    14 Products

    Flame- and Arc-Flash-Protection Coveralls

    These coveralls meet NFPA 70E standards for protection against electrical arc flashes. Check the personal protection equipment (PPE) category and minimum arc rating provided for your workplace. PPE Category 2 is the most common rating for standard industrial applications, while PPE Category 4 provides the highest level of protection from arc flashes.
    PPE Category 1—Men's Nomex Fabric
    Image of Product. Front orientation. Coveralls. Flame- and Arc-Flash-Protection Coveralls, Men's Clothes.
    Image of Specification. Front orientation. Contains Border. Dark Blue. Flame- and Arc-Flash-Protection Coveralls.

    Dark

    Blue

    Nomex fabric won’t melt or drip if it catches fire. It resists wear and abrasion better than other materials.
    NFPA 2112—NFPA 2112 rated coveralls protect against flash fires.
    Long Length—Long coveralls have added length in the torso, sleeves, and legs, so they are recommended for anyone 6’ 1” and taller.
    Chest Size—When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under the coveralls.
    Arc Rating,
    cal/cm²
    Closure
    Method
    Cuff
    Style
    Flammability
    Rating
    Features
    Color
    Choose a
    Length
    Choose a Size (Chest Size)
    Each
    4.6ZipperSnapsNFPA 70E, NFPA 2112
    Six Pockets, Hip SlitsDark BlueRegular, LongS (36"), S (38"), M (40"), M (42"), L (44"), L (46"), XL (48")1051T60000000
    4.6ZipperSnapsNFPA 70E, NFPA 2112
    Six Pockets, Hip SlitsDark BlueRegular, LongXL (50"), 2XL (52"), 2XL (54")1051T7000000
    PPE Category 2—Men's Cotton Fabric
    Image of Product. Front orientation. Coveralls. Flame- and Arc-Flash-Protection Coveralls, Men's Clothes.
    Image of Product. Back orientation. Coveralls. Flame- and Arc-Flash-Protection Coveralls, Men's Clothes, Kevlar Strap.
    Image of Specification. Front orientation. Contains Border. Dark Blue. Flame- and Arc-Flash-Protection Coveralls.

    Kevlar Strap

    Dark

    Blue

    Cotton fabric is lightweight and provides better breathability than other materials. Coveralls are stitched with Nomex threads for added durability.
    Kevlar Strap—Coveralls with a Kevlar strap help someone rescue you from electrical shock when working with high-voltage equipment. In an emergency, someone can grab the 10 ft. strap to drag you to safety without approaching the hazard themselves. The strap is an alternative to a typical rescue hook or electrical safety hook.
    Long Length—Long coveralls have added length in the torso, sleeves, and legs, so they are recommended for anyone 6’ 1” and taller.
    Chest Size—When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under the coveralls.
    Cannot Be Sold To—Coveralls that cannot be sold to the listed areas are restricted due to PFAS regulations.
    Arc Rating,
    cal/cm²
    Closure
    Method
    Cuff
    Style
    Flammability
    Rating
    Features
    Color
    Cannot Be Sold To
    Choose a
    Length
    Choose a Size (Chest Size)
    Each
    8.2ZipperSnapsNFPA 70E
    Five Pockets, Hip Slits, Nomex ThreadsDark BlueRegular, LongS (38"), M (40"), M (42"), L (44"), L (46"), XL (48"), XL (50"), 2XL (52"), 2XL (54"), 3XL (56")5442T910000000
    12ZipperOpenNFPA 70E
    Kevlar StrapDark BlueCalifornia, Connecticut, Maine, New York, VermontRegularS (36"), M (39"), L (42"), XL (46"), 2XL (50"), 3XL (54")8362N11000000
    PPE Category 2—Men's Aramid/Modacrylic Fabric
    Image of Product. Front orientation. Coveralls. Flame- and Arc-Flash-Protection Coveralls, Men's Clothes.
    Image of Specification. Front orientation. Contains Border. Dark Blue. Flame- and Arc-Flash-Protection Coveralls.

