McMaster-Carr logo
    Filter by
    Cold Cranking Amps
    Battery Terminal Configuration
    Battery Cell Type
    Manufacturer Equivalent Number
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Thread Size
    Industrial Info Compare
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Terminal Size
    Industrial Info Compare
    Screw Size
    Industrial Info Compare
    Mounting Hole Center-to-Center
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    29 Products

    Large-Cell Batteries for Starting

    Image of Product. Front orientation. Batteries. Large-Cell Batteries for Starting.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Tab-Post-Terminal Battery Connection.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Stud-Terminal Battery Connection.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Post-and-Side-Socket Terminal Battery Connection.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Post-Terminal Battery Connection.

    Tab-Post-Terminal

    Battery Connection

    Stud-Terminal

    Battery

    Connection

    Post-and-Side-Socket

    Terminal Battery

    Connection

    Post-Terminal

    Battery

    Connection

    Image of Specification. Front orientation. A.
    Image of Specification. Front orientation. C.
    Image of Specification. Front orientation. D.
    Image of Specification. Front orientation. E.

    A

    C

    D

    E

    Deliver a surge of power to start automobiles and other vehicles. These wet-cell batteries contain electrolyte in an unsealed container, so they must be mounted upright. They may occasionally need to be filled with distilled water.
    Cold cranking amps is the maximum amps that a new, fully charged battery can continuously deliver for 30 seconds at 0° F.
    Warning: Batteries should always be charged and discharged in a ventilated area.
    Voltage,
    V DC
    Battery
    Size
    Battery Terminal
    Configuration
    Cold Cranking
    Amps
    Thread Size
    Ht.
    Wd.
    Dp.
    Each
    Wet Cell Lead Acid
     
    Tab-Post-Terminal Battery Connection
    12U1C3007.3"7.8"5.2"7238K57000000
     
    Stud-Terminal Battery Connection
    1231D9255/16"-18 (Negative Terminal), 3/8"-16 (Positive Terminal)9.4"13"6.8"7238K85000000
     
    Post-and-Side-Socket Terminal Battery Connection
    1234/78D8008.1"10.2"6.9"7597K13000000
    1275DTD6308.1"9.4"6.9"7597K12000000
     
    Post-Terminal Battery Connection
    61A6258.6"8.8"6.8"7238K17000000
    1224C6009.1"10.6"6.8"7238K67000000
    128DE1,30010"20.8"11"7238K64000000
     

    Sealed Large-Cell Batteries for Starting and Continuous Use

    Image of Product. Front orientation. Batteries. Sealed Large-Cell Batteries for Starting and Continuous Use.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Tab-Post-Terminal Battery Connection.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Stud-Terminal Battery Connection.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Post-and-Stud Terminal Battery Connection.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Offset-Tab Post Terminal Battery Connection.

    Tab-Post-Terminal

    Battery Connection

    Stud-Terminal

    Battery

    Connection

    Post-and-Stud

    Terminal

    Battery

    Connection

    Offset-Tab Post

    Terminal

    Battery

    Connection

    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Post-and-Side-Socket Terminal Battery Connection.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Post-Terminal Battery Connection.
    Image of Specification. Front orientation. A.
    Image of Specification. Front orientation. B.

    Post-and-Side-Socket

    Terminal Battery

    Connection

    Post-Terminal

    Battery

    Connection

    A

    B

    Image of Specification. Front orientation. C.
    Image of Specification. Front orientation. D.
    Image of Specification. Front orientation. E.

    C

    D

    E

    Deliver a surge of power to start automobiles and other vehicles, and provide power over a long time. These batteries are deep cycle, so they can handle many charge/deep discharge cycles. All are dry cell, so they have an absorbed glass mat (AGM) that soaks up the electrolyte and can be used in any position except upside down. They can be recharged hundreds of times.
    Reserve capacity is the number of minutes that a new, fully charged battery can continuously discharge at 25 amps at 80° F. Marine cranking amps is the maximum amps that a new, fully charged battery can continuously deliver for 30 seconds at 32° F.
    Warning: Batteries should always be charged and discharged in a ventilated area.
    Voltage,
    V DC
    Battery
    Size
    Mfr. Equiv.
    No.
    Battery
    Cap., A·h
    Battery Terminal
    Configuration
    Reserve
    Cap., min.
    Marine Cranking
    Amps
    Thread
    Size
    Ht.
    Wd.
    Dp.
    Each
    Dry-Cell AGM Lead Acid
     
