    142 Products

    Enclosed Isolating Transformers

    These transformers have isolated primary and secondary coils to protect your sensitive equipment from input voltage spikes.
    Single Phase—Plug Input and Socket Output Connection
    Image of Product. Front orientation. Transformers. Enclosed Isolating Transformers, Single Phase—Plug Input and Socket Output Connection.
    Image of Specification. NEMA 5-15 Plug. Front orientation. NEMA 5-15. Enclosed Isolating Transformers.
    Image of Specification. NEMA 6-15 Plug. Front orientation. NEMA 6-15. Enclosed Isolating Transformers.

    NEMA

    5-15

    Plug

    NEMA

    6-15

    Plug

    Image of Specification. NEMA 5-15 Socket. Front orientation. NEMA 5-15. Enclosed Isolating Transformers.

    NEMA

    5-15

    Socket

    Constant Voltage—When wired as constant-voltage transformers, they filter out voltage spikes and electrical noise.
    Voltage,
    V AC
    Input
    Output
    Input
    Output
    Power Output,
    VA
    Plug Connection
    Connection
    NEMA Type
    Socket
    Connection
    Connection
    NEMA Type
    Ht.
    Wd.
    Dp.
    Features
    Each
    Constant Voltage
    1151151503-Blade Straight5-15
    3-Slot Straight5-15
    3.9"3.1"4.2"Isolated Coils70245K710000000
    1151152503-Blade Straight5-15
    3-Slot Straight5-15
    4.7"3.8"4.4"Isolated Coils70245K72000000
    1151151,0003-Blade Straight5-15
    3-Slot Straight5-15
    5.3"4 1/2"8.1"Isolated Coils70245K74000000
     
    Step-Down Voltage
    2301151003-Blade Straight6-15
    3-Slot Straight5-15
    3 1/2"2.8"3.6"Isolated Coils70245K81000000
    2301152503-Blade Straight6-15
    3-Slot Straight5-15
    4.7"3.8"4.4"Isolated Coils70245K83000000
    2301155003-Blade Straight6-15
    3-Slot Straight5-15
    4.7"3.8"6"Isolated Coils70245K84000000
     
    Single Phase—Wire Leads Input and Output Connection
    Image of Product. Front orientation. Transformers. Enclosed Isolating Transformers, Single Phase—Wire Leads Input and Output Connection.
    Constant Voltage—When wired as constant-voltage transformers, they filter out voltage spikes and electrical noise.
    Sealed Cores—Sealed coils and cores prevent corrosion and insulation damage.
    Voltage,
    V AC
    Input
    Output
    Power Output,
    VA
    Ht.
    Wd.
    Dp.
    Features
    Environment
    Enclosure
    Rating
    Certification
    Each
    Step-Up/Step-Down/Constant Voltage
    120/240120/2401,00010 1/2"6.1"5.2"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, C-UL Listed
    6989K210000000
    120/240120/2402,00013"5 1/2"5.1"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, C-UL Listed
    6989K23000000
    120/240120/2403,00011 1/2"10.3"7.1"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, C-UL Listed
    6989K24000000
    120/240120/2405,00014.4"10.3"7.1"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, C-UL Listed
    6989K2500000000
     
    Step-Down/Constant Voltage
    240/480120/24075011.3"5.3"6 1/2"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, C-UL Listed
    7131K19000000
    240/480120/2401,00011.3"5.3"6 1/2"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, C-UL Listed
    7131K21000000
    240/480120/2401,50013.3"6.3"7.8"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, C-UL Listed
    7131K22000000
    240/480120/2403,00013.3"6.3"7.8"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, C-UL Listed
    7131K23000000
    240/480120/2405,00015"10.2"10.6"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, C-UL Listed
    7131K24000000
    240/480120/24010,00015.2"13 1/2"10.8"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, CSA Certified
    7131K2600000000
    240/480120/24015,00020"10.8"13.6"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, CSA Certified
    7131K2700000000
    240/480120/24025,00023"12.1"14.6"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, CSA Certified
    7131K2800000000
     