    Dark

    Blue

    Aramid/Modacrylic fabric provides better resistance against arc flashes and is more durable than cotton.
    NFPA 2112—NFPA 2112 rated coveralls protect against flash fires.
    Chest Size—When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under the coveralls.
    Arc Rating,
    cal/cm²
    Closure
    Method
    Cuff
    Style
    Flammability
    Rating
    Features
    Color
    Clothing
    Lg.
    Choose a Size (Chest Size)
    Each
    8ZipperSnapsNFPA 70E, NFPA 2112
    Seven Pockets, Hip SlitsDark BlueRegularM (40"/42"), L (44"/46"), XL (48"/50"), 2XL (52"/54"), 3XL (56"/58"), 4XL (60"/62")5442T190000000
    PPE Category 2—Women's Aramid/Modacrylic Fabric
    Image of Product. Front orientation. Coveralls. Flame- and Arc-Flash-Protection Coveralls, Women's Clothes.
    Image of Specification. Front orientation. Contains Border. Dark Blue. Flame- and Arc-Flash-Protection Coveralls.

    Dark

    Blue

    Aramid/Modacrylic fabric provides better resistance against arc flashes and is more durable than cotton.
    NFPA 2112—NFPA 2112 rated coveralls protect against flash fires.
    Chest Size—When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under the coveralls.
    Arc Rating,
    cal/cm²
    Closure
    Method
    Cuff
    Style
    Flammability
    Rating
    Features
    Color
    Clothing
    Lg.
    Choose a Size (Chest Size)
    Each
    8ZipperSnapsNFPA 70E, NFPA 2112
    Seven PocketsDark BlueRegularS (34"), M (37"), L (40"), XL (43")5220N10000000
    8ZipperSnapsNFPA 70E, NFPA 2112
    Seven PocketsDark BlueRegular2XL (47"), 3XL (50")5220N2000000
    PPE Category 4—Men's Aramid/Modacrylic Fabric
    Image of Product. Front orientation. Coveralls. Flame- and Arc-Flash-Protection Coveralls, Men's Clothes.
    Image of Specification. Front orientation. Contains Border. Dark Blue. Flame- and Arc-Flash-Protection Coveralls.

    Dark

    Blue

    Aramid/Modacrylic fabric provides better resistance against arc flashes and is more durable than cotton.
    Chest Size—When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under the coveralls.
    Arc Rating,
    cal/cm²
    Closure
    Method
    Cuff
    Style
    Flammability Rating
    Color
    Clothing
    Lg.
    Choose a Size (Chest Size)
    Each
    40ZipperKnitNFPA 70E, ASTM F1506
    Dark BlueRegularS (36"), M (38"), L (42"), XL (44"), 2XL (48"), 3XL (52")1956T430000000

    Arc-Flash-Protection Clothing Kits

    Image of Product. Front orientation. Contains MultipleImages. Clothing Kits. Arc-Flash-Protection Clothing Kits, Style B.

    Style B

    For protection from arc flash hazards, these kits include several of the safety items you may need. All items meet NFPA 70E for protection against flames and electrical arc flashes. Choose clothing that meets the arc rated personal protective equipment (PPE) category required by your workplace.
    When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under the protective clothing.
    Style B
    Image of Product. Front orientation. Contains MultipleImages. Clothing Kits. Arc-Flash-Protection Clothing Kits, Style B.
    Style B kits come with coveralls, hard hat, face shield, hood, and two storage bags.
    PPE Category 2—These kits have the most common arc-flash-protection rating for industrial applications.
    Hard Hat
    Face Shield
    Coveralls
    Arc-Rated
    PPE Category
    Arc Rating,
    cal/cm²
    No. of Suspension
    Points
    Material
    Hat
    Size
    Lens
    Material
    Lens
    Ht.
    Lens
    Wd.
    Lens
    Thick.
    Material
    Color
    Includes
    Flammability Rating
    Specs. Met
    Choose a Size (Chest Size)
    Each
    2
    124Polyethylene6 1/2-8Polycarbonate
    12"8"0.09"Cotton/Nylon FabricRed/GrayHard Hat, Hood, Face Shield, Coveralls, Two Storage BagsASTM F1506, NFPA 70E
    ANSI/ISEA Z87.1, ANSI/ISEA Z89.1M (44"), L (48"), XL (52"), 2XL (56"), 3XL (60")2708N20000000

