About Backflow-Prevention Valves
More
Clamp-On Air Conditioner Service Valves
Tap into refrigerant lines to drain and fill your system. These valves are self-piercing and can be installed without drilling a hole into the line. A valve cap is included.
Style 2 has a removable core to provide unobstructed flow for your refrigerant once the core is removed.
Replacement cores and core kits are sold separately. The kits include a core remover with four valve cores.
Valves | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Valve Port Thread | Core | Replacement Cores | Core Kits | ||||||||||||
Style | For Tube OD | Lg. | Dia. | Type | Gender | Dia. | Material | Body Material | Each | Pkg. Qty. | Pkg. | Each | |||
1 | 1/4", 5/16", 3/8" | 1 3/4" | 1/4" | UN/UNF (SAE 45°) | Male | __ | __ | Zinc | 0000000 | 000000 | __ | 000000 | 00 | 000000 | 00 |
1 | 1/2", 5/8" | 2 1/8" | 1/4" | UN/UNF (SAE 45°) | Male | __ | __ | Zinc | 0000000 | 00000 | __ | 000000 | 00 | 000000 | 00 |
2 | 1/4", 5/16", 3/8" | 1 1/2" | 1/4" | UN/UNF (SAE 45°) | Male | 1/4" | Stainless Steel | Zinc | 0000000 | 00000 | 6 | 0000000 | 00000 | 0000000 | 000000 |
2 | 1/2", 5/8" | 1 13/16" | 1/4" | UN/UNF (SAE 45°) | Male | 1/4" | Stainless Steel | Zinc | 0000000 | 00000 | 6 | 0000000 | 0000 | 0000000 | 00000 |
1/4" SAE Brass Caps (Pkg. of 10) | 0000000 | Pkg. | 000000 |
Solder-On Air Conditioner Service Valves
Tap into refrigerant lines to drain and fill your system. These valves are self-piercing and can be installed without drilling a hole into the line. A valve cap is included.
Valve Port Thread | Core | ||||||||
---|---|---|---|---|---|---|---|---|---|
For Tube OD | Lg. | Dia. | Type | Gender | Dia. | Material | Body Material | Each | |
1/4" | 1 1/2" | 1/4" | UN/UNF (SAE 45°) | Male | 1/4" | Nickel-Plated Brass | Copper | 0000000 | 00000 |
5/16" | 1 1/2" | 1/4" | UN/UNF (SAE 45°) | Male | 1/4" | Nickel-Plated Brass | Copper | 0000000 | 0000 |
3/8" | 1 1/2" | 1/4" | UN/UNF (SAE 45°) | Male | 1/4" | Nickel-Plated Brass | Copper | 0000000 | 00000 |
1/2" | 1 1/2" | 1/4" | UN/UNF (SAE 45°) | Male | 1/4" | Nickel-Plated Brass | Copper | 0000000 | 00000 |
5/8" | 1 1/2" | 1/4" | UN/UNF (SAE 45°) | Male | 1/4" | Nickel-Plated Brass | Copper | 0000000 | 00000 |
3/4" | 1 1/2" | 1/4" | UN/UNF (SAE 45°) | Male | 1/4" | Nickel-Plated Brass | Copper | 0000000 | 00000 |
1/4" SAE Brass Caps (Pkg. of 10) | 0000000 | Pkg. | 000000 |
Deep-Reach Air Conditioner Service Valves
For hard-to-reach spaces, these valves are longer than standard air conditioner service valves. They tap into refrigerant lines to drain and fill your system. All have a removable core to provide unobstructed flow for your refrigerant once the core is removed. A valve cap is included.
Replacement cores and core kits are sold separately. The kits include a core remover with four valve cores.
Valves | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Valve Port Thread | Core | Replacement Cores | Core Kits | ||||||||||||
For Tube OD | Lg. | Dia. | Type | Gender | Dia. | Material | Body Material | Pkg. Qty. | Pkg. | Pkg. Qty. | Pkg. | Each | |||
1/8" | 3" | 1/4" | UN/UNF (SAE 45°) | Male | 1/4" | Nickel-Plated Brass | Brass | 5 | 0000000 | 000000 | 6 | 0000000 | 00000 | 0000000 | 000000 |
1/4" | 2 15/16" | 1/4" | UN/UNF (SAE 45°) | Male | 1/4" | Nickel-Plated Brass | Brass | 5 | 0000000 | 00000 | 6 | 0000000 | 0000 | 0000000 | 00000 |
5/16" | 2 13/16" | 1/4" | UN/UNF (SAE 45°) | Male | 1/4" | Nickel-Plated Brass | Brass | 5 | 0000000 | 00000 | 6 | 0000000 | 0000 | 0000000 | 00000 |
3/8" | 2 13/16" | 1/4" | UN/UNF (SAE 45°) | Male | 1/4" | Nickel-Plated Brass | Brass | 5 | 0000000 | 00000 | 6 | 0000000 | 0000 | 0000000 | 00000 |
1/2" | 2 1/8" | 1/4" | UN/UNF (SAE 45°) | Male | 1/4" | Nickel-Plated Brass | Brass | 3 | 0000000 | 00000 | 6 | 0000000 | 0000 | 0000000 | 00000 |
1/4" SAE Brass Caps (Pkg. of 10) | 0000000 | Pkg. | 000000 |
Check Valves for Refrigerant
- Spring Material: Stainless Steel
- Seal Material: Neoprene Rubber
- Ball Material: Stainless Steel
- For Use With: Refrigerant
Use these valves in refrigeration and air-conditioning systems. All open to allow flow in one direction and close when flow stops or reverses. They solder to copper tubing for a permanent, leak-tight connection.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
For Copper Tube Size | For Tube OD | Flow Coefficient (Cv) | Max. Pressure | Min. Opening Pressure, psi | Temperature Range, °F | End-to-End Lg. | Each | |
Copper Body | ||||||||
---|---|---|---|---|---|---|---|---|
Solder Connect × Solder Connect | ||||||||
1/4 | 3/8" | 1.2 | 755 psi @ 300° F | 1 | -40° to 300° | 3 3/4" | 0000000 | 000000 |
3/8 | 1/2" | 2.2 | 755 psi @ 300° F | 1 | -40° to 300° | 3 3/4" | 0000000 | 00000 |
3/4 | 7/8" | 7.5 | 755 psi @ 300° F | 1 | -40° to 300° | 4 1/2" | 0000000 | 00000 |
1 | 1 1/8" | 12.4 | 755 psi @ 300° F | 1 | -40° to 300° | 5" | 0000000 | 000000 |