McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    497 Products
    About Directional Control Valves
    industrial info icon

    Choose the right valve for your application by matching the actions you'll power to our flow diagrams.

    Single-Action Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style A.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style B.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style C.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style D.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style E.

    Style A

    Style B

    Style C

    Style D

    Style E

    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style F.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style G.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style H.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style J.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style K.

    Style F

    Style G

    Style H

    Style J

    Style K

    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style L.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style M.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style N.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style P.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style Q.

    Style L

    Style M

    Style N

    Style P

    Style Q

    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style R.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style S.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style T.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style U.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style V.

    Style R

    Style S

    Style T

    Style U

    Style V

    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style W.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style X.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style Y.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style Z.

    Style W

    Style X

    Style Y

    Style

    Z

    Manually control these valves by pushing or turning the actuator. Also known as 3-way or 3/2 valves, they create one action, such as extending a cylinder. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. In the off position, they exhaust air pressure from the system, allowing equipment to reset so the action can be repeated. Valves without an exhaust connection exhaust air to the atmosphere.
    Threaded Female Inlet x Threaded Female Outlet
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style A.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style B.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style C.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style D.

    Style A

    Style B

    Style C

    Style D

    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style E.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style H.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style J.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style L.

    Style E

    Style H

    Style J

    Style L

    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style M.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style N.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style P.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style Q.

    Style M

    Style N

    Style P

    Style Q

    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style R.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style S.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style T.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style V.

    Style R

    Style S

    Style T

    Style V

    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style W.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style X.

    Style W

    Style X

    Spring Return—Valves with spring return actuation return to their original position as soon as you release the actuator.
    Hand Return—Valves with hand return actuation stay actuated and return to their original position only when you move the actuator again.
    Valve Position—Fail-closed valves block airflow until actuated. Valves that are both fail closed and fail open can be installed to block airflow, or allow air to flow until actuated.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    For Panel
    Cutout
    Style
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Vacuum
    Rating
    Actuator
    Color
    Lg.
    Wd.
    Ht.
    Dia.
    Wd.
    Lg.
    Mounting Fasteners
    Included
    Each
    Fail Closed
     
    Spring Return
    B31/8 NPT1/8 NPTThreaded50.150 to 120Not RatedBlack6"3/4"2 1/4"3/4"2"No61345K110000000
    C31/4 NPT1/4 NPTThreaded531.60 to 15029 in. Hg2 1/4"1 9/32"6 7/16"1 3/8"2 1/4"No6859K33000000
    D310-32 UNF10-32 UNFThreaded16.20.250 to 12526 in. Hg5/8"5/8"2 1/8"1/2"Yes8399K1200000
    J31/8 NPT1/8 NPT17.80.290 to 125Not RatedBlack1 1/4"5/8"2 1/2"1/2"Yes62475K2700000
    M31/8 NPT1/8 NPTThreaded60.110 to 12023 in. HgBlack1 3/4"3/4"2 3/8"1/2"3/4"1 3/4"Yes6464K1800000
    N31/8 NPT1/8 NPTThreaded60.110 to 12023 in. HgRed2 3/8"2 3/8"3 5/16"1 1/4"3/4"1 3/4"Yes6464K25000000
    P31/8 NPT1/8 NPTThreaded60.1060 to 100Not RatedBlack2 1/4"2 1/4"2 1/2"2 1/4"No6464K3500000
    P31/8 NPT1/8 NPTThreaded60.1060 to 100Not RatedGreen2 1/4"2 1/4"2 1/2"2 1/4"No6464K3400000
    P31/8 NPT1/8 NPTThreaded60.1060 to 100Not RatedRed2 1/4"2 1/4"2 1/2"2 1/4"No6464K3300000
    R31/4 NPT1/4 NPTThreaded0.980 to 14526.5 in. HgBlack1 1/8"1 7/8"4 7/8"7/8"No2700K13000000
    R31/4 NPT1/4 NPTThreaded531.60 to 15029 in. HgBlack2 3/16"1 1/4"6"7/8"Yes6859K31000000
    S310-32 UNF10-32 UNFThreaded16.20.250 to 12526 in. Hg5/8"5/8"1 7/8"1/2"Yes8399K1100000
    T310-32 UNF10-32 UNF14.40.240 to 125Not RatedBlack5/8"5/8"1 7/8"1/2"Yes62475K1200000
    V31/8 NPT1/8 NPT17.80.290 to 125Not RatedBlack1 1/4"5/8"2 1/8"1/2"Yes62475K2200000
    W31/8 NPT1/8 NPTThreaded60.110 to 12023 in. HgBlack1 7/8"1 5/8"2 1/2"1 1/4"3/4"1 3/4"Yes6464K19000000
     
    Hand Return
    A31/8 NPT1/8 NPT7.90.140 to 150Not RatedBlack1 5/8"No6650K7000000
    D310-32 UNF10-32 UNFThreaded16.20.250 to 12526 in. Hg5/8"5/8"2 1/8"1/2"Yes8399K1300000
    E31/8 NPT1/8 NPTThreaded250.4420 to 300Not Rated7/8"5/8"3"1/2"Yes62475K4100000
    H310-32 UNF10-32 UNF14.40.240 to 125Not RatedBlack5/8"5/8"2 1/4"1/2"Yes62475K1600000
    J31/8 NPT1/8 NPT17.80.290 to 125Not RatedBlack1 1/4"5/8"2 1/2"1/2"Yes62475K2600000
    Q31/8 NPT1/8 NPTThreaded10.70.340 to 14526.5 in. HgRed4 1/2"7/8"1 3/8"1 1/4"No61345K16000000
    R31/4 NPT1/4 NPTThreaded0.980 to 14526.5 in. HgBlack1 1/8"1 7/8"5 1/4"7/8"No2700K14000000
    R31/4 NPT1/4 NPTThreaded531.60 to 15029 in. HgBlack2 1/4"1 3/8"6 3/16"7/8"Yes6859K32000000
     
    Fail Open/Fail Closed
     
    Hand Return
    C31/4 NPT1/4 NPTThreaded531.60 to 15029 in. Hg2 1/8"1 1/4"6 3/8"1 1/4"2 1/8"No6859K34000000
    L31/8 NPT1/8 NPTThreaded60.110 to 12023 in. Hg1 3/4"3/4"2 1/2"1/2"3/4"1 3/4"Yes6464K1600000
    X31/8 NPT1/8 NPTThreaded60.110 to 12023 in. HgBlack1 7/8"1 5/8"3"1 1/4"3/4"1 3/4"Yes6464K17000000
     
    Threaded Male Inlet x Threaded Female Outlet
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style H.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style J.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style T.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style V.

    Style H

    Style J

    Style T

    Style V

    Spring Return—Valves with spring return actuation return to their original position as soon as you release the actuator.
    Hand Return—Valves with hand return actuation stay actuated and return to their original position only when you move the actuator again.
    Valve Position—Fail-closed valves block airflow until actuated. Valves that are both fail closed and fail open can be installed to block airflow, or allow air to flow until actuated.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    Style
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Vacuum
    Rating
    Actuator
    Color
    Lg.
    Wd.
    Ht.
    For Panel
    Cutout Dia.
    Mounting Fasteners
    Included
    Each
    Fail Closed
     
    Spring Return
    H31/8 NPT10-32 UNF14.40.240 to 125Not RatedBlack5/8"5/8"2 1/4"1/2"Yes62475K15000000
    T31/8 NPT10-32 UNF14.40.240 to 125Not RatedBlack5/8"5/8"1 7/8"1/2"Yes62475K1100000
    V31/8 NPT1/8 NPT17.80.290 to 125Not RatedBlack1 1/4"5/8"2 1/8"1/2"Yes62475K2100000
     
    Hand Return
    H31/8 NPT10-32 UNF14.40.240 to 125Not RatedBlack5/8"5/8"2 1/4"1/2"Yes62475K1400000
    J31/8 NPT1/8 NPT17.80.290 to 125Not RatedBlack1 1/4"5/8"2 3/8"1/2"Yes62475K2400000
     
    Push-to-Connect Female Inlet x Threaded Male Outlet
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style K.

    Style K

    Hand Return—Valves with hand return actuation stay actuated and return to their original position only when you move the actuator again.
    Valve Position—Fail-closed valves block airflow until actuated. Valves that are both fail closed and fail open can be installed to block airflow, or allow air to flow until actuated.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    Style
    No. of Flow
    Ports
    For Inlet
    Tube OD
    Outlet
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    For Panel
    Cutout Dia.
    Mounting Fasteners
    Included
    Each
    Fail Open/Fail Closed
     
    Hand Return
    K35/32"1/8 NPT2.630.0060 to 145Not Rated1 1/8"5/8"2 1/8"1/2"No62475K31000000
    K31/4"1/8 NPT6.720.0480 to 145Not Rated1 1/8"5/8"2 1/8"1/2"No62475K3200000
    K31/4"1/4 NPT9.120.1150 to 145Not Rated1 1/4"3/4"2 1/2"1/2"No62475K3300000
    K33/8"1/4 NPT10.90.1390 to 145Not Rated1 1/2"3/4"2 1/2"1/2"No62475K3400000
     
    Push-to-Connect Female Inlet x Push-to-Connect Female Outlet
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style J.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style V.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style Y.

    Style J

    Style V

    Style Y

    Spring Return—Valves with spring return actuation return to their original position as soon as you release the actuator.
    Hand Return—Valves with hand return actuation stay actuated and return to their original position only when you move the actuator again.
    Valve Position—Fail-closed valves block airflow until actuated. Valves that are both fail closed and fail open can be installed to block airflow, or allow air to flow until actuated.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    Style
    No. of Flow
    Ports
    For Inlet
    Tube OD
    For Outlet
    Tube OD
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Vacuum
    Rating
    Actuator
    Color
    Lg.
    Wd.
    Ht.
    For Panel
    Cutout Dia.
    Mounting Fasteners
    Included
    Each
    Fail Closed
     
    Spring Return
    J31/4"1/4"17.80.290 to 125Not RatedBlack1 1/4"5/8"2 5/8"1/2"Yes62475K29000000
    V31/4"1/4"17.80.290 to 125Not RatedBlack1 1/4"5/8"2 1/4"1/2"Yes62475K2300000
     
    Hand Return
    J31/4"1/4"17.80.290 to 125Not RatedBlack1 1/4"5/8"2 5/8"1/2"Yes62475K2800000
    Y34 mm4 mm5.750.180 to 145Not RatedBlue47.6 mm19 mm41.3 mm3/4"Yes5360T1200000
    Y36 mm6 mm12.770.390 to 145Not RatedBlue47.6 mm19 mm41.3 mm3/4"Yes5360T1400000
    Y38 mm8 mm16.920.530 to 145Not RatedBlue54 mm19 mm41.3 mm3/4"Yes5360T1600000
    Y310 mm10 mm28.420.890 to 145Not RatedBlue60.3 mm22.2 mm47.6 mm3/4"Yes5360T2100000
     
    Barbed Male Inlet x Threaded Female Outlet
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style Z.

    Style

    Z

    Spring Return—Valves with spring return actuation return to their original position as soon as you release the actuator.
    Valve Position—Fail-closed valves block airflow until actuated. Valves that are both fail closed and fail open can be installed to block airflow, or allow air to flow until actuated.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    Style
    No. of Flow
    Ports
    For Inlet
    Tube ID
    Outlet
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Vacuum
    Rating
    Actuator
    Color
    Lg.
    Wd.
    Ht.
    For Panel
    Cutout Dia.
    Mounting Fasteners
    Included
    Each
    Fail Closed
     
    Spring Return
    Z30.17"10-32 UNF14.40.240 to 125Not RatedBlack5/8"5/8"2"1/2"Yes62475K13000000
     
    Barbed Male Inlet x Barbed Male Outlet
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style F.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style G.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air Directional Control Valves, Style U.

    Style F

    Style G

    Style U

    Spring Return—Valves with spring return actuation return to their original position as soon as you release the actuator.
    Hand Return—Valves with hand return actuation stay actuated and return to their original position only when you move the actuator again.
    Valve Position—Fail-closed valves block airflow until actuated. Valves that are both fail closed and fail open can be installed to block airflow, or allow air to flow until actuated.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    Style
    No. of Flow
    Ports
    For Inlet
    Tube ID
    For Outlet
    Tube ID
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Vacuum
    Rating
    Actuator Color
    Lg.
    Wd.
    Ht.
    For Panel
    Cutout Dia.
    Mounting Fasteners
    Included
    Each
    Fail Closed
     
    Hand Return
    F31/16"1/16"1.40.0250 to 100Not Rated3/8"3/8"1 1/2"1/4"Yes62475K42000000
    G31/16"1/16"Barbed
    2.20.040 to 12520 in. Hg5/8"3/8"1 5/8"3/8"Yes62475K3500000
     
    Fail Open/Fail Closed
     
    Spring Return
    U31/16"1/16"Barbed
    1.40.0250 to 100Not RatedBlack, Green, Red, White3/8"3/8"1 1/4"1/4"Yes62475K5900000
     

    Two-Speed Two-Action Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style A.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style B.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style C.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style D.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style E.

    Style A

    Style B

    Style C

    Style D

    Style E

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style F.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style G.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style H.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style J.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style K.

    Style F

    Style G

    Style

    H

    Style J

    Style K

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style L.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style M.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style N.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style P.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style Q.

    Style L

    Style M

    Style

    N

    Style P

    Style Q

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style R.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style S.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves, Style T.

    Style R

    Style S

    Style T

    Often used to extend and then retract a cylinder at different speeds, these valves create two actions and have two exhaust ports. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Also known as 4-way and 5/2 valves.
    Spring Return—Valves with spring return actuation return to their original position as soon as you release the actuator.
    Hand Return—Valves with hand return actuation stay actuated and return to their original position only when you move the actuator again.
    Exhaust Connection—Valves with threaded exhaust connection type allow you to control the speed of each action by attaching a flow control valve to each exhaust port. Valves with no exhaust connection type exhaust air to the atmosphere.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    For Panel
    Cutout
    Style
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount Type
    Dia.
    Wd.
    Lg.
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Spring Return
    A51/8 NPT1/8 NPTThreaded17.50.50 to 145Not Rated3 3/4"1 5/8"3 3/4"Panel, Screw In3/4"No0.22"3368K140000000
    A51/4 NPT1/4 NPTThreaded45.51.30 to 145Not Rated4 3/4"2 1/16"4 3/4"Panel, Screw In1"No0.26"3368K44000000
    A53/8 NPT3/8 NPTThreaded65.341.714 to 14528 in. Hg1"2"3 7/8"Screw InNo0.17"6859K71000000
    B51/4 NPT1/4 NPTThreaded450.750 to 120Not Rated5 3/8"2"5 5/8"Screw InNo0.22"4493K24000000
    D51/8 NPT1/8 NPTThreaded140.2425 to 125Not Rated2 5/8"3/4"2 5/8"Panel, Screw In1 1/2"1.25"No0.19"61345K52000000
    E51/4 NPT1/4 NPTThreaded531.60 to 15029 in. Hg2 3/16"1 1/4"7 1/2"Panel, Screw In1 3/8"2.25"No0.26"6859K53000000
    H510-32 UNF10-32 UNFThreaded15.30.230 to 125Not Rated3/4"11/16"2 7/8"Panel1/2"Yes62475K5200000
    K51/4 NPT1/4 NPTThreaded32.50.980 to 14526.5 in. Hg1 1/8"1 7/8"5 3/4"Panel, Screw In7/8"No0.26"2700K11000000
    K51/4 NPT1/4 NPTThreaded531.60 to 15029 in. Hg2 1/4"1 3/8"7"Panel, Screw In7/8"Yes0.26"6859K51000000
    L51/8 NPT1/8 NPTThreaded140.2425 to 125Not Rated1 3/8"1 3/8"3 5/8"Panel, Screw In1/2"No0.19"61345K76000000
    N51/8 NPT1/8 NPTThreaded3510 to 120Not Rated3 1/2"1 7/8"2 7/8"Screw InNo0.21"4558K16000000
    N51/4 NPT1/4 NPTThreaded3510 to 120Not Rated3 1/2"1 7/8"2 7/8"Screw InNo0.21"4558K15000000
    N510-32 UNF10-32 UNFThreaded15.30.230 to 125Not Rated3/4"11/16"2 5/8"Panel1/2"Yes62475K5100000
    N510-32 UNF10-32 UNFThreaded160.230 to 125Not Rated3/4"11/16"2 5/8"Panel1/2"Yes62475K3600000
    P51/8 NPT1/8 NPTThreaded160.370 to 125Not Rated1 1/4"5/8"2 5/8"Panel, Screw In1/2"Yes0.14"62475K3800000
    Q51/8 NPT1/8 NPTThreaded140.2425 to 125Not Rated1 5/8"1 5/8"3/4"Panel, Screw In1 1/4"No0.19"61345K77000000
    R51/8 NPT1/8 NPTThreaded10.50.1860 to 15028 in. Hg1 1/4"5/8"2 5/8"Panel1/2"Yes62475K5700000
     