    Three Phase—Wire Leads Input and Output Connection
    Image of Product. Front orientation. Transformers. Enclosed Isolating Transformers, Three Phase—Wire Leads Input and Output Connection.
    Three-phase transformers have Wye wiring for output voltage.
    Sealed Cores—Sealed coils and cores prevent corrosion and insulation damage.
    Voltage,
    V AC
    Input
    Output
    Power Output,
    VA
    Ht.
    Wd.
    Dp.
    Features
    Environment
    Enclosure
    Rating
    Certification
    Each
    Step-Down Voltage
    480120/2083,00010.4"12.4"7 1/2"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, CSA Certified
    7131K38000000000
    480120/2086,00011.8"14.2"8.8"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, CSA Certified
    7131K3900000000
    480120/2089,00014"17.8"11 1/2"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, CSA Certified
    7131K4100000000
    480120/20815,00018.9"20.3"9"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, CSA Certified
    7131K4200000000
     
    Three Phase—Bus-Bar Input and Output Connection
    Image of Product. Front orientation. Transformers. Enclosed Isolating Transformers, Three Phase—Bus-Bar Input and Output Connection.
    Three-phase transformers have Wye wiring for output voltage.
    Sealed Cores—Sealed coils and cores prevent corrosion and insulation damage.
    Cannot Be Sold to California—Transformers that cannot be sold to California are restricted by local energy efficiency regulations.
    Voltage,
    V AC
    Input
    Output
    Power Output,
    VA
    Ht.
    Wd.
    Dp.
    Features
    Environment
    Enclosure
    Rating
    Certification
    Cannot Be
    Sold To
    Each
    Step-Down Voltage
    480120/20830,00025 1/2"24.4"19.4"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, CSA Certified
    California7131K43000000000
    480120/20845,00025 1/2"24.4"19.4"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, CSA Certified
    California7131K4400000000
    480120/20875,00029.4"28.2"22.4"Isolated Coils, Sealed Coils, Sealed CoresOutdoor, WetNEMA 3R
    UL Listed, CSA Certified
    California7131K4500000000
     

