McMaster-Carr logo
    Filter by
    Discharge Pipe Size
    Industrial Info Compare
    Electrical Phase
    Frequency
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Discharge Connection Port
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    324 Products

    High-Head High-Efficiency Circulation Pumps for Water, Coolants, and Oil

    Image of Product. Front orientation. Centrifugal Pumps. High-Head High-Efficiency Circulation Pumps for Water, Coolants, and Oil.
    Propel liquid higher and farther than standard high-efficiency circulation pumps. These pumps use less electricity to achieve the same flow rates as other circulation pumps. They have a totally enclosed fan cooled (TEFC) motor for use in dusty, dirty, and damp environments. Adjust the housing studs to make the discharge direction more vertical or horizontal. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids. They cannot be sold to the regions listed due to local energy efficiency requirements.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 60 ft.
    of Head
    @ 70 ft.
    of Head
    @ 80 ft.
    of Head
    @ 90 ft.
    of Head
    @ 100 ft.
    of Head
    @ 110 ft.
    of Head
    @ 120 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Cannot Be Sold To
    Each
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—17 cP Maximum Viscosity
    402975150025013 amp to 3.2 amp/1.5 amp1 1/4 Female NPT1 Female NPT16"7 7/8"9"California, Canada8256K41000000000
    50473930110150025026 amp/3 amp1 1/4 Female NPT1 Female NPT16"7 7/8"9"California, Canada8256K4300000000
    5037269215002501 1/24.6 amp to 4.9 amp/2.3 amp1 1/4 Female NPT1 Female NPT16"7 7/8"9"California, Canada8256K4200000000
    80705847137150025037.4 amp to 7.9 amp/3.7 amp1 1/2 Female NPT1 1/4 Female NPT18"10"9 7/8"Canada8256K4400000000
    200165145124971351500250511.6 amp to 12.6 amp/5.8 amp2 Female NPT1 1/2 Female NPT22"9 1/4"10"Canada8256K4500000000
     

    High-Efficiency Circulation Pumps for Water, Coolants, and Oil

    Use less electricity to achieve the same flow rates as other circulation pumps. These pumps have a totally enclosed motor for use in dusty, dirty, and damp environments. Adjust the housing studs to make the discharge direction more vertical or horizontal. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    120V AC/208V AC to 240V AC, Single Phase—Without Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. High-Efficiency Circulation Pumps for Water, Coolants, and Oil.
    Pumps
    Impellers
    Overall
    Max. Flow
    Rate, gpm
    Flow Rate @ 20 ft.
    of Head, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    Hardwire
    252426100171/36.2 amp/3.1 amp to 3.4 amp1 Female NPT3/4 Female NPT14"8 1/2"7"9923K410000000004320K260000000
    403734100171/27.4 amp/3.6 amp to 3.7 amp1 Female NPT3/4 Female NPT14"7 5/8"7 15/16"9923K420000004320K27000000
     
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. High-Efficiency Circulation Pumps for Water, Coolants, and Oil.
    Cannot Be Sold To—Pumps that cannot be sold to the listed regions do not meet energy efficiency requirements.
    Pumps
    Impellers
    Flow
    Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Cannot Be
    Sold To
    Each
    Each
    Hardwire
    3002101406210017511.8 amp/5.9 amp2 1/2 Female NPT2 Female NPT21 1/2"12"11"Canada9923K480000000004320K530000000
     
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. High-Efficiency Circulation Pumps for Water, Coolants, and Oil.
    Cannot Be Sold To—Pumps that cannot be sold to the listed regions do not meet energy efficiency requirements.
    Pumps
    Impellers
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 70 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Cannot Be Sold To
    Each
    Each
    Hardwire
    453440100173/43 amp to 3.3 amp/1.5 amp1 Female NPT3/4 Female NPT14"8 1/2"7"9923K4300000004320K280000000
    1307560531001713 amp to 3.2 amp/1.5 amp1 1/2 Female NPT1 1/4 Female NPT15"9"8"California, Canada9923K45000000004320K29000000
    15512585581001737.2 amp to 7.9 amp/3.6 amp2 Female NPT1 1/2 Female NPT17"10 1/2"8"Canada9923K47000000004320K49000000
    16012585561001725 amp to 5.3 amp/2.5 amp2 Female NPT1 1/2 Female NPT17"10 1/2"8"Canada9923K46000000004320K31000000
    26021076100177 1/216.8 amp to 18.5 amp/8.4 amp2 1/2 Female NPT2 Female NPT23"12"11"Canada9923K49000000004320K54000000
     

    Extended-Life Plastic Circulation Pumps for Chemicals

    Image of Product. Front orientation. Centrifugal Pumps. Extended-Life Plastic Circulation Pumps for Chemicals.
    These pumps have the best chemical resistance of all our circulation pumps. Instead of a shaft seal, they use magnets to turn the impeller, reducing wear and leakage. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Repair Kits
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Pipe Size
    (Gender)
    Discharge Pipe
    Size (Gender)
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    120V AC/240V AC, Single Phase—Without Thermal Overload Protection
     
    Hardwire
    232010351/42.07 amp/4.14 amp1 (Female)1 (Female)14 3/8"5 1/8"7 7/8"3068N110000000003068N11200000003068N111000000
    262612351/33.24 amp/6.84 amp1 (Female)1 (Female)16 5/16"6 1/8"8 3/16"3068N12000000003068N1220000003068N12100000
     
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    5757533025451/21.1 amp/2.2 amp1 1/2 (Female)1 1/2 (Female)18 3/8"8 7/8"11 5/16"3068N13000000003068N1320000003068N13100000
    9090847461497011.5 amp/3 amp1 1/2 (Female)1 1/2 (Female)18 7/8"6 5/16"10 1/8"3068N14000000003068N1420000003068N14100000
     
    120V AC/208V AC to 240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    38363227214951/27.5 amp/3.7 amp1 (Female)3/4 (Male)15 1/2"9"8 1/4"3068N19000000003068N2220000003068N2210000
    535346403323260519.2 amp/4.6 amp to 6.3 amp1 1/2 (Female)1 (Male)17 13/16"9 1/8"8 3/16"3068N18000000003068N2320000003068N23100000
     
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    3031262074151/31.2 amp to 1.3 amp/0.6 amp1 (Female)3/4 (Male)15 1/16"9 1/4"7 3/8"3068N21000000003068N2120000003068N2210000
    38363227214951/20.8 amp to 1.7 amp/1.7 amp1 (Female)3/4 (Male)15 1/16"9 1/8"7 3/16"3068N22000000003068N2220000003068N2210000
    535346403323260512.2 amp to 3.3 amp/1.1 amp1 1/2 (Female)1 (Male)16 9/16"9 1/8"7 3/8"3068N23000000003068N2320000003068N23100000
    8282828180716185524.8 amp to 4.9 amp/2.4 amp2 (Male)1 1/2 (Male)20 11/16"10 3/8"10"3068N24000000003068N242000000003068N24100000
    1201201201201121059295537.8 amp to 8 amp/3.9 amp2 (Male)1 1/2 (Male)24 3/8"11 1/2"10 1/2"3068N26000000003068N252000000003068N25100000
     

    Circulation Pumps for Water and Oil

    Image of Product. Front orientation. Centrifugal Pumps. Circulation Pumps for Water and Oil.
    These pumps can be used to move water and lubricating oil in boiler feed systems, cooling towers, and heat exchangers. The housing rotates for vertical or horizontal discharge. They have totally enclosed fan-cooled (TEFC) motors for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    120V AC/230V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure
    47423425104575201/29 amp/5 amp1 Female NPT3/4 Female NPT13"8 3/4"8 5/8"8249K230000000
    797263513555275201 1/218 amp/9 amp1 1/4 Female NPT1 Female NPT14 1/4"8 3/4"8 5/8"8249K24000000
     
    120V AC/208V AC to 240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure
    90857869564015657520216 amp/8 amp to 9 amp1 1/4 Female NPT1 Female NPT15 1/8"8 7/8"8 1/2"8249K93000000
     
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure
    48423525104575201/22.7 amp to 2.8 amp/1.4 amp1 Female NPT3/4 Female NPT12 3/8"8 7/8"7 1/4"8249K211000000
    9085786956401565752025.5 amp to 5.8 amp/2.9 amp1 1/4 Female NPT1 Female NPT14 5/8"8 7/8"8 1/2"8249K9600000000
     