    Tab-Post-Terminal Battery Connection
    12U132C452407.3"8.3"5.1"71805K110000000
     
    Stud-Terminal Battery Connection
    1231100D1901,0503/8"-16
    9.5"13"6.8"71805K42000000
     
    Post-and-Stud Terminal Battery Connection
    6GC2190A3809005/16"-18
    10.9"10.3"7.1"71805K18000000
    122727M92C1759005/16"-18
    9.9"12.8"6.8"71805K14000000
    122424M79C1358005/16"-18
    9.9"10.9"6.8"71805K13000000
    123131M105D2001,0005/16"-18
    9.4"12.9"6.8"71805K15000000
     
    Offset-Tab Post Terminal Battery Connection
    1222NF55B854209.3"9.4"5.5"71805K12000000
     
    Post-and-Side-Socket Terminal Battery Connection
    1234/7855C1209558"10.8"6.9"71805K41000000
     
    Post-Terminal Battery Connection
    124D198E3801,42010"20.8"8.5"71805K16000000
    128D245E4801,80010"20.8"11"71805K17000000
    126575C1509557.6"12"7.4"71805K43000000
     

    Large-Cell Batteries for Starting and Continuous Use

    Image of Product. Front orientation. Batteries. Large-Cell Batteries for Starting and Continuous Use.
    Image of Specification. Front orientation. ZoomedIn view. Contains Border. Post-and-Stud Terminal Battery Connection.

    Post-and-Stud

    Terminal

    Battery

    Connection

    Image of Specification. Front orientation. C.

    C

    These dual-purpose batteries provide a surge of power to start automobiles and other vehicles, and they deliver power over a long period of time. They're deep cycle, so they can handle many charge/deep discharge cycles. Because they are wet-cell batteries and contain electrolyte in an unsealed container, they must be mounted upright. They may occasionally need to be filled with distilled water.
    Reserve capacity is the number of minutes that a new, fully charged battery can continuously discharge at 25 amps at 80° F. Marine cranking amps is the maximum amps that a new, fully charged battery can continuously deliver for 30 seconds at 32° F.
    Warning: Batteries should always be charged and discharged in a ventilated area.
    Voltage,
    V DC
    Battery
    Size
    Mfr. Equiv.
    No.
    Battery
    Cap., A·h
    Battery Terminal
    Configuration
    Reserve
    Cap., min.
    Marine Cranking
    Amps
    Thread
    Size
    Ht.
    Wd.
    Dp.
    Each
    Wet Cell Lead Acid
     
    Post-and-Stud Terminal Battery Connection
    122727M100C1607305/16"-18
    9.4"12"6.8"71805K830000000
    122424M70C1206255/16"-18
    9.4"10.3"6.8"71805K82000000
     

    Large-Cell Batteries for Continuous Use

    Image of Product. Front orientation. Batteries. Large-Cell Batteries for Continuous Use, Offset-Stud-Terminal Battery Connection.
    Image of Product. Front orientation. Batteries. Large-Cell Batteries for Continuous Use, Stud-Terminal Inside Post Battery Connection.

    Offset-Stud-Terminal

    Battery Connection

    Stud-Terminal Inside Post

    Battery Connection

    Image of Specification. Front orientation. A.
    Image of Specification. Front orientation. D.

    A

    D

    For use in floor-cleaning machines, lift trucks, personnel carriers, and other vehicles that require power over an extended time, these deep-cycle batteries can handle many charge/deep-discharge cycles. They are wet cell, so they contain electrolyte in an unsealed container and must be mounted upright. They may occasionally need to be filled with distilled water.
    Reserve capacity is the number of minutes that a new, fully charged battery can continuously discharge at 25 amps at 80° F. Marine cranking amps is the maximum amps that a new, fully charged battery can continuously deliver for 30 seconds at 32° F.
    Warning: Batteries should always be charged and discharged in a ventilated area.
    Voltage,
    V DC
    Battery
    Size
    Mfr. Equiv.
    No.
    Battery
    Cap., A·h
    Battery Terminal
    Configuration
    Reserve
    Cap., min.
    Marine Cranking
    Amps
    Thread Size
    Ht.
    Wd.
    Dp.
    Each
    Wet Cell Lead Acid
     
