    Adjustable-Blade Wall-Mount Louvers

    Image of Product. Front orientation. Louvers. Adjustable-Blade Wall-Mount Louvers.
    These gravity-operated louvers remain open only when air flows, preventing backdrafts.
    Surface Mount
    Image of Specification. Side1 orientation. Surface Mount.

    Surface

    Mount

    304 Stainless Steel Frame—304 stainless steel louvers resist corrosion, so they won’t rust in harsh environments.
    For
    Opening
    Overall
    Mounting
    Wd.
    Ht.
    Wd.
    Ht.
    Dp.
    Blade
    Thk.
    No. of
    Panels
    For Max. Air
    Velocity, fpm
    Temp. Range,
    ° F
    Fasteners
    Included
    Hole
    Dia.
    Each
    Galvanized Steel Frame and Aluminum Blades
    10 1/2"10 1/2"13"13"2 1/2"0.017"12,500-40 to 180No9/32"00000000000000
    12 1/2"12 1/2"15"15"2 1/2"0.017"12,500-40 to 180No9/32"0000000000000
    14 1/2"14 1/2"17"17"2 1/2"0.017"12,500-40 to 180No9/32"0000000000000
    16 1/2"16 1/2"19"19"2 1/2"0.017"12,500-40 to 180No9/32"0000000000000
    18 1/2"18 1/2"21"21"2 1/2"0.017"12,500-40 to 180No9/32"0000000000000
    20 1/2"20 1/2"23"23"2 1/2"0.017"12,500-40 to 180No9/32"0000000000000
    22 1/2"22 1/2"25"25"2 1/2"0.017"12,500-40 to 180No9/32"00000000000000
    24 1/2"24 1/2"27"27"3"0.017"12,500-40 to 180No9/32"00000000000000
    24 1/2"36 1/2"27"39"3"0.017"12,500-40 to 180No9/32"00000000000000
    26 1/2"26 1/2"29"29"3"0.017"12,500-40 to 180No9/32"00000000000000
    28 1/2"28 1/2"31"31"3"0.017"12,500-40 to 180No9/32"00000000000000
    30 1/2"30 1/2"33"33"3"0.017"12,500-40 to 180No9/32"00000000000000
    32 1/2"32 1/2"35"35"3"0.017"12,500-40 to 180No9/32"00000000000000
    34 1/2"34 1/2"37"37"3"0.017"12,500-40 to 180No9/32"00000000000000
    36 1/2"36 1/2"39"39"3"0.017"12,500-40 to 180No9/32"00000000000000
    38 1/2"38 1/2"41"41"3"0.017"22,500-40 to 180No9/32"00000000000000
    40 1/2"40 1/2"43"43"3"0.017"22,500-40 to 180No9/32"00000000000000
    42 1/2"42 1/2"45"45"3"0.017"22,500-40 to 180No9/32"00000000000000
    44 1/2"44 1/2"47"47"3"0.017"22,500-40 to 180No9/32"00000000000000
    48 1/2"48 1/2"51"51"3"0.017"22,500-40 to 180No9/32"00000000000000
    50 1/2"50 1/2"53"53"3"0.017"22,500-40 to 180No9/32"00000000000000
    54 1/2"54 1/2"57"57"3"0.017"22,500-40 to 180No9/32"00000000000000
    56 1/2"56 1/2"59"59"3"0.017"22,500-40 to 180No9/32"00000000000000
    60 1/2"60 1/2"63"63"3"0.017"22,500-40 to 180No9/32"00000000000000
     
    304 Stainless Steel Frame and Blades
    12"12"15"15"2 3/8"0.019"12,500-20 to 200No1/4"0000000000000
    16"16"19"19"2 3/8"0.019"12,500-20 to 200No1/4"0000000000000
    18"18"21"21"2 3/8"0.019"12,500-20 to 200No1/4"0000000000000
    20"20"23"23"2 3/8"0.019"12,500-20 to 200No1/4"0000000000000
    24"24"27"27"2 3/8"0.019"12,500-20 to 200No1/4"0000000000000
    30"30"33"33"2 3/8"0.019"12,500-20 to 200No1/4"0000000000000
    36"36"39"39"2 3/8"0.019"12,500-20 to 200No1/4"0000000000000
     