    Replacement Seals

    Stainless Steel Circulation Pumps for Chemicals

    Image of Product. Front orientation. Centrifugal Pumps. Stainless Steel Circulation Pumps for Chemicals.
    A 316 stainless steel housing sealed with fluoroelastomer resists mild chemicals and acids, such as coolant, oil, and phosphoric acid. These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. They are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    @ 70 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Solids
    Dia.
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    120V AC/240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire
    322210441001/8"501/35.6 amp/2.8 amp3/4 Female NPT1/2 Female NPT15"9"7 1/2"4320K8100000004320K110000000
    32323220621003/32"503/410.6 amp/5.3 amp1 1/4 Female NPT3/4 Female NPT16"9"7 3/4"4320K84000000004320K14000000
    363022541001/8"501/27.6 amp/3.8 amp3/4 Female NPT1/2 Female NPT15"9"7 1/2"4320K820000004320K12000000
    38332718591001/8"503/410.6 amp/5.3 amp3/4 Female NPT1/2 Female NPT15"9"7 1/2"4320K830000004320K13000000
    90826335601003/32"50112.6 amp/6.3 amp1 1/2 Female NPT1 1/4 Female NPT16"9"8 3/4"4320K95000000004320K14000000
     
    240V AC/460V AC, Three Phase—With Thermal Overload Protection
     
    Hardwire
    754715341003/16"5012.9 amp/1.4 amp1 1/2 Female NPT1 1/4 Female NPT16"9"8 3/4"4320K96000000004320K11000000
    95805520491003/16"501 1/23.9 amp/2 amp1 1/2 Female NPT1 1/4 Female NPT16"9"8 3/4"4320K88000000004320K13000000
    110100805828701003/32"501 1/23.9 amp/2 amp1 1/2 Female NPT1 1/4 Female NPT16"9"8 3/4"4320K87000000004320K15000000
    11555521003/16"5025.3 amp/2.7 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K91000000004320K16000000
    1309060821003/32"5025.3 amp/2.7 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K92000000004320K17000000
    1309555791003/16"5037.6 amp/3.8 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K94000000004320K19000000
    1408555881003/32"5037.6 amp/3.8 amp2 Female NPT1 1/2 Female NPT16"9"8 3/4"4320K93000000004320K18000000
     
    Repair Kits

    Low-Maintenance Plastic Circulation Pumps for Water and Coolants

    Eliminate seal wear and leakage with pumps that use magnets to turn the impeller. They’re often used with electroplating and photographic solutions. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps with Tube Connections (Top Intake)
    Image of Product. Front orientation. Centrifugal Pumps. Low-Maintenance Plastic Circulation Pumps for Water and Coolants, Pumps with Tube Connections (Top Intake).
    Flow
    Rate, gpm
    Intake
    Discharge
    Overall
    Max. Flow
    Rate, gpm
    @ 5 ft.
    of Head
    @ 10 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Connection
    Connection
    Type
    For Tube
    ID
    Connection
    Connection
    Type
    For Tube
    ID
    Lg.
    Wd.
    Ht.
    Each
    115V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    310.110.642035 to 1501/700.8Barbed
    Male Unthreaded1/2"Barbed
    Male Unthreaded1/2"6 3/4"3 3/4"4 7/8"9930K710000000
     
    Pumps with Tube Connections (Front Intake)
    Image of Product. Front orientation. Centrifugal Pumps. Low-Maintenance Plastic Circulation Pumps for Water and Coolants, Pumps with Tube Connections (Front Intake).
    Flow
    Rate, gpm
    Intake
    Discharge
    Overall
    Max. Flow
    Rate, gpm
    @ 5 ft.
    of Head
    @ 10 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Connection
    Connection
    Type
    For Tube
    ID
    Connection
    Connection
    Type
    For Tube
    ID
    Lg.
    Wd.
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    52732035 to 1501/500.94Barbed
    Male Unthreaded5/8"Barbed
    Male Unthreaded5/8"7 5/8"3 1/2"5 1/4"9930K370000000
    7751982035 to 1501/251.65Barbed
    Male Unthreaded5/8"Barbed
    Male Unthreaded5/8"8 1/4"3 1/2"5 1/4"9930K41000000
     
    Pumps with Pipe Connections (Front Intake)
    Image of Product. Front orientation. Centrifugal Pumps. Low-Maintenance Plastic Circulation Pumps for Water and Coolants, Pumps with Pipe Connections (Front Intake).
    Flow
    Rate, gpm
    Intake
    Discharge
    Overall
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Connection
    Connection
    Type
    Connection
    Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    115V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    95Not Rated16.172035 to 1501/201.4Threaded1/2 Female NPTThreaded1/2 Male NPT8 7/8"3 3/4"4 7/8"9930K720000000
    1411424.7102035 to 1501/101.7Threaded1 Female NPTThreaded1/2 Male NPT9 5/8"5 1/2"4 7/8"9930K73000000
     
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    8514.662035 to 1501/301.5Threaded1/2 Female NPTThreaded1/2 Male NPT8 1/2"4"4 3/8"9930K51000000
    118323.7102035 to 1501/122.4Threaded1/2 Female NPTThreaded1/2 Male NPT9"4"4 3/8"9930K53000000
    129221.992035 to 1501/122.4Threaded3/4 Female NPTThreaded1/2 Male NPT9 7/8"4"5"9930K63000000
    1512834.6152035 to 1501/82.1Threaded1/2 Female NPTThreaded1/2 Male NPT8 3/8"5 1/2"5 5/8"9930K54000000
    1713827.5112035 to 1501/82Threaded1 Female NPTThreaded1/2 Male NPT8 3/4"5 1/2"5 1/2"9930K65000000
     

    Circulation Pumps for Food and Beverage

    Image of Product. Front orientation. Centrifugal Pumps. Circulation Pumps for Food and Beverage.
    Commonly used in food, beverage, and dairy processing, these pumps are 3-A certified to meet sanitary design standards. They have quick-clamp intake and discharge connections to facilitate cleaning. The discharge connection rotates 360° for easy connection to your line. Motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Intake
    Discharge
    Overall
    Max. Flow
    Rate, gpm
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Connection
    Type
    Connection
    For Tube
    OD
    Connection
    Type
    Connection
    For Tube
    OD
    Lg.
    Wd.
    Ht.
    Each
    Each
    120V AC/240V AC, Single Phase—Without Thermal Overload Protection
     
    Hardwire
    7070404021700111.8 amp/5.9 ampFemaleQuick Clamp1 1/2"FemaleQuick Clamp1 1/2"17 1/2"6 1/2"7 1/4"49635K420000000002651N120000000
    80805033144001/27.4 amp/3.7 ampFemaleQuick Clamp1 1/2"FemaleQuick Clamp1 1/2"16 1/2"6 1/2"8 1/4"49635K41000000002651N11000000
     
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire
    707040402170013.6 amp/1.8 ampFemaleQuick Clamp1 1/2"FemaleQuick Clamp1 1/2"15 5/8"6 1/2"7 1/4"49635K52000000002651N12000000
    80805033144001/22 amp/1 ampFemaleQuick Clamp1 1/2"FemaleQuick Clamp1 1/2"15 7/8"6 1/2"8 1/4"49635K51000000002651N11000000
    Circulation Pump for Food and Beverage, 208-240/460V AC, 1/2 hp
    EachShips in 7-8 weeks
    855044248001 1/23.8 amp to 4 amp/1.9 ampFemaleQuick Clamp1 1/2"FemaleQuick Clamp1 1/2"16 1/4"6 1/2"7 1/4"49635K53000000002651N13000000
    9595623360025 amp to 5.3 amp/2.5 ampFemaleQuick Clamp1 1/2"FemaleQuick Clamp1 1/2"17 1/2"6 1/2"7 1/4"49635K54000000002651N14000000
     

