McMaster-Carr logo
    Filter by
    Inlet Diameter
    Outlet Diameter
    Duct Size
    Electrical Phase
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Electrical Connection Type
    Nozzle Diameter
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    67 Products

    Chemical-Resistant Duct and Fittings

    Image of System. Front orientation. Contains MultipleImages. Duct and Fittings. Chemical-Resistant Duct and Fittings.
    Chemicals can eat away at most metal duct, but not this PVC system. It’s often used to exhaust corrosive gases, vapors, and fumes. Components press-fit together and secure with PVC pipe cement.
    Intake Hoods
    Image of Product. Front orientation. Duct and Fittings. Chemical-Resistant Duct and Fittings, Intake Hoods.
    Capture air, vapors, and fumes and funnel them away. These hoods direct contaminants into your duct system and away from workers and machines.
    PVC
    Duct
    Size
    ID
    Color
    Each
    44 1/2"Gray2051K8730000000
    66 5/8"Gray2051K874000000
    88 5/8"Gray2051K875000000
    1010 3/4"Gray2051K876000000
    1212 3/4"Gray2051K877000000
     

    Fume Hoods

    Image of Product. Front orientation. Contains Annotated. Fume Hoods. Polyethylene with Adjustable Sliding Window.
    Image of Product. Front orientation. Contains Annotated. Fume Hoods. Polypropylene with Adjustable Sliding Window.

    Polyethylene with Adjustable Sliding Window

    Polypropylene with Adjustable Sliding Window

    Image of Product. Front orientation. Contains Annotated. Fume Hoods. Polycarbonate with Adjustable Sliding Window.

    Polycarbonate with Adjustable Sliding Window

    Pair these hoods with an exhaust system to contain harmful fumes, vapors, and gasses while venting them away from work spaces—they protect users from inhaling or coming in contact with them. To access the enclosed space, these hoods have an adjustable sliding window, which also lets your exhaust system pull air from the outside. All of these hoods resist chemicals and corrosion.
    Polyethylene—Polyethylene hoods have a molded one-piece construction with rounded inside corners to prevent gaps and crevices, making them easy to wipe clean.
    Polypropylene—Polypropylene hoods are nonconductive. They’re also translucent, so they let in more light than polyethylene hoods for added visibility.
    Polycarbonate—Polycarbonate hoods are dent and scratch resistant. They’re also clear, offering an unobstructed view from all sides.
    Polycarbonate Window—Polycarbonate windows are more durable than acrylic windows.
    Overall
    Opening
    Windows
    Outlets
    Recommended Airflow,
    ft³/min
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    No.
    of
    Material
    Clarity
    No.
    of
    OD
    Gender
    Each
    Polyethylene with Adjustable Sliding Window
    20022"27"13"12"22"1Acrylic Plastic
    Clear14", 6"Male20995K610000000
    35030"42"20"14 1/8"34 1/2"1Acrylic Plastic
    Clear16"Male20995K6200000000
     
    Polypropylene with Adjustable Sliding Window
    50036"48"24"21"46"1Acrylic Plastic
    Clear16"Male20995K6500000000
     
    Polycarbonate with Adjustable Sliding Window
    20026 1/8"25 7/8"24"13"20 1/8"1Polycarbonate
    Clear16"Male20995K6300000000
    20026 1/8"43 7/8"24"13"38 1/8"1Polycarbonate
    Clear26"Male20995K6400000000
     

    Positionable-Arm Fume Exhaust Hoses

    Image of Product. Front orientation. Fume Exhaust Hoses. Positionable-Arm Fume Exhaust Hoses.
    Move the hose into position and the support arm will hold it in place. These hoses remove fumes, vapors, and fine dust particles from your space. They are commonly used in welding, soldering, and other operations that create fumes.
    Hose
    Nozzle
    Mounting
    ID
    Lg.,
    ft.
    Material
    Dia.
    Material
    Fasteners
    Included
    For Screw
    Size
    Hole
    Dia.
    Number
    of Holes
    Includes
    Each
    Ceiling and Wall Mount
    4"5PVC10"SteelNo3/8"
    1/2"4Hose, Mounting Bracket, Nozzle2105K41000000000
    4"7PVC10"SteelNo3/8"
    1/2"4Hose, Mounting Bracket, Nozzle2105K4200000000
    4"8.5PVC10"SteelNo3/8"
    1/2"4Hose, Mounting Bracket, Nozzle2105K4300000000
    6"7PVC13"SteelNo3/8"
    1/2"6Hose, Mounting Bracket, Nozzle2105K4400000000
    6"10PVC13"SteelNo3/8"
    1/2"6Hose, Mounting Bracket, Nozzle2105K4500000000
    8"10PVC14"SteelNo3/8"
    1/2"8Hose, Mounting Bracket, Nozzle2105K4600000000
     

