Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 10 Ft. of Head | @ 20 Ft. of Head | @ 30 Ft. of Head | Max. ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range, ° F | Power, hp | Current, amp | Pipe Size | Thread Type | Connection | Gender | Ht. | Wd. | Lg. | Each | |||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
NEMA 5-15 Plug with 30 ft. Long Cord | |||||||||||||||||||
| 70 | 50 | 24 | 36 | 3/8" | 4" | 35 to 120 | 1/2 | 10.3 | 1 1/2 | NPT | Threaded | Female | 15" | 7" | 7" | 3192K22 | 000000000 | ||
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
NEMA 6-15 Plug with 30 ft. Long Cord | |||||||||||||||||||
| — | 82 | 61 | 52 | 3/8" | 4" | 35 to 120 | 1 | 6.3 | 1 1/2 | NPT | Threaded | Female | 16" | 7" | 7" | 3192K18 | 00000000 | ||
Easy-Carry Dewatering Pumps without Switch
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. ft. of Head, ft. | Removes Water Down To | Temp. Range, ° F | Power, hp | Current, amp | Pipe Size | Thread Type | Connection | Gender | Ht. | Wd. | Lg. | Includes | Each | |||
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 10 ft. Long Cord | ||||||||||||||||||||
| 23 | 20 | 14 | 9 | 26 | 1/8" | 35 to 120 | 1/6 | 2 | 1 | NPT | Threaded | Female | 8" | 6" | 4.3" | Garden Hose Adapter | 99835K61 | 0000000 | ||
Plug with 25 ft. Long Cord | ||||||||||||||||||||
| 18 | 17 | 14 | 9 | 26.3 | 1/8" | 35 to 120 | 1/6 | 2 | 1 | NPT | Threaded | Female | 8" | 7" | 5" | Garden Hose Adapter | 99835K63 | 000000 | ||
Miniature Dewatering Pumps with Hose
Max. Flow Rate, gpm | Intake | Discharge | Overall | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. ft. of Head, ft. | Removes Water Down To | Temp. Range, ° F | Power, hp | Current, amp | Hose Size | Thread Type | Connection | Gender | Hose Size | Thread Type | Connection | Gender | Ht. | Wd. | Lg. | Includes | Each | |||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||||||
Plug with 6 ft. Long Cord | ||||||||||||||||||||||||
| 5.5 | 5 | 4.5 | 4 | 43 | 1/8" | 35 to 75 | 1/12 | 2 | 3/4 | GHT | Threaded | Male | 3/4 | GHT | Threaded | Male | 6" | 5" | 7" | 6 ft. of Garden Hose, Suction Strainer | 4193K11 | 0000000 | ||
Plastic Dewatering Pumps
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. ft. of Head, ft. | Removes Water Down To | Temp. Range, ° F | Power, hp | Current, amp | Pipe Size | Thread Type | Connection | Gender | Ht. | Wd. | Lg. | Includes | Each | |||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 8 ft. Long Cord | ||||||||||||||||||||
| 19 | 17 | 13 | 8 | 25 | 1/8" | 35 to 120 | 1/4 | 6 | 1 1/4 | NPT | Threaded | Female | 10" | 8" | 8" | Garden Hose Adapter | 3023K41 | 0000000 | ||
| 29 | 27 | 21 | 12 | 28 | 5/8" | 35 to 120 | 1/3 | 10 | 1 1/4 | NPT | Threaded | Female | 11" | 8" | 8" | Garden Hose Adapter | 99805K12 | 000000 | ||
High-Flow Dewatering Pumps
Pumps | Replacement Cords | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||||||
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | @ 30 Ft. of Head | Max. ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range, ° F | Power, hp | Current, amp | Pipe Size | Thread Type | Connection | Gender | Ht. | Wd. | Lg. | Each | Each | ||||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||||
Plug with 10 ft. Long Cord | ||||||||||||||||||||||
| 73 | 64 | 44 | 16 | 34 | 3/8" | 2" | 35 to 120 | 1/2 | 8 | 1 1/2 | NPT | Threaded | Female | 13" | 9" | 9" | 42805K22 | 0000000 | 42805K54 | 0000000 | ||
Plug with 25 ft. Long Cord | ||||||||||||||||||||||