    High-Head Circulation Pumps for Water

    Also known as booster pumps, these have a multistage impeller that propels water about two times higher and farther than standard circulation pumps. Use them in applications such as water delivery, irrigation, and pressure washing. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    120V AC/240V AC, Single Phase—Without Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. High-Head Circulation Pumps for Water.
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 60 ft.
    of Head
    @ 70 ft.
    of Head
    @ 80 ft.
    of Head
    @ 90 ft.
    of Head
    @ 100 ft.
    of Head
    @ 110 ft.
    of Head
    @ 120 ft.
    of Head
    @ 130 ft.
    of Head
    @ 140 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Hardwire—50 cP Maximum Viscosity
    2221201817151310163232110.6 amp/5.4 amp1 Female NPT1 Female NPT14 3/8"6 1/4"8 1/4"8134K25000000000
    22211917141281212323/47.6 amp/3.9 amp1 Female NPT1 Female NPT12"6 1/4"8 1/4"8134K2400000000
     
    208V AC to 240V AC/440V AC to 480V AC, Three Phase—Without Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. High-Head Circulation Pumps for Water.
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 130 ft.
    of Head
    @ 140 ft.
    of Head
    @ 150 ft.
    of Head
    @ 200 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Hardwire—50 cP Maximum Viscosity
    222222211525423237.7 amp to 8.2 amp/3.7 amp to 4 amp1 Female NPT1 Female NPT17 1/4"6 1/4"7 1/2"8134K34000000000
    323332232262323 2/58.5 amp to 8.9 amp/4 amp to 4.3 amp1 1/4 Female NPT1 Female NPT18 5/8"7"7 7/8"8134K2900000000
     

    Circulation Pumps for Water and Coolants

    Image of Product. Front orientation. Centrifugal Pumps. Circulation Pumps for Water and Coolants.
    Move water and coolants, such as ethylene glycol, in boiler feed systems, cooling towers, and heat exchangers. They have an open dripproof (ODP) motor for use in clean, dry, and well-ventilated environments. The housing rotates for vertical or horizontal discharge. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Repair Kits
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    120V AC/240V AC, 1/3 hp (Single Phase)—With Thermal Overload Protection
     
    Hardwire
    23211714115567516.8 amp/3.4 amp3/8 Female NPT3/8 Female NPT11 7/8"5 3/8"7 3/4"8249K4900000008249K510000008249K54000000
    332923167457516.8 amp/3.4 amp3/4 Female NPT1/2 Female NPT11 7/8"5 3/8"7 3/4"8249K530000008249K51000008249K5400000
    66553716357516.8 amp/3.4 amp1 1/4 Female NPT1 Female NPT11 7/8"6 3/8"7 3/4"8249K550000008249K5560000008249K5600000
     
    Replacement Seals

    Harsh-Environment Circulation Pumps for Water and Oil

    Image of Product. Front orientation. Centrifugal Pumps. Harsh Environment Circulation Pumps for Water and Oil.
    The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Use these pumps to move water and lubricating oil in boiler feed systems, cooling towers, and heat exchangers. The housing rotates for vertical or horizontal discharge. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created, which allows the pump to draw liquid upward.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    120V AC/208V AC to 240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—20 cP Maximum Viscosity
    696152422445275402003/410 amp/5 amp to 5.2 amp1 1/2 Female NPT1 1/2 Female NPT15 7/8"8 7/8"9 1/2"8249K87000000000
    1009179664875275402001 1/216.6 amp/8.3 amp to 9 amp1 1/2 Female NPT1 1/2 Female NPT16 1/2"8 7/8"9 1/2"8249K8900000000
     
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—20 cP Maximum Viscosity
    696152422445275402003/42.7 amp to 2.8 amp/1.35 amp1 1/2 Female NPT1 1/2 Female NPT15 3/8"8 7/8"9 1/2"8249K8800000000
    1009179664875275402001 1/24.2 amp to 4.3 amp/2.2 amp1 1/2 Female NPT1 1/2 Female NPT16 3/8"8 7/8"9 1/2"8249K9100000000
    1301231139982611663754020025.5 amp to 5.8 amp/2.9 amp1 1/2 Female NPT1 1/2 Female NPT17 3/8"8 7/8"9 1/2"8249K9200000000
     
    Replacement Seals

    Self-Priming Circulation Pumps for Water and Coolants

    Image of Product. Front orientation. Centrifugal Pumps. Self-Priming Circulation Pumps for Water and Coolants.
    Drain underground tanks and process wastewater with pumps that can be installed up to 20 ft. above your liquid source. They have an open dripproof (ODP) motor for use in clean, dry, and well-ventilated environments. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Repair Kits
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    @ 70 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    120V AC/240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    4744374875401801/37 amp/4 amp1 Female NPT1 Female NPT16 7/8"6 7/8"7 1/4"99435K45000000099435K451000000———0
    7060496275401801/29 amp/5 amp1 1/2 Female NPT1 1/2 Female NPT16 3/4"7 3/8"10"99435K21000000———099435K22000000
    7556456575401801/29 amp/5 amp1 1/4 Female NPT1 1/4 Female NPT17"6 7/8"7 1/4"99435K4700000099435K47100000———0
    8252356575401803/413 amp/6 amp1 1/4 Female NPT1 1/4 Female NPT17 1/2"6 7/8"7 1/4"99435K5100000099435K51100000———0
    8354427175401803/413 amp/6 amp1 1/2 Female NPT1 1/2 Female NPT17 1/4"7 3/8"10"99435K23000000———0———0
    85574425707540180114 amp/7 amp1 1/4 Female NPT1 1/4 Female NPT18 3/8"6 7/8"7 1/4"99435K5400000099435K54100000———0
    1258873539375401801 1/219 amp/10 amp1 1/2 Female NPT1 1/2 Female NPT18"7 3/8"10"99435K25000000———099435K2200000
    1309280601007540180220 amp/10 amp1 1/2 Female NPT1 1/2 Female NPT18"7 3/8"10"99435K2700000099435K62100000———0
    13010187709575401801 1/219 amp/10 amp2 Female NPT2 Female NPT19 3/8"7 1/2"11 1/8"99435K6600000099435K66100000———0
    135967757987540180220 amp/10 amp2 Female NPT2 Female NPT19 3/8"7 1/2"11 1/8"99435K7100000099435K71100000———0
     
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    1258873539375401801 1/26 amp/3 amp1 1/2 Female NPT1 1/2 Female NPT17 1/2"7 3/8"10"99435K33000000———0———0
    13010187709575401801 1/26 amp/3 amp2 Female NPT2 Female NPT18 7/8"7 1/2"11 1/8"99435K6700000099435K67100000———0
    13596775785754018027 amp/4 amp2 Female NPT2 Female NPT19 3/8"7 1/2"11 1/8"99435K35000000———0———0
    1621201008087754018039 amp/5 amp2 Female NPT2 Female NPT20 3/8"7 1/2"11 1/8"99435K730000004320K23000000———0
     

    High-Flow Harsh-Environment Self-Priming Circulation Pumps for Water and Coolants

    Image of Product. Front orientation. Centrifugal Pumps. High-Flow Harsh Environment Self-Priming Circulation Pumps for Water and Coolants.
    A powerful motor provides twice the flow rate of other self-priming circulation pumps. It is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Install these pumps up to 20 ft. above your liquid source to drain underground tanks and process wastewater. They are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    @ 70 ft.
    of Head
    @ 80 ft.
    of Head
    @ 90 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    375265225200160110125401807 1/220 amp/10 amp3 Female NPT3 Female NPT26 5/8"12"11 7/8"99435K4100000000099435K4110000000
    3752101801409012540180514 amp/7 amp3 Female NPT3 Female NPT26 5/8"12"11 7/8"99435K390000000099435K38000000
    375165130756512540180310 amp/5 amp3 Female NPT3 Female NPT26 5/8"12"11 7/8"99435K370000000099435K36000000
     

    Extended-Life Immersion Circulation Pumps for Water and Coolants

    A sealless construction means these pumps have few moving parts that can fail and shorten service life. The intake can be completely submerged in liquid. Pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. They are gravity fed and require an elevated liquid source. Do not run dry.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    With Inlet and Tube Connections
    Image of Product. Front orientation. Contains Annotated. Centrifugal Pumps. Extended-Life Immersion Circulation Pumps for Water and Coolants, With Inlet and Tube Connections.
    Discharge
    Overall
    Max. Flow
    Rate, gpm
    Flow Rate @ 10 ft.
    of Head, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Electrical
    Connection Type
    Power,
    hp
    Current,
    amp
    Intake Inlet
    Type
    Connection
    Connection Type
    For Tube
    OD
    Dia.
    Ht.
    Shaft
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
    1171357050 to 150Plug In1/152.4ScreenedPush to ConnectFemale Unthreaded5/8"5"13"8 1/8"4336K410000000
    1171357050 to 150Plug In1/152.4ScreenedPush to ConnectFemale Unthreaded5/8"5"15"10 1/2"4336K51000000
     