    Offset-Stud-Terminal Battery Connection
    6GC2215A3955/16"-18
    10.88"10.25"7.13"71805K970000000
     
    Stud-Terminal Inside Post Battery Connection
    123131M115D2059005/16"-18 (Negative Terminal), 3/8"-16 (Positive Terminal)9.4"13"6.8"71805K94000000
     

    Sealed Large-Cell Batteries for Starting

    Image of Product. Front orientation. Batteries. Sealed Large-Cell Batteries for Starting.
    Image of Specification. Front orientation. Contains Border. Box-Tab Terminal with Two Openings Battery Connection.

    Box-Tab

    Terminal with

    Two Openings

    Battery

    Connection

    Image of Specification. Front orientation. B.

    B

    Start automobiles and other vehicles with a surge of power. These dry-cell batteries have an absorbed glass mat (AGM) that soaks up the electrolyte, so they’re usable in any position except upside down. They can be recharged hundreds of times.
    Cold cranking amps is the maximum amps that a new, fully charged battery can continuously deliver for 30 seconds at 0° F.
    Warning: Batteries should always be charged and discharged in a ventilated area.
    Voltage,
    V DC
    Battery
    Size
    Battery Terminal
    Configuration
    Cold Cranking
    Amps
    Ht.
    Wd.
    Dp.
    Each
    Dry-Cell AGM Lead Acid
     
    Box-Tab Terminal with Two Openings Battery Connection
    12Y50-N18L-AB3406.4"8.1"3.6"7238K120000000
     

    Floor Locks

    Image of ProductInUse. Front orientation. Contains Annotated, Border. Floor Locks. Floor Locks.
    Stabilize carts, trucks, workbenches, and other mobile equipment during loading and unloading. Floor locks bolt or weld to the underside of your equipment and have a spring-loaded base with a nonskid floor pad to keep equipment stationary.
    Note: Floor locks are not load rated. They are designed to brake your equipment in place, not lift it off the floor.
    Top Brake Retraction Pedal
    Image of Product. Front orientation. Floor Locks. Floor Locks, Top Brake Retraction Pedal.
    Image of Attribute. Front orientation. Contains Annotated.
    Image of Attribute. Front orientation. Contains Annotated.
    Image of Attribute. Mounting Plate Style 2. Front orientation. Contains Annotated. Mounting Plate Style 2. Floor Locks.

    Mounting Plate Style 2

    Ht.
    Mounting
    Plate
    Mounting Hole
    Ctr.-to-Ctr.
    For Caster
    Mount Ht.
    Extended
    Retracted
    Clearance
    Style
    Lg.
    Wd.
    Lg.
    Wd.
    Mounting Fasteners
    Included
    For Screw
    Size
    Color
    Each
    Painted Steel
    5" to 7"7 1/4"3 3/8"3 7/8"24"4"2 5/8"2 3/8"No3/8"
    Black2675T110000000
     

    Battery Shunts

    Image of Product. Front orientation. Shunts.
    Connect these shunts to a battery and a panel meter or electrical testing device to measure the current flowing through a circuit when the current is too high to be measured directly by a meter.
    Note: For continuous operation, do not run shunts at more than two-thirds (66%) the rated current.
    Mounting Holes
    Current,
    amp
    Full Scale
    Voltage Drop, mV DC
    Load
    Type
    Wire Connection
    Ht.
    Wd.
    Dp.
    No.
    of
    Dia.
    Ctr.-to-Ctr.
    Mounting Fasteners
    Included
    Each
    5050Resistive1/4" Stud Terminals, No. 8 Screw Terminals1.53"2.01"1.26"20.2"0.87"No2000N11000000
    10050Resistive1/4" Stud Terminals, No. 8 Screw Terminals1.53"2.01"1.26"20.2"0.87"No2000N1200000
    15050Resistive1/4" Stud Terminals, No. 8 Screw Terminals1.53"2.01"1.26"20.2"0.87"No2000N1300000
    20050Resistive3/8" Stud Terminals, No. 8 Screw Terminals1.69"3.27"1.77"20.2"1.26"No2000N1400000
    50050Resistive3/8" Stud Terminals, No. 8 Screw Terminals1.69"3.27"1.77"20.2"1.26"No2000N1500000
    back to top