Hazardous Location Large-Area Floodlights

These lights are UL listed for Class I, Division 2, Groups A, B, C, and D for environments where ignitable concentrations of acetylene, hydrogen, ethylene, and propane occur infrequently, such as in the case of an accidental spill or failure of a ventilation system. They can be hardwired to operate on any of the voltages listed. They require a metal halide bulb (sold separately). These floodlights cannot be sold to California due to local energy efficiency regulations.
Lights | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Bulbs | ||||||||||||||
| Voltage | Bulbs Included | No. of Bulbs Required | Max. Wattage per Bulb | Wd. | Ht. | Dp. | For Conduit Trade Size | Thread Type | Gender | Mounting Hardware Included | Cannot Be Sold To | Each | Each | ||
For Blown Tubular BT37 Metal Halide Bulbs | |||||||||||||||
| 120V AC, 208V AC, 240V AC, 277V AC | No | 1 | 400W | 17 1/4" | 16 1/4" | 7 5/8" | 1/2 | NPT | Female | Yes | CA | 14555K3 | 0000000 | 1970K43 | 000000 |
Metal Halide Light Bulbs

Bulb with
E39 Base





Illuminate large warehouses, factories, and arenas with the bright, white light of these metal halide bulbs. Brightness is measured in lumens; the higher the lumens, the brighter the bulb. Color rendering index (CRI) is a measurement on a scale of 0-100 of how accurately the light from a bulb represents an object's true colors; the higher the number, the more natural the colors appear. Any CRI value over 80 will show colors true to life. A bulb’s estimated yearly cost is based on 3 hours of usage per day at $0.11 per kWh.
Bulbs with an EX39 base number will not burst when they fail.
Pulse-start bulbs restart nearly twice as fast as probe-start bulbs.
Plastic-coated glass bulbs are shatter resistant; the coating retains glass shards if they break.
Bulbs that cannot be sold to the listed areas exceed local regulatory limits on mercury content.
| Wattage | Light Appearance | Brightness, lumens | Bulb Shape No. | Operating Position | CRI | For Ballast ANSI No. | Start Type | Bulb Material | Rated Life, hrs. | Est. Yearly Energy Cost, $ | Bulb Dia. | O'all Lg. | Specifications Met | Cannot Be Sold To | Each | |
For Enclosed Fixtures | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cone Bulb—E26 Medium (Standard Household) Base (1 1/16" Dia.) | ||||||||||||||||
| 50W | Warm (3,000K) | 3,450 | E17 | Base Up, Base Down, Horizontal | 70 | M110 | Pulse | Glass | 20,000 | 6.02 | 2 1/8" | 5 7/16" | __ | Canada | 8293K21 | 000000 |
| 70W | Warm (3,000K) | 5,200 | E17 | Base Up, Base Down, Horizontal | 75 | M98 | Pulse | Glass | 15,000 | 8.43 | 2 1/8" | 5 7/16" | __ | Canada | 8293K23 | 00000 |
| 150W | Neutral (3,700K) | 12,500 | BD17 | Base Up, Base Down, Horizontal | 65 | M107 | Probe | Glass | 10,000 | 18.07 | 2 1/8" | 5 7/16" | __ | Canada | 8293K27 | 00000 |
| 150W | Warm (3,000K) | 12,900 | E17 | Base Up, Base Down, Horizontal | 75 | M102 | Probe | Glass | 15,000 | 18.07 | 2 1/8" | 5 7/16" | __ | Canada | 8352K51 | 00000 |
| 175W | Neutral (3,600K) | 13,000 | E17 | Base Up, Base Down, Horizontal | 70 | M57 | Probe | Glass | 10,000 | 21.08 | 2 1/8" | 5 7/16" | __ | Canada | 8293K28 | 00000 |