| 48 | 43 | 23 | — | 26 | 3/8" | 2" | 35 to 120 | 1/3 | 4.9 | 1 1/4 | NPT | Threaded | Female | 9" | 6" | 6" | 42805K41 | 000000 | 42805K55 | 000000 | ||
| 73 | 64 | 44 | 16 | 34 | 3/8" | 2" | 35 to 120 | 1/2 | 8 | 1 1/2 | NPT | Threaded | Female | 13" | 9" | 9" | 42805K23 | 00000000 | 42805K56 | 000000 | ||
Compact Dewatering Pumps
12V DC, Single Phase
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | Max. ft. of Head, ft. | Removes Water Down To | Temp. Range, ° F | Sensor Time Interval, min. | Power | Current, amp | For Tube ID | Gender | Dia. | Ht. | Each | |||
ABS Housing | |||||||||||||||
Hardwire with 2 ft. Long Cord | |||||||||||||||
| 5 | 1 | 11 | 1/4" | 30 to 140 | 2.5 | Not Rated | 1.6 | 3/4" | Male | 3" | 4" | 3022K11 | 000000 | ||
| 10 | 3 | 10 | 1/4" | 30 to 140 | 2.5 | Not Rated | 3.7 | 1", 1 1/8" | Male | 3" | 5" | 3022K21 | 000000 | ||
120V AC, Single Phase
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | Max. ft. of Head, ft. | Removes Water Down To | Temp. Range, ° F | Sensor Time Interval, min. | Power | Current | Pipe Size | Thread Type | Gender | Dia. | Ht. | Includes | Each | |||
ABS Housing | |||||||||||||||||
Plug with 8 ft. Long Cord | |||||||||||||||||
| 20 | 13 | 18 | 1" | 40 to 140 | 2.5 | Not Rated | Not Rated | 1 | NPT | Male | 5" | 8" | Garden Hose Adapter | 3022K42 | 0000000 | ||
Plug with 24 ft. Long Cord | |||||||||||||||||
| 20 | 13 | 18 | 1" | 40 to 140 | 2.5 | Not Rated | Not Rated | 1 | NPT | Male | 5" | 8" | Garden Hose Adapter | 3022K43 | 000000 | ||
Portable Sewage Dewatering Pumps
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | Max. ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Turn-On | Turn-Off | Temp. Range, ° F | Power, hp | Current, amp | Pipe Size | Thread Type | Connection | Gender | Dia. | Dp. | Dia. | Ht. | Wd. | Lg. | Each | |||
240V AC, Single Phase | ||||||||||||||||||||||||
Hardwire with 25 ft. Long Cord | ||||||||||||||||||||||||
| — | 80 | 44 | 35 | 2" | 5 1/2" | 20" to 22" | 4" to 12" | 35 to 100 | 1 | 6.4 | 2 | NPT | Threaded | Male | 22" | 24" | — | 19" | 10" | 9" | 4184K94 | 000000000 | ||
| — | 114 | 79 | 46 | 2" | 5 1/2" | 20" to 22" | 4" to 12" | 35 to 100 | 1 1/2 | 8.4 | 2 | NPT | Threaded | Male | 22" | 24" | — | 19" | 10" | 9" | 4184K96 | 00000000 | ||
| 100 | 78 | 41 | 33 | 2" | 5 1/2" | 20" to 22" | 4" to 12" | 35 to 130 | 1 | 6.3 | 2 | NPT | Threaded | Female | 22" | 24" | 10" | 18" | — | — | 4184K81 | 00000000 | ||
| 134 | 114 | 77 | 41 | 2" | 5 1/2" | 20" to 22" | 4" to 12" | 35 to 130 | 1 1/2 | 8.4 | 2 | NPT | Threaded | Female | 22" | 24" | 10" | 18" | — | — | 4184K82 | 00000000 | ||
Dewatering Pumps with Hose
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Flow Rate, gpm | Max. ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range, ° F | Power, hp | Current, amp | Connection Coupling Size | Connection | Gender | Ht. | Wd. | Lg. | Includes | Each | |||
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||||||
Plug with 15" Long Cord | |||||||||||||||||||||
| 41 | 32 | 23 | 11 | 41 | 25 | 1/4" | 7/16" | 35 to 100 | 4/10 | 3 | 1 1/4 | Cam and Groove | Male | 12 3/4" | 11 13/16" | 15 3/4" | 25' Durable Cloth Hose, Carrying Cage | 3396N11 | 0000000 | ||
Harsh Environment Self-Priming Dewatering Pumps
Overall | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Max. Viscosity, cP | Temp. Range, ° F | Power, hp | Current, amp | Intake Size | Discharge Size | Ht. | Wd. | Lg. | Each | |||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Plug with 8 ft. Long Cord | ||||||||||||||||
