7/16"±3%150 psi @ 70° F33130EPM RubberVertical4351K301000000———0———0
    2 gph to 20 gph8 1/4"6 7/16"±3%150 psi @ 70° F33130EPM RubberVertical4351K302000000———0———0
    4 gph to 40 gph8 1/4"6 7/16"±3%150 psi @ 70° F33130EPM RubberVertical4351K303000000———0———0
    0.1 gpm to 1 gpm8 1/4"6 7/16"±3%150 psi @ 70° F33130EPM RubberVertical4351K305000000———0———0
    10 gph to 100 gph8 1/4"6 7/16"±3%150 psi @ 70° F33130EPM RubberVertical4351K304000000———0———0
    0.2 gpm to 2 gpm8 1/4"6 7/16"±3%150 psi @ 70° F33130EPM RubberVertical4351K306000000———0———0
    0.5 gpm to 5 gpm8 1/4"6 7/16"±3%150 psi @ 70° F33130EPM RubberVertical4351K307000000———0———0
     
    1/2 NPT Female
    0.2 gpm to 2 gpm14 1/4"12 1/4"±2%150 psi @ 70° F33130EPM RubberVertical4351K308000000———0———0
    0.3 gpm to 3.5 gpm14 1/4"12 1/4"±2%150 psi @ 70° F33130EPM RubberVertical4351K309000000———0———0
    0.5 gpm to 5 gpm14 1/4"12 1/4"±2%150 psi @ 70° F33130EPM RubberVertical4351K311000000———0———0
    1 gpm to 10 gpm14 1/4"12 1/4"±2%150 psi @ 70° F33130EPM RubberVertical4351K312000000———0———0
     
    1 NPT Male
    1 gpm to 10 gpm8 7/8"6 7/16"±4%150 psi @ 70° F33130EPM RubberVertical4351K313000000———0———0
    1.5 gpm to 15 gpm8 7/8"6 7/16"±7%150 psi @ 70° F33130EPM RubberVertical4351K314000000———0———0
    2 gpm to 20 gpm8 7/8"6 7/16"±7%150 psi @ 70° F33130EPM RubberVertical4351K315000000———0———0
     
    Acrylic Plastic Body with 303 Stainless Steel Fittings
     
    1/8 NPT Female
    0.2 gph to 2 gph4"3"±5%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K119000000———0———0
    0.4 gph to 5 gph4"3"±5%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K121000000———0———0
    1 gph to 10 gph6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K1220000002968K406000000———0
    2 gph to 25 gph6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K1230000002968K531000000———0
    6 gph to 60 gph6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K1240000002968K845000000———0
    4 cm³/min to 50 cm³/min6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K1250000002968K375000000———0
    10 cm³/min to 120 cm³/min6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K126000000———0———0
    25 cm³/min to 225 cm³/min6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K127000000———0———0
    40 cm³/min to 400 cm³/min6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K1280000002968K378000000———0
    100 cm³/min to 1,500 cm³/min6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K129000000———0———0
    200 cm³/min to 3,000 cm³/min6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K1310000002968K387000000———0
    300 cm³/min to 3,700 cm³/min6 1/2"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K132000000———0———0
     
    1/4 NPT Female
    0.25 gpm to 2.5 gpm6 5/8"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K31000000———0———0
    0.5 gpm to 5 gpm6 5/8"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K34000000———0———0
    1 L/min to 10 L/min6 5/8"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K1330000002968K352000000———0
    2 L/min to 20 L/min6 5/8"5 1/2"±3%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K1340000002968K357000000———0
     
    1 NPT Female
    0.6 gpm to 5 gpm10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical———02968K336000000———0
    0.8 gpm to 5 gpm10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K135000000———0———0
    1.5 gpm to 10 gpm10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K1360000002968K337000000———0
    3 gpm to 20 gpm10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K1370000002968K339000000———0
    1 L/min to 19 L/min10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K138000000———0———0
    4 L/min to 36 L/min10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K139000000———0———0
    5 L/min to 75 L/min10 7/8"8 1/2"±2%100 psi @ 70° FNot Rated150Fluoroelastomer
    Vertical2968K141000000———0———0
     
    Acrylic Plastic Body with 316 Stainless Steel Fittings
     
    1/4 NPT Female
    0.7 gph to 7 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K220000003281K410000006766T2300000
    1 gph to 12 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K23000000———06766T2300000
    2 gph to 22 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K24000000———06766T2300000
    2.2 gph to 22 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical———03281K420000006766T2300000
    4 gph to 44 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K25000000———06766T2300000
    6 gph to 60 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K26000000———06766T2300000
    7.5 gph to 75 gph4 1/8"3"±6%125 psi @ 70° F33130EPM RubberVertical4351K27000000———06766T2300000
     
    1/4 NPT Threaded Female Pipe × 1/2 NPT Threaded Male Pipe
    1 gph to 10 gph8 1/4"6 7/16"±3%150 psi @ 70° F33130EPM RubberVertical4351K321000000———0———0
    2 gph to 20 gph8 1/4"6 7/16"±3%150 psi @ 70° F33130EPM RubberVertical4351K322000000———0———0
    4 gph to 40 gph8 1/4"6 7/16"±3%150 psi @ 70° F33130EPM RubberVertical4351K323000000———0———0
    0.1 gpm to 1 gpm6 7/8"5"±4%125 psi @ 70° F33130EPM RubberVertical4351K44000000———06766T2400000
    0.1 gpm to 1 gpm8 7/16"6 7/16"±3%125 psi @ 70° F33130EPM RubberVertical4351K45000000———06766T2400000
    10 gph to 100 gph8 1/4"6 7/16"±3%150 psi @ 70° F33130EPM RubberVertical4351K324000000———0———0
    0.2 gpm to 2 gpm6 7/8"5"±4%125 psi @ 70° F33130EPM RubberVertical4351K46000000———06766T2400000
    0.2 gpm to 2 gpm8 7/16"6 7/16"±3%125 psi @ 70° F33130EPM RubberVertical4351K47000000———06766T2400000
    0.3 gpm to 3.5 gpm6 7/8"5"±4%125 psi @ 70° F33130EPM RubberVertical4351K48000000———06766T2400000
    0.5 gpm to 5 gpm6 7/8"5"±4%125 psi @ 70° F33130EPM RubberVertical4351K49000000———06766T2400000
    0.5 gpm to 5 gpm8 7/16"6 7/16"±3%125 psi @ 70° F33130EPM RubberVertical4351K61000000———06766T2400000
     
    1/2 NPT Female
    0.2 gpm to 2 gpm14 1/2"12 1/4"±2%125 psi @ 70° F33130EPM RubberVertical4351K28000000———06766T2600000
    0.35 gpm to 3.5 gpm14 1/2"12 1/4"±2%125 psi @ 70° F33130EPM RubberVertical4351K29000000———06766T2600000
    0.5 gpm to 5 gpm14 1/2"12 1/4"±2%125 psi @ 70° F33130EPM RubberVertical4351K420000003281K430000006766T2600000
    1 gpm to 10 gpm14 1/2"12 1/4"±2%125 psi @ 70° F33130EPM RubberVertical4351K43000000———06766T2600000
     
    1 NPT Male
    1 gpm to 10 gpm9 1/8"6 1/2"±7%125 psi @ 70° F33130EPM RubberVertical4351K62000000———06766T2500000
    1.5 gpm to 15 gpm9 1/8"6 1/2"±7%125 psi @ 70° F33130EPM RubberVertical4351K63000000———06766T2500000
    2 gpm to 20 gpm9 1/8"6 1/2"±7%125 psi @ 70° F33130EPM RubberVertical4351K64000000———06766T2500000
     

    Easy Read Flowmeters

    Image of Product. Style A. Front orientation. Style A. Easy Read Flowmeters.

    Style A

    Image of Specification. Style B—Left to Right. Front orientation. Left to Right. Easy Read Flowmeters, Bronze Body, Female, Style B.
    Image of Specification. Style B—Right to Left. Front orientation. Right to Left. Easy Read Flowmeters, Bronze Body, Female, Style B.

    Style B—Left to Right

    Style B—Right to Left

    Image of Specification. Style B—Bottom to Top. Front orientation. Bottom to Top. Easy Read Flowmeters, Bronze Body, Female, Style B.
    Image of Specification. Style B—Top to Bottom. Front orientation. Top to Bottom. Easy Read Flowmeters, Bronze Body, Female, Style B.

    Style B—Bottom to Top

    Style B—Top to

    Bottom

    A large dial instead of a scale makes it easier to read the flow rate from a distance. As liquid flows through these flowmeters, it pushes a needle along the dial, showing you the flow rate. They measure flow correctly no matter the mounting orientation.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Choose a direction of flow that matches your pipe system, so you don't have to tilt your head to read the dial.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    PVC Fitting—PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Aluminum Fitting—Aluminum fittings resist impact better than PVC fittings.
    Brass Fitting—Brass fittings resist impact better than PVC fittings.
    Bronze Fitting—Bronze fittings resist impact better than PVC fittings.
    316 Stainless Steel Fitting—316 stainless steel fittings resist impact better than PVC fittings.
    Style B—Style B flowmeters should be installed away from other fittings to get the most accurate reading. To determine how far away from the fittings it should be, take your pipe's diameter and multiply it by 10.
    Temp.,
    ° F
    Style
    Flow,
    gpm
    Dial
    Size
    End-to-End
    Lg.
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Choose a Direction of Flow
    Each
    PVC Body with PVC Fittings
     
    1/4 NPT Female
    A0 to 12 1/2"3 5/8"3 5/16"±2%200 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9079T210000000
    A0 to 13 1/2"3 5/8"4 3/8"±2%200 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9079T28000000
    A0 to 22 1/2"3 5/8"3 5/16"±2%200 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9079T27000000
    A0 to 23 1/2"3 5/8"4 3/8"±2%200 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9079T29000000
     
    1/2 NPT Female
    A0 to 52 1/2"5 3/4"3 5/16"±2%200 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9858K371000000
    A0 to 102 1/2"5 3/4"3 5/16"±2%200 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9079T36000000
    A0 to 103 1/2"5 3/4"4 3/8"±2%200 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9079T38000000
     
    1 NPT Female
    A0 to 203 1/2"3 1/4"5 13/16"±2%100 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9858K171000000
    A0 to 403 1/2"3 1/4"5 13/16"±2%100 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9858K172000000
     
    2 NPT Female
    A0 to 603 1/2"3 1/4"7 1/16"±2%100 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9858K18100000000
    A0 to 1003 1/2"3 1/4"7 1/16"±2%100 psi @ 70° F32140Viton® Fluoroelastomer
    Any AngleLeft to Right9858K18200000000
     
    Aluminum Body with Aluminum Fittings
     
    1/4 NPT Female
    A0 to 12 1/2"3 5/8"2 15/16"±2%3,000 psi @ 70° F33150Buna-N
    Any AngleLeft to Right41995K41000000
    A0 to 14 1/2"3 5/8"5 1/4"±2%3,000 psi @ 70° F33150Buna-N
    Any AngleLeft to Right41995K71000000
    A0 to 22 1/2"3 5/8"2 15/16"±2%3,000 psi @ 70° F33150Buna-N
    Any AngleLeft to Right41995K42000000
    A0 to 24 1/2"3 5/8"5 1/4"±2%3,000 psi @ 70° F33150Buna-N
    Any AngleLeft to Right41995K72000000
     
    1/2 NPT Female
    A0 to 52 1/2"5 3/4"2 15/16"±2%3,000 psi @ 70° F33150Buna-N
    Any AngleLeft to Right41995K43000000
    A0 to 54 1/2"5 3/4"5 1/4"±2%3,000 psi @ 70° F33150Buna-N
    Any AngleLeft to Right41995K73000000
    A0 to 102 1/2"5 3/4"2 15/16"±2%3,000 psi @ 70° F33150Buna-N
    Any AngleLeft to Right41995K44000000
    A0 to 104 1/2"5 3/4"5 1/4"±2%3,000 psi @ 70° F33150Buna-N
    Any AngleLeft to Right41995K74000000
     
    1 NPT Female
    A0 to 203 1/2"3 1/4"5 3/4"±2%500 psi @ 70° F-20200Buna-N
    Any AngleLeft to Right9858K271000000
    A0 to 403 1/2"3 1/4"5 3/4"±2%500 psi @ 70° F-20200Buna-N
    Any AngleLeft to Right9858K272000000
     
    2 NPT Female
    A0 to 603 1/2"3 1/4"7"±2%500 psi @ 70° F-20200Buna-N
    Any AngleLeft to Right9858K281000000
    A0 to 1003 1/2"3 1/4"7"±2%500 psi @ 70° F-20200Buna-N
    Any AngleLeft to Right9858K282000000
     
    Brass Body with Brass Fittings
     
    1/4 NPT Female
    A0 to 12 1/2"3 5/8"2 15/16"±2%3,000 psi @ 70° F33150Buna-N
    Any AngleLeft to Right41995K51000000
    A0 to 14 1/2"3 5/8"5 1/4"±2%3,000 psi @ 70° F33150Buna-N
    Any AngleLeft to Right41995K81000000
    A0 to 22 1/2"3 5/8"2 15/16"±2%3,000 psi @ 70° F33150Buna-N
    Any AngleLeft to Right41995K52000000
    A0 to 24 1/2"3 5/8"5 1/4"±2%3,000 psi @ 70° F33150Buna-N
    Any AngleLeft to Right41995K82000000
     
    1/2 NPT Female
    A0 to 52 1/2"5 3/4"2 15/16"±2%3,000 psi @ 70° F33150Buna-N
    Any AngleLeft to Right41995K53000000
    A0 to 54 1/2"5 3/4"5 1/4"±2%3,000 psi @ 70° F33150Buna-N
    Any AngleLeft to Right41995K83000000
    A0 to 102 1/2"5 3/4"2 15/16"±2%3,000 psi @ 70° F33150Buna-N
    Any AngleLeft to Right41995K54000000
    A0 to 104 1/2"5 3/4"5 1/4"±2%3,000 psi @ 70° F33150Buna-N
    Any AngleLeft to Right41995K84000000
     
    Bronze Body with Bronze Fittings
     
    1/2 NPT Female
    B0.5 to 43 1/2"4 9/16"6 11/16"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom9858K51000000
    B0.5 to 63 1/2"4 9/16"6 11/16"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom9858K92000000
     
    3/4 NPT Female
    B1.5 to 103 1/2"4 9/16"6 11/16"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom9858K52000000
    B2 to 153 1/2"4 9/16"6 11/16"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom9858K93000000
     
    1 NPT Female
    B3 to 203 1/2"4 9/16"6 15/16"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom9858K53000000
    B4 to 303 1/2"4 9/16"6 15/16"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom9858K94000000
     
    1 1/2 NPT Female
    B5 to 603 1/2"4 9/16"7 5/8"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom9858K54000000
    B15 to 1003 1/2"4 9/16"7 5/8"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom9858K95000000
     
    2 NPT Female
    B15 to 1003 1/2"4 9/16"8 3/8"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom9858K5500000000
    B30 to 2003 1/2"4 9/16"8 3/8"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom9858K5600000000
     
    3 NPT Female
    B40 to 3003 1/2"9 13/16"9 13/16"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom9858K5700000000
     
    316 Stainless Steel Body with 316 Stainless Steel Fittings
     
    1/4 NPT Female
    A0 to 12 1/2"3 5/8"2 15/16"±2%3,000 psi @ 70° F33150Fluoroelastomer
    Any AngleLeft to Right41995K61000000
    A0 to 14 1/2"3 5/8"5 1/4"±2%3,000 psi @ 70° F33150Fluoroelastomer
    Any AngleLeft to Right41995K91000000
    A0 to 22 1/2"3 5/8"2 15/16"±2%3,000 psi @ 70° F33150Fluoroelastomer
    Any AngleLeft to Right41995K62000000
    A0 to 24 1/2"3 5/8"5 1/4"±2%3,000 psi @ 70° F33150Fluoroelastomer
    Any AngleLeft to Right41995K92000000
     
    1/2 NPT Female
    A0 to 52 1/2"5 3/4"2 15/16"±2%3,000 psi @ 70° F33150Fluoroelastomer
    Any AngleLeft to Right41995K63000000
    A0 to 54 1/2"5 3/4"5 1/4"±2%3,000 psi @ 70° F33150Fluoroelastomer
    Any AngleLeft to Right41995K93000000
    A0 to 102 1/2"5 3/4"2 15/16"±2%3,000 psi @ 70° F33150Fluoroelastomer
    Any AngleLeft to Right41995K64000000
    A0 to 104 1/2"5 3/4"5 1/4"±2%3,000 psi @ 70° F33150Fluoroelastomer
    Any AngleLeft to Right41995K94000000
     

    Any-Orientation Flowmeters

    Image of Product. Front orientation. Flowmeters. Any-Orientation Flowmeters, Female.
    Image of Product. Front orientation. Flowmeters. Any-Orientation Flowmeters, Male.