| 175W | Neutral (4,000K) | 14,400 | ED17 | Base Up, Base Down, Horizontal | 65 | M57 | Probe | Glass | 10,000 | 21.08 | 2 1/8" | 5 7/16" | __ | Canada | 8293K29 | 00000 |
Cone Bulb—E26 Medium (Standard Household) Base (1 1/4" Dia.) | ||||||||||||||||
| 100W | Cool (4,200K) | 9,000 | ED17 | Base Up, Base Down, Horizontal | 65 | M90, M140 | Pulse | Glass | 15,000 | 20.64 | 2 1/8" | 5 5/16" | __ | __ | 8293K7 | 00000 |
Cone Bulb—E39 Mogul Base (1 9/16" Dia.) | ||||||||||||||||
| 175W | Neutral (3,800K) | 14,000 | ED28 | Base Up, Base Down, Horizontal | 70 | M57 | Probe | Glass | 10,000 | 21.08 | 3 1/2" | 8 3/8" | __ | Canada | 8352K75 | 00000 |
| 175W | Cool (4,200K) | 14,400 | ED28 | Base Up, Base Down, Horizontal | 65 | M57 | Probe | Glass | 10,000 | 21.08 | 3 1/2" | 8 3/8" | __ | Canada | 8352K61 | 00000 |
| 250W | Neutral (3,800K) | 21,000 | ED28 | Base Up, Base Down, Horizontal | 65 | M138, M153 | Pulse | Glass | 15,000 | 30.11 | 3 1/2" | 8 3/8" | __ | Canada | 1970K27 | 00000 |
| 250W | Neutral (3,800K) | 21,500 | ED28 | Base Up, Base Down, Horizontal | 70 | M58 | Probe | Glass | 10,000 | 30.11 | 3 1/2" | 8 3/8" | __ | Canada | 8352K76 | 00000 |
| 250W | Neutral (4,000K) | 13,700 | ED28 | Base Up, Base Down, Horizontal | 65 | M58 | Probe | Plastic-Coated Glass | 10,000 | 30.11 | 3 1/2" | 8 3/8" | NSF/ANSI 2 | Canada | 8144K23 | 00000 |
| 250W | Cool (4,200K) | 22,000 | ED28 | Base Up, Base Down, Horizontal | 65 | M58 | Probe | Glass | 10,000 | 30.11 | 3 1/2" | 8 3/8" | __ | Canada | 8352K62 | 00000 |
| 250W | Cool (4,200K) | 23,000 | ED28 | Base Up | 65 | M138, M153 | Pulse | Glass | 20,000 | 30.11 | 3 1/2" | 8 3/8" | __ | Canada | 1970K26 | 00000 |
| 320W | Cool (4,100K) | 30,000 | ED28 | Base Up, Base Down, Horizontal | 62 | M132, M154 | Pulse | Glass | 20,000 | 38.54 | 3 1/2" | 8 3/8" | __ | Canada | 1970K11 | 00000 |
| 350W 400W | Neutral (4,000K) | 44,000 | ED37 | Base Up, Base Down, Horizontal | 68 | M131, M135, M155 | Pulse | Glass | 30,000 | 42.16 48.18 | 4 5/8" | 11 1/2" | __ | __ | 1970K43 | 00000 |
| 360W | Neutral (4,000K) | 36,000 | ED37 | Base Up | 65 | M59, M165 | Probe | Glass | 20,000 | 43.36 | 4 5/8" | 11 1/2" | __ | Canada | 8352K12 | 00000 |
| 400W | Neutral (3,600K) | 36,000 | ED28 | Base Up, Base Down, Horizontal | 70 | M59 | Probe | Glass | 20,000 | 48.18 | 3 1/2" | 8 3/8" | __ | Canada | 8352K13 | 00000 |
| 400W | Neutral (3,700K) | 36,000 | ED37 | Base Up, Base Down, Horizontal | 70 | M59 | Probe | Glass | 20,000 | 48.18 | 4 5/8" | 11 1/2" | __ | Canada | 8352K77 | 00000 |
| 400W | Neutral (4,000K) | 36,000 | ED18 | Base Up, Base Down, Horizontal | 65 | M59 | Probe | Glass | 20,000 | 48.18 | 2 1/4" | 9 3/4" | __ | Canada | 8352K79 | 00000 |
| 400W | Neutral (4,000K) | 36,000 | ED28 | Base Up, Base Down, Horizontal | 65 | M59 | Probe | Glass | 20,000 | 48.18 | 3 1/2" | 8 3/8" | __ | Canada | 8352K72 | 00000 |
| 400W | Neutral (4,000K) | 36,000 | ED37 | Base Up, Base Down, Horizontal | 65 | M59 | Probe | Glass | 20,000 | 48.18 | 4 5/8" | 11 1/2" | __ | Canada | 8352K63 | 00000 |
| 400W | Neutral (4,000K) | 36,000 | ED37 | Base Up, Base Down, Horizontal | 65 | M135, M155 | Pulse | Glass | 20,000 | 48.18 | 4 5/8" | 11 1/2" | __ | Canada | 1970K28 | 00000 |