    Hand Return
    A51/8 NPT1/8 NPTThreaded17.50.50 to 145Not Rated3 3/4"1 5/8"3 3/4"Panel, Screw In3/4"No0.22"3368K13000000
    A51/4 NPT1/4 NPTThreaded45.51.30 to 145Not Rated4 3/4"2 1/16"4 3/4"Panel, Screw In1"No0.26"3368K24000000
    A53/8 NPT3/8 NPTThreaded65.341.714 to 14528 in. Hg1"2"3 7/8"Screw InNo0.17"6859K72000000
    B51/4 NPT1/4 NPTThreaded450.750 to 120Not Rated5 3/8"2"5 5/8"Screw InNo0.22"4493K34000000
    C51/8 NPT1/8 NPTThreaded140.2425 to 125Not Rated1 1/4"3/4"3 1/2"Panel, Screw In1/2"No0.19"61345K53000000
    E51/4 NPT1/4 NPTThreaded531.60 to 15029 in. Hg2 1/8"1 1/4"7 7/16"Panel, Screw In1 1/4"2.125"No0.26"6859K54000000
    F51/8 NPT1/8 NPT10.50.1860 to 15028 in. Hg1 1/4"5/8"2 3/4"Panel1/2"Yes62475K4400000
    F510-32 UNF10-32 UNF100.1770 to 15028 in. Hg7/8"5/8"2 3/4"Panel1/2"Yes62475K4300000
    G51/8 NPT1/8 NPTThreaded140.2425 to 125Not Rated1 1/4"3/4"3 3/4"Panel, Screw In1/2"No0.19"61345K73000000
    H510-32 UNF10-32 UNFThreaded15.30.230 to 125Not Rated3/4"11/16"2 7/8"Panel1/2"Yes62475K5300000
    J51/8 NPT1/8 NPTThreaded160.370 to 125Not Rated1 1/4"5/8"2 7/8"Panel, Screw In1/2"Yes0.14"62475K3900000
    K51/4 NPT1/4 NPTThreaded32.50.980 to 14526.5 in. Hg1 1/8"1 7/8"6 1/8"Panel, Screw In7/8"No0.26"2700K12000000
    K51/4 NPT1/4 NPTThreaded531.60 to 15029 in. Hg2 3/16"1 1/4"7 9/32"Panel, Screw In7/8"Yes0.26"6859K52000000
    L51/8 NPT1/8 NPTThreaded250.80 to 120Not Rated7/8"1 3/8"3 7/8"Panel, Screw In5/8"No0.13"61345K1300000
    M51/8 NPT1/8 NPTThreaded190.3415 to 150Not Rated1 1/2"1 1/2"4 1/2"Panel1 1/4"61345K55000000
    S51/4 NPT1/4 NPTThreaded56140 to 120Not Rated3"1 7/8"2"Screw InNo0.21"4558K17000000
    T51/8 NPT1/8 NPTThreaded140.2425 to 125Not Rated1 5/8"1 5/8"4 3/8"Panel, Screw In1 1/4"No0.19"61345K75000000
     

    Two-Speed Two-Action Electrically Operated Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style A.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style B.

    Style A

    Style B

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style C.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style D.

    Style C

    Style D

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style E.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style F.

    Style E

    Style F

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style G.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style H.

    Style G

    Style H

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style J.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style K.

    Style J

    Style K

    Often used to extend and then retract a cylinder at different speeds, these valves create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Also known as 4-way and 5/2 valves, they actuate when voltage is applied to the electrical connection. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion.
    Threaded Female Inlet × Threaded Female Outlet—Threaded Exhaust
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style A.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style B.

    Style A

    Style B

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style C.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style D.

    Style C

    Style D

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style E.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style F.

    Style E

    Style F

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style G.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style H.

    Style G

    Style H

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style J.

    Style J

    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    NPTF Inlet Thread—NPTF (Dryseal) threads are compatible with NPT threads.
    Manifold Mount—Manifold-mount valves plug into a manifold (sold separately) to create multiple actions from a single pressure input. Manifolds with multiple exhaust ports have one set of inlet and exhaust ports on each side, so they can be strung together in a series. When using a single manifold, cover the ports on the side you are not using with plugs (sold separately).
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Valves
    Replacement
    Solenoid Valve Plugs
    Replacement
    Solenoids
    Overall
    Style
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount Type
    For Manifold
    Style
    Choose a Voltage
    Each
    Each
    Each
    Single Solenoid—Spring Return
    A51/8 NPT1/8 NPT43.10.7544 to 145Not Rated5 1/8"7/8"2 1/2"Manifold, Screw In112V DC6124K27400000006124K301000006124K335000000
    A51/8 NPT1/8 NPT43.10.7544 to 145Not Rated5 1/8"7/8"2 1/2"Manifold, Screw In124V DC6124K2750000006124K30100006124K33400000
    A51/8 NPT1/8 NPT43.10.7544 to 145Not Rated5 1/8"7/8"2 1/2"Manifold, Screw In1120V AC6124K2760000006124K30100006124K33300000
    A51/8 NPTF1/8 NPTF56115 to 15028 in. Hg5 1/2"7/8"2 3/4"Manifold, Screw In224V DC, 120V AC6425K11000000———0———0
    A51/4 NPT1/4 NPT43.11.344 to 145Not Rated6"1"2 5/8"Manifold, Screw In312V DC6124K2770000006124K30100006124K33500000
    A51/4 NPT1/4 NPT43.11.344 to 145Not Rated6"1"2 5/8"Manifold, Screw In324V DC6124K2780000006124K30100006124K33400000
    A51/4 NPT1/4 NPT43.11.344 to 145Not Rated6"1"2 5/8"Manifold, Screw In3120V AC6124K2790000006124K30100006124K33300000
    A51/4 NPTF1/4 NPTF56115 to 15028 in. Hg5 1/2"7/8"2 3/4"Manifold, Screw In224V DC, 120V AC6425K13000000———0———0
    A51/4 NPTF1/4 NPTF95.21.715 to 15028 in. Hg6"1"3"Manifold, Screw In424V DC, 120V AC6425K21000000———0———0
    A53/8 NPTF3/8 NPTF53.11.635 to 150Not Rated7 1/2"1 1/4"5 1/4"Screw In12V DC, 24V DC, 120V AC6124K55000000———0———0
    A53/8 NPTF3/8 NPTF95.21.715 to 15028 in. Hg6"1"3"Manifold, Screw In424V DC, 120V AC6425K23000000———0———0
    A510-32 UNF10-32 UNF8.20.2644 to 150Not Rated3 7/8"5/8"1 7/8"Screw In12V DC, 24V DC, 120V AC6124K23000000———0———0
    B51/2 NPTF1/2 NPTF165.9520 to 150Not Rated9 1/2"1 1/2"2 3/4"Screw In12V DC6124K1610000006124K3010000———0
    B51/2 NPTF1/2 NPTF165.9520 to 150Not Rated9 1/2"1 1/2"2 3/4"Screw In24V DC6124K1620000006124K30100006124K33400000
    B51/2 NPTF1/2 NPTF165.9520 to 150Not Rated9 1/2"1 1/2"2 3/4"Screw In120V AC6124K160000006124K30100006124K33300000
    C51/4 NPT1/4 NPT56140 to 120Not Rated4 3/8"1 7/8"3 3/8"Screw In12V DC6196K232000000———0———0
    C51/4 NPT1/4 NPT56140 to 120Not Rated4 3/8"1 7/8"3 3/8"Screw In24V DC6196K233000000———06196K200000
    C51/4 NPT1/4 NPT56140 to 120Not Rated4 3/8"1 7/8"3 3/8"Screw In120V AC6196K27000000———06196K300000
    C51/4 NPT1/4 NPT56140 to 120Not Rated4 3/8"1 7/8"3 3/8"Screw In240V AC6196K231000000———06196K100000
    D51/4 NPT1/4 NPT8.40.820 to 150Not Rated4 3/8"1 1/2"3 11/16"Screw In120V AC4368T44000000———0———0
    D51/4 NPT1/4 NPT8.40.820 to 150Not Rated4 7/16"1 1/2"3 11/16"Screw In24V DC4368T48000000———0———0
    E53/4 NPTF3/4 NPTF287915 to 145Not Rated10"4 1/4"6 1/2"Screw In24V DC4701T74000000———0———0
    E53/4 NPTF3/4 NPTF287915 to 145Not Rated10"4 1/4"6 1/2"Screw In120V AC4701T73000000———04701T5100000
     
    Double Solenoid—Solenoid Return
    E53/4 NPTF3/4 NPTF287915 to 145Not Rated10 1/2"4 1/4"6 1/2"Screw In24V DC, 120V AC4701T8000000———0———0
    F51/8 NPT1/8 NPT43.10.7529 to 145Not Rated6 7/8"7/8"2 1/2"Manifold, Screw In112V DC, 24V DC, 120V AC6124K5150000006124K3010000———0
    F51/8 NPTF1/8 NPTF56115 to 15028 in. Hg8 1/4"7/8"2 3/4"Manifold, Screw In224V DC, 120V AC6425K12000000———0———0
    F51/4 NPT1/4 NPT43.11.329 to 145Not Rated7 7/8"1"2 5/8"Manifold, Screw In312V DC, 24V DC, 120V AC6124K5160000006124K3010000———0
    F51/4 NPTF1/4 NPTF56115 to 15028 in. Hg8 1/4"7/8"2 3/4"Manifold, Screw In224V DC, 120V AC6425K14000000———0———0
    F51/4 NPTF1/4 NPTF95.21.715 to 15028 in. Hg8 7/8"1"3"Manifold, Screw In424V DC, 120V AC6425K22000000———0———0
    F53/8 NPTF3/8 NPTF95.21.715 to 15028 in. Hg8 7/8"1"3"Manifold, Screw In424V DC, 120V AC6425K24000000———0———0
    G51/2 NPTF1/2 NPTF165.9520 to 150Not Rated12 3/8"1 1/2"2 3/4"Screw In24V DC, 120V AC6124K630000006124K3010000———0
    H53/8 NPTF3/8 NPTF53.11.635 to 150Not Rated9 1/4"1 1/4"5 1/4"Screw In24V DC, 120V AC6124K62000000———0———0
    J51/4 NPT1/4 NPT56140 to 120Not Rated5 7/8"1 7/8"3 3/8"Screw In12V DC, 24V DC, 120V AC, 240V AC6196K24000000———0———0
     
    Accessories for Valves
    Push-to-Connect Female Inlet × Push-to-Connect Female Outlet—Push-to-Connect Exhaust
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves, Style K.

    Style K

    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    Style
    No. of Flow
    Ports
    For Inlet
    Tube OD, mm
    For Outlet
    Tube OD, mm
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Voltage,
    V DC
    Each
    Single Solenoid—Spring Return
    K56617.50.3144 to 10129.523 1/8"7/16"2 1/8"Screw In244658A310000000
     
    Double Solenoid—Solenoid Return
    K56617.50.3129 to 10129.523 1/4"7/16"2 1/8"Screw In244658A32000000
     

    Single-Action Electrically Operated Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style A.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style B.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style C.

    Style A

    Style B

    Style C

    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style D.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style E.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style F.

    Style D

    Style E

    Style F

    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style G.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style H.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style J.

    Style G

    Style H

    Style J

    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style K.

    Style K

    These valves create one action, such as extending a cylinder. Apply voltage to the electrical connection to actuate. Also known as 3-way and 3/2 valves, they direct airflow from the inlet to your equipment and exhaust return airflow to create motion. In the off position, they exhaust air from the system, allowing equipment to reset so the action can be repeated. Valves without an exhaust connection exhaust air to the atmosphere.
    Threaded Female Inlet × Threaded Female Outlet: Fail-Closed Valve
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style A.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style B.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style C.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style E.

    Style A

    Style B

    Style C

    Style E

    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style G.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style H.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style J.

    Style G

    Style H

    Style J

    Fail-closed valves block airflow until actuated.
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    NPTF Inlet Thread—NPTF (Dryseal) threads are compatible with NPT threads.
    Manifold Mount—Manifold-mount valves plug into a manifold (sold separately) to create multiple actions from a single pressure input. Manifolds with multiple exhaust ports have one set of inlet and exhaust ports on each side, so they can be strung together in a series. When using a single manifold, cover the ports on the side you are not using with plugs (sold separately).
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Valves
    Replacement
    Solenoid Valve Plugs
    Replacement
    Solenoids
    Overall
    Style
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow
    Rate @ 100 psi
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Lg.
    Wd.
    Ht.
    Mount Type
    Choose a Voltage
    Each
    Each
    Each
    Single Solenoid—Spring Return
    A31/8 NPT1/8 NPTThreaded24.9 scfm0.7529 to 1454 5/8"7/8"1 3/8"Manifold, Screw In12V DC6124K27100000006124K30100000———0
    A31/8 NPT1/8 NPTThreaded24.9 scfm0.7529 to 1454 5/8"7/8"1 3/8"Manifold, Screw In24V DC6124K2720000006124K30100006124K334000000
    A31/8 NPT1/8 NPTThreaded24.9 scfm0.7529 to 1454 5/8"7/8"1 3/8"Manifold, Screw In120V AC6124K2730000006124K30100006124K33300000
    A31/4 NPT1/4 NPTThreaded24.9 scfm1.329 to 1455 1/2"1"1 5/8"Manifold, Screw In12V DC6124K2910000006124K30100006124K33500000
    A31/4 NPT1/4 NPTThreaded24.9 scfm1.329 to 1455 1/2"1"1 5/8"Manifold, Screw In24V DC6124K2920000006124K30100006124K33400000
    A31/4 NPT1/4 NPTThreaded24.9 scfm1.329 to 1455 1/2"1"1 5/8"Manifold, Screw In120V AC6124K2930000006124K30100006124K33300000
    A33/8 NPTF3/8 NPTFThreaded53.1 scfm1.735 to 1506 1/2"1 1/4"4 3/4"Screw In12V DC6124K1210000006124K3010000———0
    A33/8 NPTF3/8 NPTFThreaded53.1 scfm1.735 to 1506 1/2"1 1/4"4 3/4"Screw In24V DC6124K1220000006124K30100006124K33200000
    A33/8 NPTF3/8 NPTFThreaded53.1 scfm1.735 to 1506 1/2"1 1/4"4 3/4"Screw In120V AC6124K120000006124K30100006124K33100000
    B31/8 NPT1/8 NPTThreaded5.6 scfm0.1-14.7 to 14.53 1/4"1 5/8"3"Screw In24V DC61245K2100000———0———0
    B31/4 NPT1/4 NPTThreaded6 scfm0.11-14.7 to 14.53 1/4"1 5/8"3"Screw In24V DC61245K2200000———0———0
    B310-32 UNF1/8 NPTFThreaded4.1 scfm0.13-14 to 14.52 11/16"15/16"2 7/16"Screw In12V DC, 24V DC, 120V AC61975K2800000———0———0
    B310-32 UNF10-32 UNFThreaded4.1 scfm0.13-14 to 14.52 11/16"15/16"2 7/16"Screw In12V DC, 24V DC, 120V AC61975K2700000———0———0
    C31/4 NPT1/4 NPTThreaded2.3 scfm0.120 to 1153"7/8"2 3/8"Screw In12V DC61975K41300000———061975K5300000
    C31/4 NPT1/4 NPTThreaded2.3 scfm0.120 to 1153"7/8"2 3/8"Screw In24V DC61975K41200000———061975K5200000
    C31/4 NPT1/4 NPTThreaded2.3 scfm0.120 to 1153"7/8"2 3/8"Screw In24V AC61975K41100000———061975K5100000
    C31/4 NPT1/4 NPTThreaded2.3 scfm0.120 to 1153"7/8"2 3/8"Screw In120V AC61975K41400000———061975K5400000
    C31/4 NPT1/4 NPTThreaded2.3 scfm0.120 to 1153"7/8"2 3/8"Screw In220V AC61975K41500000———0———0
    C310-32 UNF10-32 UNFThreaded27 scfm0.5820 to 1253 3/8"3/4"2 1/8"Screw In12V DC6124K53100000———0———0
    C310-32 UNF10-32 UNFThreaded27 scfm0.5820 to 1253 3/8"3/4"2 1/8"Screw In24V DC6124K53200000———06124K19100000
    C310-32 UNF10-32 UNFThreaded27 scfm0.5820 to 1253 3/8"3/4"2 1/8"Screw In110V AC6124K53400000———06124K19200000
    G31/8 NPT1/8 NPT1.97 scfm0.0350 to 1201 7/8"1 1/4"2 3/8"Screw In12V DC61245K84000000———061245K500000
    G31/8 NPT1/8 NPT1.97 scfm0.0350 to 1201 7/8"1 1/4"2 3/8"Screw In24V DC61245K74000000———061245K400000
    G31/8 NPT1/8 NPT1.97 scfm0.0350 to 1201 7/8"1 1/4"2 3/8"Screw In120V AC61245K73000000———061245K300000
    G31/8 NPT1/8 NPT1.97 scfm0.0350 to 1201 7/8"1 1/4"2 3/8"Screw In240V AC61245K83000000———0———0
    G31/4 NPT1/4 NPTNot Rated0.0350 to 1201 3/4"1 1/4"2 3/4"Screw In24V DC61245K66000000———0———0
    G31/4 NPT1/4 NPTNot Rated0.0350 to 1201 3/4"1 1/4"2 3/4"Screw In120V AC61245K65000000———0———0
    H31/8 NPT1/8 NPTThreaded1.97 scfm0.0350 to 1201 7/8"1 1/4"2 3/4"Screw In12V DC61245K86000000———061245K500000
    H31/8 NPT1/8 NPTThreaded1.97 scfm0.0350 to 1201 7/8"1 1/4"2 3/4"Screw In24V DC61245K76000000———061245K400000
    H31/8 NPT1/8 NPTThreaded1.97 scfm0.0350 to 1201 7/8"1 1/4"2 3/4"Screw In120V AC61245K75000000———061245K300000
    H31/8 NPT1/8 NPTThreaded1.97 scfm0.0350 to 1201 7/8"1 1/4"2 3/4"Screw In240V AC61245K85000000———0———0
    J310-32 UNF10-32 UNF0.6 scfmNot Rated0 to 1057/8"1 1/4"1 5/8"Screw In6V DC, 12V DC, 24V DC4916K200000———0———0
     