    Female

    Male

    A spring piston instead of a float allows these flowmeters to measure flow rate in any mounting orientation. As liquid passes through, it pushes an indicator up the scale, showing you the flow rate. They have union fittings on both ends, making it easy to position the scale so it’s visible.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Choose a fitting material that is compatible with the liquid you intend to run through your line.
    Polysulfone Fitting—Polysulfone fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Brass Fitting—Brass fittings resist impact better than polysulfone fittings.
    Temp.,
    ° F
    Flow,
    gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Features
    Each
    Polycarbonate Body with Polysulfone Fittings
     
    1/2 NPT Female
    0.5 to 57 3/16"±2%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A610000000
    1 to 107 9/16"±2%325 psi @ 70° F-20200Fluoroelastomer
    Any AngleUnion Fittings4161A221000000
    1 to 157 9/16"±2%325 psi @ 70° F-20200Fluoroelastomer
    Any AngleUnion Fittings4161A222000000
     
    1/2 BSPP Female
    0.5 to 57 9/16"±2%325 psi @ 70° F-20200Fluoroelastomer
    Any AngleUnion Fittings4161A231000000
    1 to 157 9/16"±2%325 psi @ 70° F-20200Fluoroelastomer
    Any AngleUnion Fittings4161A232000000
     
    3/4 NPT Female
    0.5 to 57 9/16"±2%325 psi @ 70° F-20200Fluoroelastomer
    Any AngleUnion Fittings4161A223000000
    1 to 107 9/16"±2%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A63000000
    1 to 157 9/16"±2%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A64000000
    3 to 307 9/16"±2%325 psi @ 70° F-20200Fluoroelastomer
    Any AngleUnion Fittings4161A224000000
    Any-Orientation Flowmeter, Polysulfone Fittings, 3/4 NPT Female, 3-30 gpm
    EachIn stock
     
    3/4 BSPP Female
    0.5 to 57 9/16"±2%325 psi @ 70° F-20200Fluoroelastomer
    Any AngleUnion Fittings4161A233000000
    1 to 157 9/16"±2%325 psi @ 70° F-20200Fluoroelastomer
    Any AngleUnion Fittings4161A234000000
    3 to 307 9/16"±2%325 psi @ 70° F-20200Fluoroelastomer
    Any AngleUnion Fittings4161A235000000
     
    1 NPT Female
    0.5 to 57 9/16"±2%325 psi @ 70° F-20200Fluoroelastomer
    Any AngleUnion Fittings4161A225000000
    1 to 107 9/16"±2%325 psi @ 70° F-20200Fluoroelastomer
    Any AngleUnion Fittings4161A226000000
    1 to 157 9/16"±2%325 psi @ 70° F-20200Fluoroelastomer
    Any AngleUnion Fittings4161A227000000
    3 to 307 9/16"±2%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A66000000
     
    1 BSPP Female
    0.5 to 57 9/16"±2%325 psi @ 70° F-20200Fluoroelastomer
    Any AngleUnion Fittings4161A236000000
    1 to 157 9/16"±2%325 psi @ 70° F-20200Fluoroelastomer
    Any AngleUnion Fittings4161A237000000
    3 to 307 9/16"±2%325 psi @ 70° F-20200Fluoroelastomer
    Any AngleUnion Fittings4161A238000000
     
    Polysulfone Body with Polysulfone Fittings
     
    1 NPTF Male
    0.5 to 45 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K11000000
    1 to 75 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K12000000
    1 to 105 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K13000000
    1 to 165 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K14000000
    3 to 185 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K15000000
    4 to 285 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K16000000
     
    Polycarbonate Body with Brass Fittings
     
    1/2 NPTF Female
    0.5 to 57 3/16"±2%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A41000000
    1 to 107 3/16"±2%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A42000000
     
    3/4 NPT Female
    1 to 107 9/16"±2%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A43000000
    1 to 157 9/16"±2%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A44000000
     
    1 NPT Female
    0.5 to 57 9/16"±2%325 psi @ 70° F-20200Fluoroelastomer
    Any AngleUnion Fittings4161A228000000
    1 to 157 9/16"±2%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A45000000
    3 to 307 9/16"±2%325 psi @ 70° F-20200Fluoroelastomer
    Any AngleUnion Fittings4161A46000000
     
    Polysulfone Body with Brass Fittings
     
    1/2 NPTF Female
    0.5 to 47 3/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K21000000
    1 to 77 3/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K22000000
    1 to 107 3/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K23000000
    1 to 167 3/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K24000000
     
    3/4 NPTF Male
    0.5 to 48 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K31000000
    1 to 108 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K28000000
    1 to 168 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K25000000
    4 to 288 1/4"±5%325 psi @ 70° F33200Buna-N
    Any Angle4197K27000000
     
    1 1/2 NPTF Female
    2 to 258 13/16"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K621000000
    5 to 508 13/16"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K622000000
    7 to 758 13/16"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K623000000
    10 to 1008 13/16"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K624000000
     
    2 NPTF Female
    2 to 258 13/16"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K631000000
    5 to 508 13/16"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K632000000
    7 to 758 13/16"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K633000000
    10 to 1008 13/16"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K634000000
     
    2 1/2 NPTF Female
    20 to 20010 3/4"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K64100000000
     
    3 NPTF Female
    25 to 27510 3/4"±5%325 psi @ 70° F33250Buna-N
    Any Angle4197K65100000000
     

    Flowmeters for Gases

    Image of Product. Front orientation. Flowmeters. Flowmeters for Gases, Female.
    Image of Product. Front orientation. Flowmeters. Flowmeters for Gases, Male.
    Image of Product. Front orientation. Flowmeter Repair Kits. Flowmeters for Gases.

    Female

    Male

    Replacement

    Flowmeter Repair

    Kits

    Designed for air and other gases, these flowmeters measure the rate at which they're moving through your pipes. As your gas passes through these flowmeters, it pushes an indicator up the scale, showing you the flow rate. Mount them vertically inline with your pipe system, so gas flows up from the bottom. They’re made from acrylic, so they’re completely clear to help you inspect your gas’s color and clarity for any problems.
    These flowmeters are calibrated with air but can be used with other gases. If you’re using these with a gas other than air, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your gas.
    Choose a fitting material that is compatible with the gas you're running through your line.
    PVC Fitting—PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Brass Fitting—Brass fittings resist impact better than PVC fittings.
    316 Stainless Steel Fitting—316 stainless steel fittings resist impact better than PVC fittings.
    Flowmeters
    Replacement
    Flowmeter Repair Kits
    Temp.,
    ° F
    Flow
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Each
    Each
    Acrylic Plastic Body with PVC Fittings
     
    1/4 NPT Male
    0.26 scfh to 2.6 scfh4 3/4"±6%125 psi @ 70° F33100EPM Rubber8051K201000000———0
    0.5 scfh to 5 scfh4 3/4"±6%125 psi @ 70° F33100EPM Rubber8051K20200000———0
    1 scfh to 10 scfh4 3/4"±6%125 psi @ 70° F33100EPM Rubber8051K20300000———0
    2 scfh to 20 scfh4 3/4"±6%125 psi @ 70° F33100EPM Rubber8051K20400000———0
    3 scfh to 30 scfh4 3/4"±6%125 psi @ 70° F33100EPM Rubber8051K20500000———0
    7 scfh to 70 scfh4 3/4"±6%125 psi @ 70° F33100EPM Rubber8051K31000006766T14000000
    10 scfh to 100 scfh4 3/4"±6%125 psi @ 70° F33100EPM Rubber8051K32000006766T1400000
    18 scfh to 180 scfh4 3/4"±6%125 psi @ 70° F33100EPM Rubber8051K33000006766T1400000
    0.4 scfm to 4 scfm4 3/4"±6%125 psi @ 70° F33100EPM Rubber8051K34000006766T1400000
     
    1/2 NPT Female
    0.4 scfm to 4 scfm6 1/2"±5%125 psi @ 70° F33100EPM Rubber8051K20600000———0
    0.8 scfm to 8 scfm6 1/2"±5%125 psi @ 70° F33100EPM Rubber8051K21000006766T1700000
    0.82 scfm to 8.2 scfm9 1/4"±3%125 psi @ 70° F33100EPM Rubber8051K230000006766T1700000
    1.5 scfm to 15 scfm6 1/2"±5%125 psi @ 70° F33100EPM Rubber8051K20700000———0
    2 scfm to 20 scfm6 1/2"±5%125 psi @ 70° F33100EPM Rubber8051K22000006766T1700000
    2.1 scfm to 21 scfm9 1/4"±3%125 psi @ 70° F33100EPM Rubber8051K240000006766T1700000
     
    3/4 NPT Female
    0.8 scfm to 8 scfm14 13/16"±2%125 psi @ 70° F33100EPM Rubber8051K208000000———0
    1.48 scfm to 14.8 scfm14 13/16"±2%125 psi @ 70° F33100EPM Rubber8051K209000000———0
    2 scfm to 20 scfm14 13/16"±2%125 psi @ 70° F33100EPM Rubber8051K370000006766T1600000
    4.2 scfm to 42 scfm14 13/16"±2%125 psi @ 70° F33100EPM Rubber8051K380000006766T1600000
     
    1 NPT Female
    4 scfm to 40 scfm8 3/8"±4%125 psi @ 70° F33100EPM Rubber8051K350000006766T1500000
    6 scfm to 60 scfm8 3/8"±4%125 psi @ 70° F33100EPM Rubber8051K360000006766T1500000
     
    Acrylic Plastic Body with Brass Fittings
     
    1/4 NPT Female
    6 scfh to 70 scfh4 3/4"±6%125 psi @ 70° F33100EPM Rubber8051K22400000———0
    10 scfh to 180 scfh4 3/4"±6%125 psi @ 70° F33100EPM Rubber8051K22500000———0
    0.4 scfm to 4 scfm4 3/4"±6%125 psi @ 70° F33100EPM Rubber8051K22600000———0
     
    1/2 NPT Female
    0.8 scfm to 8 scfm6 1/2"±5%125 psi @ 70° F33100EPM Rubber8051K227000000———0
    2 scfm to 20 scfm6 1/2"±5%125 psi @ 70° F33100EPM Rubber8051K228000000———0
     
    3/4 NPT Female
    1.48 scfm to 14.8 scfm14 13/16"±2%125 psi @ 70° F33100EPM Rubber8051K229000000———0
    4.2 scfm to 42 scfm14 13/16"±2%125 psi @ 70° F33100EPM Rubber8051K231000000———0
     
    1 NPT Female
    6 scfm to 60 scfm8 3/8"±4%125 psi @ 70° F33100EPM Rubber8051K232000000———0
     
    Acrylic Plastic Body with 316 Stainless Steel Fittings
     
    1/4 NPT Female
    0.5 scfh to 5 scfh4 3/4"±6%125 psi @ 70° F33100EPM Rubber8051K211000000———0
    2 scfh to 20 scfh4 3/4"±6%125 psi @ 70° F33100EPM Rubber8051K212000000———0
    6 scfh to 70 scfh4 3/4"±6%125 psi @ 70° F33100EPM Rubber8051K213000000———0
    10 scfh to 180 scfh4 3/4"±6%125 psi @ 70° F33100EPM Rubber8051K214000000———0
    0.4 scfm to 4 scfm4 3/4"±6%125 psi @ 70° F33100EPM Rubber8051K215000000———0
     
    1/2 NPT Female
    0.4 scfm to 4 scfm6 1/2"±5%125 psi @ 70° F33100EPM Rubber8051K216000000———0
    0.8 scfm to 8 scfm6 1/2"±5%125 psi @ 70° F33100EPM Rubber8051K217000000———0
    0.82 scfm to 8.2 scfm9 1/4"±3%125 psi @ 70° F33100EPM Rubber8051K550000006766T1700000
    1.5 scfm to 15 scfm6 1/2"±5%125 psi @ 70° F33100EPM Rubber8051K520000006766T1700000
    2 scfm to 20 scfm6 1/2"±5%125 psi @ 70° F33100EPM Rubber8051K218000000———0
     
    3/4 NPT Female
    1.48 scfm to 14.8 scfm14 13/16"±2%125 psi @ 70° F33100EPM Rubber8051K219000000———0
    4.2 scfm to 42 scfm14 13/16"±2%125 psi @ 70° F33100EPM Rubber8051K221000000———0
     
    1 NPT Female
    4 scfm to 40 scfm8 3/8"±4%125 psi @ 70° F33100EPM Rubber8051K222000000———0
    6 scfm to 60 scfm8 3/8"±4%125 psi @ 70° F33100EPM Rubber8051K223000000———0
     

    Flowmeter/Totalizers

    Determine the flow rate and total volume of liquid flowing through your system with the same meter. To measure flow, these flowmeter/totalizers count how many times their turbine turns as liquid passes through. Use them only with clean, low-viscosity liquids to avoid clogging the turbine and other damage to these flowmeter/totalizers. You can reset the batch total, but you can’t reset the cumulative total. Mount them inline with your pipe system. They’re accurate in any mounting orientation.
    These flowmeter/totalizers are either calibrated with water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Choose a fitting material that is compatible with the liquid you're running through your line. IP rated, all seal out dust and can be lightly rinsed.
    PVC Body with PVC Fittings and 316 Stainless Steel Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, PVC Body.
    Image of Product. Shown with 90° Display Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers, PVC Body.

    Shown with 90°

    Display Adapter Kit

    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flowmeter/Totalizers.

    Replacement Displays

    Image of Product. Front orientation. Flowmeter Rotors. Flowmeter/Totalizers.

    Replacement Flowmeter Rotors

    PVC fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    NEMA 4 Enclosure Rating—NEMA 4 flowmeter/totalizers protect against weather and washdowns.
    Flowmeter/Totalizers
    Replacement Displays
    Replacement
    Flowmeter Rotors
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Each
    Display
    Type
    Each
    Each
    Flowmeter/Totalizers
    1/2 NPT Female1 to 1080
    6"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T3110000000Digital4352K5130000000———0
    3/4 NPT Female2 to 2080
    6 1/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T321000000Digital4352K523000000———0
    1 NPT Female5 to 5080
    6 1/2"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T331000000Digital4352K533000000———0
    1 1/2 NPT Female10 to 10080
    7 5/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T341000000Digital4352K543000000———0
    2 NPT Female20 to 20080
    7 7/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T351000000Digital4352K553000000———0
    4 NPT Female60 to 60080
    17"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T42100000000Digital4352K1090000004352K1120000000
     
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    1/2 NPT Female1 to 1080
    6"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T431000000Digital4352K513000000———0
    3/4 NPT Female2 to 2080
    6 1/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T441000000Digital4352K523000000———0
    1 NPT Female5 to 5080
    6 1/2"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T451000000Digital4352K533000000———0
    1 1/2 NPT Female10 to 10080
    7 5/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T461000000Digital4352K543000000———0
    2 NPT Female20 to 20080
    7 7/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T471000000Digital4352K553000000———0
    4 NPT Female60 to 60080
    17"±3%999,999 Gallons999,999 Gallons225 psi @ 70° F33140YesIP65
    NEMA 4
    2400T49100000000Digital4352K1090000004352K112000000
     
    Accessories for Flowmeters
    Nylon Body with Nylon Fittings and 316 Stainless Steel Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, Nylon Body, Nylon Fitting.
    Image of Product. Shown with 90° Display Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers, Nylon Body, Nylon Fitting.