| 400W | Neutral (4,000K) | 40,000 | ED28 | Base Up, Base Down, Horizontal | 65 | M155 | Pulse | Glass | 20,000 | 48.18 | 3 1/2" | 8 3/8" | __ | Canada | 8352K52 | 00000 |
| 400W | Neutral (4,000K) | 42,000 | ED37 | Base Up | 65 | M59 | Probe | Glass | 20,000 | 48.18 | 4 5/8" | 11 1/2" | __ | Canada | 8352K73 | 00000 |
| 400W | Neutral (4,000K) | 42,000 | ED37 | Base Up | 65 | M135, M155 | Pulse | Glass | 20,000 | 48.18 | 4 5/8" | 11 1/2" | __ | Canada | 1970K24 | 00000 |
Tubular Bulb—E39 Mogul Base (1 9/16" Dia.) | ||||||||||||||||
| 400W | Neutral (4,000K) | 36,000 | T15 | Base Up, Base Down, Horizontal | 65 | M59 | Probe | Glass | 20,000 | 48.18 | 1 7/8" | 11 1/2" | __ | __ | 8352K43 | 00000 |
Blown Tubular Bulb—E39 Mogul Base (1 9/16" Dia.) | ||||||||||||||||
| 750W | Neutral (4,000K) | 78,000 | BT37 | Base Up | 65 | M149 | Pulse | Glass | 20,000 | 90.34 | 4 5/8" | 11 1/2" | __ | Canada | 1970K17 | 00000 |
| 1,000W | Neutral (3,400K) | 107,000 | BT56 | Base Up, Base Down, Horizontal | 70 | M47 | Probe | Glass | 18,000 | 120.45 | 7" | 15 3/8" | __ | Canada | 8352K26 | 00000 |
| 1,000W | Neutral (3,800K) | 110,000 | BT37 | Base Up, Base Down, Horizontal | 65 | M47 | Probe | Glass | 15,000 | 120.45 | 4 5/8" | 11 1/2" | __ | Canada | 8352K19 | 00000 |
| 1,000W | Neutral (3,800K) | 110,000 | BT37 | Base Up, Base Down, Horizontal | 65 | M141 | Pulse | Glass | 15,000 | 120.45 | 4 5/8" | 11 1/2" | __ | Canada | 1970K18 | 00000 |
| 1,000W | Neutral (4,000K) | 110,000 | BT56 | Base Up, Base Down, Horizontal | 65 | M47 | Probe | Glass | 18,000 | 120.45 | 7" | 15 3/8" | __ | Canada | 8352K64 | 00000 |
| 1,500W | Neutral (4,000K) | 170,000 | BT56 | Base Up | 70 | M48 | Probe | Glass | 3,000 | 180.68 | 7" | 15 3/8" | __ | Canada | 8352K65 | 00000 |
For Open Fixtures, Enclosed Fixtures | ||||||||||||||||
Cone Bulb—EX39 Mogul Base (1 9/16" Dia.) | ||||||||||||||||
| 320W | Neutral (4,000K) | 28,000 | ED28 | Base Up, Base Down, Horizontal | 68 | M132, M154 | Pulse | Glass | 15,000 | 38.54 | 3 1/2" | 8 3/8" | __ | __ | 1970K81 | 00000 |
| 400W | Cool (5,000K) | 30,500 | ED37 | Base Up | 90 | M135, M155 | Pulse | Glass | 30,000 | 48.18 | 4 5/8" | 11 1/2" | __ | __ | 8469K7 | 00000 |
Blown Tubular Bulb—EX39 Mogul Base (1 9/16" Dia.) | ||||||||||||||||
| 175W | Neutral (4,000K) | 14,400 | BT28 | Base Up | 65 | M57 | Probe | Glass | 10,000 | 21.08 | 3 1/2" | 8 3/8" | __ | Canada | 8352K27 | 00000 |
| 250W | Neutral (4,000K) | 23,000 | BT28 | Base Up | 65 | M58 | Probe | Glass | 10,000 | 30.11 | 3 1/2" | 8 3/8" | __ | Canada | 8352K29 | 00000 |
| 400W | Neutral (3,400K) | 38,500 | BT37 | Base Up | 70 | M59 | Probe | Glass | 20,000 | 48.18 | 4 5/8" | 11 1/2" | __ | Canada | 8352K37 | 00000 |
| 400W | Neutral (3,600K) | 40,000 | BT37 | Base Up | 65 | M59 | Probe | Glass | 20,000 | 48.18 | 4 5/8" | 11 1/2" | __ | Canada | 8352K36 | 00000 |
| 1,000W | Neutral (3,200K) | 102,000 | BT56 | Base Up | 70 | M47 | Probe | Glass | 15,000 | 120.45 | 7" | 15 3/8" | __ | Canada | 8352K39 | 00000 |
| 1,000W | Neutral (3,500K) | 109,000 | BT56 | Base Up | 65 | M47 | Probe | Glass | 15,000 | 120.45 | 7" | 15 3/8" | __ | Canada | 8352K38 | 00000 |