    Static-Dissipative Adjustable-Arm Bench-Top Air Purifiers

    Image of Product. Front orientation. Air Purifiers. Static-Dissipative Adjustable-Arm Bench-Top Air Purifiers.
    Eliminate static buildup while purifying air.
    Cannot Be Sold To—Purifiers cannot be sold to the listed areas due to environmental regulations.
    Overall
    Housing
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Power,
    hp
    Voltage
    Current
    Ht.
    Wd.
    Dp.
    For Max. Surface
    Thk.
    Arm
    Reach
    Material
    Color
    Control Type
    No. of
    Speeds
    Surface Resistivity,
    ohm/sq.
    Cord Lg.,
    ft.
    Includes
    For
    Removing
    Cannot Be
    Sold To
    Each
    10538 dBA @ 15 ft.1/40120V AC0.1 amp8 1/2"8 1/4"4"2 1/2"24"PlasticBlackOn/Off Switch11× 10^96Disposable Odor-Removal FilterOdors, FumesCalifornia4518T480000000
    Replacement Filters

    Swivel-Arm Fume Exhaust Hoses

    Image of Product. Front orientation. Fume Exhaust Hoses. Swivel-Arm Fume Exhaust Hoses.
    For exact positioning, this hose swivels 360° to remove fumes, vapors, and fine dust particles from your space. It's commonly used in welding, soldering, and other operations that create fumes.
    Hose
    Nozzle
    Mounting
    ID
    Lg.,
    ft.
    Material
    Dia.
    Material
    Fasteners
    Included
    For Screw
    Size
    Hole
    Dia.
    Number
    of Holes
    Includes
    Each
    Bench Mount
    3"5PVC5"Powder-Coated AluminumNo1/4"
    3/8"4Hose, Mounting Bracket, Nozzle2105K360000000
     

    Adjustable-Arm Bench-Top Air Purifiers

    Image of Product. Front orientation. Air Purifiers. Adjustable-Arm Bench-Top Air Purifiers.
    Mount these air purifiers to your bench top and adjust the arm to your desired position.
    Cannot Be Sold To—Purifiers cannot be sold to the listed areas due to environmental regulations.
    Overall
    Housing
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Power,
    hp
    Voltage
    Current
    Ht.
    Wd.
    Dp.
    For Max. Surface
    Thk.
    Arm
    Reach
    Material
    Color
    Control Type
    No. of
    Speeds
    Cord Lg.,
    ft.
    Includes
    For
    Removing
    Cannot Be
    Sold To
    Each
    10538 dBA @ 15 ft.1/40120V AC0.14 amp8 1/2"8 1/4"4"2 1/2"24"PlasticWhiteOn/Off Switch16Disposable Odor-Removal FilterOdors, FumesCalifornia4518T470000000
    Replacement Filters

    Adjustable-Length Fume Exhaust Hoses

    Image of Product. Front orientation. Fume Exhaust Hoses. Adjustable-Length Fume Exhaust Hoses.
    The arm length adjusts from 3 to 6 feet making these exhaust hoses good for locations with low ceilings. Use these hoses to remove fumes, vapors, and fine dust particles from your space. They are commonly used in welding, soldering, and other operations that create fumes.
    Hose
    Nozzle
    Mounting
    ID
    Lg.,
    ft.
    Material
    Dia.
    Material
    Fasteners
    Included
    Hole
    Dia.
    Number
    of Holes
    Includes
    Each
    Ceiling Mount
    6 1/4"3 to 6PVC-Coated Nylon11 3/4"Powder-Coated SteelNo1/2"4Hose, Mounting Bracket, Nozzle2105K21000000000
     