    Double Solenoid—Solenoid Return
    E310-32 UNF10-32 UNFThreaded27 scfm0.5820 to 1255"3/4"2 1/8"Screw In24V DC, 110V AC6124K54100000———0———0
     
    Fully Insulated Quick-Disconnect Terminals for Style J Valves
    Threaded Female Inlet × Threaded Female Outlet: Fail-Open Valve/Fail-Closed Valve
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style D.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style F.

    Style D

    Style F

    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style H.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style J.

    Style H

    Style J

    Valves that are both fail closed and fail open can be installed to block airflow, or allow air to flow until actuated.
    Fail-closed valves block airflow until actuated.
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    NPTF Inlet Thread—NPTF (Dryseal) threads are compatible with NPT threads.
    Manifold Mount—Manifold-mount valves plug into a manifold (sold separately) to create multiple actions from a single pressure input. Manifolds with multiple exhaust ports have one set of inlet and exhaust ports on each side, so they can be strung together in a series. When using a single manifold, cover the ports on the side you are not using with plugs (sold separately).
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Valves
    Replacement
    Solenoid Valve Plugs
    Replacement
    Solenoids
    Overall
    Style
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow
    Rate @ 100 psi
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Lg.
    Wd.
    Ht.
    Mount Type
    Choose a Voltage
    Each
    Each
    Each
    Single Solenoid—Spring Return
    H31/8 NPT1/8 NPTThreadedNot Rated0.0350 to 1201 3/4"1 1/4"2 7/8"Screw In24V DC61245K620000000———061245K4000000
    H31/8 NPT1/8 NPTThreadedNot Rated0.0350 to 1201 3/4"1 1/4"2 7/8"Screw In120V AC61245K61000000———061245K300000
    H31/4 NPT1/4 NPTThreadedNot Rated0.0350 to 1201 3/4"1 1/4"2 7/8"Screw In24V DC61245K64000000———0———0
    H31/4 NPT1/4 NPTThreadedNot Rated0.0350 to 1201 3/4"1 1/4"2 7/8"Screw In120V AC61245K63000000———0———0
    J310-32 UNF10-32 UNFThreaded0.6 scfmNot Rated0 to 1057/8"1 1/4"1 7/8"Screw In6V DC, 12V DC, 24V DC4916K700000———0———0
     
    Double Solenoid—Solenoid Return
    D31/8 NPT1/8 NPTThreaded24.9 scfm0.7529 to 1456 1/4"7/8"1 3/8"Manifold, Screw In24V DC, 120V AC6124K5140000006124K30100000———0
    D31/4 NPT1/4 NPTThreaded24.9 scfm1.329 to 1457 1/16"1"1 5/8"Manifold, Screw In24V DC, 120V AC6124K5180000006124K3010000———0
    F33/8 NPTF3/8 NPTFThreaded53.1 scfm1.735 to 1508 1/4"1 1/4"4 3/4"Screw In24V DC, 120V AC6124K580000006124K3010000———0
     
    Fully Insulated Quick-Disconnect Terminals for Style J Valves
    Push to Connect Female Inlet × Push to Connect Female Outlet: Fail-Closed Valve
    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves, Style K.

    Style K

    Fail-closed valves block airflow until actuated.
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Manifold Mount—Manifold-mount valves plug into a manifold (sold separately) to create multiple actions from a single pressure input. Manifolds with multiple exhaust ports have one set of inlet and exhaust ports on each side, so they can be strung together in a series. When using a single manifold, cover the ports on the side you are not using with plugs (sold separately).
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    Style
    No. of Flow
    Ports
    For Inlet
    Tube OD
    For Outlet
    Tube OD
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Lg.
    Wd.
    Ht.
    Mount Type
    Choose a Voltage
    Each
    Single Solenoid—Spring Return
    K35/32"5/32"Push to Connect0.60.010 to 1201 3/8"5/8"1 3/4"Manifold, Screw In12V DC, 24V DC, 120V AC62095K2000000
    K35/32"5/32"Push to Connect1.10.020 to 1201 3/8"5/8"1 3/4"Manifold, Screw In12V DC, 24V DC, 120V AC62095K100000
     
    Accessories for Valves

    Two-Action Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Two-Action Air Directional Control Valves , Style A.
    Image of Product. Front orientation. Directional Control Valves. Two-Action Air Directional Control Valves , Style B.

    Style A

    Style B

    Image of Product. Front orientation. Directional Control Valves. Two-Action Air Directional Control Valves , Style C.
    Image of Product. Front orientation. Directional Control Valves. Two-Action Air Directional Control Valves , Style D.

    Style C

    Style D

    Also known as 4-way and 4/2 valves, these valves create two actions, such as extending and then retracting a double-acting cylinder. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Valves without an exhaust connection exhaust air to the atmosphere.
    Spring Return—Valves with spring return actuation return to their original position as soon as you release the actuator.
    Hand Return—Valves with hand return actuation stay actuated and return to their original position only when you move the actuator again.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    For Panel
    Cutout
    Style
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount Type
    Dia.
    Wd.
    Lg.
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Spring Return
    A51/8 NPT1/8 NPT50.150 to 120Not Rated5 7/8"1 1/2"2 3/4"Panel, Screw In3/4"2"No0.19"61345K120000000
    B510-32 UNF10-32 UNF100.170 to 15028 in. Hg7/8"5/8"2 1/2"Panel1/2"Yes61345K8100000
     
    Hand Return
    C41/8 NPT1/8 NPT7.90.140 to 150Not Rated1 5/8"Screw InNo0.2"6650K8000000
    D41/4 NPT1/4 NPTThreaded14.130.40 to 140Not Rated5 1/4"2 1/2"3 1/2"Panel, Screw In1 3/8"No0.22"6650K1100000
    D43/8 NPT3/8 NPTThreaded38.851.10 to 140Not Rated5 7/8"2 7/8"4 1/8"Panel, Screw In1 5/8"No0.28"6650K12000000
    D41/2 NPT1/2 NPTThreaded109.483.10 to 140Not Rated6 3/8"4"4 7/8"Panel, Screw In2"No0.26"6650K13000000
     

    Two-Action Electrically Operated Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Two-Action Electrically Operated Air Directional Control Valves.
    Also known as 4-way and 5/2 valves, these valves create two actions, such as extending and then retracting a double-acting cylinder. Apply voltage to the electrical connection to actuate. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by spring, so they return to their original position as soon as voltage is removed.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Mounting
    Location
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Choose a Voltage
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Single Solenoid—Spring Return
    41/4 NPT1/4 NPTThreaded450.7544 to 145Not Rated5 1/16"7/8"1 3/8"Screw InInlineNo0.19"12V DC, 24V DC, 120V AC62095K80000000
     

    Solenoid-Operated Block-Mount Hydraulic Directional Control Valves

    Direct flow with an electronic signal. Use screws to attach to an NFPA valve-mounting block (each component sold separately).
    In NFPA diagrams, P represents the pressure source, T represents the tank, and A and B represent work ports.
    Single-Solenoid 4-Way Valves—2 Flow Positions (4/2 Valves)
    Image of Product. Front orientation. Directional Control Valves. Solenoid-Operated Block-Mount Hydraulic Directional Control Valves , 4 Way, 2 Flow Positions.
    Image of Specification. Front orientation. Contains Annotated. Directional Control Valves. Solenoid-Operated Block-Mount Hydraulic Directional Control Valves , 4 Way, 2 Flow Positions, Style 1.
    Image of Specification. Front orientation. Contains Annotated. Directional Control Valves. Solenoid-Operated Block-Mount Hydraulic Directional Control Valves , 4 Way, 2 Flow Positions, Style 2.
    Image of Specification. D03 Mounting Pattern. Bottom orientation. D03. Solenoid-Operated Block-Mount Hydraulic Directional Control Valves .
    Image of Specification. D05 Mounting Pattern. Bottom orientation. D05. Solenoid-Operated Block-Mount Hydraulic Directional Control Valves .

    Style 1

    Style 2

    D03 Mounting Pattern

    D05 Mounting Pattern

    Valves
    Screws
    Style
    NFPA Mounting
    Pattern
    ISO Mounting
    Pattern
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Choose a Voltage
    Each
    Pkg.
    Qty.
    Pkg.
    Default Position P Open to A, B Open to T
    1D0303205,00012V DC, 24V DC, 120V AC49995K49000000041945N1200000
    1D0505405,00012V DC, 24V DC, 120V AC49995K5900000041945N150000
     
    Default Position P Open to B, A Open to T
    2D0303205,00012V DC, 24V DC, 120V AC49995K5800000041945N120000
    2D0505405,00012V DC, 24V DC, 120V AC49995K6700000041945N150000
     
    Double-Solenoid 4 Way Valves—3 Flow Positions (4/3 Valves)
    Image of Specification. Front orientation. Contains Annotated. Directional Control Valves. Solenoid-Operated Block-Mount Hydraulic Directional Control Valves , 4 Way, 3 Flow Positions, Style 3.
    Image of Specification. Front orientation. Contains Annotated. Directional Control Valves. Solenoid-Operated Block-Mount Hydraulic Directional Control Valves , 4 Way, 3 Flow Positions, Style 4.
    Image of Specification. Front orientation. Contains Annotated. Directional Control Valves. Solenoid-Operated Block-Mount Hydraulic Directional Control Valves , 4 Way, 3 Flow Positions, Style 5.
    Image of Specification. Front orientation. Contains Annotated. Directional Control Valves. Solenoid-Operated Block-Mount Hydraulic Directional Control Valves , 4 Way, 3 Flow Positions, Style 6.

    Style 3

    Style 4

    Style 5

    Style 6

    Image of Specification. Front orientation. Contains Annotated. Directional Control Valves. Solenoid-Operated Block-Mount Hydraulic Directional Control Valves , 4 Way, 3 Flow Positions, Style 7.
    Image of Specification. Front orientation. Contains Annotated. Directional Control Valves. Solenoid-Operated Block-Mount Hydraulic Directional Control Valves , 4 Way, 3 Flow Positions, Style 8.
    Image of Specification. Front orientation. Contains Annotated. Directional Control Valves. Solenoid-Operated Block-Mount Hydraulic Directional Control Valves , 4 Way, 3 Flow Positions, Style 9.
    Image of Specification. Front orientation. Contains Annotated. Directional Control Valves. Solenoid-Operated Block-Mount Hydraulic Directional Control Valves , 4 Way, 3 Flow Positions, Style 10.

    Style 7

    Style 8

    Style 9

    Style 10

    Image of Specification. D03 Mounting Pattern. Bottom orientation. D03. Solenoid-Operated Block-Mount Hydraulic Directional Control Valves .
    Image of Specification. D05 Mounting Pattern. Bottom orientation. D05. Solenoid-Operated Block-Mount Hydraulic Directional Control Valves .
    Image of Specification. D08 Mounting Pattern. Bottom orientation. D08. Solenoid-Operated Block-Mount Hydraulic Directional Control Valves .

    D03 Mounting Pattern

    D05 Mounting Pattern

    D08 Mounting Pattern

    Valves
    Screws
    Style
    NFPA Mounting
    Pattern
    ISO Mounting
    Pattern
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Choose a Voltage
    Each
    Pkg.
    Qty.
    Pkg.
    Default Position Closed
    3D0303205,00012V DC, 24V DC, 120V AC49995K5000000041945N1200000
    3D0505405,00012V DC, 24V DC, 120V AC49995K900000041945N150000
    4D08081605,00012V DC, 24V DC, 120V AC49995K270000000061945N1800000
     
    Default Position Open
    5D0303205,00012V DC, 24V DC, 120V AC49995K600000041945N120000
    5D0505405,00012V DC, 24V DC, 120V AC49995K1700000041945N150000
    6D08081605,00012V DC, 24V DC, 120V AC49995K290000000061945N1800000
     
    Default Position P Closed, A and B Open to T
    7D0303105,00012V DC, 24V DC, 120V AC49995K700000041945N120000
    7D0505405,00012V DC, 24V DC, 120V AC49995K1800000041945N150000
    8D08081605,00012V DC, 24V DC, 120V AC49995K470000000061945N1800000
     
    Default Position P Open to T, A and B Closed
    9D0303155,00012V DC, 24V DC, 120V AC49995K800000041945N120000
    9D0505105,00012V DC, 24V DC, 120V AC49995K1900000041945N150000
    10D0808805,00012V DC, 24V DC, 120V AC49995K480000000061945N1800000
     
    Replacement Solenoid Coils

    Two-Speed Two-Action Air Directional Control Valves with Full Shut-Off

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves with Full Shut-Off, Style A.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves with Full Shut-Off, Style B.