    Motor Kits for Louvers with Galvanized Steel Frames

    Fixed- and Adjustable-Blade Wall-Mount Louvers

    Image of Product. Front orientation. Louvers. Fixed- and Adjustable-Blade Wall-Mount Louvers.
    Image of Specification. Side1 orientation. CrossSection view. Contains Annotated, Border, MultipleImages. Adjustable Blade.
    Fixed front blades give you consistent sight lines when viewing these louvers from outside, while hidden rear blades open and close.
    Recessed Mount
    Image of Specification. Side1 orientation. Recessed Mount.

    Recessed

    Mount

    Water Penetration Rating—Water penetration rating is the air velocity at which water will start to pass through the louver. The higher the number, the better protected the louver is from rain.
    Pressure Drop @ Water Penetration Rating—Pressure drop is the amount of pressure lost as air passes through the louver into your system. The lower the pressure drop, the higher the airflow.
    Airflow—Airflow is the volume of air passing through the louver. Your louver should allow the necessary airflow required for your HVAC system.
    For
    Opening
    Overall
    Wd.
    Ht.
    Wd.
    Ht.
    Dp.
    No. of
    Panels
    Water Penetration
    Rating, fpm
    Pressure Drop @ Water
    Penetration Rating, in. H₂O
    Airflow,
    scfm
    For Max. Air
    Velocity, fpm
    Includes
    Certification
    Each
    Aluminum Frame and Blades
    12"13"11 1/2"11 1/2"4"11,2500.171751,250Bird ScreenAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    00000000000000
    14"14"13 1/2"13 1/2"4"11,2500.174381,250Bird ScreenAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    0000000000000
    20"20"19 1/2"19 1/2"4"11,2500.171,0131,250Bird ScreenAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    0000000000000
    24"24"23 1/2"23 1/2"4"11,2500.171,5881,250Bird ScreenAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    0000000000000
    36"36"35 1/2"35 1/2"4"11,2500.174,3501,250Bird ScreenAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    0000000000000
     

    Weather-Resistant Fixed-Blade Wall-Mount Louvers

    Image of Product. Front orientation. Louvers. Weather-Resistant Fixed-Blade Wall-Mount Louvers.
    Designed with blades that drain water down the jambs, these louvers keep water from running down the front of the blades, even in harsh weather. All louvers have a seal of air performance and water penetration from Air Movement and Control Association (AMCA), so they’ve passed rigorous testing to ensure minimal airflow resistance, while preventing light rainfall from entering your duct system.
    Recessed Mount
    Image of Specification. Side1 orientation. Recessed Mount.

    Recessed

    Mount

    Wind-Driven Rain Environments—Wind-driven rain resistant louvers are AMCA Class A, which means they've achieved the highest rating when tested with strong winds and heavy rain.
    Hurricane Environments—Hurricane louvers meet AMCA 540 and 550, so they have passed tests for impact, rain, and wind common in a hurricane.
    Water Penetration Rating—Water penetration rating is the air velocity at which water will start to pass through the louver. The higher the number, the better protected the louver is from rain.
    Pressure Drop @ Water Penetration Rating—Pressure drop is the amount of pressure lost as air passes through the louver into your system. The lower the pressure drop, the higher the airflow.
    Airflow—Airflow is the volume of air passing through the louver. Your louver should allow the necessary airflow required for your HVAC system.
    For
    Opening
    Overall
    Wd.
    Ht.
    Wd.
    Ht.
    Dp.
    Blade
    Thk.
    No. of
    Panels
    Water Penetration
    Rating, fpm
    Pressure Drop @ Water
    Penetration Rating, in. H₂O
    Airflow,
    scfm
    Includes
    Mounting Fasteners
    Included
    Certification
    Specs. Met
    AMCA Louver
    Rating
    Each
    Aluminum Frame and Blades
     