    240V AC, Single Phase—With Thermal Overload Protection
    1171357050 to 150Plug In1/151.2ScreenedPush to ConnectFemale Unthreaded5/8"5"10"5 1/8"4336K32000000
    1171357050 to 150Plug In1/151.2ScreenedPush to ConnectFemale Unthreaded5/8"5"13"8 1/8"4336K42000000
    1171357050 to 150Plug In1/151.2ScreenedPush to ConnectFemale Unthreaded5/8"5"15"10 1/2"4336K52000000
     
    Replacement Impellers
    With Pipe Connections
    Image of Product. Front orientation. Centrifugal Pumps. Extended-Life Immersion Circulation Pumps for Water and Coolants, With Pipe Connections.
    12V DC—12V DC pumps must be fully submerged in liquid to run.
    Discharge
    Overall
    Max. Flow
    Rate, gpm
    Flow Rate @ 10 ft.
    of Head, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Electrical
    Connection Type
    Power
    Current,
    amp
    Intake Connection
    Type
    Connection
    Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    12V DC—Without Thermal Overload Protection
    2.70.51150532 to 120HardwireFractional0.91/4 Male NPTThreaded1/4 Male NPT4 15/16"2 1/4"3 1/4"3128N410000000
     
    24V DC—Without Thermal Overload Protection
    2.70.51150532 to 190HardwireFractional0.51/4 Male NPTThreaded1/4 Male NPT4 15/16"2 1/4"3 1/4"3128N12000000
     
    Replacement Impellers

    Circulation Pumps for Fuel and Flammable Liquid

    Pump fuel and flammable liquids, such as isopropyl alcohol and xylene. These pumps have an explosion-proof motor that is rated for environments where hazardous material is present. Maximum temperature is 250° F or the boiling point of the liquid being pumped, whichever is lower. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    With Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. Circulation Pumps for Fuel and Flammable Liquid.
    Pumps
    Impellers
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    120V AC/208V AC to 240V AC, Single Phase—Hardwire
    25312519131621502641/27.4 amp/3.7 amp3/4 Female NPT1/2 Female NPT15 5/8"10 7/8"7 1/2"8205K440000000008205K4210000000
     
    208V AC to 240V AC/460V AC, Three Phase—Hardwire
    25312519131621502641/22.2 amp to 2.4 amp/1.1 amp3/4 Female NPT1/2 Female NPT15 5/8"10 7/8"7 1/2"8205K42000000008205K421000000
    100786448106415026412.8 amp/1.4 amp1 1/2 Female NPT1 Female NPT15 1/4"10 7/8"8 1/2"8205K43000000008205K431000000
     
    Repair Kits
    Without Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. Circulation Pumps for Fuel and Flammable Liquid.
    Pumps
    Impellers
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    120V AC/208V AC to 240V AC, Single Phase—Hardwire
    15104461502641/34.8 amp/2.4 amp3/4 Female NPT1/2 Female NPT15 1/2"10 7/8"7 1/2"8205K410000000008205K4110000000
    1007864481064150264112 amp/6 amp1 1/2 Female NPT1 Female NPT17 1/4"10 7/8"8 1/2"8205K45000000008205K431000000
     
    208V AC to 240V AC/460V AC, Three Phase—Hardwire
    1151009060811502641 1/24.6 amp to 5 amp/2.3 amp1 1/2 Female NPT1 Female NPT16 3/8"11 7/8"8 1/2"8205K46000000008205K461000000
    1251149878186915026425.4 amp to 5.7 amp/2.7 amp2 Female NPT1 1/2 Female NPT17 1/8"11 7/8"8 1/2"8205K47000000008205K471000000
    140120477515026437.6 amp to 8.1 amp/3.8 amp2 Female NPT1 1/2 Female NPT17 1/8"11 7/8"8 1/2"8205K48000000008205K461000000
     
    Repair Kits

    Adjustable-Flow Inline Circulation Pumps for Water

    Image of Product. Front orientation. Centrifugal Pumps. Adjustable-Flow Inline Circulation Pumps for Water.
    Accommodate performance changes in your system with a three-speed switch that adjusts flow rate. Install these pumps directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. They have an open dripproof (ODP) motor for use in clean, dry, and well-ventilated environments. Mount horizontally with the included pipe connectors. Do not run dry or use with solids. Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    304 Stainless Steel Housing—Pumps with 304 stainless steel housing are lead free.
    Flow Rate (Speed No.)
    Overall
    Max.
    @ 10 ft. of Head
    @ 20 ft. of Head
    Current (Speed No.)
    Max. ft. of
    Head, ft.
    Power,
    hp
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    120V AC (Single Phase), -10% to 10% Flow Adjustment Rate—Without Thermal Overload Protection
     
    Cast Iron Housing, 1 cP Maximum Viscosity—Hardwire
    6 gpm (1), 11 gpm (2), 18 gpm (3)2 gpm (1), 6 gpm (2), 11 gpm (3)1 gpm (2), 3 gpm (3)0.7 amp (1), 0.8 amp (2), 1 amp (3)241/61 Female NPT1 Female NPT6"5"6 3/8"1785N4920000000
    6 gpm (1), 11 gpm (2), 18 gpm (3)2 gpm (1), 6 gpm (2), 11 gpm (3)1 gpm (2), 3 gpm (3)0.7 amp (1), 0.8 amp (2), 1 amp (3)241/61 1/4 Female NPT1 1/4 Female NPT6"5"6 3/8"1785N493000000
    6 gpm (1), 11 gpm (2), 18 gpm (3)2 gpm (1), 6 gpm (2), 11 gpm (3)1 gpm (2), 3 gpm (3)0.7 amp (1), 0.8 amp (2), 1 amp (3)241/61 1/2 Female NPT1 1/2 Female NPT6"5"6 3/8"1785N494000000
    7 gpm (1), 13 gpm (2), 18 gpm (3)2 gpm (1), 6 gpm (2), 9 gpm (3)Not Rated0.5 amp (1), 0.6 amp (2), 0.8 amp (3)181/81 Female NPT1 Female NPT6"5"6 3/8"1785N22000000
    7 gpm (1), 13 gpm (2), 18 gpm (3)2 gpm (1), 6 gpm (2), 9 gpm (3)Not Rated0.5 amp (1), 0.6 amp (2), 0.8 amp (3)181/81 1/4 Female NPT1 1/4 Female NPT6"5"6 3/8"1785N393000000
    7 gpm (1), 13 gpm (2), 18 gpm (3)2 gpm (1), 6 gpm (2), 9 gpm (3)Not Rated0.5 amp (1), 0.6 amp (2), 0.8 amp (3)181/81 1/2 Female NPT1 1/2 Female NPT6"5"6 3/8"1785N23000000
     