    Style A

    Style B

    These valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Also known as 4-way and 5/3 closed center valves.
    Spring Return—Valves with spring return actuation return to their original position as soon as you release the actuator.
    Hand Return—Valves with hand return actuation stay actuated and return to their original position only when you move the actuator again.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    Style
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount Type
    For Panel
    Cutout Dia.
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Spring Return
    A51/4 NPT1/4 NPTThreaded45.51.30 to 145Not Rated4 3/4"2 1/16"4 3/4"Panel, Screw In1"No0.26"3368K290000000
    A51/4 NPT1/4 NPTThreaded65.341.714 to 14528 in. Hg1"2"3 7/8"Unthreaded Through HoleNo0.17"6859K77000000
    A53/8 NPT3/8 NPTThreaded65.341.714 to 14528 in. Hg1"2"3 7/8"Unthreaded Through HoleNo0.17"6859K78000000
    B51/4 NPT1/4 NPTThreaded450.750 to 120Not Rated6 1/4"2"5 5/8"Screw InNo0.22"4493K44000000
     
    Hand Return
    A51/8 NPT1/8 NPTThreaded17.50.50 to 145Not Rated3 3/4"1 5/8"3 3/4"Panel, Screw In3/4"No0.22"3368K15000000
    A51/4 NPT1/4 NPTThreaded45.51.30 to 145Not Rated4 3/4"2 1/16"4 3/4"Panel, Screw In1"No0.26"3368K26000000
    A51/4 NPT1/4 NPTThreaded65.341.714 to 14528 in. Hg1"2"3 7/8"Unthreaded Through HoleNo0.17"6859K79000000
    A53/8 NPT3/8 NPTThreaded65.341.714 to 14528 in. Hg1"2"3 7/8"Unthreaded Through HoleNo0.17"6859K81000000
     

    Two-Speed Two-Action Air-Operated Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air-Operated Air Directional Control Valves.
    Often used to extend and then retract a cylinder at different speeds, these valves create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Also known as pilot valves and 4-way valves, they use an air signal to actuate, so they're good for environments where electrical use may be dangerous. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion.
    Spring Return—Valves with spring return actuation go back to their starting position as soon as the air supply is removed.
    Air-Assisted Spring Return—Valves with air-assisted spring return actuation require you to supply air to port P to go back to their starting position.
    Air Return—Valves with air return actuation go back to their starting position when the air supply is moved from the first air pilot to the second air pilot.
    NPTF Inlet Thread—NPTF (Dryseal) threads are compatible with NPT threads.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    Min. Actuation
    Pressure, psi
    No. of Flow
    Ports
    No. of Air
    Pilot Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Air Pilot
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Vacuum Rating,
    in. Hg
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Threaded Female Inlet x Threaded Female Outlet × Threaded Female Air Pilot
     
    Spring Return
    44513/8 NPTF3/8 NPTFThreaded1/8 NPT53.11.60 to 150106 1/8"1 1/4"2 1/4"Screw InNo0.27"6124K350000000
     
    Air-Assisted Spring Return
    44511/8 NPT1/8 NPTThreaded1/8 NPT43.11.30 to 145264 1/8"7/8"1 3/8"Screw InNo0.18"6124K404000000
    44511/4 NPT1/4 NPTThreaded1/8 NPT43.11.30 to 145265 1/8"1"1 5/8"Screw InNo0.18"6124K405000000
    44511/2 NPTF1/2 NPTFThreaded1/8 NPT165.950 to 150266 5/8"1 1/2"2 1/2"Screw InNo0.27"6124K36000000
    445110-32 UNF10-32 UNFThreaded10-32 UNF8.60.260 to 150262 3/8"5/8"1"Screw InNo0.1"6124K76000000
     
    Air Return
    29521/8 NPT1/8 NPTThreaded1/8 NPT43.11.30 to 145264 1/8"7/8"1 3/8"Screw InNo0.18"6124K407000000
    29521/4 NPT1/4 NPTThreaded1/8 NPT43.11.30 to 145265"1"1 5/8"Screw InNo0.18"6124K408000000
    29523/8 NPTF3/8 NPTFThreaded1/8 NPT53.11.60 to 150106 5/8"1 1/4"2 1/4"Screw InNo0.27"6124K45000000
    29521/2 NPTF1/2 NPTFThreaded1/8 NPT165.950 to 150266 5/8"1 1/2"2 1/2"Screw InNo0.27"6124K46000000
    295210-32 UNF10-32 UNFThreaded10-32 UNF8.60.260 to 150262 3/8"5/8"1"Screw InNo0.1"6124K79000000
     

    Single-Action Mechanically Operated Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style A.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style B.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style C.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style D.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style E.

    Style A

    Style B

    Style C

    Style D

    Style E

    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style F.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style G.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style H.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style J.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style K.

    Style F

    Style G

    Style H

    Style J

    Style K

    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style L.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style M.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style N.

    Style L

    Style M

    Style N

    A simple automation solution that requires no programming, these valves are activated when an object, such as a box rolling on a conveyor, pushes the actuator. Also known as 3-way and 3/2 valves, they create one action, such as extending a cylinder. Valves direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by spring, so they go back to their starting position as soon as the actuator is released. In the off position, they exhaust air pressure from the system, allowing equipment to reset so the action can be repeated.
    Threaded Female Inlet x Threaded Female Outlet
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style A.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style C.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style D.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style E.

    Style A

    Style C

    Style D

    Style E

    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style F.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style G.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style H.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style J.

    Style F

    Style G

    Style H

    Style J

    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style K.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style L.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style M.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style N.

    Style K

    Style L

    Style M

    Style N

    1-Direction Actuation—Valves with a one-direction actuator are activated by objects from one side.
    2-Direction Actuation—Valves with a two-direction actuator are activated by objects from both sides.
    Valve Position—Fail-closed valves block airflow until actuated. Valves that are both fail closed and fail open can be installed to block airflow, or allow air to flow until actuated.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    For Panel
    Cutout
    Style
    Actuation
    Force, lbf
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Wd.
    Mounting Fasteners
    Included
    Each
    1-Direction Actuation
     
    Fail Open/Fail Closed
    C131/8 NPT1/8 NPTThreaded60.110 to 12029.9 in. Hg2 1/4"3/4"2 1/8"1 3/4"3/4"No6464K21000000
    E2.831/8 NPT1/8 NPTThreaded60.110 to 12029.9 in. Hg2 1/8"1 3/4"4 1/4"1 3/4"3/4"No6464K24000000
     
    2-Direction Actuation
     
    Fail Closed
    D1.5731/8 BSPP1/8 BSPPThreaded29.740.840 to 14528 in. Hg43.7 mm50.4 mm113.7 mm28 mm28 mmNo6464K93000000
    F731/8 NPT1/8 NPTThreaded190.340 to 15026.5 in. Hg2 3/8"7/8"4"1 3/8"7/8"No6464K31000000
    F10.131/4 NPT1/4 NPTThreaded550.980 to 15026.5 in. Hg3"1 1/8"4 7/8"1 3/8"7/8"No6464K32000000
    G1131/4 NPTF1/4 NPTFThreaded531.60 to 15029 in. Hg2 1/8"3"6 5/32"2 1/8"1 1/4"No6859K36000000
    K1831/4 NPTF1/4 NPTFThreaded531.60 to 15029 in. Hg2 1/8"1 1/4"5 5/32"2 1/8"1 1/4"No6859K35000000
    M1.5731/8 BSPP1/8 BSPPThreaded4.230.1253 to 120Not Rated36 mm18 mm220 mm19 mmNo6464K92000000
     
    Fail Open/Fail Closed
    A1.231/8 NPT1/8 NPTThreaded60.110 to 12029.9 in. Hg2 1/4"3/4"1 1/4"1 3/4"3/4"No6464K1200000
    C131/8 NPT1/8 NPTThreaded60.110 to 12029.9 in. Hg2 1/4"3/4"1 5/8"1 3/4"3/4"No6464K1300000
    H2.531/8 NPT1/8 NPTThreaded60.110 to 12029.9 in. Hg1 3/4"3/4"1"1/8"1 3/4"3/4"No6464K1100000
    J2.531/8 NPT1/8 NPTThreaded60.110 to 12029.9 in. Hg1 3/4"3/4"2"1/2"1 3/4"3/4"Yes6464K1400000
    L2.831/8 NPT1/8 NPTThreaded60.110 to 12029.9 in. Hg1 3/4"3/4"2 1/4"1/2"1 3/4"3/4"Yes6464K22000000
    N2.531/8 NPT1/8 NPTThreaded60.110 to 12029.9 in. Hg1 3/4"3/4"1 3/4"1/2"1 3/4"3/4"Yes6464K2300000
     
    Barbed Male Inlet x Barbed Male Outlet
    Image of Product. Front orientation. Directional Control Valves. Single-Action Mechanically Operated Air Directional Control Valves , Style B.

    Style B

    1-Direction Actuation—Valves with a one-direction actuator are activated by objects from one side.
    2-Direction Actuation—Valves with a two-direction actuator are activated by objects from both sides.
    Valve Position—Fail-closed valves block airflow until actuated. Valves that are both fail closed and fail open can be installed to block airflow, or allow air to flow until actuated.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall,
    mm
    For Panel
    Cutout, mm
    Style
    Actuation
    Force, lbf
    No. of Flow
    Ports
    For Inlet
    Tube ID, mm
    For Outlet
    Tube ID, mm
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Lg.
    Wd.
    Mounting Fasteners
    Included
    Each
    1-Direction Actuation
     
    Fail Closed
    B1.3532.52.5Barbed
    0.050 to 116Not Rated27.81141.328.69.5No1389T14000000
     
    2-Direction Actuation
     
    Fail Closed
    B1.3532.52.5Barbed
    1.60.050 to 116Not Rated27.81131.6828.69.5No1389T1300000
     

    Two-Action Air Directional Control Valves with Full Shut-Off

    Image of Product. Front orientation. Directional Control Valves. Two-Action Air Directional Control Valves with Full Shut-Off.
    These valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place. Also known as 4-way and 4/3 closed-center valves, they create two actions, such as extracting and then retracting a double-acting cylinder. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by hand, so valves stay actuated and return to their original position only when you move the actuator again.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Hand Return
    41/4 NPT1/4 NPTThreaded1253.40 to 145Not Rated5 5/8"4"4 3/4"Screw InNo0.26"62365K61000000
    43/8 NPT3/8 NPTThreaded7030 to 150Not Rated6 7/8"4 3/4"3 3/4"Screw InNo0.34"62365K63000000
    43/8 NPT3/8 NPTThreaded7030 to 250Not Rated6 7/8"4 3/4"3 3/4"Screw InNo0.34"62365K122000000
    41/2 NPT1/2 NPTThreaded1456.20 to 150Not Rated9"5 5/8"4 1/2"Screw InNo0.34"62365K65000000
    41/2 NPT1/2 NPTThreaded1456.20 to 250Not Rated9"5 5/8"4 1/2"Screw InNo0.34"62365K132000000
     

    Modular Air Directional Control Valves with Air Manifolds

    Image of System. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air Manifolds.
    Mount valves to a single-station base or to a manifold, which allows a single pressure source for multiple valves, then add or remove valves as your needs change. Valves with the same style can be used on the same manifold. For example, you can put a Style B, 2-position, spring-return valve and a Style B, 3-position, solenoid-return valve on the same manifold.
    3-Way Valves
    Image of Product. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air Manifolds, 3 Way.
    3-way valves create one action, such as extending a cylinder.
    Fail-Closed Valve—Fail-closed valves block airflow until actuated.
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    Style
    No. of
    Valves
    No. of Flow
    Ports
    No. of Flow
    Positions
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Lg.
    Wd.
    Ht.
    Body
    Material
    Mounting Fasteners
    Included
    Choose a Voltage
    Each
    3/2 Flow Pattern—Fail-Closed Valve
     
    Single Solenoid—Spring Return
    A1325.9940.19-14 to 14.529.92 11/16"3/4"3 1/16"Aluminum
    Yes12V DC, 24V DC, 110V AC61975K56000000
     
    4-Way Valves
    Image of Product. Single Solenoid Valve with Wire Leads. Front orientation. Single Solenoid. Modular Air Directional Control Valves with Air Manifolds, 4 Way.
    Image of Product. Double Solenoid Valve. Front orientation. Double Solenoid. Modular Air Directional Control Valves with Air Manifolds, 4 Way.

    Single Solenoid Valve

    with Wire Leads

    Double Solenoid Valve

    4-way valves create two actions, such as extending and then retracting a double-acting cylinder.
    5/3 (Closed Center) Flow Pattern—5/3 (closed center) valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place.
    5/3 (Exhaust Center) Flow Pattern—5/3 (exhaust center) valves exhaust all air pressure in the off position, allowing equipment to return to the neutral position.
    5/3 (Pressure Center) Flow Pattern—5/3 (pressure center) valves create two actions at the same time, such as extending two single-acting cylinders at once.
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    Style
    No. of
    Valves
    No. of Flow
    Ports
    No. of Flow
    Positions
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Wire
    Connection
    Lg.
    Wd.
    Ht.
    Body
    Material
    Mounting Fasteners
    Included
    Choose a
    Voltage
    Each
    5/2 Flow Pattern
     
    Single Solenoid—Spring Return
    B15280.2421 to 101Not RatedWire Leads2 5/8"3/8"1 1/8"Zinc AlloyYes24V DC, 110V AC62165K83000000
    C152200.6421 to 101Not RatedWire Leads3 3/8"5/8"1 1/8"Aluminum
    Yes24V DC, 110V AC62165K8800000
    D15235121 to 101Not RatedWire Leads4"3/4"1 1/4"Aluminum
    Yes24V DC, 110V AC62165K9400000
     
    Double Solenoid—Solenoid Return
    B15280.2421 to 101Not RatedWire Leads3 1/2"3/8"1 1/8"Zinc AlloyYes24V DC, 110V AC62165K8400000
    C152200.6421 to 101Not RatedWire Leads4 1/4"5/8"1 1/8"Aluminum
    Yes24V DC, 110V AC62165K8900000
    D15235121 to 101Not RatedWire Leads4 3/4"3/4"1 1/4"Aluminum
    Yes24V DC, 110V AC62165K9500000
     
    5/3 (Closed Center) Flow Pattern
     
    Double Solenoid—Solenoid Return
    B15360.1829 to 101Not RatedWire Leads3 7/8"3/8"1 1/8"Zinc AlloyYes24V DC, 110V AC62165K8500000
    C153150.4729 to 101Not RatedWire Leads4 3/4"5/8"1 1/8"Aluminum
    Yes24V DC, 110V AC62165K9100000
    D153230.7229 to 101Not RatedWire Leads5 1/4"3/4"1 1/4"Aluminum
    Yes24V DC, 110V AC62165K9600000
     
    5/3 (Exhaust Center) Flow Pattern
     
    Double Solenoid—Solenoid Return
    B15360.1829 to 101Not RatedWire Leads3 7/8"3/8"1 1/8"Zinc AlloyYes24V DC, 110V AC62165K8600000
    C153140.4429 to 101Not RatedWire Leads4 3/4"5/8"1 1/8"Aluminum
    Yes24V DC, 110V AC62165K9200000
    D153230.7129 to 101Not RatedWire Leads5 1/4"3/4"1 1/4"Aluminum
    Yes24V DC, 110V AC62165K9700000
     
    5/3 (Pressure Center) Flow Pattern
     
    Double Solenoid—Solenoid Return
    B15380.2429 to 101Not RatedWire Leads3 7/8"3/8"1 1/8"Zinc AlloyYes24V DC, 110V AC62165K8700000
    C153150.4829 to 101Not RatedWire Leads4 3/4"5/8"1 1/8"Aluminum
    Yes24V DC, 110V AC62165K9300000
    D153200.6329 to 101Not RatedWire Leads5 1/4"3/4"1 1/4"Aluminum
    Yes24V DC, 110V AC62165K9800000
     
    Manifolds
    Image of Product. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air Manifolds, Manifolds.
    Manifolds connect multiple valves to a common input pressure source and exhaust port.
    NPTF Inlet Thread—NPTF (Dryseal) threads are compatible with NPT threads.
    Number
    of Ports
    Overall
    For
    Style
    Inlet
    Exhaust
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Wd.
    Ht.
    Mounting Fasteners
    Included
    Choose a Number
    of Stations
    Each
    Threaded Female Inlet x Threaded Female Outlet
    A221/8 NPTF1/8 NPTFThreaded1 1/2"1"Yes2, 3, 461975K42000000
    A221/8 NPTF1/8 NPTFThreaded1 1/2"1"Yes5, 6, 7, 8, 9, 1061975K4300000
    B241/8 NPT1/8 NPTThreaded2 1/4"1 1/4"Yes2, 3, 462165K400000
    B241/8 NPT1/8 NPTThreaded2 1/4"1 1/4"Yes5, 6, 7, 8, 9, 1062165K500000
    C241/4 NPT1/4 NPTThreaded2 5/8"1 1/2"Yes2, 3, 462165K600000
    C241/4 NPT1/4 NPTThreaded2 5/8"1 1/2"Yes5, 6, 7, 8, 9, 1062165K700000
    D241/4 NPT1/4 NPTThreaded2 7/8"1 5/8"Yes2, 3, 462165K800000
    D241/4 NPT1/4 NPTThreaded2 7/8"1 5/8"Yes5, 6, 7, 8, 9, 1062165K900000
     
    Single Station Bases
    Image of Product. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air Manifolds, Single Station Bases.
    Use single station bases to mount a single valve.
    NPTF Inlet Thread—NPTF (Dryseal) threads are compatible with NPT threads.
    Number
    of Ports
    Overall
    For
    Style
    No. of Flow
    Ports
    Inlet
    Outlet
    Exhaust
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Lg.
    Wd.
    Ht.
    Body
    Material
    Mounting Fasteners
    Included
    No. of
    Stations
    Each
    Threaded Female Inlet × Threaded Female Outlet
    A31111/8 NPTF1/8 NPTFThreaded1 3/8"1"3/4"Aluminum
    No161975K81000000
    B51221/8 NPT1/8 NPTThreaded1 5/8"7/8"1"Aluminum
    No162165K7100000
    C51221/4 NPT1/4 NPTThreaded2 1/4"1 3/8"7/8"Aluminum
    No162165K7200000
    D51221/4 NPT1/4 NPTThreaded2 3/4"1 3/4"1"Aluminum
    No162165K7300000
     