    High-Visibility Flame- and Arc-Flash-Protection Coveralls

    Image of Product. Front orientation. Coveralls. High-Visibility Flame- and Arc-Flash-Protection Coveralls.
    Wear these coveralls for neck-to-ankle protection from electrical arc-flashes and flash fires. They’re bright yellow with reflective strips to help you stand out in busy areas and dim conditions. They meet NFPA 70E and NFPA 2112 standards for protection from arc flashes and flames, as well as ANSI/ISEA 107 standards for visibility. They’re rated Class 3, which means you'll be visible from at least 1/4 of a mile away. Made of a cotton/nylon fabric, these coveralls are soft and wear resistant.
    Check the personal protective equipment (PPE) category and minimum arc rating provided for your workplace and select all required clothing and personal protective equipment to meet that rating. These coveralls are rated for Category 2, the most common arc flash rating for industrial applications.
    S—Size S coveralls have an inseam length of 32".
    M and L—Size M and L coveralls have an inseam length of 33".
    XL and 2XL—Size XL and 2XL coveralls have an inseam length of 34".
    3XL—Size 3XL coveralls have an inseam length of 35".
    Chest Size—When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under the coveralls.
    Cannot Be Sold To—These coveralls cannot be sold to the listed areas due to PFAS regulations.
    Arc-Rated
    PPE Category
    Arc Rating,
    cal/cm²
    ANSI Visibility
    Rating
    Material
    Closure
    Method
    Cuff
    Style
    Flammability
    Rating
    Specs. Met
    Color
    Clothing
    Lg.
    Features
    Cannot Be Sold To
    Choose a Size (Chest Size)
    Each
    Long-Sleeve Coveralls
    2
    10Class 3Cotton/Nylon FabricZipperSnapsNFPA 70E, NFPA 2112
    ANSI/ISEA 107Fluorescent YellowRegularSeven PocketsCalifornia, Connecticut, Maine, New York, VermontS (34"/36"), M (38"/40"), L (42"/44"), XL (46"/48"), 2XL (50"/52"), 3XL (54"/56")8377N110000000
     

    Flame- and Arc-Flash-Protection Rain Suits

    Image of Product. Front orientation. Rain Suits. Flame- and Arc-Flash-Protection Rain Suits.
    Bib overalls have adjustable suspenders to modify the length.
    When measuring chest size, measure around the fullest part of your chest. Find your waist size by measuring just above the top of your hip bone. Take all measurements over any clothing you expect to wear under these suits.
    PVC Coating—These suits feature PVC coating.
    Nomex Fabric—These suits are made of Nomex fabric.
    Snap Closure—Jackets have snaps down the front and a storm flap to keep rain out.
    Hook and Loop Cuff—Sleeves have hook and loop cuffs; tighten to fit your wrist or expand to wear over gloves.
    NFPA 70E—These suits meet NFPA 70E standards for protection against electrical arc flashes for personal protection equipment (PPE) category 2.
    ASTM F2733—They also meet ASTM F2733 standards for protection against flash fires.
    Arc-Rated PPE Category—Check the PPE category and minimum arc rating provided for your workplace, and then select all required clothing and personal protective equipment to meet the minimum arc rating.
    Arc Rating—Arc rating measures a garment’s ability to insulate the wearer from burns; the higher the arc rating, the greater the flame resistance.
    Arc-Rated
    PPE Category
    Arc Rating,
    cal/cm²
    Thk.,
    mil
    Closure
    Method
    Cuff Style
    Flammability Rating
    Color
    Choose a Size (Chest, Waist, Inseam)
    Each
    Suit with Bib Overalls, Detachable Hood, and Jacket
     