    Enclosed Step-Up/Step-Down-Voltage Transformers

    Improve the efficiency of your equipment—wire these transformers to step your input voltage up or down by as much as 20%. Choose an input/output voltage combination that comes closest to matching your application, then choose the power output (in VA) of the equipment you want to operate. You probably won’t find the exact value you need; choose the next highest rating.
    Note: Transformers are labeled with a prewired power output and pre-wired primary and secondary voltages. Single-phase transformers are labeled as 120/240V AC primary voltage and 12/24V AC secondary voltage. Three-phase transformers are labeled as 120/240V AC primary voltage and 16/32V AC secondary voltage. All possible input voltage and output voltage wiring combinations are listed.
    Single Phase—Wire Leads Input and Output Connection
    Image of Product. Front orientation. Transformers. Enclosed Step-Up/Step-Down-Voltage Transformers.
    Labeled
    Input/Output Voltage—Power
    Output
    Power Output,
    VA
    Primary Voltage,
    V AC
    Secondary Voltage,
    V AC
    Ht.
    Wd.
    Dp.
    Each
    Step-Up/Step-Down Voltage
    100V AC/120V AC—250 VA
    110V AC/120V AC—500 VA
    125V AC/113V AC—520 VA
    132V AC/120V AC—540 VA
    189V AC/208V AC—430 VA
    208V AC/230V AC—480 VA
    220V AC/242V AC—500 VA
    230V AC/208V AC—470 VA
    245V AC/222V AC—500 VA
    252V AC/240V AC—1,020 VA
    50120/24012/246.4"3.1"3.1"70525K710000000
    100V AC/120V AC—500 VA
    110V AC/120V AC—1,010 VA
    125V AC/113V AC—1,040 VA
    132V AC/120V AC—1,080 VA
    189V AC/208V AC—870 VA
    208V AC/230V AC—960 VA
    220V AC/242V AC—1,010 VA
    230V AC/208V AC—950 VA
    245V AC/222V AC—1,000 VA
    252V AC/240V AC—2,040 VA
    100120/24012/247.2"3.9"3.7"70525K72000000
    100V AC/120V AC—750 VA
    110V AC/120V AC—1,510 VA
    125V AC/113V AC—1,560 VA
    132V AC/120V AC—1,620 VA
    189V AC/208V AC—1,300 VA
    208V AC/230V AC—1,430 VA
    220V AC/242V AC—1,510 VA
    230V AC/208V AC—1,420 VA
    245V AC/222V AC—1,500 VA
    252V AC/240V AC—3,000 VA
    150120/24012/247.2"3.9"3.7"70525K73000000
    100V AC/120V AC—1,250 VA
    110V AC/120V AC—2,500 VA
    125V AC/113V AC—2,600 VA
    132V AC/120V AC—2,750 VA
    189V AC/208V AC—2,160 VA
    208V AC/230V AC—2,390 VA
    220V AC/242V AC—2,520 VA
    230V AC/208V AC—2,370 VA
    245V AC/222V AC—2,500 VA
    252V AC/240V AC—5,100 VA
    250120/24012/248.7"4.1"3.9"70525K74000000
    100V AC/120V AC—2,500 VA
    110V AC/120V AC—5,000 VA
    125V AC/113V AC—5,200 VA
    132V AC/120V AC—5,400 VA
    189V AC/208V AC—4,330 VA
    208V AC/230V AC—4,790 VA
    220V AC/242V AC—5,040 VA
    230V AC/208V AC—4,470 VA
    245V AC/222V AC—5,000 VA
    252V AC/240V AC—10,200 VA
    500120/24012/249.1"4.4"4.2"70525K75000000
    100V AC/120V AC—3,750 VA
    110V AC/120V AC—7,560 VA
    125V AC/113V AC—7,800 VA
    132V AC/120V AC—8,150 VA
    189V AC/208V AC—6,500 VA
    208V AC/230V AC—7,190 VA
    220V AC/242V AC—7,560 VA
    230V AC/208V AC—7,100 VA
    245V AC/222V AC—7,500 VA
    252V AC/240V AC—15,300 VA
    750120/24012/249.7"4.8"4 1/2"70525K76000000
    100V AC/120V AC—5,000 VA
    110V AC/120V AC—10,000 VA
    125V AC/113V AC—10,400 VA
    132V AC/120V AC—10,800 VA
    189V AC/208V AC—8,660 VA
    208V AC/230V AC—9,580 VA
    220V AC/242V AC—10,000 VA
    230V AC/208V AC—9,500 VA
    245V AC/222V AC—10,000 VA
    252V AC/240V AC—20,400 VA
    1,000120/24012/2410 1/2"5 1/2"5.1"70525K77000000
     
    Single/Three Phase—Wire Leads Input and Output Connection
    Image of Product. Front orientation. Transformers. Enclosed Step-Up/Step-Down-Voltage Transformers.
    Three-phase applications require two transformers.
    Labeled
    Input/Output Voltage—Power
    Output
    Power Output,
    VA
    Primary Voltage,
    V AC
    Secondary Voltage,
    V AC
    Ht.
    Wd.
    Dp.
    Each
    Step-Up/Step-Down Voltage
    195V AC/208V AC—5,630 VA
    208V AC/240V AC—3,170 VA
    225V AC/240V AC—6,500 VA
    240V AC/208V AC—2,810 VA
    245V AC/230V AC—6,630 VA
    256V AC/240V AC—6,930 VA
    265V AC/234V AC—3,590 VA
    272V AC/240V AC—3,680 VA
    250120/24016/328.7"4.1"3.9"70525K810000000
    195V AC/208V AC—11,260 VA
    208V AC/240V AC—6,330 VA
    225V AC/240V AC—12,990 VA
    240V AC/208V AC—5,630 VA
    245V AC/230V AC—13,260 VA
    256V AC/240V AC—13,860 VA
    265V AC/234V AC—7,170 VA
    272V AC/240V AC—7,360 VA
    500120/24016/329.1"4.4"4.2"70525K82000000
    195V AC/208V AC—16,890 VA
    208V AC/240V AC—9,500 VA
    225V AC/240V AC—19,490 VA
    240V AC/208V AC—8,440 VA
    245V AC/230V AC—19,890 VA
    256V AC/240V AC—20,780 VA
    265V AC/234V AC—10,760 VA
    272V AC/240V AC—11,040 VA
    750120/24016/329.7"4.8"4 1/2"70525K83000000
    195V AC/208V AC—22,520 VA
    208V AC/240V AC—12,670 VA
    225V AC/240V AC—25,980 VA
    240V AC/208V AC—11,260 VA
    245V AC/230V AC—26,520 VA
    256V AC/240V AC—27,710 VA
    265V AC/234V AC—14,340 VA
    272V AC/240V AC—14,720 VA
    1,000120/24016/3210 1/2"5 1/2"5.1"70525K84000000
     