    Bench-Top Air Purifiers

    Image of Product. Front orientation. Air Purifiers. Bench-Top Air Purifiers.
    Cannot Be Sold To—Purifiers cannot be sold to the listed areas due to environmental regulations.
    Overall
    Housing
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Power,
    hp
    Voltage
    Current
    Ht.
    Wd.
    Dp.
    Material
    Color
    Control Type
    No. of
    Speeds
    Cord Lg.,
    ft.
    Includes
    For
    Removing
    Cannot Be
    Sold To
    Each
    10538 dBA @ 15 ft.1/40120V AC0.14 amp8 1/2"8 1/4"4"PlasticWhiteOn/Off Switch16Disposable Odor-Removal FilterOdors, FumesCalifornia4518T450000000
    Replacement Filters

    Combination Mobile/Bench-Top Air Purifiers

    Image of Product. In Bench-Top Position. Front orientation. Air Purifiers. Combination Mobile/Bench-Top Air Purifiers.
    Image of Product. In Mobile Position. Front orientation. Air Purifiers. Combination Mobile/Bench-Top Air Purifiers.

    In Bench-Top Position

    In Mobile Position

    Roll this air purifier to the contaminant source or place it on a bench top. Attach the included plastic hood to use as an air purifying booth.
    Includes a prefilter; all other filters sold separately.
    Overall
    Hose
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Power,
    hp
    Voltage
    Current
    For Inlet
    Duct Dia.
    Mobility
    Ht.
    Wd.
    Dp.
    Housing Material
    Control
    Type
    Lg.,
    ft.
    Material
    No. of
    Speeds
    Cord Lg.,
    ft.
    Includes
    For Removing
    Each
    35058 dBA @ 15 ft.1/4120V AC2.8 amp2 1/2"Stationary, Mobile19 1/2"12 1/2"12 1/2"Powder-Coated SteelKnob4PlasticVariable7Disposable Prefilter, Plastic HoodDust, Particles, Odors, Fumes2113K11000000000
    Accessories and Replacements for Air Purifiers

    Floor-Mount Hazardous Location Fume Exhausters

    Image of Product. Front orientation. Fume Exhausters. Floor-Mount Hazardous Location Fume Exhausters.
    This fume exhauster has a motor that is UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G locations. Use it to remove fumes, vapors, and fine dust particles from your space. It is commonly used in welding, soldering, and other operations that create fumes.
    Airflow @ Static Pressure—Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Power,
    hp
    Inlet
    Dia.
    Outlet
    Dia.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Base
    Material
    Wheel
    Material
    Fasteners
    Included
    For Screw
    Size
    Hole
    Dia.
    No. of
    Holes
    Hazardous Location Rating
    Each
     
    120V AC—Hardwire
    800 ft³/min @ 1/2 in. H₂O65 dBC @ 15 ft.1/36"6"15 1/8"18 1/4"20 3/8"Galvanized SteelSteelAluminum
    No1/4"
    9/32"4NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    1951K5000000000
     

    Static-Dissipative Bench-Top Air Purifiers

    Image of Product. Front orientation. Air Purifiers. Static-Dissipative Bench-Top Air Purifiers.
    Eliminate static buildup while purifying air.
    Cannot Be Sold To—Purifiers cannot be sold to the listed areas due to environmental regulations.
    Overall
    Housing
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Power,
    hp
    Voltage
    Current
    Ht.
    Wd.
    Dp.
    Material
    Color
    Control Type
    No. of
    Speeds
    Surface Resistivity,
    ohm/sq.
    Cord Lg.,
    ft.
    Includes
    For
    Removing
    Cannot Be
    Sold To
    Each
    10538 dBA @ 15 ft.1/40120V AC0.1 amp8 1/2"8 1/4"4"PlasticBlackOn/Off Switch11× 10^96Disposable Odor-Removal FilterOdors, FumesCalifornia4518T460000000
    Replacement Filters

    Wall-Mount Fume Exhausters

    Image of Product. Front orientation. Fume Exhausters. Wall-Mount Fume Exhausters.
    Remove fumes, vapors, and fine dust particles from your space. This exhauster is commonly used in welding, soldering, and other operations that create fumes.
    Open Dripproof (ODP) Motor Enclosure—Use open dripproof exhausters in relatively clean, dry, well-ventilated indoor locations.
    Airflow @ Static Pressure—Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Power,
    hp
    Inlet
    Dia.
    Outlet
    Dia.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Base
    Material
    Wheel
    Material
    Fasteners
    Included
    For Screw
    Size
    Hole
    Dia.
    No. of
    Holes
    Each
    Open Dripproof (ODP) Motor Enclosure
     