    Shown with 90°

    Display Adapter Kit

    Nylon fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    NEMA 4 Enclosure Rating—NEMA 4 flowmeter/totalizers protect against weather and washdowns.
    FM Approved—FM-approved flowmeter/totalizers are safe for use in hazardous location.
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    Flowmeter/Totalizers
    1 NPT Female0.3 to 380
    4"±1.5%999,999 Gallons999,999 Gallons150 psi @ 70° F14140YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx Ia IIC T4
    FM Approved
    4352K6320000000
     
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    1 NPT Female0.3 to 380
    4"±1.5%999,999 Gallons999,999 Gallons150 psi @ 70° F14140YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    AEx Ia IIC T4
    FM Approved
    4352K232000000
     
    Accessories for Flowmeters
    PVDF Body with PVDF Fittings and Fluoroelastomer Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, PVDF Body.
    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flowmeter/Totalizers.

    Replacement Displays

    Image of Product. Front orientation. Flowmeter Rotors. Flowmeter/Totalizers.

    Replacement Flowmeter Rotors

    PVDF fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    NEMA 4 Enclosure Rating—NEMA 4 flowmeter/totalizers protect against weather and washdowns.
    FM Approved—FM-approved flowmeter/totalizers are safe for use in hazardous location.
    Flowmeter/Totalizers
    Replacement Displays
    Replacement
    Flowmeter Rotors
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    Display
    Type
    Each
    Each
    Flowmeter/Totalizers
    1/2 NPT Female1.2 to 1280
    7 5/16"±2%999,999 Gallons999,999 Gallons100 psi @ 70° F0125YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    AEx Ia IIC T4
    FM Approved
    4352K102000000000Digital4352K51300000004352K1040000000
    1 NPT Female5 to 5080
    8 1/16"±1.5%999,999 Gallons999,999 Gallons100 psi @ 70° F0125YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    AEx Ia IIC T4
    FM Approved
    4352K10500000000Digital4352K5330000004352K107000000
     
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    1/2 NPT Female1.2 to 1280
    7 5/16"±2%999,999 Gallons999,999 Gallons100 psi @ 70° F0125YesIP65
    NEMA 4
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    AEx Ia IIC T4
    FM Approved
    4352K10300000000Digital4352K5130000004352K104000000
     
    Accessories for Flowmeters
    316 Stainless Steel Body with 316 Stainless Steel Fittings and 316 Stainless Steel Seal
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers, 316 Stainless Steel Body.
    Image of Product. Shown with 90° Display Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers, 316 Stainless Steel Body.
    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flowmeter/Totalizers.

    Shown with 90°

    Display Adapter Kit

    Replacement Displays

    316 stainless steel fittings resist impact better than plastic fittings.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    FM Approved—FM-approved flowmeter/totalizers are safe for use in hazardous location.
    Flowmeter/Totalizers
    Replacement Displays
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Batteries
    Included
    Enclosure
    Rating
    Hazardous Location Rating
    Certification
    Each
    Display
    Type
    Each
    Flowmeter/Totalizers
    1/2 NPT Female1 to 104 1/4"±1.5%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K5120000000Digital4352K5130000000
    3/4 NPT Female2 to 204 3/8"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K522000000Digital4352K523000000
    1 NPT Female5 to 504 1/2"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K532000000Digital4352K533000000
    1 1/2 NPT Female10 to 1005 3/8"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K54200000000Digital4352K543000000
    2 NPT Female20 to 2006 3/8"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K55200000000Digital4352K553000000
     
    Flowmeter/Totalizers with Calibration Certificate Traceable to NIST
    1/2 NPT Female1 to 104 1/4"±1.5%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K85200000000Digital4352K513000000
    3/4 NPT Female2 to 204 3/8"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K86200000000Digital4352K523000000
    1 NPT Female5 to 504 1/2"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K87200000000Digital4352K533000000
    1 1/2 NPT Female10 to 1005 3/8"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K88200000000Digital4352K543000000
    2 NPT Female20 to 2006 3/8"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140YesIP65
    NEC Class I Divisions 1, 2
    Groups A, B, C, D
    NEC Class II Divisions 1, 2
    Groups E, F, G
    NEC Class III Divisions 1, 2
    ATEX II 1 G Ex Ia IIC T4 Ga
    IECEx Ex Ia IIC T4 Ga
    FM Approved
    CE Marked
    C-FM Approved
    4352K89200000000Digital4352K553000000
     
    Accessories for Flowmeters

    Easy-Read Flowmeters for Gases

    Instead of a scale, these flowmeters have a large dial that makes it easy to read the flow rate of your gas from a distance. As gas flows through, it pushes a needle along the dial, showing you the flow rate.
    These flowmeters are calibrated with air but can be used with other gases. If you’re using these with a gas other than air, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your gas.
    Aluminum Body
    Image of Product. Front orientation. Flowmeters. Easy-Read Flowmeters for Gases, Aluminum Body, Female.

    Female

    Temp.,
    ° F
    2 1/2" Dial Size
    4 1/2" Dial Size
    Flow,
    scfm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Direction
    of Flow
    Each
    Each
    1/4 NPT Female
    1.5 to 103 5/8"±5%3,000 psi @ 70° F-22150Buna-N
    Any AngleAny Direction9909K1100000009909K310000000
    2 to 153 5/8"±5%3,000 psi @ 70° F-22150Buna-N
    Any AngleAny Direction9909K120000009909K32000000
    3 to 203 5/8"±5%3,000 psi @ 70° F-22150Buna-N
    Any AngleAny Direction9909K130000009909K33000000
    3 to 253 5/8"±5%3,000 psi @ 70° F-22150Buna-N
    Any AngleAny Direction9909K140000009909K34000000
     
    1/2 NPT Female
    5 to 505 3/4"±5%3,000 psi @ 70° F-22150Buna-N
    Any AngleAny Direction9909K150000009909K35000000
    10 to 1005 3/4"±5%3,000 psi @ 70° F-22150Buna-N
    Any AngleAny Direction9909K160000009909K36000000
     
    Bronze Body with Bronze Fittings
    Image of Specification. Front orientation. Left to Right. Easy-Read Flowmeters for Gases, Bronze Body, Female.
    Image of Specification. Front orientation. Right to Left. Easy-Read Flowmeters for Gases, Bronze Body, Female.
    Image of Specification. Front orientation. Bottom to Top. Easy-Read Flowmeters for Gases, Bronze Body, Female.
    Image of Specification. Front orientation. Top to Bottom. Easy-Read Flowmeters for Gases, Bronze Body, Female.

    Female

    Left to Right

    Female

    Right to Left

    Female

    Bottom to Top

    Female

    Top to Bottom

    Flowmeters with a bronze body should be installed away from other fittings to get the most accurate reading. To determine how far away from the fittings it should be, take your pipe's diameter and multiply it by 10. Choose a direction of flow that matches your pipe system, so you don't have to tilt your head to read the dial.
    Temp.,
    ° F
    3 1/2" Dial Size
    Flow, scfm
    End-to-End
    Lg.
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Choose a Direction of Flow
    Each
    1/4 NPT Female
    3 to 204 9/16"6 11/16"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom42005K380000000
     
    1/2 NPT Female
    5 to 404 9/16"6 11/16"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom42005K31000000
     
    3/4 NPT Female
    20 to 1504 9/16"6 11/16"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom42005K3200000000
     
    1 NPT Female
    40 to 3004 9/16"6 15/16"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom42005K3300000000
     
    1 1/2 NPT Female
    50 to 6004 9/16"7 5/8"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom42005K3400000000
     
    2 NPT Female
    100 to 8004 9/16"8 3/8"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom42005K3500000000
    150 to 1,0004 9/16"8 3/8"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom42005K3600000000
     
    3 NPT Female
    300 to 2,0004 9/16"9 13/16"±3%180 psi @ 70° F-30212Buna-N
    Any AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom42005K3700000000
     

    High-Temperature and Pressure Flowmeters for Oil

    Image of Product. Front orientation. Flowmeters. High-Temperature and Pressure Flowmeters for Oil.
    If the oil in your line is too hot or pressurized for standard flowmeters, use these flowmeters to measure the flow rate. As oil flows through, it pushes an indicator up the scale, showing you the flow rate. The scale rotates 360°, so you can check the flow rate from any angle. These flowmeters measure flow correctly in any mounting orientation. Install them inline with your pipe system.
    These flowmeters are calibrated with oil but can be used with other liquids. If you’re using these with a liquid other than oil, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Choose a fitting material that is compatible with the oil you're running through your line.
    Pipe
    Size
    Flow, gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min. Temp.,
    ° F
    Body Material
    Seal Material
    Mounting
    Position
    Features
    Each
    NPT Female Pipe Connection
     
    Aluminum Fitting—240° F Maximum Temperature
    1/2
    0.2 to 26 5/8"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N110000000
    3/4
    0.2 to 27 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N12000000
    3/4
    0.5 to 57 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N13000000
    1
    0.2 to 27 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N14000000
    1
    0.5 to 57 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N15000000
    1
    5 to 507 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N16000000
    1 1/2
    5 to 5012 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N1700000000
    1 1/2
    10 to 10012 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N1800000000
     
    Aluminum Fitting—400° F Maximum Temperature
    1/4
    0.2 to 26 5/8"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N39000000
    1/2
    0.5 to 56 5/8"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N41000000
    1/2
    1 to 156 5/8"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N42000000
    3/4
    3 to 307 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N43000000
    1
    5 to 507 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N44000000
     
    303 Stainless Steel Fitting—240° F Maximum Temperature
    1/4
    0.05 to 0.54 13/16"±7%6,000 psi @ 70° F-20303 Stainless Steel
    Fluoroelastomer
    Any AngleRotating Scale5067N19000000
    1/4
    0.2 to 24 13/16"±7%6,000 psi @ 70° F-20303 Stainless Steel
    Fluoroelastomer
    Any AngleRotating Scale5067N21000000
    1/2
    0.5 to 56 5/8"±2%6,000 psi @ 70° F-20303 Stainless Steel
    Fluoroelastomer
    Any AngleRotating Scale5067N22000000
    1/2
    1 to 156 5/8"±2%6,000 psi @ 70° F-20303 Stainless Steel
    Fluoroelastomer
    Any AngleRotating Scale5067N23000000
    3/4
    0.5 to 57 1/4"±2%5,000 psi @ 70° F-20303 Stainless Steel
    Fluoroelastomer
    Any AngleRotating Scale5067N2400000000
    3/4
    1 to 107 1/4"±2%5,000 psi @ 70° F-20303 Stainless Steel
    Fluoroelastomer
    Any AngleRotating Scale5067N2500000000
    3/4
    3 to 307 1/4"±2%5,000 psi @ 70° F-20303 Stainless Steel
    Fluoroelastomer
    Any AngleRotating Scale5067N2600000000
    1
    0.5 to 57 1/4"±2%5,000 psi @ 70° F-20303 Stainless Steel
    Fluoroelastomer
    Any AngleRotating Scale5067N2700000000
    1
    2 to 207 1/4"±2%5,000 psi @ 70° F-20303 Stainless Steel
    Fluoroelastomer
    Any AngleRotating Scale5067N2800000000
    1
    4 to 407 1/4"±2%5,000 psi @ 70° F-20303 Stainless Steel
    Fluoroelastomer
    Any AngleRotating Scale5067N2900000000
     
    NPTF Female Pipe Connection
     
    Aluminum Fitting—240° F Maximum Temperature
    1/4
    0.02 to 0.24 13/16"±7%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K16000000
    1/4
    0.05 to 0.54 13/16"±7%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K25000000
    1/4
    0.1 to 14 13/16"±7%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K41000000
    1/4
    0.2 to 24 13/16"±7%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K14000000
    1/2
    0.1 to 16 5/8"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K15000000
    1/2
    0.5 to 56 5/8"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K81000000
    1/2
    1 to 106 5/8"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K12000000
    1/2
    1 to 156 5/8"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K83000000
    3/4
    1 to 107 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K84000000
    3/4
    2 to 207 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K85000000
    3/4
    3 to 307 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K87000000
    1
    1 to 107 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K42000000
    1
    2 to 207 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K43000000
    1
    3 to 307 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K44000000
    1
    4 to 407 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K23000000
    1 1/4
    5 to 5012 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K6100000000
    1 1/4
    10 to 10012 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K6400000000
     
    Aluminum Fitting—400° F Maximum Temperature
    3/4
    0.5 to 57 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale42145K53000000
    3/4
    1 to 107 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale42145K54000000
    1
    1 to 107 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale42145K55000000
    1
    3 to 307 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale42145K56000000
    1 1/2
    10 to 10012 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale42145K5700000000
     
    UN/UNF (SAE Straight) Female Pipe Connection
     
    Aluminum Fitting—240° F Maximum Temperature
    1/4
    0.05 to 0.54 13/16"±7%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N31000000
    1/4
    0.2 to 24 13/16"±7%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N32000000
    1/2
    0.2 to 26 5/8"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N33000000
    1/2
    1 to 106 5/8"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N34000000
    3/4
    0.5 to 57 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N35000000
    3/4
    2 to 207 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N36000000
    1
    1 to 107 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N37000000
    1
    4 to 407 1/4"±2%3,500 psi @ 70° F-20Aluminum
    Fluoroelastomer
    Any AngleRotating Scale5067N38000000
     

    High-Temperature and Pressure Flowmeters

    Image of Product. Front orientation. Flowmeters. High-Temperature and Pressure Flowmeters.
    With a maximum temperature of 240° F and a maximum pressure of 3,500 psi, these flowmeters measure the flow rate of liquids that are too hot or pressurized for standard flowmeters. As your liquid flows through, it pushes an indicator up the scale, showing you the flow rate. They measure flow correctly in any mounting orientation. Install them inline with your pipe system. They have brass fittings that resist impact better than plastic fittings.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Temp.,
    ° F
    Flow, gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Each
    Brass Body with Brass Fittings
     
    1/4 NPTF Female
    0.02 to 0.24 13/16"±7%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K410000000
    0.05 to 0.54 13/16"±7%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K42000000
    0.1 to 14 13/16"±7%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K24000000
    0.2 to 24 13/16"±7%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K25000000
     
    1/2 NPTF Female
    0.2 to 26 5/8"±2%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K31000000
    0.5 to 56 5/8"±2%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K81000000
    1 to 156 5/8"±2%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K93000000
     
    3/4 NPTF Female
    0.5 to 57 1/4"±2%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K32000000
    1 to 107 1/4"±2%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K33000000
    2 to 207 1/4"±2%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K95000000
    3 to 307 1/4"±2%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K86000000
     
    1 NPTF Female
    2 to 207 1/4"±2%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K43000000
    3 to 307 1/4"±2%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K44000000
    5 to 507 1/4"±2%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K45000000
     
    1 1/4 NPTF Female
    5 to 5012 1/4"±2%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K7800000000
    10 to 10012 1/4"±2%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K8800000000
    10 to 15012 1/4"±2%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K2900000000
     
    1 1/2 NPTF Female
    10 to 10012 1/4"±2%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K4600000000
    10 to 15012 1/4"±2%3,500 psi @ 70° F-20240Fluoroelastomer
    Any Angle4230K4700000000
     

    Impact-Resistant Panel-Mount Flowmeters for Gases

    Image of Product. Front orientation. Contains Annotated. Flowmeters. Impact-Resistant Panel-Mount Flowmeters for Gases, Polycarbonate Body, Female, Flowmeters.
    Image of Product. Front orientation. Contains Annotated. Flowmeters. Impact-Resistant Panel-Mount Flowmeters for Gases, Polycarbonate Body, Female, Flowmeters with Flow-Control Knob.
    Image of Product. Front orientation. Contains Annotated. Flowmeters. Impact-Resistant Panel-Mount Flowmeters for Gases, Glass Body, Female, Flowmeters with Flow-Control Knob.