    High-Inrush Panel-Mount Transformers

    These transformers can handle momentary high-inrush current associated with contactors, solenoids, and relays. Also known as control transformers.
    Single Phase—Screw-Terminal Input and Output Connection
    Image of Product. Front orientation. Transformers. High-Inrush Panel-Mount Transformers, Single Phase—Screw-Terminal Input and Output Connection.
    Voltage,
    V AC
    Input
    Output
    Power Output,
    VA
    Ht.
    Wd.
    Dp.
    Certification
    Each
    Step-Down Voltage
    120/24012/24502.8"3"3.3"UL Listed, C-UL Listed
    6988K91000000
    120/24012/24752.8"3"3.8"UL Listed, C-UL Listed
    6988K9200000
    120/24012/241003.1"3.4"3.8"UL Listed, C-UL Listed
    6988K9300000
    120/24012/241503.4"3.8"4.3"UL Listed, C-UL Listed
    6988K94000000
    120/24012/242504"4 1/2"4 1/2"UL Listed, C-UL Listed
    6988K95000000
    120/24012/243504"4 1/2"5.3"UL Listed, CSA Certified
    6988K66000000
    120/24012/245004.6"5.3"5.8"UL Listed, C-UL Listed
    6988K67000000
    120/24012/247504.7"5.3"7"UL Listed, C-UL Listed
    6988K68000000
    230/460/57595/115502.8"3"3.3"UL Listed, C-UL Listed
    6988K8100000
    230/460/57595/1151003"3.4"3.8"UL Listed, C-UL Listed
    6988K82000000
    230/460/57595/1151503.4"3.8"4.3"UL Listed, C-UL Listed
    6988K83000000
    230/460/57595/1152504"4 1/2"4.6"UL Listed, C-UL Listed
    6988K84000000
    230/460/57595/1153504"4 1/2"5.3"UL Listed, C-UL Listed
    6988K85000000
    230/460/57595/1155004.6"5.3"5.8"UL Listed, C-UL Listed
    6988K86000000
    240/480120502.6"3"3.1"UL Listed, CSA Certified
    6988K31000000
    240/4801201002.9"3.4"3.3"UL Listed, CSA Certified
    6988K32000000
    240/4801201503.2"3.8"3.6"UL Listed, CSA Certified
    6988K33000000
    240/4801202503.2"3.8"5.3"UL Listed, CSA Certified
    6988K34000000
    240/4801203503.8"4 1/2"5.1"UL Listed, CSA Certified
    6988K35000000
    240/4801205003.8"4 1/2"5 1/2"UL Listed, CSA Certified
    6988K36000000
    240/4801207504 1/2"5.3"5.6"UL Listed, CSA Certified
    6988K37000000
    240/4801201,0004 1/2"5.3"6.3"UL Listed, CSA Certified
    6988K38000000
    240/4801201,5006.2"7.1"5.9"UL Listed, CSA Certified
    6988K39000000
    240/4801202,0005.4"7"8.4"UL Listed, C-UL Listed
    6988K74000000
     