    120V AC—Hardwire
    300 ft³/min @ 1/2 in. H₂O61 dBC @ 15 ft.1/44"4"16"16"8 7/8"Galvanized SteelSteelSteelNo1/4"
    9/32"41951K30000000
     

    Wall-Mount Hazardous Location Fume Exhausters

    Image of Product. Front orientation. Fume Exhausters. Wall-Mount Hazardous Location Fume Exhausters.
    This fume exhauster has a motor that is UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups E, F, and G locations. Use it to remove fumes, vapors, and fine dust particles from your space. It is commonly used in welding, soldering, and other operations that create fumes.
    Airflow @ Static Pressure—Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Power,
    hp
    Inlet
    Dia.
    Outlet
    Dia.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Base
    Material
    Wheel
    Material
    Fasteners
    Included
    For Screw
    Size
    Hole
    Dia.
    No. of
    Holes
    Hazardous Location Rating
    Each
     
    120V AC—Hardwire
    300 ft³/min @ 1/2 in. H₂O61 dBC @ 15 ft.1/44"4"16"17 5/8"8 7/8"Galvanized SteelSteelAluminum
    No1/4"
    9/32"4NEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups E, F, G
    1951K7000000000
     

    Bench-Top Hood Air Purifiers

    Image of Product. Front orientation. Air Purifiers. Bench-Top Hood Air Purifiers.
    Image of Product. Front orientation. Air Purifier Prefilters.
    Image of Product. Front orientation. Air Purifier Filters.

    Replacement Prefilters

    Replacement Filters

    Filtering away dust and particles, these hoods create a clean space for demanding work, such as bioprocessing, pharmaceuticals, electronics, and optics. They have a HEPA H14 filter to catch 99.995% of particles down to 0.1 microns, as well as a prefilter to pull out large particles before they reach the HEPA filter. To draw air from outside the hood into the filters, they have a fan; there’s no need to connect them to ductwork. A flow monitor tracks the airflow and alerts you with a visible and audible alarm if the fan fails. They meet Fed. Std. Class 100 and ISO Class 5 clean room requirements.
    As an alternative to filtering the air of an entire room, these hoods leave a large enough opening for comfortable access inside and have internal fluorescent lighting to help you see your work. Their work surface is 304L stainless steel, which resists bacteria and chemicals, and also is easy to clean. Mount them on workbenches and carts that are designed to hold them, or place them on your own bench top.
    Purifiers
    Replacement
    Prefilters
    Replacement
    Filters
    Overall
    Work
    Surface
    Housing
    Airflow,
    ft³/min
    Volume (Sound)
    @ Distance
    Voltage,
    V AC
    Current,
    amp
    Ht.
    Wd.
    Dp.
    Wd.
    Dp.
    Material
    Color
    Panel Cutout
    Dia.
    Clean Room Std.
    Each
    Each
    Each
    304L Stainless Steel Work Surface with Acrylic Plastic Enclosure
    18559 dBA @ 5 ft.120347 3/4"31 3/4"24 1/4"26 1/2"20 1/2"PlasticWhite, Black, Blue2 7/8"Fed. Std. Class 100, ISO Class 5
    3944N110000000003944N140000003944N130000000
     
    Carts

    Suspended-Hood Fume Exhausters

    Image of Product. Front orientation. Fume Exhausters. Suspended-Hood Fume Exhausters.
    Position these exhausters above drums, tanks, and distillers to remove fumes, vapors, and fine dust particles from your space. All include a pulley system to adjust the hood height. Add an optional fume exhauster mounting bracket (sold separately) for side-to-side movement.
    Airflow @ Static Pressure—Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Fume Exhausters
    Fume Exhauster
    Mounting Brackets
    Hose
    Hood
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Power,
    hp
    ID
    Lg.,
    ft.
    Includes
    Each
    Each
     
    120V AC—Plug In
    27"500 ft³/min @ 0 in. H₂O60 dB @ 5 ft.1/86"10Blower, Outside Vent Kit21105K21000000021105K750000000
    32"500 ft³/min @ 0 in. H₂O60 dB @ 5 ft.1/86"10Blower, Outside Vent Kit21105K220000000021105K75000000
    37"500 ft³/min @ 0 in. H₂O60 dB @ 5 ft.1/86"10Blower, Outside Vent Kit21105K230000000021105K75000000
    44"500 ft³/min @ 0 in. H₂O60 dB @ 5 ft.1/86"10Blower, Outside Vent Kit21105K240000000021105K76000000
     