    Polycarbonate

    Body, Female,

    Flowmeters

    Polycarbonate

    Body, Female,

    Flowmeters with

    Flow-Control Knob

    Glass Body,

    Female, Flowmeters

    with Flow-Control

    Knob

    A case protects these flowmeters from blows and other impact as they measure the flow rate of gas. Install them in instrument panels using the fittings on the back. As your gas flows through, it pushes an indicator up the scale, showing you the flow rate. Mount these flowmeters vertically, so gas flows up from the bottom.
    These flowmeters are calibrated with air but can be used with other gases. If you’re using these with a gas other than air, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your gas.
    Choose a fitting material that is compatible with the gas you're running through your line.
    Flow-Control Knob—Flowmeters with a flow-control knob let you open and close the inlet valve to adjust the flow rate within the range.
    Temp.,
    ° F
    Flowmeters
    Flowmeters with
    Flow-Control Knob
    Flow, scfh
    Overall
    Ht.
    Ctr.-to-Ctr.
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Case Material
    Mounting
    Position
    Each
    Each
    Polycarbonate Body with 303 Stainless Steel Fittings
     
    1/8 NPT Female
    0.1 to 14 13/16"3"±4%100 psi @ 70° FNot Rated150Fluoroelastomer
    Polycarbonate
    Vertical5079K220000005079K620000000
    0.2 to 2.54 13/16"3"±4%100 psi @ 70° FNot Rated150Fluoroelastomer
    Polycarbonate
    Vertical5079K23000005079K63000000
    0.4 to 54 13/16"3"±4%100 psi @ 70° FNot Rated150Fluoroelastomer
    Polycarbonate
    Vertical5079K24000005079K64000000
    1 to 114 13/16"3"±4%100 psi @ 70° FNot Rated150Fluoroelastomer
    Polycarbonate
    Vertical5079K25000005079K65000000
    2 to 224 13/16"3"±4%100 psi @ 70° FNot Rated150Fluoroelastomer
    Polycarbonate
    Vertical5079K26000005079K66000000
    4 to 604 13/16"3"±4%100 psi @ 70° FNot Rated150Fluoroelastomer
    Polycarbonate
    Vertical5079K27000005079K67000000
    10 to 1004 13/16"3"±4%100 psi @ 70° FNot Rated150Fluoroelastomer
    Polycarbonate
    Vertical———05079K68000000
    20 to 2004 13/16"3"±4%100 psi @ 70° FNot Rated150Fluoroelastomer
    Polycarbonate
    Vertical———05079K59000000
     
    Glass Body with 316L Stainless Steel Fittings
     
    1/4 NPT Female
    0.04 to 0.426 1/16"4 9/16"±6%200 psi @ 70° F33250Fluoroelastomer
    304 Stainless Steel
    Vertical———05084K19000000
    0.4 to 46 1/16"4 9/16"±6%200 psi @ 70° F33250Fluoroelastomer
    304 Stainless Steel
    Vertical———05084K22000000
    0.82 to 8.26 1/16"4 9/16"±6%200 psi @ 70° F33250Fluoroelastomer
    304 Stainless Steel
    Vertical———05084K33000000
    1 to 286 1/16"4 9/16"±6%200 psi @ 70° F33250Fluoroelastomer
    304 Stainless Steel
    Vertical———05084K55000000
    5 to 906 1/16"4 9/16"±6%200 psi @ 70° F33250Fluoroelastomer
    304 Stainless Steel
    Vertical———05084K77000000
     

    Panel-Mount Flowmeters for Gases with Conversion Chart

    Image of Product. Front orientation. Contains Annotated. Flowmeters. Panel-Mount Flowmeters for Gases with Conversion Chart.
    Instead of a scale calibrated to a specific gas’ flow rate, these flowmeters measure in millimeters and include a conversion chart, so you can check the flow rate of water and multiple gases without any calculations. Install them in an instrument panel using the fittings on the back. They should be mounted vertically inline with your pipe system, so your gas flows up from the bottom. As gas flows through, it pushes an indicator up the scale. The flow control knob lets you open and close the inlet valve to adjust the flow rate within the range.
    The conversion chart includes the flow rates for air, argon, carbon dioxide, helium, nitrogen, oxygen, and water. To calculate the flow rate of gases not included on the chart, multiply the flow rate for air by the specific-gravity conversion factor of your gas. Because you’re using gas, you’ll also need to account for temperature and pressure.
    Choose a fitting material that is compatible with the gas you're running through your line.
    Flow—To help you determine what measuring range is best, flow is given for air.
    Temp.
    Distance Measured,
    mm
    Flow,
    cm³/min
    Overall
    Ht.
    Ctr.-to-Ctr.
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.,
    ° F
    Seal Material
    Case
    Material
    Window
    Material
    Mounting
    Position
    Features
    Each
    Glass Body with 316 Stainless Steel Fittings
     
    1/8 NPT Female
    0 to 650 to 505 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale4112K920000000
    0 to 650 to 1035 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale4112K94000000
    0 to 650 to 4005 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale4112K96000000
    0 to 650 to 9005 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-18.2 ccm)4112K74000000
    0 to 650 to 2,5805 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-55 ccm)4112K75000000
    0 to 650 to 3,8405 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-90 ccm)4112K76000000
    0 to 650 to 6,0005 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-130 ccm)4112K77000000
    0 to 650 to 10,1005 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-235 ccm)4112K78000000
    0 to 650 to 15,7505 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-375 ccm)4112K79000000
    0 to 650 to 23,6405 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-570 ccm)4112K81000000
    0 to 1500 to 5010"8 7/8"±3%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale4112K98000000
    0 to 1500 to 10310"8 7/8"±3%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale4112K831000000
    0 to 1500 to 40010"8 7/8"±3%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale4112K841000000
    0 to 1500 to 85510"8 7/8"±3%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-18 ccm)4112K85000000
    0 to 1500 to 2,29010"8 7/8"±3%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-50 ccm)4112K86000000
    0 to 1500 to 3,42510"8 7/8"±3%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-75 ccm)4112K87000000
    0 to 1500 to 9,18010"8 7/8"±3%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-215 ccm)4112K88000000
    0 to 1500 to 23,74010"8 7/8"±3%200 psi @ 70° FNot Rated200Fluoroelastomer
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-565 ccm)4112K89000000
     
    Glass Body with Aluminum Fittings
     
    1/8 NPT Female
    0 to 650 to 505 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale4112K91000000
    0 to 650 to 1035 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale4112K93000000
    0 to 650 to 4005 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale4112K95000000
    0 to 650 to 9005 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-18.2 ccm)4112K34000000
    0 to 650 to 2,5805 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-55 ccm)4112K35000000
    0 to 650 to 3,8405 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-90 ccm)4112K36000000
    0 to 650 to 6,0005 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-130 ccm)4112K37000000
    0 to 650 to 10,1005 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-235 ccm)4112K38000000
    0 to 650 to 15,7505 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-375 ccm)4112K39000000
    0 to 650 to 23,6405 1/2"4 1/2"±5%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-570 ccm)4112K41000000
    0 to 1500 to 5010"8 7/8"±3%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale4112K97000000
    0 to 1500 to 10310"8 7/8"±3%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale4112K431000000
    0 to 1500 to 40010"8 7/8"±3%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale4112K441000000
    0 to 1500 to 85510"8 7/8"±3%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-18 ccm)4112K45000000
    0 to 1500 to 2,29010"8 7/8"±3%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-50 ccm)4112K46000000
    0 to 1500 to 3,42510"8 7/8"±3%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-75 ccm)4112K47000000
    0 to 1500 to 9,18010"8 7/8"±3%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-215 ccm)4112K48000000
    0 to 1500 to 23,74010"8 7/8"±3%200 psi @ 70° FNot Rated200Buna-N
    Aluminum
    Polycarbonate
    VerticalFlow-Control Knob, Rotating Scale, Water Flow Scale (0-565 ccm)4112K49000000
     

    High-Temperature Flowmeters

    Image of Product. Front orientation. Flowmeters. High-Temperature Flowmeters, Female.
    Image of Product. Front orientation. Flowmeters. High-Temperature Flowmeters, Male.

    Female

    Male

    Measure the flow rate of high-temperature liquids. As your liquid flows through these flowmeters, it pushes an indicator up the scale, showing you the flow rate. Mount them vertically inline with your piping system, so liquid flows up from the bottom. They have union fittings, making it easy to position the scale so it’s visible. The fittings are plastic, so they work with a wide range of chemicals.
    These flowmeters are calibrated using water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Flow
    Temp.,
    ° F
    US Customary,
    gpm
    Metric,
    L/min
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Features
    Each
    Polysulfone Body with Polypropylene Fittings
     
    3/8 NPT Male
    0.1 to 10.4 to 46 3/16"±4%175 psi @ 70° F-10212Fluoroelastomer
    VerticalUnion Fittings4400K670000000
    0.2 to 20.75 to 7.56 3/16"±4%175 psi @ 70° F-10212Fluoroelastomer
    VerticalUnion Fittings4400K68000000
     
    Polysulfone Body with Polysulfone Fittings
     
    3/8 NPT Male
    0.5 to 51.8 to 186 3/16"±4%175 psi @ 70° F-10212Fluoroelastomer
    VerticalUnion Fittings4400K74000000
     
    1/2 NPT Male
    0.1 to 10.4 to 46 3/16"±4%175 psi @ 70° F-10212Fluoroelastomer
    VerticalUnion Fittings4400K72000000
    0.2 to 20.75 to 7.56 3/16"±4%175 psi @ 70° F-10212Fluoroelastomer
    VerticalUnion Fittings4400K73000000
    0.5 to 51.8 to 186 3/16"±4%175 psi @ 70° F-10212Fluoroelastomer
    VerticalUnion Fittings4400K69000000
    1 to 105 to 37.57 1/2"±4%175 psi @ 70° F-10212Fluoroelastomer
    VerticalUnion Fittings4400K66000000
     
    3/4 NPT Male
    1 to 105 to 37.57 1/2"±4%175 psi @ 70° F-10212Fluoroelastomer
    VerticalUnion Fittings4400K71000000
     
    1 NPT Female
    0.5 to 62 to 2214 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K131000000
    1 to 104 to 4014 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K132000000
    2 to 206 to 7614 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K54000000
    3 to 3010 to 11014 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K55000000
    4 to 4015 to 15514 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K56000000
     
    2 NPT Female
    2 to 208 to 7818 7/8"±2%150 psi @ 70° F33200Fluoroelastomer
    VerticalUnion Fittings4400K14100000000
    6 to 10020 to 38018 7/8"±2%150 psi @ 70° F33200Fluoroelastomer
    VerticalUnion Fittings4400K5900000000
    20 to 13080 to 50018 7/8"±2%150 psi @ 70° F33200Fluoroelastomer
    VerticalUnion Fittings4400K6100000000
     
    Polysulfone Body with PVC Fittings
     
    1 1/2 NPT Female
    0.5 to 62 to 2214 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K151000000
    1 to 104 to 4014 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K152000000
    2 to 206 to 7614 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K153000000
    3 to 3023 to 11514 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K154000000
    4 to 4015 to 15514 1/2"±3%150 psi @ 70° F33212Fluoroelastomer
    VerticalUnion Fittings4400K155000000
     

    Variable-Pressure Flowmeters for Gases

    Image of Product. Front orientation. Flowmeters. Variable-Pressure Flowmeters for Gases, Aluminum Body, Female, Flowmeters.
    Image of Product. Front orientation. Flowmeters. Variable-Pressure Flowmeters for Gases, Aluminum Body, Female, Flowmeters with Pressure Gauge.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Rotating Scale. Variable-Pressure Flowmeters for Gases.

    Aluminum Body

    Female

    Flowmeters

    Aluminum Body, Female,

    Flowmeters with

    Pressure Gauge

    Rotating Scale

    Measure the flow rate of gases in applications where pressure fluctuates, such as compressed air systems. These flowmeters have a scale with multiple pressures, so can see your flow rate without having to convert to your system's pressure. As air flows through the meter, it pushes the indicator on the scale. The scale rotates 360°, so you can check the flow rate from any angle. Install these flowmeters directly inline with your pipeline using the fittings on each end. They measure flow rate correctly no matter the mounting orientation.
    These flowmeters are calibrated with air but can be used with other gases. If you’re using these with a gas other than air, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your gas.
    Pressure Gauge—Flowmeters with a pressure gauge directly measure pressure as gas flows through the meter, letting you confirm the current pressure with the flow rate on the scale.
    Flowmeters
    Flowmeters with Pressure Gauge
    Temp.,
    ° F
    Pressure Gauge
    Flow,
    scfm
    Accuracy
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Features
    End-to-End
    Lg.
    Max. Pressure
    @ Temp.
    Each
    End-to-End
    Lg.
    Measurement,
    psi
    Dial
    Size
    Max. Pressure
    @ Temp.
    Each
    Aluminum Body with Aluminum Fittings
     
    1/4 NPTF Female
    0.5 to 5±5%-20240Fluoroelastomer
    Any AngleRotating Scale4 13/16"1,000 psi @ 70° F4216K1200000006 1/8"0 to 1602 1/2"600 psi @ 70° F4216K110000000
    1 to 10±5%-20240Fluoroelastomer
    Any AngleRotating Scale4 13/16"1,000 psi @ 70° F4216K140000006 1/8"0 to 1602 1/2"600 psi @ 70° F4216K13000000
    2 to 20±5%-20240Fluoroelastomer
    Any AngleRotating Scale4 13/16"1,000 psi @ 70° F4216K420000006 1/8"0 to 1602 1/2"600 psi @ 70° F4216K22000000
    3 to 30±5%-20240Fluoroelastomer
    Any AngleRotating Scale4 13/16"1,000 psi @ 70° F4216K160000006 1/8"0 to 1602 1/2"600 psi @ 70° F4216K15000000
     
    1/2 NPTF Female
    3 to 25±2%-20240Fluoroelastomer
    Any AngleRotating Scale6 5/8"1,000 psi @ 70° F4216K410000008"0 to 1602 1/2"600 psi @ 70° F4216K43000000
    5 to 50±2%-20240Fluoroelastomer
    Any AngleRotating Scale6 5/8"1,000 psi @ 70° F4216K530000008"0 to 1602 1/2"600 psi @ 70° F4216K23000000
    10 to 100±2%-20240Fluoroelastomer
    Any AngleRotating Scale6 5/8"1,000 psi @ 70° F4216K540000008"0 to 1602 1/2"600 psi @ 70° F4216K24000000
    15 to 150±2%-20240Fluoroelastomer
    Any AngleRotating Scale6 5/8"1,000 psi @ 70° F4216K550000008"0 to 1602 1/2"600 psi @ 70° F4216K25000000
     
    3/4 NPTF Female
    5 to 50±2%-20240Fluoroelastomer
    Any AngleRotating Scale7 1/4"1,000 psi @ 70° F4216K560000008 15/16"0 to 1602 1/2"600 psi @ 70° F4216K26000000
    10 to 100±2%-20240Fluoroelastomer
    Any AngleRotating Scale7 1/4"1,000 psi @ 70° F4216K340000008 15/16"0 to 1602 1/2"600 psi @ 70° F4216K33000000
    15 to 150±2%-20240Fluoroelastomer
    Any AngleRotating Scale7 1/4"1,000 psi @ 70° F4216K770000008 15/16"0 to 1602 1/2"600 psi @ 70° F4216K27000000
    25 to 250±2%-20240Fluoroelastomer
    Any AngleRotating Scale7 1/4"1,000 psi @ 70° F4216K780000008 15/16"0 to 1602 1/2"600 psi @ 70° F4216K28000000
     
    1 NPTF Female
    15 to 150±2%-20240Fluoroelastomer
    Any AngleRotating Scale7 1/4"1,000 psi @ 70° F4216K810000008 15/16"0 to 1602 1/2"600 psi @ 70° F4216K91000000
    25 to 250±2%-20240Fluoroelastomer
    Any AngleRotating Scale7 1/4"1,000 psi @ 70° F4216K820000008 15/16"0 to 1602 1/2"600 psi @ 70° F4216K92000000
     
    1 1/2 NPTF Female
    40 to 400±2%-20240Fluoroelastomer
    Any AngleRotating Scale12 1/4"1,000 psi @ 70° F4216K830000000013 13/16"0 to 1602 1/2"600 psi @ 70° F4216K9300000000
     

    Insertion Flowmeters

    Image of ProductInUse. Front orientation. Flowmeters. Insertion Flowmeters.
    No need to disassemble your PVC pipeline—insert these flowmeters into a drilled hole and secure them using the included clamps. As liquid flows through the meter, it pushes an indicator up the scale, showing you the flow rate. They have a clear body, so you can check the color and clarity of flowing liquid to identify and diagnose problems. Mount these flowmeters vertically.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Flow for Pipe
    Schedule, gpm
    Temp.,
    ° F
    Pipe
    Size
    Schedule
    40
    Schedule
    80
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Each
    Acrylic Plastic Body with 316 Stainless Steel Fittings
    1
    5 to 354 to 266"±5%75 psi @ 70° F33190Neoprene
    Vertical4349K110000000
    1 1/4
    9 to 508 to 406"±5%75 psi @ 70° F33190Neoprene
    Vertical4349K2000000
    1 1/2
    10 to 7010 to 606"±5%75 psi @ 70° F33190Neoprene
    Vertical4349K33000000
    2
    20 to 12018 to 1006"±5%75 psi @ 70° F33190Neoprene
    Vertical4349K34000000
    3
    45 to 24040 to 2156"±10%75 psi @ 70° F33190Neoprene
    Vertical4349K61000000
    4
    75 to 42070 to 3756"±10%75 psi @ 70° F33190Neoprene
    Vertical4349K7000000
     

    Impact-Resistant Panel-Mount Flowmeters

    Image of Product. Front orientation. Contains Annotated. Flowmeters. Impact-Resistant Panel-Mount Flowmeters, Polycarbonate Body, Female, Flowmeters.
    Image of Product. Front orientation. Contains Annotated. Flowmeters. Impact-Resistant Panel-Mount Flowmeters, Polycarbonate Body, Female, Flowmeters with Flow-Control Knob.
    Image of Product. Front orientation. Contains Annotated. Flowmeters. Impact-Resistant Panel-Mount Flowmeters, Glass Body, Female, Flowmeters with Flow-Control Knob.