    Single Phase—Screw-Terminal Input and Output Connection with Fuse Block
    Image of Product. Front orientation. Transformers. High-Inrush Panel-Mount Transformers, Single Phase—Screw-Terminal Input and Output Connection with Fuse Block.
    Input and output fuse blocks are built-in and top-mounted to save panel space and allow quick installation.
    Voltage,
    V AC
    For
    Fuse
    Input
    Output
    Power Output,
    VA
    Ht.
    Wd.
    Dp.
    Type
    Overall
    Dia.
    Certification
    Each
    Step-Down Voltage
    120/24012/24504"3"3.6"Midget13/32"UL Listed, C-UL Listed
    6988K210000000
    230/460/57595/1151004.4"3.4"4.1"Midget13/32"UL Listed, C-UL Listed
    6988K22000000
    240/480120504"3"3.1"Midget13/32"UL Listed, CSA Certified
    6988K51000000
    240/4801201004.2"3.4"3.3"Midget13/32"UL Listed, CSA Certified
    6988K52000000
    240/4801201504 1/2"3.8"3.6"Midget13/32"UL Listed, CSA Certified
    6988K53000000
    240/4801202504 1/2"3.8"5.3"Midget13/32"UL Listed, CSA Certified
    6988K54000000
    240/4801203505.1"4 1/2"5.1"Midget13/32"UL Listed, CSA Certified
    6988K55000000
    240/4801205005.1"4 1/2"5 1/2"Midget13/32"UL Listed, CSA Certified
    6988K56000000
    240/4801207505.8"5.3"5.6"Midget13/32"UL Listed, CSA Certified
    6988K57000000
    240/4801201,0005.8"5.3"6.3"Midget13/32"UL Listed, CSA Certified
    6988K58000000
    240/4801201,5007.7"6.8"8.1"Midget13/32"UL Listed, C-UL Listed
    6988K23000000
    240/4801202,0007.7"6.8"7.8"Midget13/32"UL Listed, CSA Certified
    6988K24000000
     

    Touch-Safe High-Inrush Panel-Mount Transformers

    Prevent accidental contact with live electrical connections—the screw terminals are covered or recessed. These transformers can handle momentary high-inrush current associated with contactors, solenoids, and relays. Also known as control transformers.
    Single Phase—Screw-Terminal Input and Output Connection
    Image of Product. Front orientation. Transformers. Touch-Safe High-Inrush Panel-Mount Transformers.
    Constant Voltage—When wired for constant voltage, transformers filter out voltage spikes and electrical noise.
    Isolated Coils—Isolated coils protect equipment from input voltage spikes.
    Voltage,
    V AC
    Input
    Output
    Power Output,
    VA
    Ht.
    Wd.
    Dp.
    Features
    Certification
    Each
    Step-Down Voltage
    120/24024502.8"3"3.3"Covered Terminals, Isolated CoilsUL Listed, C-UL Listed, CE Marked
    7038K51000000
    120/24024752.8"3"3.8"Covered Terminals, Isolated CoilsUL Listed, C-UL Listed
    7038K52000000
    120/240241003.1"3.4"3.8"Covered Terminals, Isolated CoilsUL Listed, C-UL Listed, CE Marked
    7038K53000000
    120/240241503.4"3.8"4.3"Covered Terminals, Isolated CoilsUL Listed, C-UL Listed
    7038K54000000
    120/240242504"4 1/2"4.6"Covered Terminals, Isolated CoilsUL Listed, CSA Certified, CE Marked
    7038K55000000
    120/240245004.7"5.3"5.8"Covered Terminals, Isolated CoilsUL Listed, C-UL Listed
    7038K57000000
    120/240241,0005.7"7"6.6"Covered Terminals, Isolated CoilsUL Listed, C-UL Listed, CE Marked
    7038K59000000
    240/480120502.8"3"3.3"Covered Terminals, Isolated CoilsUL Listed, C-UL Listed, CE Marked
    7038K6100000
    240/480120752.8"3"3.8"Covered Terminals, Isolated CoilsUL Listed, C-UL Listed, CE Marked
    7038K6200000
    240/4801201003.1"3.4"3.8"Covered Terminals, Isolated CoilsUL Listed, C-UL Listed, CE Marked
    7038K6300000
    240/4801202504"4 1/2"4.6"Covered Terminals, Isolated CoilsUL Listed, C-UL Listed, CE Marked
    7038K65000000
    240/4801203504"4 1/2"5.3"Covered Terminals, Isolated CoilsUL Listed, C-UL Listed
    7038K67000000
    240/4801205004.7"5.3"5.8"Covered Terminals, Isolated CoilsUL Listed, C-UL Listed, CE Marked
    7038K68000000
    240/4801207504.7"5.3"7"Covered Terminals, Isolated CoilsUL Listed, C-UL Listed, CE Marked
    7038K69000000
    240/4801201,0005.7"7"6.6"Covered Terminals, Isolated CoilsUL Listed, C-UL Listed, CE Marked
    7038K71000000
    240/4801201,5005.7"7"7.6"Covered Terminals, Isolated CoilsUL Listed, C-UL Listed, CE Marked
    7038K72000000
    240/4801202,0005 1/2"7"8.4"Covered Terminals, Isolated CoilsUL Listed, C-UL Listed, CE Marked
    7038K73000000
     