    PVC-Coated Nomex Fabric
    2
    1420SnapHook and LoopNFPA 70E, ASTM F2733
    BlueM (50", 46", 29"), L (54", 50", 30"), XL (58", 54", 31"), 2XL (62", 58", 32"), 3XL (66", 62", 32")2843N220000000
     

    Chemical-Resistant and Arc-Flash-Protection Coveralls

    Image of Product. Front orientation. Coveralls. Chemical-Resistant and Arc-Flash-Protection Coveralls.
    Shield your body from chemical and electrical hazards. These coveralls meet NFPA 1992 to resist 70 different chemicals and NFPA 2112 and 70E for protection against flames and arc flashes. Made of nomex fabric, they’re durable and breathable to keep you comfortable. Sealed seams and a flap over the zipper stop chemicals from reaching your skin.
    Check the personal protective equipment (PPE) category and minimum arc rating provided for your workplace and select all required clothing and personal protective equipment to meet that rating. These coveralls are rated Category 2, the most common arc flash rating for industrial applications.
    All coveralls have an inseam length of 31".
    Chest Size—When measuring chest size, measure around the fullest part of your chest. Take all measurements over any clothing you expect to wear under the coveralls.
    Arc-Rated
    PPE Category
    Arc Rating,
    cal/cm²
    Material
    Closure Method
    Cuff Style
    Flammability Rating
    Color
    Clothing
    Lg.
    Choose a Size (Chest Size)
    Each
    Long-Sleeve Coveralls
    2
    9Nomex FabricHook and Loop, ZipperHook and LoopNFPA 70E, NFPA 1992, NFPA 2112BlueRegularM (37"/38"/39"), L (40"/41"/42"), XL (43"/44"/45"/46")8338N101000000000
     

    Flame- and Arc-Flash-Protection Bib Overalls

    Image of Product. Front orientation. Bib Overalls. Flame- and Arc-Flash-Protection Bib Overalls, Cotton/Nylon Fabric.
    Image of Product. Front orientation. Bib Overalls. Flame- and Arc-Flash-Protection Bib Overalls, Aramid/Modacrylic Fabric.

    Cotton/Nylon

    Fabric

    Aramid/Modacrylic

    Fabric

    These overalls meet NFPA 70E for protection against flames and electrical arc flashes. They’re adjustable for a snug fit that shields skin from hazards while keeping you mobile—tighten and loosen the suspenders and secure cuffs around boots with hook and loop straps. Choose a bib overall that meets the arc rated personal protective equipment (PPE) category required by your workplace. The higher the arc rating, the greater the flame resistance.
    Find your waist size by measuring just above the top of your hip bone. Take all measurements over any clothing you expect to wear under these overalls.
    Cotton/Nylon Fabric—Cotton/nylon overalls are rated Category 2 for protection against arc flashes, which is the most common rating for standard industrial applications. They are soft yet wear resistant, so they’re more breathable than modacrylic/aramid overalls. A water-resistant coating on these overalls keeps you dry. They have leg zippers, making it easy to pull the overalls over bulky boots. With hip slits on both sides, you can reach through to your pants pockets.
    Aramid/Modacrylic Fabric—Aramid/Modacrylic overalls are rated Category 4 to provide the highest level of protection from arc flashes. Made from the same material as the outer layer of a firefighter’s jacket, these overalls are extremely durable.
    Arc-Rated
    PPE Category
    Arc Rating,
    cal/cm²
    Material
    Cuff Style
    Features
    Color
    Inseam
    Lg.
    Choose a Size (Waist Size)
    Each
    2
    12Cotton/Nylon FabricHook and Loop, ZipperAdjustable Suspenders, Hip SlitsDark Blue30"S (31"), M (34"), L (37"), XL (40"), 2XL (44"), 3XL (48")1956T6110000000
    4
    40Aramid/Modacrylic FabricHook and LoopAdjustable SuspendersDark Blue30"M (34"), L (37"), XL (40"), 2XL (44")1956T42000000
    back to top