    Polycarbonate Body

    Female

    Flowmeters

    Polycarbonate Body,

    Female, Flowmeters

    with Flow-Control

    Knob

    Glass Body, Female,

    Flowmeters with

    Flow-Control Knob

    Install these flowmeters in an instrument panel where they might be exposed to blows and other impact. They have a case that protects them from cracking or shattering. Using the fittings on the back, these flowmeters mount vertically inline with your pipe system, so liquid flows up from the bottom. As liquid flows through the meter, it pushes an indicator up the scale, showing you the flow rate.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    303 Stainless Steel Fitting—Flowmeters with 303 stainless steel fittings are also calibrated with air.
    Flow-Control Knob—Flowmeters with a flow-control knob let you open and close the inlet valve to adjust the flow rate within the range.
    Temp.,
    ° F
    Flowmeters
    Flowmeters with
    Flow-Control Knob
    Flow, gph
    Overall
    Ht.
    Ctr.-to-Ctr.
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Case Material
    Mounting
    Position
    Each
    Each
    Polycarbonate Body with 303 Stainless Steel Fittings
     
    1/8 NPT Female
    0.2 to 2.54 13/16"3"±4%100 psi @ 70° FNot Rated150Fluoroelastomer
    Polycarbonate
    Vertical5079K120000005079K520000000
    0.4 to 54 13/16"3"±4%100 psi @ 70° FNot Rated150Fluoroelastomer
    Polycarbonate
    Vertical5079K15000005079K53000000
    1 to 104 13/16"3"±4%100 psi @ 70° FNot Rated150Fluoroelastomer
    Polycarbonate
    Vertical5079K16000005079K54000000
    2 to 254 13/16"3"±4%100 psi @ 70° FNot Rated150Fluoroelastomer
    Polycarbonate
    Vertical5079K17000005079K55000000
    4 to 404 13/16"3"±4%100 psi @ 70° FNot Rated150Fluoroelastomer
    Polycarbonate
    Vertical5079K18000005079K56000000
     
    Glass Body with 316 Stainless Steel Fittings
     
    1/4 NPT Female
    0.1 to 2.66 1/16"4 9/16"±6%200 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Vertical———05084K83000000
    0.15 to 1.756 1/16"4 9/16"±6%200 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Vertical———05084K81000000
    0.8 to 8.26 1/16"4 9/16"±6%200 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Vertical———05084K87000000
    1 to 196 1/16"4 9/16"±6%200 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Vertical———05084K89000000
     

    Flowmeters for Oxygen

    Image of Product. Front orientation. Flowmeters. Flowmeters for Oxygen.
    To prevent contaminating your oxygen line, these flowmeters are specially cleaned and bagged. As oxygen flows through, it pushes an indicator up the scale, showing you the flow rate. Mount these flowmeters vertically inline with your oxygen system, so oxygen flows up from the bottom. The flow-control knob lets you open and close the valve at the inlet to adjust the flow rate within the range.
    These flowmeters are calibrated with oxygen but can be used with other gases. If you’re using these with a gas other than oxygen, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your gas.
    Cannot Be Sold to Canada—Flowmeters cannot be sold to Canada due to import regulations.
    Temp.,
    ° F
    Flow,
    L/min
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Features
    Cannot Be
    Sold To
    Each
    Polycarbonate Body with Brass Fittings
     
    1/8 NPT Threaded Female Pipe Inlet × Barbed Male Tube Outlet For 1/4" Tube ID
    0 to 307 1/4"±10%50 psi @ 70° F-40140Fluoroelastomer
    VerticalFlow-Control KnobCanada3505K2110000000
    0.25 to 3.57 1/4"±10%150 psi @ 72° F-40140Fluoroelastomer
    VerticalFlow-Control KnobCanada3505K34000000
    0.5 to 87 1/4"±10%150 psi @ 72° F-40140Fluoroelastomer
    VerticalFlow-Control KnobCanada3505K35000000
    0.5 to 157 1/4"±10%150 psi @ 72° F-40140Fluoroelastomer
    VerticalFlow-Control KnobCanada3505K36000000
     
    1/4 NPT Threaded Female Pipe Inlet × Barbed Male Tube Outlet For 1/4" Tube ID
    0 to 3.57 1/4"±10%50 psi @ 70° F-40140Fluoroelastomer
    VerticalFlow-Control KnobCanada3505K212000000
    0 to 87 1/4"±10%50 psi @ 70° F-40140Fluoroelastomer
    VerticalFlow-Control KnobCanada3505K213000000
    0 to 157 1/4"±10%50 psi @ 70° F-40140Fluoroelastomer
    VerticalFlow-Control KnobCanada3505K214000000
    0 to 307 1/4"±10%50 psi @ 70° F-40140Fluoroelastomer
    VerticalFlow-Control KnobCanada3505K215000000
    0 to 707 1/4"±10%50 psi @ 70° F-40140Fluoroelastomer
    VerticalFlow-Control KnobCanada3505K216000000
     

    High-Temperature Flowmeters with Digital Display

    Image of Product. Front orientation. Flowmeters. High-Temperature Flowmeters with Digital Display.
    Check the flow rate of liquids up to 200° F from an easy-to-read digital display instead of a scale or dial. These flowmeters measure flow by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to these flowmeters, use them only with clean, low-viscosity liquids. Mount them inline with your pipe system. Their fittings are polypropylene, which works with a wide range of chemicals. NEMA and IP rated, these flowmeters stand up to dust, weather, corrosion, and water from washdowns.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Temp.,
    ° F
    Flow,
    gpm
    End-to-End
    Lg.
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Batteries
    Included
    Enclosure
    Rating
    Each
    Polypropylene Body with Polypropylene Fittings
     
    3/8 NPT Male
    0.4 to 44 3/4"5 3/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K170000000
    0.8 to 84 3/4"5 3/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K11000000
     
    1/2 NPT Male
    2 to 205 1/8"5 3/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K12000000
     
    3/4 NPT Male
    3 to 305 1/4"5 5/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K13000000
     
    1 NPT Male
    5 to 505 5/8"5 5/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K14000000
     
    1 1/2 NPT Male
    6 to 606 1/2"6 1/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K15000000
     
    2 NPT Male
    10 to 1006 3/4"6 3/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K16000000
    20 to 2006 3/4"6 3/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleYesIP56
    NEMA 4X
    3562K18000000
     
    Replacements for Flowmeters

    Flanged Totalizers for Drinking Water

    Image of Product. Front orientation. Flowmeters. Flanged Totalizers for Drinking Water, Bronze Body, Elliptical Flange.
    Image of Product. Front orientation. Flowmeters. Flanged Totalizers for Drinking Water, Bronze Body, Round Flange.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Analog Display. Flanged Totalizers for Drinking Water, Bronze Body.

    Bronze Body

    Elliptical Flange

    Bronze Body

    Round Flange

    Bronze Body

    Analog Display

    Flanged ends let you securely integrate these totalizers into large drinking water pipelines to measure the cumulative amount of water flowing through them. They meet NSF/ANSI 61, so they're safe to use with drinking water. They measure flow volume by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. Their total cannot be reset.
    These totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Flanges—The elliptical flange kit (sold separately) lets you convert elliptical flanges to NPT female connections.
    Totalizers
    Flanges
    Flange
    Temp.,
    ° F
    Bolt
    Connections
    OD
    Type
    Flow, gpm
    Maximum Total Volume
    Displayed
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Display
    Type
    Hole
    Dia.
    Circle
    Dia.
    No. of
    Holes
    Each
    Each
    Bronze Body with Brass Fittings
    2 Pipe Size
    5 7/8"Elliptical4 to 35099,999,000 Gallons10"±1.5%175 psi @ 70° F33150Buna-N
    HorizontalAnalog5/8"4"24189K310000000004189K410000000
    3 Pipe Size
    7 1/2"Round5 to 53099,999,000 Gallons12"±1.5%175 psi @ 70° F33150Buna-N
    HorizontalAnalog3/4"6"44189K3200000000———0
    4 Pipe Size
    8 7/8"Round9 to 1,35099,999,000 Gallons14"±1.5%175 psi @ 70° F33150Buna-N
    HorizontalAnalog3/4"7 1/2"84189K3300000000———0
    6 Pipe Size
    11 1/8"Round25 to 2,70099,999,000 Gallons18"±1.5%175 psi @ 70° F33150Buna-N
    HorizontalAnalog7/8"9 1/2"84189K3400000000———0
     

    Portable Noncontact Flowmeters

    Image of ProductInUse. Front orientation. Contains MultipleImages. Flowmeters. Portable Noncontact Flowmeters.
    Image of Product. Front orientation. Contains MultipleImages. Flowmeters. Portable Noncontact Flowmeters.
    Often used to pinpoint flow issues, these flowmeters clamp onto pipe, so you can spot-check the flow rate at different points without disassembling your system. They measure by tracking the time it takes for ultrasonic waves to pass through your liquid, so they don’t need to come into contact with your liquid. As a result, they can be used with a wider range of liquids than other flowmeters.
    Flow for Pipe
    Size, gpm
    Temp.,
    ° F
    For Pipe
    Size
    1/2
    2
    4
    12
    28
    Speed,
    ft/sec
    Overall
    Ht.
    Accuracy
    Min.
    Max.
    Batteries
    Included
    Display
    Type
    Includes
    Each
    Polycarbonate Body
    1/2 to 40.2 to 304 to 55015 to 2,0000.03 to 1003 15/16"±1.0%-20320YesDigitalCarrying Case, Mounting Hardware, Optional Power Source and Cable, Ultrasonic Gel4416N11000000000
    1/2 to 280.2 to 304 to 55015 to 2,000130 to 18,000700 to 100,0000.03 to 1003 15/16"±1.0%-20320YesDigitalCarrying Case, Mounting Hardware, Optional Power Source and Cable, Ultrasonic Gel4416N1300000000
    2 to 284 to 55015 to 2,000130 to 18,000700 to 100,0000.03 to 1003 15/16"±1.0%-20320YesDigitalCarrying Case, Mounting Hardware, Optional Power Source and Cable, Ultrasonic Gel4416N1200000000
     
    Replacement Ultrasonic Gel

    Flowmeter/Totalizers for Oil and Fuel

    Image of ProductInUse. Shown with 90° Display
Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers for Oil and Fuel.

    Shown with 90°

    Display Adapter Kit

    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers for Oil and Fuel.
    Image of Product. Front orientation. Flowmeter Displays. Flowmeter/Totalizers for Oil and Fuel, Flowmeter/Totalizers, Digital Display.

    Replacement Displays

    Image of Product. Front orientation. Flowmeter Rotors. Flowmeter/Totalizers for Oil and Fuel.

    Replacement Flowmeter

    Rotors

    Use these flowmeter/totalizers to measure both the flow rate and total flow volume of oil, gasoline, diesel fuel, and kerosene. They count how many times their turbine turns as liquid passes through them to measure flow. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. You can reset the batch total, but you can't reset the cumulative total. Mount them directly inline with your piping system. They measure flow correctly no matter the mounting orientation. Rated NEMA 4 and IP65, they seal out dust and protect against washdowns.
    These flowmeter/totalizers are calibrated with either water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    Flowmeter/Totalizers
    Replacement Displays
    Replacement
    Flowmeter Rotors
    Flowmeter/Totalizers
    Flowmeter/Totalizers with Calibration
    Certificate Traceable to NIST
    Max. Volume
    Displayed
    Temp., ° F
    Temp., ° F
    Connections
    Flow,
    gpm
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Enclosure
    Rating
    Min.
    Max.
    Each
    Min.
    Max.
    Each
    Display
    Type
    Each
    Each
    Turbine Flow Measurement
     
    Aluminum Body with Aluminum Fitting and 316 Stainless Steel Seal
    1/2 NPT Female1 to 104 3/16"±2%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    01254352K201000000001254352K202000000000Digital4352K51300000004352K6650000000
    3/4 NPT Female2 to 204 5/16"±1.5%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    01254352K20300000001254352K20400000000Digital4352K5230000004352K666000000
    1 NPT Female0.3 to 34"±5%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    141404352K672000000141404352K912000000———0———0
    1 NPT Female3 to 504"±1.5%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    141404352K682000000141404352K922000000———0———0
    1 1/2 NPT Female10 to 1005 5/16"±1%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    01254352K2050000000001254352K20600000000Digital4352K5430000004352K668000000
    2 NPT Female20 to 2006"±0.75%999,999 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP65
    NEMA 4
    -402504352K4100000000141404352K4200000000Digital4352K4000000———0
     
    Accessories for Flowmeters

    Clog-Resistant Flowmeters

    Image of Product. Horizontal Flow with Female Connections. Front orientation. Flowmeters. Clog-Resistant Flowmeters, Brass Body, Female.
    Image of Product. Vertical Flow with Female Connections. Front orientation. Flowmeters. Clog-Resistant Flowmeters, Brass Body, Female.
    Image of Product. Horizontal Flow with Male Connections. Front orientation. Flowmeters. Clog-Resistant Flowmeters, Brass Body, Male.
    Image of Product. Vertical Flow with Male Connections. Front orientation. Flowmeters. Clog-Resistant Flowmeters, Brass Body, Male.