    Step-Down/Constant Voltage
    230/460/57524/115/2302504"4 1/2"4.8"Covered TerminalsUL Listed, C-UL Listed, CE Marked
    6718T51000000
    230/460/57524/115/2303004"4 1/2"5.3"Covered TerminalsUL Listed, C-UL Listed, CE Marked
    6718T52000000
    230/460/57524/115/2303504 1/2"5.3"5.4"Covered TerminalsUL Listed, C-UL Listed, CE Marked
    6718T53000000
    230/460/57524/115/2305004 1/2"5.3"6.6"Covered TerminalsUL Listed, C-UL Listed, CE Marked
    6718T54000000
    230/460/57524/115/2307506"6.4"7.4"Covered TerminalsUL Listed, C-UL Listed, CE Marked
    6718T55000000
    230/460/57524/115/2301,0006.3"6.8"7.8"Covered TerminalsUL Listed, C-UL Listed, CE Marked
    6718T56000000
     

    Enclosed Voltage-Stabilizing Transformers

    Protect sensitive equipment from electromagnetic interference and maintain power during three-millisecond power dips. These transformers also isolate output and input voltage (output regulation is ±3% with input voltage fluctuations from +10% to -20%). When wired for constant voltage, transformers filter out voltage spikes and electrical noise.
    Single Phase—Screw-Terminal Input and Output Connection
    Image of Product. Front orientation. Transformers. Enclosed Voltage-Stabilizing Transformers.
    Voltage,
    V AC
    Input
    Output
    Power Output,
    VA
    Ht.
    Wd.
    Dp.
    Features
    Certification
    Each
    Step-Up/Step-Down/Constant Voltage
    120/208/240/480120/208/2401404.4"6"8 1/2"Isolated CoilsUL Listed, CSA Certified
    7425K330000000
    120/208/240/480120/208/2402504.4"6"9.7"Isolated CoilsUL Listed, CSA Certified
    7425K34000000
    120/208/240/480120/208/2405006 1/2"6.3"12.3"Isolated CoilsUL Listed, CSA Certified
    7425K35000000
    120/208/240/480120/208/2407506 1/2"6.3"13.3"Isolated CoilsUL Listed, CSA Certified
    7425K3600000000
    120/208/240/480120/208/2401,0006 1/2"6.3"14.2"Isolated CoilsUL Listed, CSA Certified
    7425K3700000000
    120/208/240/480120/208/2401,5009.9"9.4"17.6"Isolated CoilsUL Listed, CSA Certified
    7425K3900000000
    120/208/240/480120/208/2403,0009.9"9.4"19.9"Isolated CoilsUL Listed, CSA Certified
    7425K4200000000
     