    304 Stainless Steel Housing, 1 cP Maximum Viscosity—Hardwire
    6 gpm (1), 11 gpm (2), 18 gpm (3)2 gpm (1), 6 gpm (2), 11 gpm (3)1 gpm (2), 3 gpm (3)0.7 amp (1), 0.8 amp (2), 1 amp (3)241/61 Female NPT1 Female NPT6"5"6 3/8"1785N232000000
    6 gpm (1), 11 gpm (2), 18 gpm (3)2 gpm (1), 6 gpm (2), 11 gpm (3)1 gpm (2), 3 gpm (3)0.7 amp (1), 0.8 amp (2), 1 amp (3)241/61 1/4 Female NPT1 1/4 Female NPT6"5"6 3/8"1785N233000000
    6 gpm (1), 11 gpm (2), 18 gpm (3)2 gpm (1), 6 gpm (2), 11 gpm (3)1 gpm (2), 3 gpm (3)0.7 amp (1), 0.8 amp (2), 1 amp (3)241/61 1/2 Female NPT1 1/2 Female NPT6"5"6 3/8"1785N244000000
    7 gpm (1), 13 gpm (2), 18 gpm (3)2 gpm (1), 6 gpm (2), 9 gpm (3)Not Rated0.5 amp (1), 0.6 amp (2), 0.8 amp (3)181/81 Female NPT1 Female NPT6"5"6 3/8"1785N412000000
    7 gpm (1), 13 gpm (2), 18 gpm (3)2 gpm (1), 6 gpm (2), 9 gpm (3)Not Rated0.5 amp (1), 0.6 amp (2), 0.8 amp (3)181/81 1/4 Female NPT1 1/4 Female NPT6"5"6 3/8"1785N413000000
    7 gpm (1), 13 gpm (2), 18 gpm (3)2 gpm (1), 6 gpm (2), 9 gpm (3)Not Rated0.5 amp (1), 0.6 amp (2), 0.8 amp (3)181/81 1/2 Female NPT1 1/2 Female NPT6"5"6 3/8"1785N414000000
    30 gpm (1), 45 gpm (2), 52 gpm (3)2 gpm (1), 18 gpm (2), 25 gpm (3)Not Rated1.4 amp (1), 1.6 amp (2), 1.9 amp (3)141/31 Female NPT1 Female NPT6 5/8"5 1/2"8 1/2"1785N321000000
    30 gpm (1), 45 gpm (2), 52 gpm (3)2 gpm (1), 18 gpm (2), 25 gpm (3)Not Rated1.4 amp (1), 1.6 amp (2), 1.9 amp (3)141/31 1/4 Female NPT1 1/4 Female NPT6 5/8"5 1/2"8 1/2"1785N322000000
    30 gpm (1), 45 gpm (2), 52 gpm (3)2 gpm (1), 18 gpm (2), 25 gpm (3)Not Rated1.4 amp (1), 1.6 amp (2), 1.9 amp (3)141/31 1/2 Female NPT1 1/2 Female NPT6 5/8"5 1/2"8 1/2"1785N323000000
     
    240V AC (Single Phase), -6% to 6% Flow Adjustment Rate—Without Thermal Overload Protection
     
    Cast Iron Housing, 1 cP Maximum Viscosity—Hardwire
    19 gpm (1), 28 gpm (2), 30 gpm (3)7 gpm (1), 19 gpm (2), 23 gpm (3)2 gpm (1), 10 gpm (2), 13 gpm (3)0.8 amp (1), 0.85 amp (2), 0.9 amp (3)311/41 Female NPT1 Female NPT6 3/8"5 1/2"6 1/2"1785N292000000
    19 gpm (1), 28 gpm (2), 30 gpm (3)7 gpm (1), 19 gpm (2), 23 gpm (3)2 gpm (1), 10 gpm (2), 13 gpm (3)0.8 amp (1), 0.85 amp (2), 0.9 amp (3)311/41 1/4 Female NPT1 1/4 Female NPT6 3/8"5 1/2"6 1/2"1785N293000000
    19 gpm (1), 28 gpm (2), 30 gpm (3)7 gpm (1), 19 gpm (2), 23 gpm (3)2 gpm (1), 10 gpm (2), 13 gpm (3)0.8 amp (1), 0.85 amp (2), 0.9 amp (3)311/41 1/2 Female NPT1 1/2 Female NPT6 3/8"5 1/2"6 1/2"1785N294000000
     
    304 Stainless Steel Housing, 1 cP Maximum Viscosity—Hardwire
    19 gpm (1), 28 gpm (2), 30 gpm (3)7 gpm (1), 19 gpm (2), 23 gpm (3)2 gpm (1), 10 gpm (2), 13 gpm (3)0.8 amp (1), 0.85 amp (2), 0.9 amp (3)311/41 Female NPT1 Female NPT6 3/8"5 1/2"6 1/2"1785N222000000
    19 gpm (1), 28 gpm (2), 30 gpm (3)7 gpm (1), 19 gpm (2), 23 gpm (3)2 gpm (1), 10 gpm (2), 13 gpm (3)0.8 amp (1), 0.85 amp (2), 0.9 amp (3)311/41 1/4 Female NPT1 1/4 Female NPT6 3/8"5 1/2"6 1/2"1785N223000000
    19 gpm (1), 28 gpm (2), 30 gpm (3)7 gpm (1), 19 gpm (2), 23 gpm (3)2 gpm (1), 10 gpm (2), 13 gpm (3)0.8 amp (1), 0.85 amp (2), 0.9 amp (3)311/41 1/2 Female NPT1 1/2 Female NPT6 3/8"5 1/2"6 1/2"1785N23400000000
     

    Harsh-Environment Self-Priming Circulation Pumps for Water and Coolants

    Image of Product. Front orientation. Centrifugal Pumps. Harsh Environment Self-Priming Circulation Pumps for Water and Coolants.
    The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Install these pumps up to 20 ft. above your liquid source to drain underground tanks and process wastewater. They are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    @ 70 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    1208270581007540180316 amp1 1/2 Female NPT1 1/2 Female NPT19 1/2"9 1/8"10"99435K64000000099435K641000000
     
    120V AC/240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    824934657540180112 amp/6 amp1 1/4 Female NPT1 1/4 Female NPT18"8 7/8"7 1/4"99435K5200000099435K51100000
    825340237075401801 1/218 amp/9 amp1 1/4 Female NPT1 1/4 Female NPT18 1/2"8 7/8"7 1/4"99435K5500000099435K54100000
    8249365875401803/49 amp/5 amp1 1/4 Female NPT1 1/4 Female NPT17 7/8"8 7/8"7 1/4"99435K4800000099435K47100000
    8242325275401801/29 amp/5 amp1 Female NPT1 Female NPT17 3/8"8 7/8"7 1/4"99435K4600000099435K45100000
    120655442957540180222 amp/11 amp1 1/2 Female NPT1 1/2 Female NPT19"9 1/8"10"99435K6200000099435K62100000
    1205444807540180112 amp/6 amp1 1/2 Female NPT1 1/2 Female NPT17 3/4"9 1/8"10"99435K5900000099435K59100000
    12052467075401803/49 amp/5 amp1 1/2 Female NPT1 1/2 Female NPT17 1/2"9 1/8"10"99435K5700000099435K57100000
    150776449827540180222 amp/11 amp2 Female NPT2 Female NPT20 3/8"9 1/8"11 1/8"99435K6800000099435K66100000
     
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    82493465754018014 amp/2 amp1 1/4 Female NPT1 1/4 Female NPT16 5/8"8 7/8"8 5/8"99435K5300000099435K53100000
    825340237075401801 1/25 amp/3 amp1 1/4 Female NPT1 1/4 Female NPT18 3/8"8 7/8"8 5/8"99435K5600000099435K56100000
    8249365875401803/43 amp/2 amp1 1/4 Female NPT1 1/4 Female NPT17 3/8"8 7/8"8 5/8"99435K4900000099435K49100000
    12065544295754018026 amp/3 amp1 1/2 Female NPT1 1/2 Female NPT18 1/2"9 1/8"10"99435K6300000099435K63100000
    120827058100754018038 amp/4 amp1 1/2 Female NPT1 1/2 Female NPT19"9 1/8"10"99435K6500000099435K65100000
    120544480754018014 amp/2 amp1 1/2 Female NPT1 1/2 Female NPT16 3/8"9 1/8"10"99435K6100000099435K61100000
    12052467075401803/43 amp/2 amp1 1/2 Female NPT1 1/2 Female NPT17"9 1/8"10"99435K5800000099435K58100000
    15076604382754018038 amp/4 amp2 Female NPT2 Female NPT20 3/8"9 1/8"11 1/8"99435K720000000099435K72100000
    15077644982754018026 amp/3 amp2 Female NPT2 Female NPT19 7/8"9 1/8"11 1/8"99435K6900000099435K67100000
     

    High-Flow Harsh-Environment Low-Maintenance Plastic Circulation Pumps for Water and Coolants

    Image of Product. Front orientation. Centrifugal Pumps. High-Flow Harsh Environment Low-Maintenance Plastic Circulation Pumps for Water and Coolants.
    A powerful motor provides twice the flow rate of other extended-life circulation pumps. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Magnets turn the impeller to eliminate seal wear and leakage for a long service life. These pumps are often used with electroplating and photographic solutions. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    120V AC/240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—9 cP Maximum Viscosity
    5341332816050351503/410 amp/5 amp1 1/2 Female NPT1 Male NPT17 7/8"9"9"9929K560000000009929K580000000
     