    Station Plates
    Image of Product. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air Manifolds, Station Plates.
    Station plates cover unused manifold ports.
    For
    Style
    Body
    Material
    Each
    ASteel61975K600000
    BZinc Alloy62165K160000
    CZinc Alloy62165K260000
    DZinc Alloy62165K360000
     

    Single-Action Air-Operated Air Directional Control Valves

    These valves create one action, such as extending a cylinder. Also known as 3/2 or pilot valves, they use an air signal to actuate, so they're good for environments where electrical use may be dangerous. They direct airflow from an inlet to your equipment and exhaust return airflow to create motion. In the off position, they exhaust air pressure from the system, allowing equipment to reset so the action can be repeated.
    Threaded Female Inlet x Threaded Female Outlet × Threaded Female Air Pilot
    Image of Product. Front orientation. Directional Control Valves. Single-Action Air-Operated Air Directional Control Valves.
    Spring Return—Valves with spring return actuation go back to their starting position as soon as the air supply is removed.
    Air Return—Valves with air return actuation go back to their starting position when the air supply is moved from the first air pilot to the second air pilot.
    Valve Position—Fail-closed valves normally block airflow, and remain closed until actuated. Valves that are both fail closed and fail open can be installed to normally block airflow, or to normally allow flow and remain open until actuated.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    Min. Actuation
    Pressure, psi
    No. of Flow
    Ports
    No. of Air
    Pilot Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Air Pilot
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Vacuum Rating,
    in. Hg
    Lg.
    Wd.
    Ht.
    Mounting Fasteners
    Included
    Each
    Fail Closed
     
    Spring Return
    44311/8 NPT1/8 NPTThreaded1/8 NPT24.90.750 to 145263 1/2"7/8"1 3/8"No6124K4030000000
    44311/4 NPT1/4 NPTThreaded1/8 NPT24.90.750 to 145264 1/4"1"1 5/8"No6124K401000000
    44313/8 NPTF3/8 NPTFThreaded1/8 NPT53.11.60 to 150105 1/8"1 1/4"2 1/4"No6124K32000000
     
    Fail Open/Fail Closed
     
    Air Return
    29321/8 NPT1/8 NPTThreaded1/8 NPT24.90.750 to 145263 1/2"7/8"1 3/8"No6124K406000000
    29321/4 NPT1/4 NPTThreaded1/8 NPT24.90.750 to 145264 1/8"1"1 5/8"No6124K402000000
    29323/8 NPTF3/8 NPTFThreaded1/8 NPT53.11.60 to 150105 1/2"1 1/4"2 1/4"No6124K42000000
     

    Modular Air Directional Control Valves with Air and Electrical Manifolds

    Image of System. Complete System Shown with M12 Electrical Connection. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air and Electrical Manifolds .

    Complete System Shown with M12

    Electrical Connection

    Mix and match valve styles on one manifold to meet your control needs. Mount multiple valves to a manifold to reduce piping requirements and create multiple actions from a single pressure input. Add or remove valves as your needs change.
    3-Way Valves
    Image of Product. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air and Electrical Manifolds , 3 Way.
    3-way valves create one action, such as extending a cylinder. They have four flow positions, which allows the valve to operate as two independent valves from a single station on the manifold.
    Fail-Closed Valve—Fail-closed valves block airflow until actuated.
    Air Return—Valves with air return actuation go back to their starting position when the air supply is moved from the first air pilot to the second air pilot.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of
    Valves
    Return
    Actuation
    No. of Flow
    Ports
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Voltage,
    V DC
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Body
    Material
    Mounting Fasteners
    Included
    Each
    3/2 Flow Pattern—Fail-Closed Valve
    2Air3148.41122 to 102Not Rated244 1/16"11/16"2 3/16"ManifoldAluminum
    Yes2866N26000000
     
    4-Way Valves
    Image of Product. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air and Electrical Manifolds , 4 Way.
    4-way valves create two actions, such as extending and then retracting a double-acting cylinder.
    5/3 (Closed Center) Flow Pattern—5/3 (closed center) valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place.
    5/3 (Exhaust Center) Flow Pattern—5/3 (exhaust center) valves exhaust all air pressure in the off position, allowing equipment to return to the neutral position.
    5/3 (Pressure Center) Flow Pattern—5/3 (pressure center) valves create two actions at the same time, such as extending two single-acting cylinders at once.
    Air Return—Valves with air return actuation go back to their starting position when the air supply is moved from the first air pilot to the second air pilot.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of
    Valves
    Return
    Actuation
    No. of Flow
    Ports
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Voltage,
    V DC
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Body
    Material
    Mounting Fasteners
    Included
    Each
    5/2 Flow Pattern
    1Air5167122 to 102Not Rated244 1/16"11/16"2 3/16"ManifoldAluminum
    Yes2866N24000000
    1Solenoid5166.97115 to 102Not Rated244 1/16"11/16"2 3/16"ManifoldAluminum
    Yes2866N2500000
     
    5/3 (Closed Center) Flow Pattern
    1Solenoid5167129 to 102Not Rated244 5/8"3/4"2 7/8"ManifoldAluminum
    Yes2866N2700000
     
    5/3 (Exhaust Center) Flow Pattern
    1Solenoid5167129 to 102Not Rated244 5/8"3/4"2 7/8"ManifoldAluminum
    Yes2866N2800000
     
    5/3 (Pressure Center) Flow Pattern
    1Solenoid5167129 to 102Not Rated244 5/8"3/4"2 7/8"ManifoldAluminum
    Yes2866N2900000
     
    Manifolds
    Image of Product. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air and Electrical Manifolds , Manifolds, DB25 Connection.
    Image of Product. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air and Electrical Manifolds , Manifolds, M12 Connection.

    DB25 Connection

    M12 Connection

    Manifolds connect multiple valves to a common input pressure source and exhaust port.
    IP40 Enclosure Rating—IP40 rated manifolds are protected from coarse particles larger than 1 mm.
    IP67 Enclosure Rating—IP67 rated manifolds are dust tight and protected from temporary submersion.
    Number
    of Ports
    Overall
    No. of
    Stations
    No. of Flow
    Ports
    Inlet
    Outlet
    Exhaust
    For Inlet
    Tube OD
    For Outlet
    Tube OD
    Exhaust
    Connection
    Voltage,
    V DC
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Body
    Material
    For DIN
    Rail Size, mm
    Mounting Fasteners
    Included
    Each
    Push-to-Connect Female Inlet × Push-to-Connect Female Outlet
     
    DB25 (IP40)
    282423/8"1/4"Push to Connect244 1/2"4 1/2"3"Screw InAluminum
    35Yes2866N50000000
    4122823/8"1/4"Push to Connect245 1/2"4 1/2"3"Screw InAluminum
    35Yes2866N6000000
    61621223/8"1/4"Push to Connect246 3/4"4 1/2"3"Screw InAluminum
    35Yes2866N7000000
    82021623/8"1/4"Push to Connect248"4 1/2"3"Screw InAluminum
    35Yes2866N8000000
     
    M12 (IP67)
    282423/8"1/4"Push to Connect244 3/4"4 1/2"3"Screw InAluminum
    35Yes2866N1000000
    4122823/8"1/4"Push to Connect246"4 1/2"3"Screw InAluminum
    35Yes2866N20100000000
    61621223/8"1/4"Push to Connect247 1/4"4 1/2"3"Screw InAluminum
    35Yes2866N30100000000
    82021623/8"1/4"Push to Connect248 1/2"4 1/2"3"Screw InAluminum
    35Yes2866N40100000000
     
    Station Plates
    Image of Product. Front orientation. Directional Control Valves. Modular Air Directional Control Valves with Air and Electrical Manifolds , Station Plates.
    Station plates cover unused manifold ports.
    Body
    Material
    Each
    Polybutylene2866N2300000
     

    Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Full Shut-Off

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Full Shut-Off, Style A.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Full Shut-Off, Style B.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Full Shut-Off, Style C.

    Style A

    Style B

    Style C

    These valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Apply voltage to the electrical connection to actuate. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Also known as 4-way and 5/3 closed center valves.
    Threaded Female Inlet × Threaded Female Outlet—Threaded Exhaust
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Full Shut-Off, Style A.

    Style A

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Full Shut-Off, Style B.

    Style B

    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    NPTF Inlet Thread—NPTF (Dryseal) threads are compatible with NPT threads.
    Manifold Mount—Manifold-mount valves plug into a manifold (sold separately) to create multiple actions from a single pressure input. Manifolds with multiple exhaust ports have one set of inlet and exhaust ports on each side, so they can be strung together in a series. When using a single manifold, cover the ports on the side you are not using with plugs (sold separately).
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Valves
    Replacement
    Solenoid Valve Plugs
    Overall
    Style
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount Type
    For Manifold
    Style
    Choose a Voltage
    Each
    Each
    Double Solenoid—Solenoid Return
    A51/8 NPT1/8 NPT280.544 to 145Not Rated7 1/2"7/8"1 3/8"Manifold, Screw In112V DC, 24V DC, 120V AC6124K200000006124K30100000
    A51/8 NPTF1/8 NPTF56115 to 15028 in. Hg8 5/8"7/8"2 3/4"Manifold, Screw In224V DC, 120V AC6425K17000000———0
    A51/4 NPT1/4 NPT530.9544 to 145Not Rated8 1/2"1"1 5/8"Manifold, Screw In312V DC, 24V DC, 120V AC6124K30000006124K3010000
    A51/4 NPTF1/4 NPTF56115 to 15028 in. Hg8 5/8"7/8"2 3/4"Manifold, Screw In224V DC, 120V AC6425K18000000———0
    A51/4 NPTF1/4 NPTF95.21.715 to 15028 in. Hg9 3/8"1"3"Manifold, Screw In424V DC, 120V AC6425K27000000———0
    A53/8 NPTF3/8 NPTF95.21.715 to 15028 in. Hg9 3/8"1"3"Manifold, Screw In424V DC, 120V AC6425K28000000———0
    B53/8 NPT3/8 NPT931.6745 to 150Not Rated9 3/8"1 1/4"4 3/4"Screw In24V DC, 120V AC6124K4000000———0
     
    Accessories for Valves
    Push-to-Connect Female Inlet × Push-to-Connect Female Outlet—Push-to-Connect Exhaust
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Full Shut-Off, Style C.

    Style C

    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    Style
    No. of Flow
    Ports
    For Inlet
    Tube OD, mm
    For Outlet
    Tube OD, mm
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Voltage,
    V DC
    Each
    Double Solenoid—Spring Return
    C56617.50.3144 to 10129.523 1/4"7/16"2 1/8"Screw In244658A330000000
     
    Directional Control Valve Station Plates

    Two-Speed Two-Action Air Directional Control Valves with Exhausting Shut-Off

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves with Exhausting Shut-Off, Style A.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air Directional Control Valves with Exhausting Shut-Off, Style B.

    Style A

    Style B

    In the off position, these valves exhaust all air pressure, allowing the equipment to return to the neutral position. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Valves without an exhaust connection exhaust air to the atmosphere. Also known as 4-way and 5/3 exhaust center valves.
    Spring Return—Valves with spring return actuation return to their original position as soon as you release the actuator.
    Hand Return—Valves with hand return actuation stay actuated and return to their original position only when you move the actuator again.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    Style
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount Type
    For Panel
    Cutout Dia.
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Spring Return
    B51/4 NPT1/4 NPTThreaded3510 to 145Not Rated4 3/4"2 1/16"4 3/4"Panel, Screw In1"No0.26"3368K310000000
    B51/4 NPT1/4 NPTThreaded65.341.714 to 14528 in. Hg1"2"3 15/16"Screw InNo0.17"6859K73000000
    B53/8 NPT3/8 NPTThreaded65.341.714 to 14528 in. Hg1"2"3 15/16"Screw InNo0.17"6859K74000000
     
    Hand Return
    A51/8 NPT1/8 NPT7.50.1330 to 150Not Rated7/8"5/8"2 1/2"Panel, Screw In5/8"Yes0.17"62475K4600000
    A510-32 UNF10-32 UNF7.50.1330 to 150Not Rated7/8"5/8"2 1/2"Panel, Screw In5/8"Yes0.17"62475K4500000
    B51/8 NPT1/8 NPTThreaded17.50.50 to 145Not Rated3 3/4"1 5/8"3 3/4"Panel, Screw In3/4"No0.22"3368K16000000
    B51/4 NPT1/4 NPTThreaded45.51.30 to 145Not Rated4 3/4"2 1/16"4 3/4"Panel, Screw In1"No0.26"3368K27000000
    B51/4 NPT1/4 NPTThreaded65.341.714 to 14528 in. Hg1"2"3 15/16"Screw InNo0.17"6859K75000000
    B53/8 NPT3/8 NPTThreaded65.341.714 to 14528 in. Hg1"2"3 15/16"Screw InNo0.17"6859K76000000
     

    Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Exhausting Shut-Off

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Exhausting Shut-Off, NPT Inlet Thread, NPT Outlet Thread.

    NPT Inlet Thread

    NPT Outlet Thread

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Electrically Operated Air Directional Control Valves with Exhausting Shut-Off, NPTF Inlet Thread, NPTF Outlet Thread.

    NPTF Inlet Thread

    NPTF Outlet Thread

    In the off position, these valves exhaust all air pressure, allowing the equipment to return to the neutral position. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Also known as 5/3 exhaust-center valves, they actuate when voltage is applied to the electrical connection. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is electric (solenoid), so they go back to their original position when voltage moves from the first solenoid to the second solenoid.
    NPT Inlet Thread—Solenoid connectors are not included for NPT × NPT valves.
    NPTF Inlet Thread—NPTF (Dryseal) threads are compatible with NPT threads.
    Manifold Mount—Manifold-mount valves plug into a manifold (sold separately) to create multiple actions from a single pressure input. Manifolds with multiple exhaust ports have one set of inlet and exhaust ports on each side, so they can be strung together in a series. When using a single manifold, cover the ports on the side you are not using with plugs (sold separately).
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Specs. Met
    Lg.
    Wd.
    Ht.
    Mount Type
    For Manifold
    Style
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Choose a
    Voltage
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Double Solenoid—Solenoid Return
    51/8 NPT1/8 NPTThreaded190.643 to 145Not RatedEN 175301-8038 3/4"7/8"2 5/8"Screw InYes0.16"24V DC2842N110000000
    51/8 NPT1/8 NPTThreaded190.643 to 145Not RatedEN 175301-8038 3/4"7/8"2 5/8"Screw InYes0.16"120V AC2842N12000000
    51/8 NPTF1/8 NPTFThreaded56115 to 15028 in. Hg8 5/8"7/8"2 3/4"Manifold, Screw In2No0.13"24V DC, 120V AC6425K15000000
    51/4 NPT1/4 NPTThreaded481.543 to 145Not RatedEN 175301-8039 1/4"7/8"2 5/8"Screw InYes0.17"24V DC2842N13000000
    51/4 NPT1/4 NPTThreaded481.543 to 145Not RatedEN 175301-8039 1/4"7/8"2 5/8"Screw InYes0.17"120V AC2842N14000000
    51/4 NPTF1/4 NPTFThreaded56115 to 15028 in. Hg8 5/8"7/8"2 3/4"Manifold, Screw In2No0.13"24V DC, 120V AC6425K16000000
    51/4 NPTF1/4 NPTFThreaded95.21.715 to 15028 in. Hg9 3/8"1"3"Manifold, Screw In4No0.18"24V DC, 120V AC6425K25000000
    53/8 NPT3/8 NPTThreaded792.543 to 145Not RatedEN 175301-80310 3/4"1 1/8"1 7/8"Screw InYes0.27"24V DC2842N15000000
    53/8 NPT3/8 NPTThreaded792.543 to 145Not RatedEN 175301-80310 3/4"1 1/8"1 7/8"Screw InYes0.27"120V AC2842N16000000
    53/8 NPTF3/8 NPTFThreaded95.21.715 to 15028 in. Hg9 3/8"1"3"Manifold, Screw In4No0.18"24V DC, 120V AC6425K26000000
     
    Accessories for Valves

    Two-Action Air Directional Control Valves with Exhausting Shut-Off

    Image of Product. Front orientation. Directional Control Valves. Two-Action Air Directional Control Valves with Exhausting Shut-Off .
    In the off position, these valves exhaust all air pressure, allowing equipment to return to the neutral position. Also known as 4-way and 4/3 exhaust-center valves, they create two actions, such as extracting and then retracting a double-acting cylinder. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by hand, so valves stay actuated and return to their original position only when you move the actuator again.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Hand Return
    41/4 NPT1/4 NPTThreaded1253.40 to 145Not Rated5 5/8"4"4 3/4"Screw InNo0.26"62365K62000000
    43/8 NPT3/8 NPTThreaded7030 to 150Not Rated6 7/8"4 3/4"3 3/4"Screw InNo0.34"62365K64000000
    41/2 NPT1/2 NPTThreaded1456.20 to 150Not Rated9"5 5/8"4 1/2"Screw InNo0.34"62365K66000000
     

    Toggle-Operated Block-Mount Hydraulic Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Toggle-Operated Block-Mount Hydraulic Directional Control Valves .
    Image of Specification. Style 1. Front orientation. Contains Annotated. Directional Control Valves. Toggle-Operated Block-Mount Hydraulic Directional Control Valves , 4-Way Valves—3 Flow Positions (4/3 Valves), Style 1.
    Image of Specification. Style 2. Front orientation. Contains Annotated. Directional Control Valves. Toggle-Operated Block-Mount Hydraulic Directional Control Valves , 4-Way Valves—3 Flow Positions (4/3 Valves), Style 2.
    Image of Specification. Style 3. Front orientation. Contains Annotated. Directional Control Valves. Toggle-Operated Block-Mount Hydraulic Directional Control Valves , 4-Way Valves—3 Flow Positions (4/3 Valves), Style 3.