    Horizontal Flow with

    Female Connections

    Vertical Flow

    with Female

    Connections

    Horizontal Flow with Male Connections

    Vertical Flow

    with Male

    Connections

    Liquids with particles up to 1/8" in diameter won't clog this flowmeter. As your liquid flows through, it pushes an indicator up the scale, showing you the flow rate. They have fittings on both ends to install them inline with your piping system.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Temp.,
    ° F
    Flow,
    gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Choose a Direction of Flow
    Each
    Brass Body with Brass Fittings
     
    1/2 NPT Female
    0.5 to 55 11/16"±2%200 psi @ 70° F-10250EPM RubberAny AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom4165K1110000000
    1 to 105 11/16"±2%200 psi @ 70° F-10250EPM RubberAny AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom4165K121000000
     
    3/4 NPT Female
    1.5 to 155 11/16"±2%200 psi @ 70° F-10250EPM RubberAny AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom4165K131000000
     
    1 NPT Female
    2 to 205 11/16"±2%200 psi @ 70° F-10250EPM RubberAny AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom4165K141000000
    5 to 505 11/16"±2%200 psi @ 70° F-10250EPM RubberAny AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom4165K151000000
     
    Brass/Steel Body with Brass/Steel Fittings
     
    1 1/2 NPT Male
    15 to 15012"±2%200 psi @ 70° F-10250EPM RubberAny AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom4165K161000000
     
    2 NPT Male
    25 to 25012"±2%200 psi @ 70° F-10250EPM RubberAny AngleLeft to Right, Right to Left, Bottom to Top, Top to Bottom4165K171000000
     

    Flowmeter/Totalizers with Sanitary Quick-Clamp Fittings

    Image of Product. Shown with 90° Display
Adapter Kit. Front orientation. Contains Annotated. Flowmeters. Flowmeter/Totalizers with Sanitary Quick-Clamp Fittings.
    Image of Product. Front orientation. Flowmeters. Flowmeter/Totalizers with Sanitary Quick-Clamp Fittings.

    Shown with 90°

    Display Adapter Kit

    Image of Product. Front orientation. Flowmeter Displays. Flowmeter/Totalizers with Sanitary Quick-Clamp Fittings, Flowmeter/Totalizers, Digital Display.

    Replacement Displays

    Easy to remove for cleaning and maintenance, these flowmeter/totalizers connect to sanitary quick-clamp fittings (often called tri-clamp fittings) and measure the flow rate and volume of liquid passing through your system. You'll need a gasket and clamp to connect these to your line. They count how many times their turbine turns as liquid passes through to measure flow. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. You can reset the batch total, but you can't reset the cumulative total. Mount them directly inline with your piping system. They measure flow correctly no matter the mounting orientation.
    For use in hazardous locations, these flowmeter/totalizers are FM-approved. They’re also rated NEMA 4 to protect against weather and washdowns.
    These flowmeter/totalizers are calibrated with either water or solvent. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Calibration Certificate Traceable to NIST—Flowmeter/totalizers with a calibration certificate traceable to NIST include documentation that states that they’ve passed a test for accuracy.
    Flowmeter/Totalizers
    Replacement Displays
    Max. Volume
    Displayed
    Temp.,
    ° F
    Flowmeter/Totalizers
    Flowmeter/Totalizers with Calibration
    Certificate Traceable to NIST
    For Tube
    OD
    Connections
    Flow,
    gpm
    Flange
    OD
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Mounting
    Position
    Batteries
    Included
    Enclosure
    Rating
    Each
    Each
    Display
    Type
    Each
    Turbine Flow Measurement
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    3/4"Female1 to 100.984"5"±1.5%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140Any AngleYesIP65
    NEMA 4
    9011N110000000009011N21000000000Digital9011N4110000000
    1"Female2 to 201.984"5"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140Any AngleYesIP65
    NEMA 4
    9011N12000000009011N2200000000Digital9011N412000000
    1 1/2"Female5 to 501.984"5 1/2"±1%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140Any AngleYesIP65
    NEMA 4
    9011N13000000009011N2300000000Digital9011N413000000
    2"Female10 to 1002.515"6 1/2"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140Any AngleYesIP65
    NEMA 4
    9011N14000000009011N2400000000Digital9011N414000000
    2 1/2"Female20 to 2003.047"7"±0.75%999,999 Gallons999,999 Gallons1,500 psi @ 70° F14140Any AngleYesIP65
    NEMA 4
    9011N15000000009011N2500000000Digital9011N415000000
     
    Accessories for Flowmeters

    Totalizers for Drinking Water

    Image of Product. Front orientation. Exploded view. Contains Annotated. Flowmeters. Totalizers for Drinking Water, Brass Body, Female.

    Brass Body

    Female

    Image of Product. Front orientation. Exploded view. Contains Annotated. Flowmeters. Totalizers for Drinking Water, Brass Body, Male.

    Brass Body

    Male

    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Analog Display. Totalizers for Drinking Water, Brass Body.

    Brass Body

    Analog Display

    Meeting NSF/ANSI 61, these totalizers measure the cumulative amount of drinking water flowing through them. They use positive displacement, so they measure the flow by passing specific volumes of liquid through their chamber. Their total cannot be reset. Install them directly inline with your pipe system using the fittings on each end. They have a low-flow indicator to detect leaks in your system.
    These totalizers are calibrated with drinking water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from drinking water.
    Temp.,
    ° F
    Connections
    Flow, gpm
    Maximum Total Volume
    Displayed
    Inlet
    ID
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Display
    Type
    Features
    Each
    Brass Body with Bronze Fittings
    1/2 NPT Male0.5 to 2010,000,000 Gallons5/8"12 1/2"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator4041K210000000
    3/4 NPT Male0.5 to 2010,000,000 Gallons5/8"12 3/4"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator4041K22000000
    3/4 NPT Male0.75 to 3010,000,000 Gallons3/4"14 1/4"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator4041K61000000
    1 NPT Male0.75 to 3010,000,000 Gallons3/4"14 1/2"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator4041K62000000
    1 NPT Male1 to 5010,000,000 Gallons1"16 1/4"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator4041K23000000
    1 1/2 NPT Female2 to 100100,000,000 Gallons1 1/2"12 5/8"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator4041K2500000000
    2 NPT Female2.5 to 160100,000,000 Gallons2"15 1/4"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator4041K2600000000
     

    Totalizers

    Image of Product. Front orientation. Exploded view. Contains Annotated. Flowmeters. Totalizers, Nylon Body with 304 Stainless Steel/Nylon Fittings.
    Image of Product. Front orientation. Exploded view. Contains Annotated. Flowmeters. Totalizers, 304 Stainless Steel Body with 304 Stainless Steel Fittings.
    Image of Specification. Top orientation. Contains Border. Analog Display. Totalizers.

    Nylon Body with 304 Stainless

    Steel/Nylon Fittings

    304 Stainless Steel Body with 304 Stainless

    Steel Fittings

    Analog Display

    Measure the total amount of liquid flowing through these totalizers. They total the volume by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. Their total cannot be reset.
    These totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Totalizers
    Replacement
    Couplings
    Temp.,
    ° F
    Connections
    Flow, gpm
    Maximum Total Volume
    Displayed
    Inlet
    ID
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Display
    Type
    Each
    Pair
    Nylon Body with 304 Stainless Steel/Nylon Fittings
    1/2 NPT Male0.25 to 139,999,999 Gallons5/8"10"±1.5%100 psi @ 70° F35120Buna-N
    HorizontalAnalog4119K4100000004119K77000000
    3/4 NPT Male0.25 to 229,999,999 Gallons5/8"11 1/2"±1.5%100 psi @ 70° F35120Buna-N
    HorizontalAnalog4119K420000004119K7900000
    1 NPT Male0.75 to 509,999,999 Gallons3/4"10 3/4"±1.5%100 psi @ 70° F35120Buna-N
    HorizontalAnalog4119K43000000———0
    1 1/2 NPT Male2 to 1009,999,999 Gallons1 1/2"9 5/8"±1.5%100 psi @ 70° F35120Buna-N
    HorizontalAnalog4119K616000000———0
     
    304 Stainless Steel Body with 304 Stainless Steel Fittings
    1/2 NPT Male0.25 to 209,999,999 Gallons5/8"7 1/2"±1.5%150 psi @ 70° F35120Buna-N
    HorizontalAnalog4119K611000000———0
    3/4 NPT Male0.5 to 309,999,999 Gallons3/4"7 1/2"±1.5%150 psi @ 70° F35120Buna-N
    HorizontalAnalog4119K612000000———0
    1 NPT Male0.75 to 509,999,999 Gallons1"10 1/4"±1.5%150 psi @ 70° F35120Buna-N
    HorizontalAnalog4119K613000000———0
    1 1/2 NPT Male2 to 1009,999,999 Gallons1 1/2"11 7/8"±1.5%150 psi @ 70° F35120Buna-N
    HorizontalAnalog4119K614000000———0
    2 NPT Male2 to 1609,999,999 Gallons2"11 7/8"±1.5%150 psi @ 70° F35120Buna-N
    HorizontalAnalog4119K615000000———0
     
    Switches

    Flowmeters for High-Purity Liquids

    Image of Product. Front orientation. Flowmeters. Flowmeters for High-Purity Liquids.
    To avoid metal contaminating liquids, such as deionized water, these flowmeters are made entirely of plastic and rubber. As your liquid flows through, it pushes an indicator up the scale, showing you the flow rate. Mount these flowmeters vertically inline with your pipe system, so liquid flows up from the bottom. They have union fittings, making it easy to position the scale so it’s visible. The fittings are PVC, so they work with a wide range of chemicals.
    These flowmeters are calibrated using water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Temp.,
    ° F
    Flow, gpm
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Features
    Each
    Polysulfone Body with PVC Fittings
     
    1/2 NPT Female
    0.05 to 0.510"±6%150 psi @ 70° F33130Fluoroelastomer
    VerticalUnion Fittings9747K690000000
    0.1 to 110"±6%150 psi @ 70° F33130Fluoroelastomer
    VerticalUnion Fittings9747K72000000
     
    3/4 NPT Female
    0.2 to 2.410"±6%150 psi @ 70° F33130Fluoroelastomer
    VerticalUnion Fittings9747K73000000
    0.5 to 510"±6%150 psi @ 70° F33130Fluoroelastomer
    VerticalUnion Fittings9747K74000000
     
    1 NPT Female
    0.76 to 7.611 3/4"±6%150 psi @ 70° F33130Fluoroelastomer
    VerticalUnion Fittings9747K75000000
    1 to 1011 3/4"±6%150 psi @ 70° F33130Fluoroelastomer
    VerticalUnion Fittings9747K76000000
    1.5 to 1511 3/4"±6%150 psi @ 70° F33130Fluoroelastomer
    VerticalUnion Fittings9747K77000000
    2 to 2011 3/4"±6%150 psi @ 70° F33130Fluoroelastomer
    VerticalUnion Fittings9747K78000000
     

    Socket-Connect Flowmeter/Totalizers

    Image of ProductInUse. Shown with 90° Display
Adapter Kit. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers.

    Shown with 90°

    Display Adapter Kit

    Image of Product. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers.
    Image of Product. Front orientation. Flowmeter Displays. Socket-Connect Flowmeter/Totalizers, Flowmeter/Totalizers, Digital Display.

    Replacement Displays

    The unthreaded ends of these flowmeter/totalizers install into a PVC piping system, so you can measure the flow rate and volume of liquid passing through your system. Bond the joint together with PVC cement and primer. You can reset the batch total, but you can't reset the cumulative total. They measure flow correctly no matter the mounting orientation.
    These flowmeter/totalizers are calibrated with water.
    Turbine Flow Measurement—Turbine flowmeter/totalizers measure flow by counting how many times their turbine turns as liquid passes through. To avoid clogging the turbine and other damage, use them only with clean, low-viscosity liquids. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Ultrasonic Flow Measurement—Ultrasonic flowmeter/totalizers measure flow with ultrasonic waves, so they don’t have internal moving parts that can break or get stuck.
    Flowmeter/Totalizers
    Replacement Displays
    Flowmeter/Totalizers
    Max. Volume
    Displayed
    Temp., ° F
    Connections
    Flow, gpm
    Pipe
    Schedule
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Min.
    Max.
    Each
    Display
    Type
    Each
    Turbine Flow Measurement
     
    PVC Body with PVC Fittings and 316 Stainless Steel Seal
    1/2 Male1 to 1080
    4 5/16"±3%999,999 Gallons999,999 Gallons225 psi @ 70° FAny AngleYes331405020T7110000000Digital4352K5130000000
    3/4 Male2 to 2080
    4 7/16"±3%999,999 Gallons999,999 Gallons225 psi @ 70° FAny AngleYes331405020T721000000Digital4352K523000000
    1 Male5 to 5080
    4 1/2"±3%999,999 Gallons999,999 Gallons225 psi @ 70° FAny AngleYes331405020T731000000Digital4352K533000000
    1 1/2 Male10 to 10080
    5 3/8"±3%999,999 Gallons999,999 Gallons225 psi @ 70° FAny AngleYes331405020T741000000Digital4352K543000000
    2 Male20 to 20080
    5 1/2"±3%999,999 Gallons999,999 Gallons225 psi @ 70° FAny AngleYes331405020T751000000Digital4352K553000000
     
    Ultrasonic Flow Measurement
     
    PVC Body with PVC Fittings and EPDM Seal
    3 Male2.06 to 30980
    6 5/8"±2%999,999 Gallons999,999 Gallons200 psi @ 70° FAny AngleYes321403777K5100000000Digital3777K615000000
    4 Male3.58 to 53780
    7 3/8"±2%999,999 Gallons999,999 Gallons200 psi @ 70° FAny AngleYes321403777K5200000000Digital3777K625000000
     
    Accessories for Flowmeters

    Impact-Resistant Flowmeters

    Image of Product. Front orientation. Flowmeters. Impact-Resistant Flowmeters.
    A 304 stainless steel case protects these flowmeters from blows that could shatter the glass body. As liquid flows through the meter it pushes an indicator up the scale, showing you the flow rate. Mount these flowmeters vertically inline with your pipe system, so liquid flows up from the bottom.
    These flowmeters are calibrated using water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    They include a separate scale that you can swap in to use them with air.
    Temp.,
    ° F
    Flow, gpm
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Case Material
    Window
    Material
    Mounting
    Position
    Features
    Each
    Glass Body with 316 Stainless Steel Fittings
     
    1/2 NPT Female
    0.05 to 0.57 3/4"±5%200 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Polycarbonate
    VerticalAir Flow Scale (0.2-2 scfm)5083K380000000
    0.1 to 17 3/4"±5%200 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Polycarbonate
    VerticalAir Flow Scale (0.4-4 scfm)5083K12000000
    0.2 to 27 3/4"±5%200 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Polycarbonate
    VerticalAir Flow Scale (0.82-8.2 scfm)5083K39000000
     
    3/4 NPT Female
    0.06 to 0.6419 11/16"±2%200 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Polycarbonate
    VerticalAir Flow Scale (0.3-2.7 scfm)5083K3100000000
    0.14 to 1.4419 11/16"±2%200 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Polycarbonate
    VerticalAir Flow Scale (0.61-6.1 scfm)5083K3200000000
    0.3 to 319 11/16"±2%200 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Polycarbonate
    VerticalAir Flow Scale (1.2-12 scfm)5083K3300000000
    0.52 to 5.219 11/16"±2%200 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Polycarbonate
    VerticalAir Flow Scale (2.2-22 scfm)5083K3400000000
    1.2 to 1219 11/16"±2%200 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Polycarbonate
    VerticalAir Flow Scale (5-50 scfm)5083K3600000000
    2 to 21.619 11/16"±2%200 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Polycarbonate
    VerticalAir Flow Scale (10-100 scfm)5083K3700000000
     

    TIG Torch Gas Flowmeters

    Image of ProductInUse. Front orientation. Flowmeters. TIG Torch Gas Flowmeters.
    Image of Product. Front orientation. Flowmeters. TIG Torch Gas Flowmeters.
    Measure the flow of shielding gas at your TIG nozzle by attaching these gas flow testers. These flowmeters help maintain consistent flow rates across welding jobs and track failures in your TIG torch setup.
    Temp.
    Flow,
    ft³/hr
    Graduations,
    ft³/hr
    Accuracy
    Overall
    Ht.
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Display
    Type
    Each
    Acrylic Plastic Body
    5 to 502±5%5 3/8"50 psi @ 72° FNot RatedNot RatedRubber
    Scale7658N1000000
     