    Rainy Environments
    11 1/2"11 1/2"11"11"4"0.081"11,0250.2287Bird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    00000000000000
    13 1/2"13 1/2"13"13"4"0.081"11,0250.2380Bird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    0000000000000
    19 1/2"19 1/2"19"19"4"0.081"11,0250.21,056Bird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    0000000000000
    23 1/2"23 1/2"23"23"4"0.081"11,0250.21,599Bird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    0000000000000
    35 1/2"35 1/2"35"35"4"0.081"11,0250.24,203Bird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    0000000000000
     
    Wind-Driven Rain Environments
    11 1/2"11 1/2"11"11"4"0.06"11,0790.41324Bird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration, AMCA Certified for Wind-Driven Rain
    AMCA 500-LClass A0000000000000
    13 1/2"13 1/2"13"13"4"0.06"11,0790.41378Bird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration, AMCA Certified for Wind-Driven Rain
    AMCA 500-LClass A0000000000000
    19 1/2"19 1/2"19"19"4"0.06"11,0790.411,026Bird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration, AMCA Certified for Wind-Driven Rain
    AMCA 500-LClass A0000000000000
    23 1/2"23 1/2"23"23"4"0.06"11,0790.411,835Bird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration, AMCA Certified for Wind-Driven Rain
    AMCA 500-LClass A0000000000000
    35 1/2"35 1/2"35"35"4"0.06"11,0790.414,587Bird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration, AMCA Certified for Wind-Driven Rain
    AMCA 500-LClass A0000000000000
     
    Hurricane Environments
    11 1/2"11 1/2"11"11"6"0.081"19460.18303NoAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    AMCA 540, AMCA 5500000000000000
    13 1/2"13 1/2"13"13"6"0.081"19460.18445NoAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    AMCA 540, AMCA 5500000000000000
    19 1/2"19 1/2"19"19"6"0.081"19460.181,032NoAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    AMCA 540, AMCA 5500000000000000
    23 1/2"23 1/2"23"23"6"0.081"19460.181,552NoAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    AMCA 540, AMCA 5500000000000000
    35 1/2"35 1/2"35"35"6"0.081"19460.184,106NoAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    AMCA 540, AMCA 550000000000000000
     
    Flush Mount
    Image of Specification. Side1 orientation. Flush Mount.

    Flush

    Mount

    Storm Shelter Environments—Storm shelter louvers comply with FEMA 361 and International Code Council (ICC) 500 safety standards for storm shelters.
    Water Penetration Rating—Water penetration rating is the air velocity at which water will start to pass through the louver. The higher the number, the better protected the louver is from rain.
    Pressure Drop @ Water Penetration Rating—Pressure drop is the amount of pressure lost as air passes through the louver into your system. The lower the pressure drop, the higher the airflow.
    Airflow—Airflow is the volume of air passing through the louver. Your louver should allow the necessary airflow required for your HVAC system.
    For
    Opening
    Overall
    Wd.
    Ht.
    Wd.
    Ht.
    Dp.
    Blade
    Thk.
    No. of
    Panels
    Water Penetration
    Rating, fpm
    Pressure Drop @ Water
    Penetration Rating, in. H₂O
    Airflow
    Includes
    Mounting Fasteners
    Included
    Certification
    Specs. Met
    Each
    Aluminum Frame and Blades
     
    Storm Shelter Environments
    11 1/2"11 1/2"11"11"5 1/2"0.25"100Not RatedBird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    FEMA 361, ICC 5000000000000000000
    13 1/2"13 1/2"13"13"5 1/2"0.25"100Not RatedBird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    FEMA 361, ICC 500000000000000000
    19 1/2"19 1/2"19"19"5 1/2"0.25"100Not RatedBird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    FEMA 361, ICC 500000000000000000
    23 1/2"23 1/2"23"23"5 1/2"0.25"100Not RatedBird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    FEMA 361, ICC 500000000000000000
    35 1/2"35 1/2"35"35"5 1/2"0.25"100Not RatedBird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration
    FEMA 361, ICC 500000000000000000
     