    Style 1

    Style 2

    Style 3

    Image of Specification. Style 4. Front orientation. Contains Annotated. Directional Control Valves. Toggle-Operated Block-Mount Hydraulic Directional Control Valves , 4-Way Valves—3 Flow Positions (4/3 Valves), Style 4.
    Image of Specification. D03 Mounting Pattern. Bottom orientation. D03. Toggle-Operated Block-Mount Hydraulic Directional Control Valves .
    Image of Specification. D05 Mounting Pattern. Bottom orientation. D05. Toggle-Operated Block-Mount Hydraulic Directional Control Valves .

    Style 4

    D03 Mounting Pattern

    D05 Mounting Pattern

    Direct flow manually with a lever. A spring returns the valve to its default position once the lever is released. Often used before a double-acting cylinder. Use screws to attach to an NFPA valve-mounting block (each component sold separately).
    In NFPA diagrams, P represents the pressure source, T represents the tank, and A and B represent work ports.
    Valves
    Screws
    Overall
    Style
    NFPA Mounting
    Pattern
    ISO Mounting
    Pattern
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Lg.
    Wd.
    Ht.
    Each
    Pkg.
    Qty.
    Pkg.
    4-Way Valves—3 Flow Positions (4/3 Valves)
     
    Default Position Closed
    1D0303225,0005 7/8"1 7/8"6"4393T411000000041945N1200000
    1D0505405,0006 7/8"2 3/4"6 3/8"4393T4150000000041945N150000
     
    Default Position Open
    2D0303225,0005 7/8"1 7/8"6"4393T41200000041945N120000
     
    Default Position P Closed, A and B Open to T
    3D0303125,0005 7/8"1 7/8"6"4393T41300000041945N120000
    3D0505405,0006 7/8"2 3/4"6 3/8"4393T4170000000041945N150000
     
    Default Position P Open to T, A and B Closed
    4D0303125,0005 7/8"1 7/8"6"4393T41400000041945N120000
    4D0505135,0006 7/8"2 3/4"6 3/8"4393T4180000000041945N150000
     

    Two-Speed Two-Action Mechanically Operated Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Mechanically Operated Air Directional Control Valves, Style A.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Mechanically Operated Air Directional Control Valves, Style B.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Mechanically Operated Air Directional Control Valves, Style C.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Mechanically Operated Air Directional Control Valves, Style D.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Mechanically Operated Air Directional Control Valves, Style E.

    Style A

    Style B

    Style C

    Style D

    Style E

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Mechanically Operated Air Directional Control Valves, Style F.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Mechanically Operated Air Directional Control Valves, Style G.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Mechanically Operated Air Directional Control Valves, Style H.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Mechanically Operated Air Directional Control Valves, Style J.
    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Mechanically Operated Air Directional Control Valves, Style K.

    Style F

    Style G

    Style H

    Style J

    Style K

    Often used to extend and then retract a cylinder at different speeds, these valves create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. A simple automation solution that requires no programming, they activate when an object, such as a box rolling on a conveyor, pushes the actuator. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by spring, so they go back to their original position as soon the actuator is released. Also known as 4-way and 5/2 valves.
    1-Direction Actuation—Valves with a one-direction actuator are activated by objects from one side.
    2-Direction Actuation—Valves with a two-direction actuator are activated by objects from both sides.
    NPTF Inlet Thread—NPTF (Dryseal) threads are compatible with NPT threads.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    For Panel
    Cutout
    Style
    Actuation
    Force, lbf
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount Type
    Dia.
    Wd.
    Lg.
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    1-Direction Actuation—Spring Return
    C0.351/8 NPTF1/8 NPTFThreaded140.2425 to 125Not Rated2 1/8"3/4"3 3/8"Panel, Screw In1 1/2"1 1/4"No0.19"61345K510000000
     
    2-Direction Actuation—Spring Return
    A0.351/8 NPTF1/8 NPTFThreaded140.2425 to 125Not Rated2 1/4"3/4"2 5/8"Panel, Screw In1 1/2"1 1/4"No0.19"61345K71000000
    B0.351/8 NPTF1/8 NPTFThreaded140.2425 to 125Not Rated2 1/4"3/4"3"Panel, Screw In1 1/2"1 1/4"No0.19"61345K72000000
    D1151/4 NPTF1/4 NPTFThreaded531.60 to 15029 in. Hg2 1/4"3"7 1/4"Panel, Screw In1 3/8"2 1/4"No0.27"6859K56000000
    E0.851/8 NPTF1/8 NPTFThreaded140.2425 to 125Not Rated1 1/4"3/4"2 3/8"Panel, Screw In1/2"No0.19"6464K26000000
    F0.851/8 NPTF1/8 NPTFThreaded140.2425 to 125Not Rated1 1/4"3/4"3 1/8"Panel, Screw In1/2"No0.19"61345K74000000
    G1851/4 NPTF1/4 NPTFThreaded531.60 to 15029 in. Hg2 1/4"1 1/4"6 1/8"Panel, Screw In1 3/8"2 1/4"No0.27"6859K55000000
    H0.851/8 NPTF1/8 NPTFThreaded140.2425 to 125Not Rated1 1/4"3/4"3 1/2"Panel, Screw In1/2"No0.19"6464K27000000
    J1551/4 NPT1/4 NPTThreaded32.50.980 to 14526.5 in. Hg1 7/8"1 1/8"5 1/4"Panel, Screw In1 1/8"1 1/8"No0.26"8277K14000000
    K0.351/8 NPTF1/8 NPTFThreaded140.2425 to 125Not Rated6 1/4"3/4"3 7/8"Panel, Screw In3/4"1 1/4"No0.19"61345K14000000
     

    Two-Speed Two-Action Air-Operated Air Directional Control Valves with Full Shut-Off

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Air-Operated Air Directional Control Valves with Full Shut-Off .
    In the off position, these valves stop equipment in a locked position with air pressure holding it in place. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. They actuate by air signal, so they're good for environments where electrical use may be dangerous. Valves direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by air, so they go back to their starting position when the air supply is moved from the first air pilot to the second air pilot. Also known as 4-way and 5/3 closed center valves.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    Min. Actuation
    Pressure, psi
    No. of Flow
    Ports
    No. of Air
    Pilot Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Air Pilot
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Threaded Female Inlet x Threaded Female Outlet × Threaded Female Air Pilot
     
    Air Return
    44521/8 NPT1/8 NPTThreaded1/8 NPT420.526 to 145264 3/4"7/8"1 3/8"Screw InNo0.18"6124K4210000000
    44521/4 NPT1/4 NPTThreaded1/8 NPT730.9526 to 145265 5/8"1"1 5/8"Screw InNo0.18"6124K422000000
    Air Directional Control Valve with Full Shut-Off, Air-Operated, 1/4 NPT
    EachIn stock
     

    Multiple-Position Single-Action Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Multiple-Position Single-Action Air Directional Control Valves .
    Control six different outputs from a single source of airflow. These valves have one inlet port and six outlet ports. Push in and rotate the dial to move between outlet ports and send airflow to a different output. Also known as 3-way valves, they create one action, such as extending a cylinder. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by hand, so the chosen output remains actuated until you move the dial to another position. Air pressure exhausts to the atmosphere once a new position is selected.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount Type
    For Panel
    Cutout Dia.
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Hand Return
    710-32 UNF10-32 UNF7.50.090 to 125Not Rated1 1/2"1 1/2"2 3/4"Panel, Screw In5/8"Yes0.86"3020N110000000
     

    Electrically Operated Air Directional Control Valves with Flow Control

    Create motion and control the speed of that motion with a single valve. Also known as 4-way valves, these valves create two actions, such as extending and retracting a double-acting cylinder. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion, and adjust the volume of air exiting an air cylinder (meter out) to control speed. Apply voltage to the electrical connection to actuate.
    Push-to-Connect Male Inlet x Push-to-Connect Male Outlet
    Image of Product. Single Solenoid. Front orientation. Single Solenoid. Electrically Operated Air Directional Control Valves with Flow Control.
    Image of Product. Double Solenoid. Front orientation. Double Solenoid. Electrically Operated Air Directional Control Valves with Flow Control.

    Single Solenoid

    Double Solenoid

    5/3 (Closed Center) Flow Pattern—5/3 (closed center) valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place.
    5/3 (Pressure Center) Flow Pattern—5/3 (pressure center) valves create two actions at the same time, such as extending two single-acting cylinders at once.
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Valves
    Replacement
    Solenoids
    Inlet
    Outlet
    Overall
    No. of Flow
    Ports
    For Tube
    OD
    For Tube
    ID
    For Tube
    ID
    For Tube
    OD
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mounting Fasteners
    Included
    Choose a
    Voltage
    Each
    Each
    5/2 Flow Pattern
     
    Single Solenoid—Spring Return
    51/4"11/64"11/64"1/4"Threaded24.70.720 to 150Not Rated4 3/4"1 3/8"2 3/4"No24V DC4666A7100000004666A610000000
    51/4"11/64"11/64"1/4"Threaded24.70.720 to 150Not Rated4 3/4"1 3/8"2 3/4"No120V AC4666A720000004666A62000000
    53/8"1/4"1/4"3/8"Threaded24.70.720 to 150Not Rated4 3/4"1 3/8"2 3/4"No24V DC4666A210000004666A61000000
    53/8"1/4"1/4"3/8"Threaded24.70.720 to 150Not Rated4 3/4"1 3/8"2 3/4"No120V AC4666A220000004666A62000000
     
    Double Solenoid—Solenoid Return
    51/4"11/64"11/64"1/4"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A5000000———0
    53/8"1/4"1/4"3/8"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A1000000———0
     
    5/3 (Closed Center) Flow Pattern
     
    Double Solenoid—Solenoid Return
    51/4"11/64"11/64"1/4"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A8000000———0
    53/8"1/4"1/4"3/8"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A3000000———0
     
    5/3 (Pressure Center) Flow Pattern
     
    Double Solenoid—Solenoid Return
    51/4"11/64"11/64"1/4"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A9000000———0
    53/8"1/4"1/4"3/8"Threaded24.70.720 to 150Not Rated7 3/8"1 3/8"2 3/4"No24V DC, 120V AC4666A4000000———0
     

    Simultaneous Two-Action Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Simultaneous Two-Action Air Directional Control Valves.
    Also known as 4-way and 5/3 pressure center valves, these valves create two actions at the same time, such as extending two single-acting cylinders at once. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion.
    Spring Return—Valves with spring return actuation return to their original position as soon as you release the actuator.
    Hand Return—Valves with hand return actuation stay actuated and return to their original position only when you move the actuator again.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount Type
    For Panel
    Cutout Dia.
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Spring Return
    51/4 NPT1/4 NPTThreaded45.51.30 to 145Not Rated4 3/4"2 1/16"4 3/4"Panel, Screw In1"No0.26"3368K320000000
     
    Hand Return
    51/8 NPT1/8 NPTThreaded17.50.50 to 145Not Rated3 3/4"1 5/8"3 3/4"Panel, Screw In3/4"No0.22"3368K17000000
    51/4 NPT1/4 NPTThreaded45.51.30 to 145Not Rated4 3/4"2 1/16"4 3/4"Panel, Screw In1"No0.26"3368K28000000
     

    Dual-Input Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Dual-Input Air Directional Control Valves.
    Air pressure must be supplied to both inlets before the output port will open, allowing airflow to your equipment. When the two input flows have different pressure levels, the output airflow will always be the lower of the two input pressures. Also known as "and" valves.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Threaded Female Inlet x Threaded Female Outlet
    31/8 BSPP1/8 BSPP7.340.1315 to 145Not Rated1 9/16"5/8"1 1/4"Screw InNo0.18"3084N131000000
     

    Inline Hydraulic Directional-Control Valves

    Image of Product. Front orientation. Directional Control Valves. Inline Hydraulic Directional-Control Valves.
    Image of Specification. Front orientation. Contains Annotated. Directional Control Valves. Inline Hydraulic Directional-Control Valves.
    Image of Specification. Hydraulic Symbol. Front orientation. Directional Control Valves. Inline Hydraulic Directional-Control Valves.

    Hydraulic

    Symbol

    Turn the handle to direct flow between ports. All valves are standard port, so they slightly restrict flow.
    In NFPA diagrams, P represents the pressure source, T represents the tank, and A represents the work port.
    Pressure
    Connection—NPT
    Overall
    Pipe
    Size
    Dash
    Size
    Max. Flow
    Rate
    Max. Pressure,
    psi
    Seal Material
    Lg.
    Wd.
    Ht.
    Port-to-Port
    Lg.
    Mounting
    Hole Dia.
    Temp. Range,
    ° F
    Valve
    Type
    Each
    3-Way Valves—2 Flow Positions (3/2 Valves)
     
    Steel Body with Chrome-Plated Steel Ball
    1/4
    04Not Rated7,200Acetal, Fluoroelastomer
    8 3/8"3 5/8"3 3/8"3 15/16"9/32"15 to 175Ball46185K5110000000
    3/8
    06Not Rated7,200Acetal, Fluoroelastomer
    9 7/16"4 1/16"4"4 9/16"9/32"15 to 175Ball46185K512000000
    1/2
    08Not Rated5,800Acetal, Fluoroelastomer
    8 11/16"6 5/16"5 3/32"6 5/16"11/32"0 to 212Ball46185K513000000
    3/4
    12Not Rated4,500Acetal, Fluoroelastomer
    11 3/4"5 1/8"5 1/4"5 11/16"11/32"15 to 175Ball46185K514000000
     

    Screw-In Hydraulic Directional-Control Valves

    Control the direction of flow or stop flow altogether with an electronic signal. These valves are also known as cartridge valves, and they screw into your mounting block.
    In NFPA diagrams, P represents the pressure source, T represents the tank, and A and B represent work ports.
    Single-Solenoid 3-Way Valves—2 Flow Positions (3/2 Valves)
    Image of Product. Front orientation. Directional Control Valves. Screw-In Hydraulic Directional-Control Valves, 3 Way, 2 Flow Positions.
    Image of Specification. Front orientation. Contains Annotated. Directional Control Valves. Screw-In Hydraulic Directional-Control Valves, 3 Way, 2 Flow Positions, Style 1.