    DIN-Rail/Panel-Mount High-Inrush Transformers

    Image of ProductInUse. Front orientation. Transformers. DIN-Rail/Panel-Mount High-Inrush Transformers.
    Use with DIN-rail to install wherever you need these transformers or mount them to a panel. They can handle momentary high-inrush current associated with equipment start-up.
    Single Phase—Screw-Terminal Input and Output Connection
    Voltage,
    V AC
    Input
    Output
    Power Output,
    VA
    Ht.
    Wd.
    Dp.
    For DIN
    Rail Size, mm
    Certification
    Each
    Step-Down Voltage
    23024633 1/2"3.4"3.9"35UL Recognized Component, C-UL Recognized Component, CE Marked
    7962K610000000
    230241004"3.4"3.9"35UL Recognized Component, C-UL Recognized Component, CE Marked
    7962K62000000
    230241604.1"3.9"4.2"35UL Recognized Component, C-UL Recognized Component, CE Marked
    7962K63000000
    230242504.7"3.9"4.2"35UL Recognized Component, C-UL Recognized Component, CE Marked
    7962K64000000
    230/460115633 1/2"3.4"3.9"35UL Recognized Component, C-UL Recognized Component, CE Marked
    7962K71000000
    230/4601151004"3.4"3.9"35UL Recognized Component, C-UL Recognized Component, CE Marked
    7962K72000000
    230/4601151604.1"3.9"4.2"35UL Recognized Component, C-UL Recognized Component, CE Marked
    7962K73000000
    230/4601152504.7"3.9"4.2"35UL Recognized Component, C-UL Recognized Component, CE Marked
    7962K7400000000
    230/4601154004 1/2"4.8"4.8"35UL Recognized Component, C-UL Recognized Component, CE Marked
    7962K7600000000
    230/4601155005.3"4.8"4.8"35UL Recognized Component, C-UL Recognized Component, CE Marked
    7962K7700000000
     

    Outlet-Box/Panel-Mount High-Inrush Transformers

    Use the included mounting plate to mount these transformers to a panel. They can handle momentary high-inrush current associated with equipment start-up. Also known as control transformers, they are used in heating, ventilation, and air conditioning control circuits.
    Single Phase—Wire Leads Input and Output Connection
    Image of Product. Front orientation. Transformers. Outlet-Box/Panel-Mount High-Inrush Transformers.
    Voltage,
    V AC
    Input
    Output
    Power Output,
    VA
    Wire Lead
    Lg.
    Ht.
    Wd.
    Dp.
    Certification
    Each
    Step-Down Voltage
    12024406"2.8"3.7"2 1/2"UL Recognized Component
    7708K21000000
    120/208/24024406"2.8"3.7"2 1/2"UL Recognized Component
    7708K2200000
    208/24024406"2.8"3.7"2 1/2"UL Recognized Component
    7708K2300000
     

    Harsh-Environment High-Inrush Panel-Mount Transformers

    Image of Product. Transformer with Input and Output Fuse Block. Front orientation. Input Fuse Block. Harsh-Environment High-Inrush Panel-Mount Transformers, Output Fuse Block.
    Image of Product. Transformer with Input Fuse Block. Front orientation. Input Fuse Block. Harsh-Environment High-Inrush Panel-Mount Transformers, 12V AC Output Voltage.
    Image of Product. Transformer with Output Fuse Block. Front orientation. Output Fuse Block. Harsh-Environment High-Inrush Panel-Mount Transformers, 12V AC Output Voltage.