    Socket-Connect Flowmeter/Totalizers with Remote Display

    Often used in hard-to-access areas, these flowmeter/totalizers have a display that can be placed up to 25 feet from the sensor. Use them to measure the rate and volume of liquid flowing through your system. They measure flow by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. Batch totals are resettable but can be protected with a security code to prevent tampering. The reset function can also be disabled so that they operate as a cumulative totalizer. Cumulative totals cannot be reset. No matter the mounting orientation, they’ll measure flow correctly.
    These flowmeter/totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    For a complete unit, you’ll need a display, a sensor, and a tee fitting.
    Displays
    Image of Product. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers with Remote Display, Displays.
    Displays are rated NEMA 4X and IP65 for protection against dust, weather, washdowns, and corrosion.
    Displays
    Brackets
    Temp.,
    ° F
    For Panel
    Cutout, mm
    Mounting Slot
    Maximum Total
    Volume Displayed
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    For DIN Panel
    Cutout Size
    Ht.
    Wd.
    Dp.
    Batteries
    Included
    Enclosure
    Rating
    Each
    Lg.
    Wd.
    No.
    of
    Each
    9,999 Gallons
    9,999 Liters
    ±0.5%180 psi @ 70° F331491/4969641YesIP65
    NEMA 4X
    4114K33500000003/16"3/4"44114K94000000
     
    Sensors
    Image of Product. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers with Remote Display, Sensors.
    Sensors thread onto the tee fitting.
    Sensors
    Replacement
    Flowmeter Rotors
    Replacement
    Flowmeter Rotor Pins
    Temp.,
    ° F
    Connections
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Mounting
    Position
    Each
    Each
    Each
    Polypropylene Body
    1 1/4 NPSM4.1"±1%180 psi @ 70° F33149Any Angle4114K22200000004114K980000004114K99000000
     
    Tee Fittings
    Image of Product. Front orientation. Flowmeters. Socket-Connect Flowmeter/Totalizers with Remote Display, Tee Fittings.
    Tee fittings mount inline with your pipe. They have two unthreaded socket ends that bond to unthreaded PVC pipe with PVC cement and primer.
    Temp.,
    ° F
    Inlet/Outlet Connection
    Sensor Connection
    Pipe
    Schedule
    Flow, gpm
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Mounting
    Position
    Each
    PVC Body
    1/2 Socket Connect Female Inlet Pipe × 1/2 Socket Connect Female Outlet Pipe1 1/4 NPSM Threaded Male Pipe80
    1 to 18.9180 psi @ 70° F33149Any Angle4114K2310000000
    3/4 Socket Connect Female Inlet Pipe × 3/4 Socket Connect Female Outlet Pipe1 1/4 NPSM Threaded Male Pipe80
    1.7 to 33.2180 psi @ 70° F33149Any Angle4114K232000000
    1 Socket Connect Female Inlet Pipe × 1 Socket Connect Female Outlet Pipe1 1/4 NPSM Threaded Male Pipe80
    2.7 to 53.9180 psi @ 70° F33149Any Angle4114K233000000
    1 1/2 Socket Connect Female Inlet Pipe × 1 1/2 Socket Connect Female Outlet Pipe1 1/4 NPSM Threaded Male Pipe80
    6.4 to 126.9180 psi @ 70° F33149Any Angle4114K235000000
    2 Socket Connect Female Inlet Pipe × 2 Socket Connect Female Outlet Pipe1 1/4 NPSM Threaded Male Pipe80
    10.5 to 209.2180 psi @ 70° F33149Any Angle4114K236000000
    3 Socket Connect Female Inlet Pipe × 3 Socket Connect Female Outlet Pipe1 1/4 NPSM Threaded Male Pipe80
    23 to 460.8180 psi @ 70° F33149Any Angle4114K238000000
     

    Flanged Flowmeter/Totalizers

    Image of Product. Front orientation. Flowmeters. Flanged Flowmeter/Totalizers.
    Image of Specification. Replacement Displays. Front orientation. Digital Display. Flanged Flowmeter/Totalizers.

    Replacement Displays

    Using the flanged ends, securely install these flowmeter/totalizers in large, high-flow pipelines to measure the flow rate and total volume of liquid flowing through. They use ultrasonic waves to measure flow, so they don’t have any internal moving parts that can break or get stuck. You can reset the batch total, but you can't reset the cumulative total. They measure accurately in any mounting orientation.
    These flowmeter/totalizers are calibrated with water.
    Flowmeter/Totalizers
    Replacement Displays
    Flowmeter/Totalizers
    Max. Volume
    Displayed
    Temp., ° F
    Connections
    Flow, gpm
    Flange
    OD
    For Flange
    ANSI Class
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Min.
    Max.
    Each
    Display
    Type
    Each
    Ultrasonic Flow Measurement
     
    PVC Body with PVC Fittings and EPDM Seal
    3 Pipe Size
    2.06 to 3097 1/2"150
    13 1/4"±2%999,999 Gallons999,999 Gallons200 psi @ 70° FAny AngleYes321403777K61000000000Digital3777K6150000000
    4 Pipe Size
    3.58 to 5379"150
    13 3/16"±2%999,999 Gallons999,999 Gallons200 psi @ 70° FAny AngleYes321403777K6200000000Digital3777K625000000
     

    High-Temperature Totalizers

    Image of Product. Front orientation. Exploded view. Contains Annotated. Flowmeters. High-Temperature Totalizers, Bronze Body.
    Image of Product. Front orientation. Exploded view. Contains Annotated. Flowmeters. High-Temperature Totalizers, Brass Body.

    Bronze Body

    Brass Body

    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Analog Display. High-Temperature Totalizers, Bronze Body.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Analog Display. High-Temperature Totalizers, Brass Body.

    Bronze Body

    Analog Display

    Brass Body

    Analog Display

    Use these totalizers to measure the total amount of high-temperature liquid flowing through your pipe system. They total the volume by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to these totalizers, use them only with clean, low-viscosity liquids. Their total cannot be reset. They measure correctly no matter the mounting orientation.
    These totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Temp.,
    ° F
    Connections
    Flow, gpm
    Maximum Total Volume
    Displayed
    Inlet
    ID
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Display
    Type
    Each
    Brass Body with Brass Fittings
    3/4 NPT Male0.2 to 209,999,999.9 Gallons3/4"10 1/8"±1.5%150 psi @ 200° F32200Fluoroelastomer
    Any AngleAnalog4115K420000000
     
    Bronze Body with Bronze Fittings
    3/4 NPT Male0.22 to 2299,999,900 Gallons1"7 1/2"±1.5%150 psi @ 70° F33194PlasticAny AngleAnalog9817K13000000
    1 NPT Male0.44 to 5299,999,900 Gallons1 1/4"10 1/4"±1.5%150 psi @ 70° F33194PlasticAny AngleAnalog9817K14000000
    1 1/2 NPT Male0.88 to 8899,999,900 Gallons2"11 3/4"±1.5%150 psi @ 70° F33194PlasticAny AngleAnalog9817K1500000000
    2 NPT Male1.98 to 13299,999,900 Gallons2 1/2"11 3/4"±1.5%150 psi @ 70° F33194PlasticAny AngleAnalog9817K2100000000
     

    Any-Orientation Flowmeters for Oil

    Image of Product. Front orientation. Flowmeters. Any-Orientation Flowmeters for Oil.
    With a spring piston instead of a float, these flowmeters measure the flow rate of oil in any mounting orientation. As oil flows through, it pushes an indicator up the scale, showing you the flow rate. Install them inline with your piping system with the fittings on both ends. They’re union fittings, making it easy to position the scale so it’s visible.
    These flowmeters are calibrated with oil but can be used with other liquids. If you’re using these with a liquid other than oil, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Choose a fitting material that is compatible with the liquid you intend to run through your line.
    Polysulfone Fitting—Polysulfone fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
    Brass Fitting—Brass fittings resist impact better than polysulfone fittings.
    Temp.,
    ° F
    Flow,
    gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Features
    Each
    Polysulfone Body with Polysulfone Fittings
     
    1/2 NPTF Female
    0.5 to 57 3/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A710000000
    1 to 107 3/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A72000000
     
    3/4 NPTF Female
    1 to 107 9/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A73000000
    1 to 157 9/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A74000000
     
    1 NPTF Female
    1 to 157 9/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A75000000
    3 to 307 9/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A76000000
     
    Polysulfone Body with Brass Fittings
     
    1/2 NPTF Female
    0.5 to 57 3/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A51000000
    1 to 107 3/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A52000000
     
    3/4 NPTF Female
    1 to 107 9/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A53000000
    1 to 157 9/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A54000000
     
    1 NPTF Female
    1 to 157 9/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A55000000
    3 to 307 9/16"±5%325 psi @ 70° F33200Fluoroelastomer
    Any AngleUnion Fittings4161A56000000
     

    Flowmeters with Flow Switch

    Image of Product. Front orientation. Flowmeters. Flowmeters with Flow Switch.
    Monitor the flow rate of liquids and use the integrated switch to turn equipment on and off, or activate an alarm when liquid reaches a set flow rate. The switch is single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or on to off (normally closed). As liquid flows through these flowmeters it pushes an indicator up the scale, showing you the flow rate. Mount them inline with your pipe system. They will measure flow correctly no matter which orientation you mount them in. Rated NEMA 13, they protect against dust, spraying oil, and wet environments.
    These flowmeters are calibrated using water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Temp.,
    ° F
    Wire
    Leads
    Flow,
    gpm
    Switch Set
    Point, gpm
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Max. Switching Current @ Voltage
    No.
    of
    Lg.
    Seal Material
    Mounting
    Position
    Enclosure
    Rating
    Each
    Brass Body with Brass Fittings
     
    1/4 NPT Female
    0.1 to 10.1 to 16 5/8"±2%3,500 psi @ 240° F-2024010 amp @ 250V AC, 0.5 amp @ 125V DC434"Viton® Fluoroelastomer
    VerticalNEMA 13
    4392N101000000000
    0.2 to 20.2 to 26 5/8"±2%3,500 psi @ 240° F-2024010 amp @ 250V AC, 0.5 amp @ 125V DC434"Viton® Fluoroelastomer
    VerticalNEMA 13
    4392N10200000000
     
    1/2 NPT Female
    0.2 to 20.2 to 26 5/8"±2%3,500 psi @ 240° F-2024010 amp @ 250V AC, 0.5 amp @ 125V DC434"Viton® Fluoroelastomer
    VerticalNEMA 13
    4392N10300000000
    0.5 to 50.5 to 56 5/8"±2%3,500 psi @ 240° F-2024010 amp @ 250V AC, 0.5 amp @ 125V DC434"Viton® Fluoroelastomer
    VerticalNEMA 13
    4392N10400000000
    1 to 151 to 156 5/8"±2%3,500 psi @ 240° F-2024010 amp @ 250V AC, 0.5 amp @ 125V DC434"Viton® Fluoroelastomer
    VerticalNEMA 13
    4392N10500000000
     
    3/4 NPT Female
    0.5 to 50.5 to 57 3/16"±2%3,500 psi @ 240° F-2024010 amp @ 250V AC, 0.5 amp @ 125V DC434"Viton® Fluoroelastomer
    VerticalNEMA 13
    4392N10600000000
    1 to 101 to 107 3/16"±2%3,500 psi @ 240° F-2024010 amp @ 250V AC, 0.5 amp @ 125V DC434"Viton® Fluoroelastomer
    VerticalNEMA 13
    4392N10700000000
    3 to 303 to 307 3/16"±2%3,500 psi @ 240° F-2024010 amp @ 250V AC, 0.5 amp @ 125V DC434"Viton® Fluoroelastomer
    VerticalNEMA 13
    4392N10800000000
     
    1 NPT Female
    0.5 to 50.5 to 57 3/16"±2%3,500 psi @ 240° F-2024010 amp @ 250V AC, 0.5 amp @ 125V DC434"Viton® Fluoroelastomer
    VerticalNEMA 13
    4392N10900000000
    1 to 101 to 107 3/16"±2%3,500 psi @ 240° F-2024010 amp @ 250V AC, 0.5 amp @ 125V DC434"Viton® Fluoroelastomer
    VerticalNEMA 13
    4392N11100000000
    3 to 303 to 307 3/16"±2%3,500 psi @ 240° F-2024010 amp @ 250V AC, 0.5 amp @ 125V DC434"Viton® Fluoroelastomer
    VerticalNEMA 13
    4392N11200000000
    4 to 404 to 407 3/16"±2%3,500 psi @ 240° F-2024010 amp @ 250V AC, 0.5 amp @ 125V DC434"Viton® Fluoroelastomer
    VerticalNEMA 13
    4392N11300000000
     

    Totalizers with Digital Display

    Image of Product. Front orientation. Flowmeters. Totalizers with Digital Display.
    A digital display makes it easy to check both the total amount of liquid that’s flowed through and the batch total. These totalizers are useful in applications where water needs to be batched and dispensed. You can reset the batch total, but you can't reset the cumulative total. They measure flow volume by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to these totalizers, use them only with clean, low-viscosity liquids. They’re accurate in any mounting orientation. Mount them inline with your pipe system. Rated IP65, they seal out dust and can be lightly rinsed.
    These totalizers are calibrated with solvent. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from solvent.
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow
    Total
    Batch
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Display
    Type
    Batteries
    Included
    Enclosure
    Rating
    Each
    Nylon Body
     
    Gallons
    1 NPT Female3 gpm to 30 gpm9,999 Gallons9,999 Gallons4"±5%150 psi @ 70° F14130316 Stainless Steel
    Any AngleDigitalYesIP65
    9978K750000000
     
    Liters
    1 NPT Female10 L/min to 100 L/min9,999 Liters9,999 Liters4"±5%150 psi @ 70° F14130316 Stainless Steel
    Any AngleDigitalYesIP65
    9978K76000000
     
    Gallons and Liters
    1 NPT Female0.3 gpm to 3 gpm999,999 Gallons
    999,999 Liters
    999,999 Gallons
    999,999 Liters
    4"±5%150 psi @ 70° F0130316 Stainless Steel
    Any AngleDigitalYesIP65
    9978K81000000
     

    Socket-Connect Flowmeters

    Image of Product. Front orientation. Flowmeters. Socket-Connect Flowmeters.
    Easily install the unthreaded ends of these flowmeters into a PVC piping system. Bond the ends to PVC pipe with PVC cement and primer. They measure flow correctly no matter the mounting orientation. As liquid flows through the meter, it pushes an indicator up the scale, showing you the flow rate. They work with a wide range of chemicals since the fittings are made from PVC.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Temp.,
    ° F
    Flow,
    gpm
    Overall
    Ht.
    Accuracy
    For Pipe
    Schedule
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Each
    Polysulfone Body with PVC Fittings
     
    1 Male
    0.5 to 48 1/2"±5%40, 80
    Not Rated32140Buna-N
    Any Angle4197K410000000
    1 to 108 1/2"±5%40, 80
    Not Rated32140Buna-N
    Any Angle4197K43000000
    3 to 188 1/2"±5%40, 80
    Not Rated32140Buna-N
    Any Angle4197K45000000
    4 to 288 1/2"±5%40, 80
    Not Rated32140Buna-N
    Any Angle4197K46000000
     

    High-Temperature Panel-Mount Flowmeters

    Image of Product. Front orientation. Contains Annotated. Flowmeters. High-Temperature Panel-Mount Flowmeters, Male, Flowmeters.
    Image of Product. Front orientation. Contains Annotated. Flowmeters. High-Temperature Panel-Mount Flowmeters, Male, Flowmeters with Flow-Control Knob.