    Style 1

    Place three-way valves between the pressure source and a single-acting cylinder.
    Valves
    Replacement
    Solenoid Coils
    Body—UN/UNF
    (SAE Straight)
    Deltrol Equivalent
    Model No.
    Hydraforce Equivalent
    Model No.
    Parker Equivalent
    Model No.
    Thread
    Size
    Dash
    Size
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Voltage,
    V DC
    Overall
    Ht.
    Each
    Each
    Style 1—Default Position P Closed, A Open to T
    DSV2-080-3B-N-D1DESV08-30-0-N-12ELDSL083-B-N-SP-D012-L3/4"-16
    0853,000123 9/16"1643N340000001678N11000000
    DSV2-080-3B-N-D2DESV08-30-0-N-24ELDSL083-B-N-SP-D024-L3/4"-16
    0853,000243 9/16"1643N35000001678N1200000
     
    Single-Solenoid 4-Way Valves—2 Flow Positions (4/2 Valves)
    Image of Product. Front orientation. Directional Control Valves. Screw-In Hydraulic Directional-Control Valves, 4 Way, 2 Flow Positions.
    Image of Specification. Front orientation. Contains Annotated. Directional Control Valves. Screw-In Hydraulic Directional-Control Valves, 4 Way, 2 Flow Positions, Style 2.

    Style 2

    Image of Specification. Front orientation. Contains Annotated. Directional Control Valves. Screw-In Hydraulic Directional-Control Valves, 4 Way, 2 Flow Positions, Style 3.

    Style 3

    Place four-way valves between the pressure source and a double-acting cylinder.
    Valves
    Replacement
    Solenoid Coils
    Body—UN/UNF
    (SAE Straight)
    Deltrol Equivalent
    Model No.
    Hydraforce Equivalent
    Model No.
    Parker Equivalent
    Model No.
    Thread
    Size
    Dash
    Size
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Voltage,
    V DC
    Overall
    Ht.
    Each
    Each
    Style 2—Default Position Closed
    DSV2-080-4NC-N-D2DESV08-41-0-N-24ELDSL084-N-N-DP-D024-L3/4"-16
    0833,000244 1/16"1643N460000001678N12000000
     
    Style 3—Default Position P Open to A, B Open to T
    DSV2-100-4CO-N-D1DSV10-40-0-N-12DLDSL104-B-N-D012-L7/8"-14
    1063,000124 7/8"1643N430000001678N1300000
     
    Double-Solenoid 4 Way Valves—3 Flow Positions (4/3 Valves)
    Image of Product. Front orientation. Directional Control Valves. Screw-In Hydraulic Directional-Control Valves, 4 Way, 3 Flow Positions.
    Image of Specification. Front orientation. Contains Annotated. Directional Control Valves. Screw-In Hydraulic Directional-Control Valves, 4 Way, 3 Flow Positions, Style 4.

    Style 4

    Image of Specification. Front orientation. Contains Annotated. Directional Control Valves. Screw-In Hydraulic Directional-Control Valves, 4 Way, 3 Flow Positions, Style 5.

    Style 5

    Place four-way valves between the pressure source and a double-acting cylinder.
    Valves
    Replacement
    Solenoid Coils
    Body—UN/UNF
    (SAE Straight)
    Deltrol Equivalent
    Model No.
    Hydraforce Equivalent
    Model No.
    Thread
    Size
    Dash
    Size
    Max. Flow
    Rate, gpm
    Max. Pressure,
    psi
    Voltage,
    V DC
    Overall
    Ht.
    Each
    Each
    Style 4—Default Position Closed
    DSV-080-34C-N-D1DESV08-47C-0-N-12EL3/4"-16
    0833,000125 1/2"1643N6200000001678N11000000
     
    Style 5—Default Position P Open to T, A and B Closed
    DSV-080-34T-N-D1DESV08-47A-0-N-12EL3/4"-16
    0833,000125 1/2"1643N780000001678N1100000
    DSV-080-34T-N-D2DESV08-47A-0-N-24EL3/4"-16
    0833,000245 1/2"1643N790000001678N1200000
     

    Wear-Resistant Electrically Operated Air Directional Control Valves

    Ceramic plates form a longer-lasting seal against oil and dust than rubber seals that deteriorate over time. These valves withstand use in corrosive, dusty, and dirty environments such as foundries, paper mills, and steel plants. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Apply voltage to the electrical connection to actuate. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Also known as 4-way valves.
    Threaded Female Inlet x Threaded Female Outlet
    Image of Product. Single Solenoid. Front orientation. Single Solenoid. Wear-Resistant Electrically Operated Air Directional Control Valves.
    Image of Product. Double Solenoid. Front orientation. Double Solenoid. Wear-Resistant Electrically Operated Air Directional Control Valves.

    Single Solenoid

    Double Solenoid

    5/3 (Closed Center) Flow Pattern—5/3 (closed center) valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place.
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Voltage
    Lg.
    Wd.
    Ht.
    Mounting Fasteners
    Included
    Each
    5/2 Flow Pattern
     
    Single Solenoid—Spring Return
    51/4 NPT1/4 NPTThreaded401.129 to 1502424V DC6 3/8"1 7/8"5 3/4"Yes4117N220000000
    51/4 NPT1/4 NPTThreaded401.129 to 15024120V AC6 3/8"1 7/8"5 3/4"Yes4117N19000000
    53/8 NPT3/8 NPTThreaded401.129 to 15024120V AC6 3/8"1 7/8"6"Yes4117N21000000
     
    Double Solenoid—Solenoid Return
    51/4 NPT1/4 NPTThreaded401.129 to 1502424V DC7"1 7/8"5 3/4"Yes4117N17000000
    51/4 NPT1/4 NPTThreaded401.129 to 15024120V AC7"1 7/8"5 3/4"Yes4117N15000000
    53/8 NPT3/8 NPTThreaded401.129 to 1502424V DC7"1 7/8"6"Yes4117N18000000
    53/8 NPT3/8 NPTThreaded401.129 to 15024120V AC7"1 7/8"6"Yes4117N16000000
     
    5/3 (Closed Center) Flow Pattern
     
    Double Solenoid—Solenoid Return
    51/4 NPT1/4 NPTThreaded401.144 to 1502424V DC7"1 7/8"5 3/4"Yes4117N13000000
    51/4 NPT1/4 NPTThreaded401.144 to 15024120V AC7"1 7/8"6"Yes4117N11000000
    53/8 NPT3/8 NPTThreaded401.144 to 1502424V DC7"1 7/8"6"Yes4117N14000000
    53/8 NPT3/8 NPTThreaded401.144 to 15024120V AC7"1 7/8"6"Yes4117N12000000
     

    Single-Action Electrically Operated Air Directional Control Valves with Full Shut-Off

    Image of Product. Front orientation. Directional Control Valves. Single-Action Electrically Operated Air Directional Control Valves with Full Shut-Off .
    Also known as 3-way and 3/3 valves, these valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place. They create one action, such as extending a cylinder. Apply voltage to the electrical connection to actuate. Valves direct airflow from the inlet to your equipment and exhaust return airflow to create motion. They're normally closed to block airflow until actuated. Return actuation is by spring, so they go back to their starting position as soon as voltage is removed.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Voltage
    Specs. Met
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Double Solenoid—Spring Return
    31/8 NPT1/8 NPTThreaded27.360.5929 to 1022624V DCEN 175301-8032 1/2"1 1/8"4 3/8"Screw InYes0.11"2850N110000000
    31/8 NPT1/8 NPTThreaded27.40.5929 to 10226120V ACEN 175301-8032 1/2"1 1/8"4 3/8"Screw InYes0.11"2850N12000000
    31/4 NPT1/4 NPTThreaded41.270.8929 to 1022624V DCEN 175301-8032 1/2"1 1/8"4 3/8"Screw InYes0.11"2850N14000000
    31/4 NPT1/4 NPTThreaded41.270.8929 to 10226120V ACEN 175301-8032 1/2"1 1/8"4 3/8"Screw InYes0.11"2850N13000000
    33/8 NPT3/8 NPTThreaded1242.229 to 1022624V DCEN 175301-8033 1/8"1 3/8"5 3/8"Screw InYes0.22"2850N15000000
    33/8 NPT3/8 NPTThreaded1242.229 to 10226120V ACEN 175301-8033 1/8"1 3/8"5 3/8"Screw InYes0.22"2850N16000000
     

    Key-Operated Two-Speed Two-Action Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Key-Operated Two-Speed Two-Action Air Directional Control Valves.
    Because they require a key to operate, you can limit who is able to adjust these valves. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by hand, so they stay actuated and return to their original position only when you move the actuator again. Also known as 4-way and 5/2 valves.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Lg.
    Wd.
    Ht.
    Mount Type
    For Panel
    Cutout Dia.
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    No. of Keys
    Included
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Hand Return
    51/8 NPT1/8 NPTThreaded11.30.3414 to 14526.57/8"1 5/8"5 5/8"Panel, Screw In1 1/4"No0.21"28444K340000000
     

    Two-Speed Two-Action Foot-Operated Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Two-Speed Two-Action Foot-Operated Air Directional Control Valves.
    Often used to extend and then retract a cylinder at different speeds, these valves create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Operate them with your foot, leaving your hands free to perform other tasks. Valves direct airflow from the inlet to your equipment and exhaust return airflow to create motion. The foot guard prevents accidental valve operation. Also known as 4-way and 5/2 valves.
    Spring Return—Valves with spring return actuation return to their original position as soon as you release the actuator.
    Foot Pedal Return—Valves with a foot pedal return actuation stay actuated and return to their original position only when you step on them again.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow
    Rate @ 100 psi
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Spring Return
    51/4 NPT1/4 NPTThreadedNot Rated0.780 to 116Not Rated9 5/8"5 3/8"5 1/4"Screw InNo0.24"3088T41000000
    51/4 BSPP1/4 BSPPThreaded30 scfm1.360 to 145Not Rated236 mm169 mm157 mmScrew InNo0.25"3088T5000000
     
    Foot Pedal Return
    51/4 BSPP1/4 BSPPThreaded30 scfm1.360 to 145Not Rated236 mm169 mm157 mmScrew InNo0.25"3088T6000000
     

    Quick Switch Single-Action Electrically Operated Air Directional Control Valves

    Run through equipment cycles up to 30% faster than with standard valves. They create one action, such as extending a cylinder. Apply voltage to the electrical connection to actuate. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by spring, so they go back to their starting position as soon as voltage is removed. Also known as 3-way and 3/2 valves.
    Threaded Female Inlet × Threaded Female Outlet—Threaded Exhaust
    Image of Product. Front orientation. Directional Control Valves. Quick Switch Single-Action Electrically Operated Air Directional Control Valves .
    Fail Open—Fail-open valves allow airflow until actuated.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Valves
    Brackets
    Overall,
    mm
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Voltage,
    V DC
    Lg.
    Wd.
    Ht.
    Mounting Fasteners
    Included
    Enclosure
    Rating
    Certification
    Each
    Each
    Fail Open
    31/8 BSPP1/8 BSPP11.4690.203-13 to 11626.524341073NoIP65
    CE Marked, UL Recognized Component, C-UL Recognized Component
    4077N1400000004107N1100000
     
    Push-to-Connect Female Inlet × Push-to-Connect Female Outlet—Push-to-Connect Exhaust
    Image of Product. Front orientation. Directional Control Valves. Quick Switch Single-Action Electrically Operated Air Directional Control Valves .
    Fail Open—Fail-open valves allow airflow until actuated.
    Fail Closed—Fail-closed valves block airflow until actuated.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Mufflers—Mufflers (sold separately) reduce exhaust noise.
    Valves
    Mufflers
    Brackets
    Overall,
    mm
    No. of Flow
    Ports
    For Inlet
    Tube OD, mm
    For Outlet
    Tube OD, mm
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Voltage,
    V DC
    Lg.
    Wd.
    Ht.
    Mounting Fasteners
    Included
    Enclosure
    Rating
    Certification
    Each
    Each
    Each
    Fail Open
    3445.7630.102-13 to 11626.524731034NoIP65
    CE Marked, UL Recognized Component, C-UL Recognized Component
    4077N1100000004097N110000004107N1100000
    38822.9940.407-13 to 11626.524114.61852NoIP65
    CE Marked, UL Recognized Component, C-UL Recognized Component
    4077N160000004097N13000004107N110000
     
    Fail Closed
    3445.7630.102-13 to 11626.524731034NoIP65
    CE Marked, UL Recognized Component, C-UL Recognized Component
    4077N120000004097N11000004107N110000
    36611.4690.203-13 to 11626.52494.51445NoIP65
    CE Marked, UL Recognized Component, C-UL Recognized Component
    4077N130000004097N12000004107N110000
    38822.9940.407-13 to 11626.524114.61856NoIP65
    CE Marked, UL Recognized Component, C-UL Recognized Component
    4077N150000004097N13000004107N110000
     

    Two-Action Foot-Operated Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Two-Action Foot-Operated Air Directional Control Valves , Style A.
    Image of Product. Front orientation. Directional Control Valves. Two-Action Foot-Operated Air Directional Control Valves , Style B.

    Style A

    Style B

    Image of Product. Front orientation. Directional Control Valves. Two-Action Foot-Operated Air Directional Control Valves , Style C.

    Style C

    Also known as 4-way and 4/2 valves, these valves create two actions, such as extending and then retracting a cylinder. Use your foot to operate them, leaving your hands free to perform other tasks. Valves direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Valves without an exhaust connection exhaust air to the atmosphere.
    Spring Return—Valves with spring return actuation return to their original position as soon as you release the actuator.
    Foot Pedal Return—Valves with a foot pedal return actuation stay actuated and return to their original position only when you step on them again.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Switch Guards—Switch guards (sold separately) prevent accidental valve actuation.
    Valves
    Switch Guards
    Replacement
    O-Ring Kits
    Overall
    Style
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Each
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Spring Return
    A41/8 NPT1/8 NPT300.5360 to 150Not Rated4 1/2"3 1/2"1 3/4"Screw InNo0.22"9781K3100000007024K5000000———0
    B41/4 NPTF1/4 NPTFThreaded832.40 to 22529 in. Hg11 1/2"3 1/2"2 3/4"Screw InNo0.34"6654K11000000———06654K111000000
    B43/8 NPTF3/8 NPTFThreaded1183.20 to 22529 in. Hg12 1/2"3 1/2"2 3/4"Screw InNo0.34"6654K12000000———06654K12100000
    B41/2 NPTF1/2 NPTFThreaded1855.20 to 21529 in. Hg14 1/2"3 1/2"3 3/8"Screw InNo0.41"6654K13000000———0———0
     
    Foot Pedal Return
    C41/4 NPTF1/4 NPTFThreaded832.40 to 22529 in. Hg9 1/2"3 1/4"4 1/2"Screw InNo0.34"6654K21000000———06654K21100000
    C41/2 NPTF1/2 NPTFThreaded1855.20 to 21529 in. Hg12 1/8"3 1/4"4 7/8"Screw InNo0.41"6654K23000000———06654K13100000
     

    Two-Hand Single-Action Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Two-Hand Single-Action Air Directional Control Valves .
    Since both hands are required to simultaneously press the buttons, these valves protect workers from accidental machinery start-up. Also known as 2-hand control valves, they create one action, such as extending a cylinder. Valves direct airflow from the inlet to your equipment and exhaust return airflow to create motion. They can be installed fail open to allow airflow until actuated, or installed to block airflow until actuated. Return actuation is by spring, so valves return to their starting position as soon as you release the actuator. These valves actuate any 3 or 4-way air piloted spring return power valve or small single-acting cylinders. In the off position, they exhaust air pressure from the system to the atmosphere, allowing equipment to reset so the action can be repeated.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    Actuation
    Force, ozf
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Spring Return
    621/8 NPT1/8 NPT60.1170 to 100Not Rated10 1/2"3 1/2"3 3/16"Screw InNo0.28"62115K22000000000
    1821/8 NPT1/8 NPT60.1170 to 100Not Rated10 1/2"3 1/2"3 3/16"Screw InNo0.28"62115K2100000000
     

