McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    4 Products

    Current-Sensing Test Leads

    Image of Product. Front orientation. Test Leads. Current-Sensing Test Leads, Current Loop.
    Image of Product. Front orientation. Test Leads. Current-Sensing Test Leads, Current Clamp.

    Current Loop

    Current Clamp

    Measure current without interrupting the circuit by connecting these test leads to a multimeter or current meter.
    The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter or current meter.
    These test leads step down the sensed current to a level that works with a multimeter or current meter—the signal reduction ratio is the factor by which they reduce current.
    Test End
    For Max.
    Cord Dia.
    Connection End
    AC Current,
    amp
    DC Current,
    amp
    Current
    Accuracy
    Voltage Output Signal
    Per Amp Supplied
    For Current Range
    AC Voltage,
    V AC
    Electrical Safety
    Rating
    Freq. Range,
    kHz
    Jaw
    Opening
    Loop
    Opening
    Cord
    Lg.
    Batteries
    Req.
    Batteries
    Included
    Each
    Measures AC Current
    Flexible Current LoopSheathed Standard Banana Plug5 to 3,0001%10.000 mV AC, 1.000 mV AC, 1.000 mV DC5 amp to 300 amp
    50 amp to 3,000 amp
    1,000CAT IV, 600V5 to 407.6"78"YesYes00000000000000
     
    Measures AC Current and DC Current
    Current Clamp1.22"Sheathed Standard Banana Plug0 to 1,0000 to 1,0001%1.000 mV AC, 1.000 mV DC0 amp to 200 amp
    0 amp to 1,000 amp
    300CAT III, 300V0 to 101.25"59"YesYes00000000000000
     

    Fluke Current-Sensing Test Leads

    Image of Product. Front orientation. Test Leads. Fluke Current-Sensing Test Leads, Current Clamp.

    Current Clamp

    Measure current without interrupting the circuit by connecting these test leads to a multimeter or current meter.
    The connection end is a 4 mm banana plug, which is the standard for connecting to a multimeter or current meter.
    These test leads step down the sensed current to a level that works with a multimeter or current meter—the signal reduction ratio is the factor by which they reduce current.
    Mfr. Model
    No.
    Test End
    For Max.
    Cord Dia.
    Connection End
    AC Current,
    amp
    Current
    Accuracy
    Current Output Signal per
    amp Supplied, mA
    For Current
    Range
    AC Voltage,
    V AC
    Electrical Safety
    Rating
    Freq. Range
    Jaw
    Opening
    For Fluke Model No.
    Cord
    Lg.
    Batteries
    Req.
    Each
    Measures AC Current
    i400Current Clamp1.25"Sheathed Standard Banana Plug1 to 4002%1.0001 amp to 400 amp1,000CAT IV, 600V5 Hz to 20 kHz1.25"27 II, 28 II, 77IV, 83V, 87V, 179, 287, 289, 787, 789, 1577, 158759"No00000000000000
     

    Clamp-On Multimeter Line Splitters

    Image of ProductInUse. Front orientation. Multimeter Line Splitters. Clamp-On Multimeter Line Splitters.
    Image of Product. Front orientation. Multimeter Line Splitters. Clamp-On Multimeter Line Splitters.
    Determine how much current a device with a two- or three-wire power cord uses without pulling apart the wires. The splitter isolates hot and neutral wires so you can measure AC current in either wire with a clamp-on multimeter.
    Max. AC Current,
    amp
    For No.
    of Wires
    Electrical Safety
    Rating
    Certification
    Each
    152, 3CAT II, 600VUL Listed, C-UL Listed0000000000000
    back to top