    Hardwire—20 cP Maximum Viscosity
    32251940.517351501/35 amp/2.5 amp1 Female NPT3/4 Male NPT16 1/4"8 7/8"7"99095K5400000000———0
    383228215121351501/29.4 amp/4.7 amp1 Female NPT3/4 Male NPT16 1/4"8 7/8"7"99095K5500000000———0
    534237281858.925351503/411.8 amp/5.9 amp1 1/2 Female NPT1 Male NPT17 1/4"8 5/8"8 1/2"99095K5700000000———0
     
    240V AC/460V AC, Three Phase—With Thermal Overload Protection
     
    Hardwire—20 cP Maximum Viscosity
    383228215121351501/21.8 amp/0.9 amp1 Female NPT3/4 Male NPT15 1/4"8 3/4"7"99095K5600000000———0
    534237281858.925351503/42.9 amp/1.5 amp1 1/2 Female NPT1 Male NPT17 1/4"8 5/8"8 5/8"99095K5800000000———0
     

    High-Flow Inline Circulation Pumps for Water

    Image of Product. Front orientation. Centrifugal Pumps. High-Flow Inline Circulation Pumps for Water.
    A high-horsepower motor handles four times the flow and twice the pressure of other inline circulation pumps. Install these pumps directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. Mount horizontally or vertically. The motor cannot face downward; it’s cooled by the water being pumped. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Required Pipe
    Connectors
    Flow
    Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Pair
    120V AC/208V AC to 240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    100714745145352803/49.6 amp/4.8 amp to 5.3 amp1 1/2 Female NPT1 1/2 Female NPT9 1/4"11 1/2"17 3/4"8115K4200000000067705K49000000
    1501229046145352801 1/217 amp/8.6 amp to 9.5 amp2 Female NPT2 Female NPT9 3/4"14"20 1/2"8115K43000000008115K61000000
     
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    100714745145352803/42.3 amp to 2.4 amp/1.2 amp1 1/2 Female NPT1 1/2 Female NPT8 5/8"11 1/2"15 7/8"8115K520000000067705K4900000
    1501229046145352801 1/24.6 amp to 4.7 amp/2.3 amp2 Female NPT2 Female NPT8 1/2"14"17 3/8"8115K53000000008115K61000000
    240188135481453528037.7 amp to 8.4 amp/3.9 amp3 Female NPT3 Female NPT8 3/8"19"24 1/8"8115K34000000008115K62000000
     

    High-Head Circulation Pumps for Water, Coolants, and Oil

    Propel liquid higher and farther than standard circulation pumps. They're commonly used with chillers, heat exchangers, and boiler feed systems. The motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    120V AC/208V AC to 240V AC, Single Phase—With Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. High-Head Circulation Pumps for Water, Coolants, and Oil.
    Pumps
    Impellers
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 80 ft.
    of Head
    @ 90 ft.
    of Head
    @ 100 ft.
    of Head
    @ 150 ft.
    of Head
    @ 200 ft.
    of Head
    @ 250 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    Hardwire—52 cP Maximum Viscosity
    33332165701/37.5 amp/4 amp1 Female NPT1 Female NPT13 5/8"6 1/2"6 7/8"43195K5100000000043195K5120000000
    44444180751/29.5 amp/5.1 amp1 Female NPT1 Female NPT13 5/8"6 1/2"6 7/8"43195K520000000043195K522000000
    66665542801203/410.3 amp/5.2 amp1 Female NPT1 Female NPT14 1/8"6 1/2"6 7/8"43195K530000000043195K532000000
     
    Repair Kits
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
    Image of Product. Front orientation. Centrifugal Pumps. High-Head Circulation Pumps for Water, Coolants, and Oil.
    Pumps
    Impellers
    Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 80 ft.
    of Head
    @ 90 ft.
    of Head
    @ 120 ft.
    of Head
    @ 130 ft.
    of Head
    @ 140 ft.
    of Head
    @ 150 ft.
    of Head
    @ 200 ft.
    of Head
    @ 250 ft.
    of Head
    @ 300 ft.
    of Head
    @ 350 ft.
    of Head
    Max. ft. of
    Head, ft.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    Hardwire—52 cP Maximum Viscosity
     
    165 psi Maximum Pressure
    1099888877653801 1/24.6 amp to 4.8 amp/2.4 amp1 Female NPT1 Female NPT15 1/8"6 1/2"8 5/8"43195K5600000000043195K5620000000
     
    170 psi Maximum Pressure
    131212111111111098740025.2 amp to 5.6 amp/2.6 amp1 Female NPT1 Female NPT15 1/2"6 1/2"8 5/8"43195K570000000043195K572000000
     
    Repair Kits

    Harsh-Environment Low-Maintenance Plastic Circulation Pumps for Water and Coolants

    Image of Product. Front orientation. Centrifugal Pumps. Harsh Environment Low-Maintenance Plastic Circulation Pumps for Water and Coolants.
    These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. The impeller is turned with magnets to eliminate seal wear and leakage for a long service life. Pumps are often used with electroplating and photographic solutions. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 5 ft.
    of Head
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In—20 cP Maximum Viscosity
    10616.37351501/251.3 amp1/2 Female NPT1/2 Male NPT9"4"5"99095K510000000———0
    1412424.310351501/101.7 amp1 Female NPT1/2 Male NPT10 7/8"5 1/2"5"99095K52000000———0
     
    240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—20 cP Maximum Viscosity
    107516.37351501/200.8 amp1/2 Female NPT1/2 Male NPT8 1/2"4"4 3/8"9930K52000000———0
    1412424.310351501/100.7 amp1 Female NPT1/2 Male NPT10 5/8"5 1/2"5"9930K64000000———0
     
    120V AC/240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—5 cP Maximum Viscosity
    181715112950351501/52.6 amp/1.3 amp1 Female NPT1/2 Male NPT12 1/4"7 1/4"7"9929K550000009929K570000000
     
    Plug In—20 cP Maximum Viscosity
    20171129.310351501/83 amp/1.4 amp1 Female NPT1/2 Male NPT11 1/4"5 1/4"7 3/8"9930K66000000———0
     

    Circulation Pumps without Motor

    Image of Product. Front orientation. Centrifugal Pumps. Circulation Pumps without Motor.
    Also known as centrifugal pumps, these send a high flow of liquid through a pipeline or a closed circuit. They’re often used in heating and cooling applications, as well as for tank filling and emptying. Connect them to a spark-free air motor for hazardous locations, or use an electric motor with a speed reducer or belt pulley to alter pump speed. Recommended for use with a NEMA 56C frame motor. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Shaft
    Overall
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Max. Temp.,
    ° F
    Req. Power,
    hp
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Dia.
    Ctr.-to-Base
    Lg.
    Ht.
    Wd.
    Lg.
    Each
    For 1,750 rpm to 4,000 rpm Motor Speed
    355875232003/53/4 Female NPT1/2 Female NPT1 3/8"5/8"3 1/4"5 1/8"5 3/4"6 5/8"4284K110000000
    8567752320021 1/4 Female NPT1 Female NPT1 3/8"5/8"3 1/4"5 3/4"6 1/2"6 3/4"4284K12000000
     

    Self-Priming Stainless Steel Circulation Pumps for Chemicals

    Image of Product. Front orientation. Centrifugal Pumps. Self-Priming Stainless Steel Circulation Pumps for Chemicals.
    Self-priming up to 6 ft., these pumps have a stainless steel housing sealed with PTFE to resist chemicals such as ammonia. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    120V AC/240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—20 cP Maximum Viscosity
    6854415075402503/49 amp/5 amp1 1/2 Female NPT1 1/2 Female NPT15 3/4"8 3/4"9 1/2"1019N21000000000
    10065455075402501 1/218 amp/9 amp1 1/2 Female NPT1 1/2 Female NPT16 1/2"8 3/4"9 1/2"1019N2300000000
     
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—20 cP Maximum Viscosity
    6854415075402503/43 amp/2 amp1 1/2 Female NPT1 1/2 Female NPT15 1/4"8 3/4"9 1/2"1019N2200000000
    10065455075402501 1/25 amp/3 amp1 1/2 Female NPT1 1/2 Female NPT16 1/4"8 3/4"9 1/2"1019N2400000000
    13282601463754025026 amp/3 amp1 1/2 Female NPT1 1/2 Female NPT17 1/4"8 3/4"9 1/2"1019N2500000000
     