    Safety-Lockout Single-Action Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Safety-Lockout Single-Action Air Directional Control Valves.
    To prevent accidental start-up, these valves can be locked in their off position with a padlock. Also known as 3-way and 3/2 valves, they create one action, such as extending a cylinder. Valves direct airflow from the inlet to your equipment and exhaust return airflow to create motion. They're fail closed to block airflow until actuated. Return actuation is by hand, so they stay actuated and return to their starting position only when you move the actuator again. In the off position, they exhaust air pressure from the system, allowing equipment to reset so the action can be repeated. They help meet OSHA 29 CFR 1910.147 procedures for the control of energy sources that could injure workers.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Specs. Met
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Mounting Fasteners
    Included
    Padlock
    Included
    For Max. Padlock
    Shackle Dia.
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Hand Return
    31/8 NPT1/8 NPTThreaded661.115 to 145Not RatedOSHA Compliant 29 CFR 1910.147
    2 3/8"2"3 1/2"Screw InNoNo25/64"63015K41000000
    31/4 NPT1/4 NPTThreaded1682.815 to 145Not RatedOSHA Compliant 29 CFR 1910.147
    3 1/2"3 3/8"5 3/8"Screw InNoNo25/64"63015K4400000
    33/8 NPT3/8 NPTThreaded2884.815 to 145Not RatedOSHA Compliant 29 CFR 1910.147
    3 1/2"3 3/8"5 3/8"Screw InNoNo25/64"63015K45100000
    31/2 NPT1/2 NPTThreaded3796.315 to 145Not RatedOSHA Compliant 29 CFR 1910.147
    3 1/2"3 3/8"5 3/8"Screw InNoNo25/64"63015K4600000
    33/4 NPT3/4 NPTThreaded63710.615 to 145Not RatedOSHA Compliant 29 CFR 1910.147
    4 1/2"4 1/2"6 1/4"Screw InNoNo25/64"63015K4700000
    31 NPT1 NPTThreaded81213.515 to 145Not RatedOSHA Compliant 29 CFR 1910.147
    4 1/2"4 1/2"6 1/4"Screw InNoNo25/64"63015K4800000
     

    Quick Switch Two-Speed Two-Action Electrically Operated Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Quick Switch Two-Speed Two-Action Electrically Operated Air Directional Control Valves.
    Run through equipment cycles up to 30% faster than with standard valves. These valves shift between flow positions in 1.7 ms. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. Also known as 4-way and 5/2 valves, they actuate when voltage is applied to the electrical connection. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by spring, so they go back to their starting position as soon as voltage is removed.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Valves
    Mufflers
    Brackets
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Voltage,
    V DC
    Wire
    Connection
    Lg.
    Wd.
    Ht.
    Enclosure
    Rating
    Specs. Met
    Certification
    Each
    Each
    Each
    Threaded Female Inlet × Threaded Female Outlet—Threaded Exhaust
    51/4 NPT1/4 NPT19.220.54440 to 100Not Rated243 7/8"3/4"1 1/2"IP65
    EN 175301-8032974N110000000———0———0
    5M7 × 1 mmM7 × 1 mm5.1410.091-13 to 11626.5 in. Hg24Wire Leads84 mm10 mm34 mmIP65
    CE Marked, UL Recognized Component, C-UL Recognized Component
    4087N110000004097N110000004107N1100000
     

    Key-Operated Single-Action Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Key-Operated Single-Action Air Directional Control Valves.
    Because they require a key to operate, you can limit who is able to adjust these valves. Also known as 3-way and 3/2 valves, they create one action, such as extending a cylinder. Valves direct airflow from the inlet to your equipment and exhaust return airflow to create motion. They're fail closed to block airflow until actuated. Return actuation is by hand, so they stay actuated and return to their starting position only when you move the actuator again. In the off position, they exhaust air pressure from the system to the atmosphere, allowing equipment to reset so the action can be repeated.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Vacuum Rating,
    in. Hg
    Lg.
    Wd.
    Ht.
    Mount Type
    For Panel
    Cutout Dia.
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    No. of Keys
    Included
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Hand Return
    31/4 NPT1/4 NPT33.531.050 to 14529.51 5/8"1 5/8"4 1/8"Panel, Screw In1 1/8"No0.22"28444K2000000
     

    Two-Hand Two-Action Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Two-Hand Two-Action Air Directional Control Valves.
    Since both hands are required to simultaneously press the buttons, these valves protect workers from accidental machinery start-up. Also known as 4-way and 4/2 valves, they create two actions, such as extending and then retracting a double-acting cylinder. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by spring, so valves return to their original position as soon as you release the actuator.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    Actuation
    Force, ozf
    No. of Flow
    Ports
    Inlet
    Size
    For Inlet
    Tube OD
    Outlet
    Size
    For Outlet
    Tube OD
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Spring Return
    641/4 NPTF1/4"1/4 NPTF1/4"Threaded56170 to 100Not Rated10 1/2"3 1/2"3 3/16"Screw InNo0.28"62115K24000000000
    1841/4 NPTF1/4"1/4 NPTF1/4"Threaded56170 to 100Not Rated10 1/2"3 1/2"3 3/16"Screw InNo0.28"62115K2300000000
     

    Remote-Access Two-Hand Single-Action Air Directional Control Valves

    Image of Product. Front orientation. Contains Annotated, Border. Directional Control Valves. Remote-Access Two-Hand Single-Action Air Directional Control Valves.
    The push buttons that operate these valves are separate from the logic unit, allowing you to position them away from machinery. Since both hands are required to simultaneously press the buttons, they protect workers from accidental machinery start-up. Also known as 3-way and 3/2 valves, they create one action, such as extending a cylinder. Valves direct airflow from the inlet to your equipment and exhaust return airflow to create motion. They're fail closed to block airflow until actuated. Return actuation is by spring, so valves return to their starting position as soon as you release the actuator. In the off position, they exhaust air from the system, allowing equipment to reset so the action can be repeated.
    Note: Valve is sold as a complete unit, consisting of one logic unit and two signal valves. Port size given is for the logic unit. Signal valve port size is 1/8 NPT female.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of Flow
    Ports
    For Inlet
    Tube OD
    For Outlet
    Tube OD
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount Type
    For Panel
    Cutout Dia.
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Push-to-Connect Female Inlet x Push-to-Connect Female Outlet
     
    Spring Return
    31/4"1/4"Push to Connect3.80.1136 to 145Not Rated2 1/2"1 3/4"2 3/4"Panel, Screw In1 1/8"No0.2"6282K550000000
     
    Replacements for Valves

    Single-Action Foot-Operated Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Single-Action Foot-Operated Air Directional Control Valves, 1 Valve.
    Image of Product. Front orientation. Directional Control Valves. Single-Action Foot-Operated Air Directional Control Valves, 2 Valves.

    1 Valve

    2 Valves

    Also known as 3-way or 3/2 valves, these valves create one action, such as extending a cylinder. Use your foot to operate them, leaving your hands free to perform other tasks. Valves direct airflow from the inlet to your equipment and exhaust return airflow to create motion. They're fail closed to normally block airflow, and remain closed until actuated. Return actuation is by spring, so they go back to their original position as soon as you release the actuator. In the off position, they exhaust air pressure from the system to the atmosphere, allowing equipment to reset so the action can be repeated.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Valves
    Switch Guards
    Overall
    No. of
    Valves
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mount
    Type
    Mounting Fasteners
    Included
    Mounting
    Hole Dia.
    Each
    Each
    Threaded Female Inlet x Threaded Female Outlet
     
    Spring Return
    131/8 NPT1/8 NPT300.5360 to 150Not Rated2 7/8"2 1/2"1 3/8"Screw InNo0.1"9781K1200000007024K5000000
    131/8 NPT1/8 NPT300.5360 to 150Not Rated4 1/2"3 1/2"1 3/4"Screw InNo0.22"9781K130000007024K500000
    231/8 NPT1/8 NPT300.5360 to 150Not Rated2 7/8"5 3/4"1 1/2"Screw InNo0.16"9781K220000007024K1700000
    231/8 NPT1/8 NPT300.5360 to 150Not Rated4 1/2"8 3/8"1 7/8"Screw InNo0.22"9781K230000007024K1700000
     

    Simultaneous Two-Action Electrically Operated Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Simultaneous Two-Action Electrically Operated Air Directional Control Valves.
    Also known as pressure-center valves and 4-way valves, these valves create two actions at the same time, such as extending two single-acting cylinders at once. Apply voltage to the electrical connection to actuate. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is electric (solenoid), so they go back to their original position when voltage moves from the first solenoid to the second solenoid.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Exhaust
    Connection
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum
    Rating
    Voltage
    Lg.
    Wd.
    Ht.
    Mounting Fasteners
    Included
    Each
    5/3 (Pressure Center) Flow Pattern
     
    Threaded Female Inlet x Threaded Female Outlet
    51/8 NPT1/8 NPTThreaded190.643 to 145Not Rated24V DC8 3/4"7/8"2 5/8"Yes2945N210000000
    51/8 NPT1/8 NPTThreaded190.643 to 145Not Rated120V AC8 3/4"7/8"2 5/8"Yes2945N22000000
    51/4 NPT1/4 NPTThreaded481.543 to 145Not Rated24V DC9 1/4"7/8"2 5/8"Yes2945N23000000
    51/4 NPT1/4 NPTThreaded481.543 to 145Not Rated120V AC9 1/4"7/8"2 5/8"Yes2945N24000000
    53/8 NPT3/8 NPTThreaded792.543 to 145Not Rated24V DC10 3/4"1 1/8"2 3/4"Yes2945N25000000
    53/8 NPT3/8 NPTThreaded792.543 to 145Not Rated120V AC10 3/4"1 1/8"2 3/4"Yes2945N26000000
     

    Hazardous Location Electrically Operated Air Directional Control Valves

    These valves are rated for environments where hazardous material is present. Often used to extend and then retract a cylinder at different speeds, they create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Apply voltage to the electrical connection to actuate. Return actuation is by spring, so they go back to their original position when voltage is removed. Also known as 4-way valves.
    Threaded Female Inlet × Threaded Female Outlet—Threaded Exhaust
    Image of Product. Single Solenoid. Front orientation. Single Solenoid. Hazardous Location Electrically Operated Air Directional Control Valves.
    Image of Product. Double Solenoid. Front orientation. Double Solenoid. Hazardous Location Electrically Operated Air Directional Control Valves.

    Single Solenoid

    Double Solenoid

    5/3 (Closed Center) Flow Pattern—5/3 (closed center) valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Hazardous Location Rating—Hazardous location ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
    Overall
    No. of Flow
    Ports
    Inlet
    Size
    Outlet
    Size
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Hazardous Location Rating
    Enclosure Rating
    Voltage
    Wire
    Connection
    Lg.
    Wd.
    Ht.
    Mounting Fasteners
    Included
    Each
    5/2 Flow Pattern
     
    Single Solenoid
    51/4 NPT1/4 NPT65.341.714 to 14528NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 3S
    NEMA 6P
    NEMA 7
    NEMA 9
    24V DCWire Leads6"1"2 7/8"No2992N110000000
    51/4 NPT1/4 NPT65.341.714 to 14528NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 3S
    NEMA 6P
    NEMA 7
    NEMA 9
    120V ACWire Leads6"1"2 7/8"No2992N12000000
     
    5/3 (Closed Center) Flow Pattern
     
    Double Solenoid
    51/4 NPT1/4 NPT65.341.714 to 14528NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 3S
    NEMA 6P
    NEMA 7
    NEMA 9
    24V DCWire Leads9 3/8"1"2 7/8"No2992N13000000
    51/4 NPT1/4 NPT65.341.714 to 14528NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    NEMA 3S
    NEMA 6P
    NEMA 7
    NEMA 9
    120V ACWire Leads9 3/8"1"2 7/8"No2992N14000000
     
    Accessories for Valves

    High-Pressure Washdown Electrically Operated Air Directional Control Valves

    IP69K, these valves withstand high-pressure, high-temperature washdowns. Their smooth design also keeps out dust, dirt, and contaminants, so they're easy to keep clean. Apply voltage to the electrical connection to actuate. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion.
    Threaded Female Inlet × Threaded Female Outlet—Threaded Exhaust
    Image of Product. Front orientation. Directional Control Valves. High-Pressure Washdown Electrically Operated Air Directional Control Valves .
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    3 Way—3-way valves create one action, such as extending a cylinder.
    4 Way—4-way valves create two actions, such as extending and then retracting a double-acting cylinder.
    5/3 (Closed Center) Flow Pattern—5/3 (closed center) valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place.
    2 Exhaust Ports—Valves with two exhaust ports allow you to independently control the speed of two different actions. Connect a flow control valve to each exhaust port.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall,
    mm
    Air Directional
    Control Valve Type
    Air Directional Control
    Valve Flow Pattern
    No. of Flow
    Ports
    No. of Exhaust
    Ports
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Voltage,
    V DC
    Lg.
    Wd.
    Ht.
    Each
    Single Solenoid—Spring Return
    3 Way3/23125.110.711-13 to 14526.524190.534.968.582963N120000000
    4 Way5/25225.110.711-13 to 14526.524190.534.968.582963N13000000
    4 Way5/3 (Closed Center)5225.110.711-13 to 14526.524190.534.968.582963N17000000
     
    Double Solenoid—Solenoid Return
    4 Way5/25225.110.711-13 to 14526.524190.534.968.582963N15000000
     
    Push-to-Connect Female Inlet × Push-to-Connect Female Outlet—Push-to-Connect Exhaust
    Image of Product. Front orientation. Directional Control Valves. High-Pressure Washdown Electrically Operated Air Directional Control Valves .
    Spring Return—Valves with spring return actuation go back to their original position when voltage is removed.
    Solenoid Return—Valves with solenoid return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
    3 Way—3-way valves create one action, such as extending a cylinder.
    4 Way—4-way valves create two actions, such as extending and then retracting a double-acting cylinder.
    5/3 (Closed Center) Flow Pattern—5/3 (closed center) valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place.
    2 Exhaust Ports—Valves with two exhaust ports allow you to independently control the speed of two different actions. Connect a flow control valve to each exhaust port.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall,
    mm
    Air Directional
    Control Valve Type
    Air Directional Control
    Valve Flow Pattern
    No. of Flow
    Ports
    No. of Exhaust
    Ports
    For Inlet
    Tube OD, mm
    For Outlet
    Tube OD, mm
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure Range,
    psi
    Vacuum Rating,
    in. Hg
    Voltage,
    V DC
    Lg.
    Wd.
    Ht.
    Each
    Single Solenoid—Spring Return
    3 Way3/2318825.110.711-13 to 14526.524190.534.976.22963N110000000
    4 Way5/2528825.110.711-13 to 14526.524190.534.976.22963N14000000
    4 Way5/3 (Closed Center)528825.110.711-13 to 14526.524190.534.976.22963N18000000
     
    Double Solenoid—Solenoid Return
    4 Way5/2528825.110.711-13 to 14526.524190.534.976.22963N16000000
     

    Input-Selecting Air Directional Control Valves

    Image of Product. Front orientation. Directional Control Valves. Input-Selecting Air Directional Control Valves .
    Also known as shuttle valves and "or" valves, these valves select between the higher of two inlet pressures to power one outlet port. They're often used in emergency systems where the lower pressure input acts as a backup to the higher pressure input.
    Flow Coefficient (Cv)—Flow coefficient (Cv) indicates how much airflow can pass through a valve.
    Overall
    No. of Flow
    Ports
    For Inlet
    Tube OD
    For Outlet
    Tube OD
    Max. Flow Rate
    @ 100 psi, scfm
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Vacuum
    Rating
    Lg.
    Wd.
    Ht.
    Mounting
    Location
    Each
    Push-to-Connect Female Inlet x Push-to-Connect Female Outlet
    35/32"5/32"27.120.480 to 125Not Rated1 5/8"5/8"1 1/8"Inline3084N11000000
    31/4"1/4"27.120.480 to 125Not Rated1 15/16"5/8"1 1/4"Inline3084N1200000
     

    Robot-Arm-Mounted Electrically Operated Air Directional Control Valves

    Image of System. Front orientation. Contains Annotated. Directional Control Valves. Robot-Arm-Mounted Electrically Operated Air Directional Control Valves.
    Image of Product. Front orientation. Directional Control Valves. Robot-Arm-Mounted Electrically Operated Air Directional Control Valves.
    Control air-powered robot tools, such as pick-and-place grippers. These valves have two three-way valves, also known as 3/2 valves, that you can control separately with your robot’s program. For example, you can connect two single-acting tools, such as two grippers with spring jaw returns, using one valve for each. Alternatively, use both valves for one double-acting tool, such as an air cylinder—one valve pushes the cylinder out, the other pulls it back. In both setups, air escapes through vents on the side of the manifold.
    These valves come with everything you need for quick installation. Use the hook and loop straps to mount them to your robot arm, then plug the electrical cord into the M8 connection at the end of the arm. Connect your compressed air line to the inlet. Last, run tubing from the valve to your robot tool.
    Inlet
    Outlet
    No. of Flow
    Ports
    Connection
    For Tube
    OD, mm
    Connection
    For Tube
    OD, mm
    Max. Flow Rate
    @ Pressure
    Flow Coefficient
    (Cv)
    Pressure
    Range, psi
    Each
    3Push to Connect6Push to Connect62 scfm @ 80 psi0.090 to 1009015N110000000
    back to top