    Suspended-Hood Hazardous Location Fume Exhausters

    Image of Product. Front orientation. ZoomedIn view. Fume Exhausters. Suspended-Hood Hazardous Location Fume Exhausters.
    Position these exhausters above drums, tanks, and distillers to remove fumes, vapors, and fine dust particles from your space. All have a motor that is UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Divisions 1 and 2, Groups F and G locations. Exhausters include a pulley system to adjust the hood height. Add an optional fume exhauster mounting bracket (sold separately) for side-to-side movement.
    Airflow @ Static Pressure—Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Fume Exhausters
    Fume Exhauster
    Mounting Brackets
    Hose
    Hood
    Dia.
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Power,
    hp
    ID
    Lg.,
    ft.
    Includes
    Hazardous Location Rating
    Enclosure
    Rating
    Each
    Each
     
    120V AC/230V AC—Hardwire
    27"450 ft³/min @ 0 in. H₂O69 dB @ 5 ft.1/26"10Blower, Outside Vent KitNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    IP54
    21105K4100000000021105K750000000
    32"450 ft³/min @ 0 in. H₂O69 dB @ 5 ft.1/26"10Blower, Outside Vent KitNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    IP54
    21105K420000000021105K75000000
    37"450 ft³/min @ 0 in. H₂O69 dB @ 5 ft.1/26"10Blower, Outside Vent KitNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    IP54
    21105K430000000021105K75000000
    44"450 ft³/min @ 0 in. H₂O69 dB @ 5 ft.1/26"10Blower, Outside Vent KitNEC Class I Divisions 1, 2 Groups C, D
    NEC Class II Divisions 1, 2 Groups F, G
    IP54
    21105K440000000021105K76000000
     

    Portable Fume Exhausters

    Image of Product. Front orientation. Fume Exhausters. Portable Fume Exhausters.
    In addition to using the handle to carry these exhausters, you can mount them to a wall, bench, or floor. They remove fumes, vapors, and fine dust particles from your space. They are commonly used in welding, soldering, and other operations that create fumes. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments. They have a flexible hose with nozzle to capture fumes at the source and rubber pads on the base to reduce vibration.
    Airflow @ Static Pressure—Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Nozzle
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Power,
    hp
    Inlet
    Dia.
    Outlet
    Dia.
    Ht.
    Wd.
    Dp.
    Ht.
    Wd.
    Housing
    Material
    Wheel
    Material
    Fasteners
    Included
    For Screw
    Size
    Hole
    Dia.
    No. of
    Holes
    Hose Lg.,
    ft.
    Each
    Totally Enclosed Motor Enclosure
     
    120V AC, Single Phase—Plug In
    280 ft³/min @ 1 1/2 in. H₂O
    330 ft³/min @ 1/4 in. H₂O
    345 ft³/min @ 0 in. H₂O
    62 dBA @ 15 ft.1/24"4"18 3/4"17 1/2"16"4"8"SteelAluminum
    No3/8"
    7/16"4102111K11000000000
    310 ft³/min @ 1/4 in. H₂O
    335 ft³/min @ 0 in. H₂O
    59 dBA @ 15 ft.1/46"6"17 7/8"13 3/4"18 1/4"8"8"Aluminum
    SteelNo3/8"
    7/16"4102154K1500000000
    575 ft³/min @ 1 1/2 in. H₂O
    655 ft³/min @ 1/4 in. H₂O
    670 ft³/min @ 0 in. H₂O
    59 dBA @ 15 ft.16"6"17 7/8"13 3/4"18 1/4"8"8"Aluminum
    SteelNo3/8"
    7/16"4102154K3200000000
     
    120V AC/230V AC, Single Phase—Hardwire
    730 ft³/min @ 1 1/2 in. H₂O
    795 ft³/min @ 1/4 in. H₂O
    810 ft³/min @ 0 in. H₂O
    73 dBA @ 15 ft.1 1/26"6"21 3/8"21 1/2"16 1/2"8"8"SteelAluminum
    No3/8"
    7/16"4102111K1400000000
     