    Male

    Flowmeters

    Male, Flowmeters

    with Flow-Control

    Knob

    Install these flowmeters in an instrument panel to measure the flow rate of hot water and other liquids reaching up to 212° F. They should be mounted vertically, so liquid flows up from the bottom. As liquid flows through, it pushes an indicator up the scale, showing you the flow rate.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Flow-Control Knob—Flowmeters with a flow-control knob let you open and close the inlet valve to adjust the flow rate within the range.
    Flow
    Temp.,
    ° F
    Flowmeters
    Flowmeters with
    Flow-Control Knob
    US Customary,
    gpm
    Metric,
    L/min
    Overall
    Ht.
    Ctr.-to-Ctr.
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Each
    Each
    Polysulfone Body with Polysulfone Fittings
     
    3/8 NPT Male
    0.025 to 0.250.1 to 17"6"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K6600000004215K760000000
    0.1 to 10.4 to 47"6"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K670000004215K77000000
    0.2 to 20.75 to 7.57"6"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K680000004215K78000000
    0.5 to 51.8 to 187"6"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K690000004215K79000000
     
    1/2 NPT Male
    0.025 to 0.250.1 to 17"6"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K610000004215K71000000
    0.1 to 10.4 to 47"6"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K620000004215K72000000
    0.2 to 20.75 to 7.57"6"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K630000004215K73000000
    0.5 to 51.8 to 187"6"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K640000004215K74000000
     
    3/4 NPT Male
    1 to 105 to 37.58"6 13/16"±4%175 psi @ 70° F33212Fluoroelastomer
    Vertical4215K650000004215K75000000
     

    Flanged Flowmeters

    Image of Product. Front orientation. Flowmeters. Flanged Flowmeters.
    Install these flowmeters securely into large pipelines with the flanged ends. They have a case that protects them from blows that could crack or shatter the body. Mount them vertically inline with your pipe system, so liquid flows up from the bottom. As liquid flows through the meter, it pushes an indicator up the scale, showing you the flow rate.
    These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Temp.,
    ° F
    Flow, gpm
    Flange
    OD
    For Flange
    ANSI Class
    Overall
    Ht.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Case Material
    Window
    Material
    Mounting
    Position
    Each
    Glass Body with 316 Stainless Steel Fittings
     
    1/2 Pipe Size
    0.25 to 13 1/2"150
    14 3/4"±3%250 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Polycarbonate
    Vertical4389N102000000000
    0.25 to 23 1/2"150
    14 3/4"±3%250 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Polycarbonate
    Vertical4389N10300000000
     
    1 Pipe Size
    0.25 to 54 1/4"150
    14 3/4"±3%200 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Polycarbonate
    Vertical4389N10400000000
    0.25 to 114 1/4"150
    14 3/4"±3%200 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Polycarbonate
    Vertical4389N10500000000
    0.25 to 204 1/4"150
    14 3/4"±3%200 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Polycarbonate
    Vertical4389N10600000000
     
    1 1/2 Pipe Size
    0.25 to 225"150
    13 13/16"±3%150 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Polycarbonate
    Vertical4389N10700000000
    0.25 to 305"150
    13 13/16"±3%150 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Polycarbonate
    Vertical4389N10800000000
    0.25 to 505"150
    13 13/16"±3%150 psi @ 70° F33200Fluoroelastomer
    304 Stainless Steel
    Polycarbonate
    Vertical4389N10900000000
     

    Totalizers for Grease

    Image of Product. Front orientation. Flowmeters. Totalizers for Grease.
    Install this totalizer on your grease gun or valve to measure grease dispensing and reduce waste. They use positive displacement, so they measure the flow by passing specific volumes of liquid through a pair of oval gears. Their total can be reset. They measure flow accurately no matter the mounting orientation.
    These totalizers are calibrated with oil. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Total
    Batch
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Ht.
    Wd.
    Dp.
    Display
    Type
    Batteries
    Included
    Each
    Aluminum Body with Aluminum Fittings
    1/8 NPT Female9,999 Cubic Centimeters
    9,999 Ounces
    999 Cubic Centimeters
    99 Ounces
    ±3%10,000 psi @ 70° F-4130Neoprene
    Any Angle2 1/2"3"2 1/2"DigitalYes6727T11000000000
     

    Flow- and Pressure-Testing Flowmeters for Oil

    Image of Product. Front orientation. Flowmeters. Flow- and Pressure-Testing Flowmeters for Oil.
    Often used to find worn components or leaks, these flowmeters have a valve, so you can test the flow of oil from pumps and other equipment at different pressures. Keep the valve fully open to measure the maximum flow rate at zero pressure. Pressure increases as you close the valve. As oil flows through, it pushes an indicator up the scale, showing you the flow rate. The scale rotates 360°, so you can check the flow rate from any angle. These flowmeters are accurate in any mounting orientation. Mount them inline with your pipe system.
    These flowmeters are calibrated with oil but can be used with other liquids. If you’re using these with a liquid other than oil, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
    Temp.,
    ° F
    Pressure
    Gauge
    Flow,
    gpm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Measurement,
    psi
    Dial
    Size
    Body
    Material
    Seal Material
    Mounting
    Position
    Features
    Each
    Aluminum Fitting with Aluminum Valve
     
    1/2 NPTF Female
    1 to 1510 5/16"±2%3,500 psi @ 70° F-202400 to 3,5002 1/2"Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K540000000
     
    3/4 NPTF Female
    2 to 2011 5/16"±2%3,500 psi @ 70° F-202400 to 3,5002 1/2"Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K5700000000
    3 to 3011 5/16"±2%3,500 psi @ 70° F-202400 to 3,5002 1/2"Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K5800000000
     
    1 1/4 NPTF Threaded Male Pipe Inlet × 1 1/4 NPTF Threaded Female Pipe Outlet
    10 to 10022"±2%3,500 psi @ 70° F-202400 to 3,5002 1/2"Aluminum
    Fluoroelastomer
    Any AngleRotating Scale4263K6200000000
     

    Totalizers for Natural, Propane, and Butane Gas

    Image of Product. Front orientation. Flowmeters. Totalizers for Natural, Propane, and Butane Gas.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Analog Display. Totalizers for Natural, Propane, and Butane Gas, Aluminum Body.

    Analog Display

    Often used in heating, cooking, and power-generating systems, these totalizers measure the total amount of natural gas, propane, and butane that flow through them. They use positive displacement, so they measure the flow by passing specific volumes of gas through their diaphragm. Their total cannot be reset. Mount them inline with your pipe system.
    Temp.,
    ° F
    Connections
    Flow,
    ft³/hr
    Maximum Total Volume
    Displayed
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Ht.
    Wd.
    Dp.
    Display
    Type
    Each
    Aluminum Body with Iron Fittings
    3/4 NPT Female0 to 250999,900 Cubic Feet±1%5 psi @ 70° F-30140Buna-N
    Horizontal13"9"9"Analog4360K210000000
    1 1/4 NPT Male0 to 425999,900 Cubic Feet±1%10 psi @ 70° F-30140Buna-N
    Horizontal15"11"10"Analog4360K22000000
     

    High-Temperature Flowmeter/Totalizers

    Image of Product. Front orientation. Flowmeters. High-Temperature Flowmeter/Totalizers.
    With one meter, these flowmeter/totalizers measure the flow rate and total flow volume of high-temperature liquid up to 200° F. They count how many times their turbine turns as liquid passes through to measure flow. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. The batch total can be reset after each metering application. They come set for batch totalization, but you can disable the reset function to operate as a cumulative totalizer. They measure flow correctly no matter the mounting orientation.
    These flowmeter/totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Flowmeter/Totalizers
    Max. Volume
    Displayed
    Temp., ° F
    Connections
    Flow,
    gpm
    End-to-End
    Lg.
    Accuracy
    Total
    Batch
    Max. Pressure
    @ Temp.
    Mounting
    Position
    Batteries
    Included
    Enclosure
    Rating
    Min.
    Max.
    Each
    Turbine Flow Measurement
     
    Polypropylene Body with Polypropylene Fitting and Fluoroelastomer Seal
    3/8 NPT Male0.8 to 84 3/4"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K310000000
    1/2 NPT Male2 to 205 1/8"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K32000000
    3/4 NPT Male3 to 305 1/4"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K33000000
    1 NPT Male5 to 505 5/8"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K34000000
    1 1/2 NPT Male6 to 606 1/2"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K35000000
    2 NPT Male10 to 1006 3/4"±2%99,999.9 Gallons999,999 Gallons300 psi @ 70° FAny AngleYesIP56
    NEMA 4X
    332003562K36000000
     
    Replacements for Flowmeters

    Totalizers with Digital Display for Fuel

    Image of Product. Front orientation. Flowmeters. Totalizers with Digital Display for Fuel.
    Track batches and the total amount of gasoline, diesel fuel, and kerosene passing through your system. The batch total is resettable, but you can't reset the cumulative total. They automatically reset the batch to zero when they reach the maximum. They measure flow volume by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to these totalizers, use them only with clean, low-viscosity liquids. They’re accurate in any mounting orientation. Mount them inline with your pipe system.
    These totalizers are calibrated with diesel fuel. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from diesel fuel.
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow
    Total
    Batch
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Display
    Type
    Batteries
    Included
    Each
    Aluminum Body with Steel Fittings
    1 NPT Female3 gpm to 30 gpm9,999 Gallons9,999 Gallons4"±5%300 psi @ 70° F14130316 Stainless Steel
    Any AngleDigitalYes9978K770000000
    1 NPT Female10 L/min to 100 L/min9,999 Liters9,999 Liters4"±5%300 psi @ 70° F14130316 Stainless Steel
    Any AngleDigitalYes9978K78000000
     

    Totalizers for Fuel

    Image of Product. Front orientation. Flowmeters. Totalizers for Fuel.
    Determine the amount of gasoline, diesel fuel, and kerosene that flows through these totalizers. They measure the total amount of flow and can be set to measure in batches, which means they measure up to a certain volume. The total cannot be reset, but the batch measurement can. They use positive displacement, so they measure flow by passing specific volumes of liquid through their chamber. They’re accurate in any mounting orientation. Mount them inline with your pipe system. Their mesh strainer traps debris to help prevent clogging.
    These totalizers are calibrated with diesel fuel. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow
    Total
    Batch
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Ht.
    Wd.
    Dp.
    Display
    Type
    Features
    Each
    Aluminum Body
    1 NPT Female5 gpm to 30 gpm999,999.9 Gallons999.9 Gallons±2%50 psi @ 70° F-20125Buna-N
    Any Angle8"6"5 1/4"AnalogMesh Strainer9854K110000000
    1 NPT Female19 L/min to 114 L/min999,999.9 Liters999.9 Liters±2%50 psi @ 70° F-20125Buna-N
    Any Angle8"6"5 1/4"AnalogMesh Strainer9854K12000000
     

    Totalizers for Oil

    Image of Product. Front orientation. Flowmeters. Totalizers for Oil.
    Measure the amount of light oil that flows through these totalizers. They use positive displacement, so they measure flow by passing specific volumes of liquid through a chamber. Their total can be reset. Manually or automatically turn them on, and they automatically shut down 40 seconds after flow stops. Their mounting orientation won’t affect their ability to measure flow correctly. Install these totalizers directly inline with your pipe system using the fittings on each end. The fittings are 316 stainless steel, so they resist impact better than plastic fittings.
    These totalizers are calibrated with water. You can recalibrate them in the field to other liquids, pipe, and operating conditions.
    Cannot Be Sold Outside North America—Products cannot be sold outside North America due to restrictions.
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Maximum Total Volume
    Displayed
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Ht.
    Wd.
    Dp.
    Display
    Type
    Batteries
    Included
    Features
    Cannot Be Sold To
    Each
    Nylon Body with 316 Stainless Steel Fittings
    1 NPT Male2 to 30999,999.9 Gallons
    999,999.9 Liters
    999,999.9 Ounces
    ±0.5%60 psi @ 70° F33130Viton® Fluoroelastomer
    Any Angle5"6"4"DigitalYesAutomatic Start and StopOutside North America41935K480000000
     
    316 Stainless Steel Body with 316 Stainless Steel Fittings
    1 NPT Male2 to 30999,999.9 Gallons
    999,999.9 Liters
    999,999.9 Ounces
    ±0.5%100 psi @ 70° F33185Viton® Fluoroelastomer
    Any Angle5"5"4"DigitalYesAutomatic Start and StopOutside North America41935K97000000
     

    Remote-Reading Totalizers for Drinking Water

    Image of Product. Front orientation. Exploded view. Contains Annotated. Flowmeters. Remote-Reading Totalizers for Drinking Water, Brass Body, Female.
    Image of Product. Front orientation. Exploded view. Contains Annotated. Flowmeters. Remote-Reading Totalizers for Drinking Water, Brass Body, Male.

    Brass Body

    Female

    Brass Body

    Male

    Image of Specification. Top orientation. ZoomedIn view. Contains Border. Analog Display. Remote-Reading Totalizers for Drinking Water, Brass Body.
    Image of Product. Front orientation. ZoomedIn view. Flowmeter Displays. Remote-Reading Totalizers for Drinking Water.

    Analog Display

    Replacement Remote Displays

    Often used in hard-to-access areas, these totalizers let you monitor the total amount of drinking water flowing through them up to 250 feet away. They meet NSF/ANSI 61 for safe use with drinking water. They use positive displacement, so they measure flow by passing specific volumes of liquid through a chamber. Their total cannot be reset. Mount them inline with your pipe system. They have a low-flow indicator to detect leaks in your system.
    These totalizers are calibrated with drinking water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from drinking water.
    Totalizers
    Replacement
    Remote Displays
    Temp.,
    ° F
    Connections
    Flow, gpm
    Maximum Total Volume
    Displayed
    Inlet
    ID
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal
    Material
    Mounting
    Position
    Display
    Type
    Features
    Each
    Each
    Brass Body with Bronze Fittings
    1/2 NPT Male0.5 to 2099,999,999 Gallons5/8"12 1/2"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator, Remote Display (Battery Included)3786K9100000003786K110000000
    3/4 NPT Male0.5 to 2099,999,999 Gallons5/8"12 3/4"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator, Remote Display (Battery Included)3786K920000003786K11000000
    3/4 NPT Male0.75 to 3099,999,999 Gallons3/4"14 1/4"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator, Remote Display (Battery Included)3786K810000003786K11000000
    1 NPT Male0.75 to 3099,999,999 Gallons3/4"14 1/2"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator, Remote Display (Battery Included)3786K820000003786K11000000
    1 NPT Male1 to 5099,999,999 Gallons1"16 1/4"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator, Remote Display (Battery Included)3786K930000003786K11000000
    1 1/2 NPT Female2 to 10099,999,999 Gallons1 1/2"12 5/8"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator, Remote Display (Battery Included)3786K95000000003786K12000000
    2 NPT Female2.5 to 16099,999,999 Gallons2"15 1/4"±1.5%150 psi @ 70° F3380EPM RubberHorizontalAnalogLow-Flow Indicator, Remote Display (Battery Included)3786K96000000003786K12000000
     
    Thermostat Cable

    High-Temperature Totalizers with Digital Display

    Image of Product. Front orientation. Flowmeters. High-Temperature Totalizers with Digital Display.
    The digital display on these totalizers makes it easy to check the total amount of high-temperature liquid—up to 200° F—passing through your system. They measure flow volume by counting how many times their turbine turns as liquid passes through. To avoid clogging the turbine and other damage to these totalizers, use them only with clean, low-viscosity liquids. The batch total can be reset after each metering application. They come set for batch totalization, but you can disable the reset function to operate as a cumulative totalizer. They measure flow accurately no matter the mounting orientation. Rated NEMA 4X and IP65, they seal out dust and protect against washdowns and corrosion.
    These totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Max. Volume
    Displayed
    Temp.,
    ° F
    Connections
    Flow,
    gpm
    Total
    Batch
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Min.
    Max.
    Seal Material
    Mounting
    Position
    Display
    Type
    Batteries
    Included
    Enclosure
    Rating
    Each
    Polypropylene Body with Polypropylene Fittings
    3/8 NPT Male0.8 to 899,999.9 Gallons999,999 Gallons4 3/4"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K210000000
    1/2 NPT Male2 to 2099,999.9 Gallons999,999 Gallons5 1/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K22000000
    3/4 NPT Male3 to 3099,999.9 Gallons999,999 Gallons5 1/4"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K23000000
    1 NPT Male5 to 5099,999.9 Gallons999,999 Gallons5 5/8"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K24000000
    1 1/2 NPT Male6 to 6099,999.9 Gallons999,999 Gallons6 1/2"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K25000000
    2 NPT Male10 to 10099,999.9 Gallons999,999 Gallons6 3/4"±2%300 psi @ 70° F33200Fluoroelastomer
    Any AngleDigitalYesIP56
    NEMA 4X
    3562K26000000
     
    Replacements for Flowmeters