    Circulation Pumps for Water Sprinklers

    Image of Product. Front orientation. Centrifugal Pumps. Circulation Pumps for Water Sprinklers.
    These pumps have high flow rates for irrigation and landscaping. The open dripproof (ODP) motor is for use in clean, dry, and well-ventilated environments. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward. They can be mounted up to 25 ft. above your liquid source.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    @ 70 ft.
    of Head
    @ 80 ft.
    of Head
    @ 90 ft.
    of Head
    @ 100 ft.
    of Head
    @ 110 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    120V AC/240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    56535046433733251086040140114.8 amp/7.4 amp2 Female NPT1 1/2 Female NPT18 5/8"10 3/16"11 7/8"4011K110000000
    69646055504536301811760401401 1/219.2 amp/9.6 amp2 Female NPT1 1/2 Female NPT19 3/4"10 3/16"11 7/8"4011K22000000
    7765625754474235261326040140224 amp/12 amp2 Female NPT2 Female NPT21"11 1/4"12 3/8"4011K4400000000
     

    Ultra-Quiet Circulation Pumps for Water

    Image of Product. Front orientation. Centrifugal Pumps. Ultra-Quiet Circulation Pumps for Water.
    Instead of a fan-cooled motor, these pumps have an integrated motor that's cooled by the liquid being pumped for virtually silent operation and a long service life. Also known as canned motor pumps, they're commonly used in chiller systems and aquariums. They can be mounted horizontally or vertically, but the motor must be below the impeller. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    Flow Rate @ 10 ft.
    of Head, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    118192940140Fractional0.57 amp3/4 Male NPT3/4 Male NPT6"4 3/8"4 7/8"9907T4010000000
     
    Plug In—1 cP Maximum Viscosity
    118232940140Fractional0.52 amp3/4 Male NPT3/4 Male NPT6"4 3/8"4 7/8"9907T302000000
     

    Circulation Pumps for Hot Oil

    Image of Product. Front orientation. Centrifugal Pumps. Circulation Pumps for Hot Oil.
    Transfer hot oil up to 650° F in demanding applications such as plastic mold injecting and chemical processing. These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. They are gravity fed and require an elevated liquid source. Do not run dry or use with solids. They cannot be sold to the regions listed due to local energy efficiency requirements.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Flow Rate, gpm
    Temp.
    Overall
    Max. Flow
    Rate, gpm
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    @ 70 ft.
    of Head
    @ 80 ft.
    of Head
    @ 90 ft.
    of Head
    @ 100 ft.
    of Head
    @ 110 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.,
    ° F
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Cannot Be Sold To
    Each
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—32 cP Maximum Viscosity
    57544565150Not Rated65013.6 amp/1.8 amp1 1/2 Female NPT1 1/4 Female NPT19"9"10"California, Canada1020N11000000000
    66554380150Not Rated6501 1/24.6 amp/2.3 amp1 1/2 Female NPT1 1/4 Female NPT20"9"10"California, Canada1020N1200000000
    75655540100150Not Rated65026 amp/3 amp1 1/2 Female NPT1 1/4 Female NPT21"10"10"Canada1020N1300000000
    86756554128150Not Rated65037.6 amp/3.8 amp1 1/2 Female NPT1 1/4 Female NPT22"9"10"California, Canada1020N1400000000
     

    Extended-Life Inline Circulation Pumps for Water

    Image of Product. Front orientation. Centrifugal Pumps. Extended-Life Inline Circulation Pumps for Water.
    Eliminate seal wear and leakage—these pumps have magnets that turn the impeller for a long service life. Install them directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. Mount vertically or horizontally. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Flow
    Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 5 ft.
    of Head
    @ 10 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In—1 cP Maximum Viscosity
    44.3150352501/1000.54 amp1/2 Male NPT1/2 Male NPT4 7/8"3 1/2"7 1/2"4161K110000000
    65312.1150352501/250.54 amp1/2 Male NPT1/2 Male NPT4 7/8"3 1/2"7 1/2"4161K21000000
     

    Immersion Circulation Pumps for Coolants

    Image of Product. Front orientation. Centrifugal Pumps. Immersion Circulation Pumps for Coolants.
    Commonly used in machine tool coolant tanks, these pumps have an intake that can be completely submerged in liquid. A universal mounting plate fits machine tools from manufacturers such as Fuji, Mitsubishi, Toshiba, Hitachi, and Yasukawa. Motor is totally enclosed with sealed bearings for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. They can run dry.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Inlet
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Shaft
    Ht.
    Each
    Each
    120V AC/240V AC, Single Phase—Without Thermal Overload Protection
     
    Hardwire—90 cP Maximum Viscosity
    105135501801/80.7 amp/0.4 ampOpen3/8 Female NPT5 1/2"3 1/2"11 3/4"6"99875K2100000002640N13000000
    20201453313501801/43 amp/1.5 ampOpen1/2 Female NPT7 1/2"5"14 7/8"7 1/16"99875K310000002640N1400000
    3534271854218501801/26 amp/3 ampOpen3/4 Female NPT7 1/2"5 9/16"18 19/32"9 7/16"99875K410000002640N15000000
     
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—90 cP Maximum Viscosity
    105135501801/80.3 amp/0.2 ampOpen3/8 Female NPT5 1/2"3 1/2"11 3/4"6"99875K250000002640N1300000
    20201453313501801/40.9 amp/0.6 ampOpen1/2 Female NPT7 1/2"5"14 7/8"7 1/16"99875K350000002640N1400000
    3534271854218501801/22 amp/1.4 ampOpen3/4 Female NPT7 1/2"5 9/16"18 19/32"9 7/16"99875K440000002640N15000000
    4552453525105523501803/42.6 amp/1.6 ampOpen1 Female NPT8 3/8"6"20 29/32"11 15/32"99875K46000000002640N16000000
    5050403018160255018013.2 amp/2 ampOpen1 Female NPT8 3/8"6"22 3/32"11 15/32"99875K48000000002640N16000000
     

    Remote-Mount Circulation Pumps for Water and Coolants

    Image of Product. Front orientation. Centrifugal Pumps. Remote-Mount Circulation Pumps for Water and Coolants.
    Use when space is limited—these pumps connect to a pipe coming from your tank so you can place the pump in another location. Mount above or below the liquid level. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    120V AC/240V AC, Single Phase—Without Thermal Overload Protection
     
    Hardwire—90 cP Maximum Viscosity
    105135501401/80.7 amp/0.4 amp3/8 Female NPT3/8 Female NPT6 1/2"5 1/2"6 7/8"99875K1100000002640N13000000
    2020143313501401/43 amp/1.5 amp3/4 Female NPT3/4 Female NPT8"7 1/16"9 5/32"99875K81000000———0
    32271854218501401/26 amp/3 amp3/4 Female NPT3/4 Female NPT8 3/8"7 1/4"11 3/4"99875K910000002640N15000000
     
    240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—90 cP Maximum Viscosity
    105135501401/80.3 amp/0.2 amp3/8 Female NPT3/8 Female NPT6 1/2"5 1/2"6 7/8"99875K150000002640N1300000
    2020143313501401/40.9 amp/0.6 amp3/4 Female NPT3/4 Female NPT8"7 1/16"9 5/32"99875K850000002640N1400000
    32271854218501401/22 amp/1.4 amp3/4 Female NPT3/4 Female NPT8 3/8"7 1/4"11 3/4"99875K940000002640N15000000
    433525105523501403/42.6 amp/1.6 amp1 Female NPT1 Female NPT8 5/8"8 1/16"12 1/4"99875K96000000002640N16000000
    48403018160255014013.2 amp/2 amp1 Female NPT1 Female NPT8 1/2"8"13 31/32"99875K98000000002640N16000000
     
    Repair Kits

    Compact Inline Circulation Pumps for Water

    Image of Product. Front orientation. Centrifugal Pumps. Compact Inline Circulation Pumps for Water.
    Use these pumps in pipelines with limited clearance. Install directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. Pumps mount horizontally or vertically with required pipe connectors. The motor cannot face downward; it’s cooled by the water being pumped. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Flow Rate, gpm
    Overall
    Mounting
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Viscosity,
    cP
    Power,
    hp
    Current,
    amp
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    No. of
    Holes
    Hole
    Dia.
    Each
    120V AC, Single Phase—Without Thermal Overload Protection
     