    Transformer with

    Input and Output

    Fuse Block

    Transformer with

    Input Fuse Block

    Transformer with

    Output Fuse Block

    Sealed coils protect against dust, dirt, oil, and moisture. These transformers can handle momentary high-inrush current associated with contactors, solenoids, and relays. Also known as control transformers. Choose a transformer with multiple output voltages to simultaneously power multiple devices that require different output voltages.
    Step-Down Voltage—Input and Output Fuse Block, Sealed Coils—Input and output fuse blocks are built-in and top-mounted to save panel space and allow quick installation.
    Voltage,
    V AC
    For Fuse
    Input
    Output
    Power Output,
    VA
    Ht.
    Wd.
    Dp.
    UL
    Class
    Type
    Overall
    Dia.
    Certification
    Each
    Single Phase—Screw-Terminal Input and Output Connection
     
    Step-Down Voltage—Input Fuse Block, Sealed Coils
    120/24012/24504"3"3.8"Midget13/32"UL Listed, C-UL Listed
    7034K71000000
    120/24012/24754"3"4"Midget13/32"UL Listed, C-UL Listed
    7034K7200000
    120/24012/241004.4"3.4"4"Midget13/32"UL Listed, C-UL Listed
    7034K73000000
    120/24012/241504.7"3.8"4.4"Midget13/32"UL Listed, C-UL Listed
    7034K74000000
    120/24012/242505.3"4 1/2"4.6"Midget13/32"UL Listed, C-UL Listed
    7034K75000000
    120/24012/245006"5.3"5.3"Midget13/32"UL Listed, C-UL Listed
    7034K79000000
     
    Step-Down Voltage—Output Fuse Block, Sealed Coils
    120/24012503.1"3"3.8"Midget13/32"UL Listed, C-UL Listed
    7034K6100000
    120/24012753.1"3"4"Midget13/32"UL Listed, C-UL Listed
    7034K6200000
    120/240121003 1/2"3.4"4"Midget13/32"UL Listed, C-UL Listed
    7034K63000000
    120/240121503.8"3.8"4"Midget13/32"UL Listed, C-UL Listed
    7034K64000000
    240/48012503.1"3"3.8"Midget13/32"UL Listed, C-UL Listed
    7034K6500000
    240/480121503.8"3.8"4"Midget13/32"UL Listed, C-UL Listed
    7034K68000000
     
    Step-Down Voltage—Input and Output Fuse Block, Sealed Coils
    230/46024/115503.9"3"3 1/2"CCMidget13/32"UL Listed, C-UL Listed
    6718T71000000
    230/46024/115754.2"3.4"3.6"CCMidget13/32"UL Listed, C-UL Listed
    6718T72000000
    230/46024/1151004.2"3.8"3.6"CCMidget13/32"UL Listed, C-UL Listed
    6718T73000000
    230/46024/1151504.7"3.8"4"CCMidget13/32"UL Listed, C-UL Listed
    6718T74000000
    230/46024/1152005.3"4 1/2"4.4"CCMidget13/32"UL Listed, C-UL Listed
    6718T75000000
    230/46024/1152504.1"4 1/2"4.4"CCMidget13/32"UL Listed, C-UL Listed
    6718T76000000
    230/46024/1153005.9"5.3"5.2"CCMidget13/32"UL Listed, C-UL Listed
    6718T77000000
    230/46024/1153505.9"5.3"5.2"CCMidget13/32"UL Listed, C-UL Listed
    6718T78000000
    230/46024/1155006"5.3"5.7"CCMidget13/32"UL Listed, C-UL Listed
    6718T79000000
    240/480120504"3"3.8"Midget13/32"UL Listed, C-UL Listed
    7034K5100000
    240/480120754"3"4"Midget13/32"UL Listed, C-UL Listed
    7034K5200000
    240/4801201004.3"3.4"4"Midget13/32"UL Listed, C-UL Listed
    7034K53000000
    240/4801201504.7"3.8"4"Midget13/32"UL Listed, C-UL Listed
    7034K54000000
    240/4801202505.3"4 1/2"4.4"Midget13/32"UL Listed, C-UL Listed
    7034K55000000
    240/4801205006"5.3"6.1"Midget13/32"UL Listed, C-UL Listed
    7034K58000000
     
    back to top