McMaster-Carr logo
    Filter by
    Fitting Connection
    Industrial Info Compare
    DFARS Specialty Metals
    Number of Compartments
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Graduated
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Compartment Length
    Compartment Width
    Compartment Capacity
    Autoclavable
    Volume Numeric Increments
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    8 Products

    Syringe Loading Tanks

    Image of Product. Front orientation. Tanks. Syringe Loading Tanks.
    Fill syringes quickly without the mess—these tanks use compressed air to push viscous liquid into a syringe. They hold up to a gallon of material, so you can fill many syringes one after another. To fill a syringe, connect a compressed air source to the tank, twist a syringe onto the dispenser, and slowly turn the ball valve. If you’re using a manually powered syringe, check first to make sure the plunger is fully depressed. For air powered ones, check that the stopper is fully inserted.
    Monitor the tank’s pressure with a built-in gauge. An included regulator works to hold the tank pressure around the recommended 100 psi. If the pressure gets too high, pull the tab on the release valve. To prolong the life of the material in your tank, you should release the pressure after filling your last syringe.
    Cannot Be Sold to Canada—These tanks cannot be sold to Canada due to safety regulations.
    Overall
    Inlet
    Outlet
    Temp.,
    ° F
    Cap.,
    gal.
    Max. Pressure
    @ 100° F, psi
    Dia.
    Ht.
    Opening
    Dia.
    No. of
    Inlets
    Coupling
    Size
    Connection
    Gender
    No. of
    Outlets
    Connection
    Gender
    Min.
    Max.
    Features
    Includes
    Cannot Be
    Sold To
    Each
    Tanks Without Mounting Plate
     
    304 Stainless Steel
    110010"11 1/2"6"11/8Quick DisconnectMale1Luer LockFemale-20100Pressure Gauge, Safety ValveRegulatorCanada5670N1000000000
     

    Reagent Reservoirs

    Hold reagents and samples for easy access during pipetting. These reservoirs have an angled bottom, so you can collect samples even as your liquid starts to run low.
    Rectangle
    Image of Product. Front orientation. Reagent Reservoirs. Reagent Reservoirs, Rectangle.
    Rectangular reservoirs have molded graduation marks to see how much liquid is inside. There’s a pour spout on each corner to discard excess liquid.
    Compartment
    No. of
    Compartments
    Cap.,
    ml
    Lg.
    Wd.
    Volume Numeric
    Increments, ml
    Lg.
    Wd.
    Ht.
    Material
    Color
    Autoclavable
    Features
    Pkg.
    Qty.
    Pkg.
    1103 1/2"1 5/8"104"2"0.875"PolystyreneWhiteNoPour Spout1005766N21000000
    1255 1/2"2"15, 255 7/8"2 1/2"1"PolystyreneWhiteNoPour Spout1005766N2200000
    1505 1/2"2 3/4"5, 10, 25, 506"3 1/2"1 1/8"PolystyreneWhiteNoPour Spout1005766N2300000
    V-Shape
    Image of Product. Side with 1-Chamber. Front orientation. Reagent Reservoirs. Reagent Reservoirs, V-Shape.
    Image of Product. Side with 8- and 12-Chambers. Front orientation. Reagent Reservoirs. Reagent Reservoirs, V-Shape.

    Side with 1-Chamber

    Side with 8- and

    12-Chambers

    V-shape reservoirs have a single large reservoir on one side and 8- and 12-chamber reservoirs on the other. Useful for multi-channel pipettors, the smaller chambers reduce the risk of waste. They’re often used to hold different reagents or ratios and for serial dilutions. Made of polypropylene, they can be autoclaved for reuse.
    Compartment
    No. of
    Cap.
    Lg.
    Wd.
    Ht.
    Lg.
    Wd.
    Ht.
    Material
    Color
    Autoclavable
    Features
    Each
    1
    8
    12
    50 ml
    5 ml
    5 ml
    4 5/8"
    2 1/8"
    2 1/8"
    2 1/8"
    5/16"
    5/16"
    1"
    1"
    1"
    4.75"2.1875"1.0625"Polypropylene
    WhiteYesDouble-Sided5766N100000

    Sterile Reagent Reservoirs

    Image of Product. Front orientation. Reagent Reservoirs. Sterile Reagent Reservoirs.
    To make sure these reservoirs arrive sterile, they've been irradiated, individually bagged, and marked with a lot number. Use them to hold reagents and samples for easy access during pipetting. A V-shaped bottom helps you collect samples as your liquid starts to run low. All have molded graduation marks, so you can gauge how much liquid is inside. There’s a pour spout on each corner for discarding excess liquid. These reservoirs cannot be autoclaved or reused.
    Compartment
    Cap.,
    ml
    Lg.
    Wd.
    Graduated
    Volume Numeric
    Increments, ml
    Lg.
    Wd.
    Ht.
    Material
    Color
    Features
    Autoclavable
    Pkg.
    Qty.
    Pkg.
    Rectangle
    103 1/2"1 5/8"Yes104"2"7/8"PolystyreneWhitePour Spout, SterileNo55807N1100000
    255 1/2"2"Yes15, 255 7/8"2 1/2"1"PolystyreneWhitePour Spout, SterileNo55807N120000
    505 1/2"2 3/4"Yes5, 10, 25, 506"3 1/2"1 1/8"PolystyreneWhitePour Spout, SterileNo55807N130000
     
    back to top