| 5 4/5 | 30 | 1/4" | Not Rated | 125 | 60 to 180 | 1/4 | 4.2 | 1/2 NPT Female, 3/4 GHT Male | 1/2 NPT Female, 3/4 GHT Male | 9" | 5 5/8" | 7 3/8" | 4381K67 | 0000000 | ||
Long-Life Easy-Carry Dewatering Pumps
Max. Flow Rate, gpm | Level | Discharge | Overall | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | Max. ft. of Head, ft. | Removes Water Down To | Turn-On | Turn-Off | Temp. Range, ° F | Power, hp | Current, amp | Pipe Size | Thread Type | Connection | Gender | Ht. | Wd. | Lg. | Includes | Each | |||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||||
Plug with 10 ft. Long Cord | |||||||||||||||||||||
| 23 | 19 | 8 | 26 | 1/8" | 9" | 4" | 35 to 120 | 1/6 | 2 | 1 | NPT | Threaded | Female | 8" | 8" | 5" | Garden Hose Adapter | 99835K81 | 0000000 | ||
Plug with 18 ft. Long Cord | |||||||||||||||||||||
| 23 | 19 | 8 | 26 | 1/8" | 3" | 1 1/2" | 35 to 120 | 1/6 | 2 | 1 | NPT | Threaded | Female | 8" | 8" | 5" | Garden Hose Adapter | 99835K82 | 000000 | ||
Gasoline-Powered Dewatering Pumps
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 20 Ft. of Head | @ 50 Ft. of Head | @ 70 Ft. of Head | @ 90 Ft. of Head | Max. ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To, ft. | Tank Cap., qt. | Temp. Range, ° F | Power, hp | Pipe Size | Thread Type | Connection | Gender | Pipe Size | Thread Type | Connection | Gender | Ht. | Wd. | Lg. | Cannot Be Sold To | Each | |||
| 220 | 180 | 140 | 100 | 125 | 1" | 20 | 2.84 | 32 to 180 | 5 | 2 | NPT | Threaded | Female | 2 | NPT | Threaded | Female | 20" | 19 1/2" | 24" | Canada | 43465K26 | 0000000 | ||
| 340 | 280 | 220 | 140 | 110 | 3/4" | 20 | 5.5 | 40 to 180 | 8 | 3 | NPT | Threaded | Female | 3 | NPT | Threaded | Male | 23 1/2" | 22 1/2" | 31" | Canada | 43465K28 | 00000000 | ||
Battery-Powered Dewatering Pumps
Intake | Discharge | Overall | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate @ 5 ft. of Head, gpm | Max. ft. of Head, ft. | Removes Water Down To | Temp. Range, ° F | Power | Hose Size | Thread Type | Connection | Gender | Hose Size | Thread Type | Connection | Gender | Ht. | Wd. | Lg. | Each | |||
18V DC—With Thermal Overload Protection | |||||||||||||||||||
| 8 | 75 | Not Rated | 35 to 140 | Not Rated | 3/4 | GHT | Threaded | Male | 3/4 | GHT | Threaded | Male | 6" | 5 3/4" | 13 1/4" | 1949N11 | 0000000 | ||
Impact-Resistant Metal Dewatering Pumps
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. ft. of Head, ft. | Removes Water Down To | Temp. Range, ° F | Power, hp | Current, amp | Pipe Size | Thread Type | Connection | Gender | Ht. | Wd. | Lg. | Includes | Each | |||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 8 ft. Long Cord | ||||||||||||||||||||
| 19 | 17 | 13 | 8 | 25 | 1/8" | 35 to 120 | 1/4 | 5.6 | 1 1/4 | NPT | Threaded | Female | 9" | 7" | 7" | Garden Hose Adapter | 4250K51 | 0000000 | ||
Plug with 25 ft. Long Cord | ||||||||||||||||||||
| 19 | 17 | 13 | 8 | 25 | 1/8" | 35 to 120 | 1/4 | 5.6 | 1 1/4 | NPT | Threaded | Female | 9" | 7" | 7" | Garden Hose Adapter | 4250K52 | 000000 | ||
Corrosion-Resistant Gasoline-Powered Dewatering Pumps
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 20 Ft. of Head | @ 50 Ft. of Head | @ 70 Ft. of Head | @ 90 Ft. of Head | Max. ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To, ft. | Tank Cap., qt. | Temp. Range, ° F | Power, hp | Pipe Size | Thread Type | Connection | Gender | Pipe Size | Thread Type | Connection | Gender | Ht. | Wd. | Lg. | Cannot Be Sold To | Each | |||