    Roof-Mount Louvers

    These louvers are gravity operated. The blades open when your roof-mounted exhaust fan goes on and close when it's off, preventing backdrafts. The felt seal on the face of the blades ensures quiet closing and better protection from the weather.
    Also Available: Additional louver sizes. Please select 8061T999 and specify louver dimensions.
    Surface Mount
    Image of Product. Front orientation. Louvers. Roof-Mount Louvers.
    Image of Specification. Side1 orientation. Surface Mount.
    Image of Product. Front orientation. Exhaust Fan Mounts.
    Image of Attribute. Front orientation. CrossSection view. Contains Annotated.

    Surface

    Mount

    Exhaust Fan Mounts

    Exhaust Fan Mounts—Exhaust fan mounts are sold separately. Louvers fit the bottom of the mount and must be secured to the lip of the mount's base with sheet metal screws (not included).
    Louvers
    8" High Exhaust
    Fan Mounts
    12" High Exhaust
    Fan Mounts
    For
    Opening
    Overall
    Wd.
    Ht.
    Wd.
    Lg.
    Blade
    Thk.
    No. of
    Panels
    For Max. Air
    Velocity, fpm
    Temp. Range,
    ° F
    Mounting Fasteners
    Included
    Each
    Inside
    Wd.
    Each
    Inside
    Wd.
    Each
    Galvanized Steel Frame and Aluminum Blades
    13 3/4"13 3/4"13 3/4"13 3/4"0.016"12,000-40 to 180No00000000000014 1/2"0000000000000014 1/2"00000000000000
    15 3/4"15 3/4"15 3/4"15 3/4"0.016"12,000-40 to 180No0000000000016 1/2"000000000000016 1/2"0000000000000
    17 3/4"17 3/4"17 3/4"17 3/4"0.016"12,000-40 to 180No00000000000———019 1/2"0000000000000
    19 3/4"19 3/4"19 3/4"19 3/4"0.016"12,000-40 to 180No00000000000021 1/2"0000000000000———0
    21 3/4"21 3/4"21 3/4"21 3/4"0.016"12,000-40 to 180No000000000000———023 1/2"0000000000000
    23 3/4"23 3/4"23 3/4"23 3/4"0.016"12,000-40 to 180No000000000000———025 1/2"0000000000000
    27 3/4"27 3/4"27 3/4"27 3/4"0.016"12,000-40 to 180No0000000000000———028 1/2"0000000000000
    34 3/4"34 3/4"34 3/4"34 3/4"0.016"12,000-40 to 180No000000000000035 1/2"000000000000035 1/2"0000000000000
    36 3/4"36 3/4"36 3/4"36 3/4"0.016"12,000-40 to 180No0000000000000———037 1/2"0000000000000
     
    Motor Kits for Louvers with Galvanized Steel Frames

    Heavy Duty Adjustable-Blade Wall-Mount Louvers

    Image of Product. Front orientation. Louvers. Heavy Duty Adjustable-Blade Wall-Mount Louvers.
    Constructed with a thick frame and blades, these louvers have a long service life.
    Recessed Mount
    Image of Specification. Side1 orientation. Recessed Mount.

    Recessed

    Mount

    For
    Opening
    Overall
    Wd.
    Ht.
    Wd.
    Ht.
    Dp.
    Blade
    Thk.
    No. of
    Panels
    Mounting Fasteners
    Included
    Each
    Plastic Frame and Blades
    12"12"13 3/4"13 3/4"1 3/4"0.047"1No000000000000000
    12"18"13 3/4"19 3/4"1 3/4"0.047"1No00000000000000
    12"24"13 3/4"25 3/4"1 3/4"0.047"1No00000000000000
    14"24"15 3/4"25 3/4"1 3/4"0.047"1No00000000000000
     