    Hardwire
    31221353211/81.763/4 Female NPT3/4 Female NPT7 5/8"6 1/2"6"21/2"67705K120000000
    31221353211/81.761 Female NPT1 Female NPT7 5/8"6 1/2"6"21/2"67705K8000000
    31221353211/81.761 1/4 Female NPT1 1/4 Female NPT7 5/8"6 1/2"6"21/2"67705K11000000
    31221353211/81.761 1/2 Female NPT1 1/2 Female NPT7 5/8"6 1/2"6"21/2"67705K9000000
    34261753411/623/4 Female NPT3/4 Female NPT7 3/4"6 1/2"6"21/2"67705K17000000
    34261753411/621 Female NPT1 Female NPT7 3/4"6 1/2"6"21/2"67705K13000000
    34261753411/621 1/4 Female NPT1 1/4 Female NPT7 3/4"6 1/2"6"21/2"67705K16000000
    34261753411/621 1/2 Female NPT1 1/2 Female NPT7 3/4"6 1/2"6"21/2"67705K14000000
     
    240V AC, Single Phase—Without Thermal Overload Protection
     
    Hardwire
    34261753411/61.063/4 Female NPT3/4 Female NPT7 1/2"6 1/2"6"21/2"67705K32000000
    34261753411/61.061 Female NPT1 Female NPT7 1/2"6 1/2"6"21/2"67705K25000000
    34261753411/61.061 1/4 Female NPT1 1/4 Female NPT7 1/2"6 1/2"6"21/2"67705K28000000
    34261753411/61.061 1/2 Female NPT1 1/2 Female NPT7 1/2"6 1/2"6"21/2"67705K26000000
     

    Self-Priming Circulation Pumps without Motor for Water

    Image of Product. Front orientation. Centrifugal Pumps. Self-Priming Circulation Pumps without Motor for Water.
    Also known as flexible impeller pumps, these create a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. The impeller resists clogging and wear. Select a spark-free air motor for hazardous environments or attach an electric motor with a speed reducer or a belt pulley to alter the pump speed.
    Repair kits (sold separately) include components such as impellers, O-rings, and seal lips.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Overall
    Shaft
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max.
    Viscosity
    Temp. Range,
    ° F
    Req. Power,
    hp
    Intake Connection
    Type
    Discharge Connection
    Type
    Ht.
    Lg.
    Wd.
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Each
    For 500 rpm to 2,100 rpm Motor Speed
    136026Not Rated50 to 1801/31/2 Female NPT1/2 Female NPT3 13/16"4 1/2"4 1/8"5/8"1 1/8"1 15/16"4281K210000000
    27.96026Not Rated50 to 1803/41 Female NPT1 Female NPT3 9/16"6 3/8"4 3/4"5/8"2 1/4"1 7/8"4281K23000000
     
    Repair Kits

    Easy-Maintenance Inline Circulation Pumps for Water

    Image of Product. Front orientation. Centrifugal Pumps. Easy-Maintenance Inline Circulation Pumps for Water.
    A detachable motor assembly allows you to leave these pumps inline while servicing or repairing the motor. The motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Install these pumps directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. Mount horizontally or vertically with the included pipe connectors. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Temp.
    Overall
    Max. Flow
    Rate, gpm
    Flow Rate @ 10 ft.
    of Head, gpm
    Max. ft. of
    Head, ft.
    Min.
    Max.,
    ° F
    Power, hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    338Not Rated225Fractional1.75 amp3/4 Female NPT3/4 Female NPT14 7/8"5"6 3/8"6769K260000000
    338Not Rated225Fractional1.75 amp1 Female NPT1 Female NPT14 7/8"5"6 3/8"6769K23000000
    338Not Rated225Fractional1.75 amp1 1/4 Female NPT1 1/4 Female NPT14 7/8"5"6 3/8"6769K25000000
    338Not Rated225Fractional1.75 amp1 1/2 Female NPT1 1/2 Female NPT14 7/8"5"6 3/8"6769K24000000
    752210Not Rated2251/61.9 amp1 Female NPT1 Female NPT15 3/8"5 1/4"8 1/2"6769K2700000000
    752210Not Rated2251/61.9 amp1 1/4 Female NPT1 1/4 Female NPT15 3/8"5 1/4"8 1/2"6769K2800000000
    752210Not Rated2251/61.9 amp1 1/2 Female NPT1 1/2 Female NPT15 3/8"5 1/4"8 1/2"6769K2900000000
     

    Heavy Duty Immersion Circulation Pumps for Water and Coolants

    Image of Product. Front orientation. Centrifugal Pumps. Heavy Duty Immersion Circulation Pumps for Water and Coolants.
    The durable motor and impeller can handle dirty coolant and machine lubricants with solids up to ¼" diameter. These pumps have an intake that can be completely submerged in liquid. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Flow
    Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max.
    Pressure
    Min.
    Max.
    Power,
    hp
    Current
    Intake Inlet
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Shaft
    Ht.
    Each
    208V AC to 240V AC/460V AC, Three Phase—Without Thermal Overload Protection
     
    Hardwire—108 cP Maximum Viscosity
    674032Not Rated402003/43 amp/2 ampOpen1 1/2 Female NPT10 3/4"9 1/4"19 3/4"9 7/8"9970K370000000
    674032Not Rated402003/43 amp/2 ampOpen1 1/2 Female NPT10 3/4"9 1/4"25 3/4"15 7/8"9970K39000000
    673417Not Rated402001/32 amp/1 ampOpen1 1/4 Female NPT8 3/4"8 3/8"20 5/8"11 3/4"9970K33000000
    674021Not Rated402001/32 amp/1 ampOpen1 1/4 Female NPT8 3/4"8 3/8"18 7/8"9 3/4"9970K35000000
     

    High-Flow Extended-Life Inline Circulation Pumps for Water

    Image of Product. Front orientation. Centrifugal Pumps. High-Flow Extended-Life Inline Circulation Pumps for Water.
    These pumps have higher flow rate than other inline circulation pumps and are cooled by the liquid being pumped to extend the life of the motor. Install them directly in your pipeline for applications such as hot-water circulation and solar heating. Pumps have an open dripproof (ODP) motor for use in clean, dry, and well-ventilated environments. Mount horizontally with required pipe connectors (sold separately). Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Required Pipe Connectors—When ordering the required pipe connectors (sold separately), please specify pipe size of ¾, 1, 1 ¼, or 1 ½.
    Pumps
    Required Pipe
    Connectors
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    Flow Rate @ 10 ft.
    of Head, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Pair
    120V AC, Single Phase—Without Thermal Overload Protection
     
    Hardwire—1 cP Maximum Viscosity
    22815150402301/250.8 ampFemale NPTFemale NPT5 5/8"4 7/8"6 3/8"8174K8100000008174K8000000
     

    Self-Priming Circulation Pumps without Motor for Oil

    Image of Product. Front orientation. Centrifugal Pumps. Self-Priming Circulation Pumps without Motor for Oil.
    Use these pumps to move lubricating oil such as hydraulic and motor oil. Also known as flexible impeller pumps, they create a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. The impeller resists clogging and wear. Select a spark-free air motor for hazardous environments or attach an electric motor with a speed reducer or a belt pulley to alter the pump speed.
    Repair kits (sold separately) include components such as impellers, O-rings, and seal lips.
    Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
    Shaft
    Overall
    Max. Flow
    Rate, gpm
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max.
    Viscosity
    Temp. Range,
    ° F
    Req. Power,
    hp
    Intake Connection
    Type
    Discharge Connection
    Type
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Ht.
    Lg.
    Wd.
    Each
    For 500 rpm to 2,100 rpm Motor Speed
    11.55021Not Rated50 to 1801/31/2 Female NPT1/2 Female NPT5/8"1 1/8"1 15/16"3 13/16"4 1/2"4 1/8"4281K240000000
    255026Not Rated50 to 1803/41 Female NPT1 Female NPT5/8"2 1/4"1 7/8"3 9/16"6 3/8"4 3/4"4281K26000000
     
    Repair Kits
    back to top