| 153 | 125 | 93 | 58 | 98 | 1/2" | 10 | 3.8 | 40 to 160 | 5 | 2 | NPT | Threaded | Female | 2 | NPT | Threaded | Female | 20" | 20" | 25" | Canada | 3066K44 | 000000000 | ||
Drill-Operated Dewatering Pumps
![]() | ![]() | ![]() |
Pump | Pump with Intake and Discharge Tubes |
Intake | Discharge | Shaft | Overall | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. ft. of Head, ft. | Max. Viscosity, cP | Temp. Range, ° F | Hose Size | Thread Type | Connection | Gender | Hose Size | Thread Type | Connection | Gender | Motor Speed, rpm | Dia. | Lg. | Ht. | Wd. | Lg. | Includes | Each | |||
| 3 3/4 | 90 | 1 | 40 to 110 | 3/4 | GHT | Threaded | Male | 3/4 | GHT | Threaded | Male | 1,200 | 1/4" | 3/4" | 3" | 4 1/2" | 3" | — | 99705K21 | 000000 | ||
| 3 3/4 | 90 | 1 | 40 to 110 | 3/4 | GHT | Threaded | Male | 3/4 | GHT | Threaded | Male | 1,200 | 1/4" | 3/4" | 3" | 4 1/2" | 3" | 30" Slip-On Intake Tube, 34" Discharge Tube with 3/4" Male GHT Connection | 99705K25 | 00000 | ||
Heavy Duty Battery-Powered Dewatering Pumps
Discharge | Overall | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate @ 5 ft. of Head, gpm | Max. ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range, ° F | Power, hp | Current, amp | Pipe Size | Thread Type | Connection | Gender | Dia. | Ht. | Each | |||
12V DC—With Thermal Overload Protection | ||||||||||||||||
30 ft. Long Cord | ||||||||||||||||
| 41 | 20 | 1/4" | 1/4" | 35 to 190 | 1/3 | 30 | 1 1/2 | NPT | Threaded | Female | 9 37/64" | 22 3/64" | 1435N1 | 000000000 | ||
Hand-Operated Dewatering Pumps
Intake | Discharge | Overall | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, fl oz/stroke | Max. ft. of Head, ft. | Max. Solids Dia. | Max. Viscosity, cP | Temp. Range, ° F | For Hose ID | Connection | Gender | For Hose ID | Connection | Gender | Ht. | Wd. | Lg. | Each | |||
| 15 | 35 | 1/8" | 100,000 | 35 to 150 | 1" | Barbed | Male | 1" | Barbed | Male | 4 3/8" | 4 3/8" | 12 3/4" | 4332K31 | 000000 | ||
| 17 | 35 | 1/8" | 100,000 | 35 to 150 | 1 1/2" | Barbed | Male | 1 1/2" | Barbed | Male | 4 1/4" | 4 3/8" | 13 1/8" | 4332K33 | 000000 | ||
Mobile Gasoline-Powered Sewage Dewatering Pumps
Max. Flow Rate, gpm | Intake | Discharge | Overall | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 30 Ft. of Head | @ 60 Ft. of Head | @ 90 Ft. of Head | @ 100 Ft. of Head | Max. ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To, ft. | Temp. Range, ° F | Power, hp | Thread Type | Pipe Size | Gender | Thread Type | Pipe Size | Gender | Ht. | Wd. | Lg. | Cannot Be Sold To | Each | |||
1.6 gal. Tank | ||||||||||||||||||||||
| 530 | 335 | 110 | 20 | 103 | 2" | 20 | 40 to 180 | 13 | NPT | 4 | Female | NPT | 4 | Female | 31" | 38" | 45" | Canada | 43925K39 | 000000000 | ||
1.7 gal. Tank | ||||||||||||||||||||||
| 460 | 275 | 75 | — | 100 | 2" | 20 | 40 to 180 | 13 | NPT | 4 | Male | NPT | 4 | Male | 37" | 38" | 45" | Canada | 43925K29 | 00000000 | ||
Lightweight Plastic Gasoline-Powered Dewatering Pumps
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 20 Ft. of Head | @ 50 Ft. of Head | @ 70 Ft. of Head | @ 90 Ft. of Head | Max. ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To, ft. | Tank Cap., qt. | Temp. Range, ° F | Power, hp | Pipe Size | Thread Type | Connection | Gender | Pipe Size | Thread Type | Connection | Gender | Ht. | Wd. | Lg. | Cannot Be Sold To | Each | |||
| 132 | 106 | 84 | 56 | 115 | 7/16" | 20 | 2.28 | 40 to 130 | 5 | 2 | NPT | Threaded | Female | 2 | NPT | Threaded | Female | 19" | 16" | 13" | Canada | 3068K5 | 0000000 | ||