    230V AC/460V AC, Three Phase—Hardwire
    280 ft³/min @ 1 1/2 in. H₂O
    330 ft³/min @ 1/4 in. H₂O
    345 ft³/min @ 0 in. H₂O
    62 dBA @ 15 ft.1/24"4"18 3/4"17 1/2"16"4"8"SteelAluminum
    No3/8"
    7/16"4102111K1800000000
    575 ft³/min @ 1 1/2 in. H₂O
    655 ft³/min @ 1/4 in. H₂O
    670 ft³/min @ 0 in. H₂O
    59 dBA @ 15 ft.16"6"17 7/8"13 3/4"18 1/4"8"8"Aluminum
    SteelNo3/8"
    7/16"4102154K3300000000
    730 ft³/min @ 1 1/2 in. H₂O
    795 ft³/min @ 1/4 in. H₂O
    810 ft³/min @ 0 in. H₂O
    73 dBA @ 15 ft.1 1/26"6"21 3/8"21 1/2"16 1/2"8"8"SteelAluminum
    No3/8"
    7/16"4102111K1500000000
     
    Duct Kits

    Floor-Mount Fume Exhausters

    Image of Product. Front orientation. Fume Exhausters. Floor-Mount Fume Exhausters, Black Powder-Coated Steel.
    Image of Product. Front orientation. Fume Exhausters. Floor-Mount Fume Exhausters, Aluminum.

    Black Powder-Coated Steel

    Aluminum

    Mount these exhausters to the floor to remove fumes, vapors, and fine dust particles from your space. They are commonly used in welding, soldering, and other operations that create fumes.
    Totally Enclosed Motor Enclosure—Totally enclosed exhausters have an external fan for cooling. These exhausters offer more protection than open dripproof exhausters. They can be used in dirty, dusty, and damp environments, but are not airtight.
    Airflow @ Static Pressure—Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
    Overall
    Mounting
    Airflow @ SP
    Volume (Sound)
    @ Distance
    Power,
    hp
    Inlet
    Dia.
    Outlet
    Dia.
    Ht.
    Wd.
    Dp.
    Housing Material
    Base
    Material
    Wheel
    Material
    Fasteners
    Included
    For Screw
    Size
    Hole
    Dia.
    No. of
    Holes
    Each
    Totally Enclosed Motor Enclosure
     
    120V AC, Single Phase—Plug In
    755 ft³/min @ 1/2 in. H₂O72 dBA @ 15 ft.3/46"5"20 1/4"17"15 3/4"Black Powder-Coated SteelSteelAluminum
    No3/8"
    7/16"41951K113000000000
     
    120V AC/230V AC, Single Phase—Hardwire
    1,045 ft³/min @ 1/2 in. H₂O75 dBA @ 15 ft.1 1/26"6"16 3/8"12 1/4"18"Aluminum
    SteelSteelNo3/8"
    7/16"41951K12600000000
    1,615 ft³/min @ 1/2 in. H₂O72 dBA @ 15 ft.28"8"21 1/2"14 7/8"18 5/8"Aluminum
    SteelSteelNo3/8"
    7/16"41951K12800000000
     
    230V AC, Single Phase—Hardwire
    1,135 ft³/min @ 1/2 in. H₂O78 dBA @ 15 ft.36"6"22 7/8"19 1/8"18 1/4"Black Powder-Coated SteelSteelAluminum
    No3/8"
    7/16"41951K11900000000
     
    230V AC/460V AC, Three Phase—Hardwire
    450 ft³/min @ 1/2 in. H₂O64 dBA @ 15 ft.1/46"6"16 3/8"12 1/4"15 1/4"Aluminum
    SteelSteelNo3/8"
    7/16"41951K12300000000
    855 ft³/min @ 1/2 in. H₂O74 dBA @ 15 ft.1 1/26"6"22 7/8"19 1/8"17 1/8"Black Powder-Coated SteelSteelAluminum
    No3/8"
    7/16"41951K11600000000
    1,135 ft³/min @ 1/2 in. H₂O78 dBA @ 15 ft.36"6"22 7/8"19 1/8"19 7/8"Black Powder-Coated SteelSteelAluminum
    No3/8"
    7/16"41951K12100000000
    1,615 ft³/min @ 1/2 in. H₂O72 dBA @ 15 ft.28"8"21 1/2"14 7/8"18 1/4"Aluminum
    SteelSteelNo3/8"
    7/16"41951K12900000000
     
    Duct Kits
    back to top