Barometric Pressure | Overall | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Range | Accuracy | Graduations | Digit Ht. | Dia. | Dp. | Ht. | Wd. | Dp. | Mount Type | Mounting Location | Batteries Included | Mounting Hole Dia. (No. of) | Fasteners Included | Certificate Type | Each | |||
Dial Display | ||||||||||||||||||
| 28.1 in. Hg to 31.7 in. Hg 715 mm Hg to 805 mm Hg 954 mbar to 1,073 mbar | ±0.05 in. Hg ±0.05 mm Hg ±0.05 mbar | 0.05 in. Hg 1 mm Hg 0.5 mbar | — | 4" | 1 1/4" | — | — | — | Freestanding | Wall | — | 3/8" (1) | No | Calibration Certificate Traceable to NIST | 4109K101 | 0000000 | ||
LCD Display with Audible Alarm and Trend Indicator | ||||||||||||||||||
| 20 in. Hg to 32 in. Hg 509 mm Hg to 812 mm Hg 677 mbar to 1,083 mbar | ±0.045 in. Hg ±1.14 mm Hg ±1.5 mbar | — | 1 1/2" | — | — | 2 7/8" | 9" | 1 1/2" | Freestanding | Wall | Yes | 1" (1) | No | — | 4109K5 | 000000 | ||
Desktop Multifunction Barometers
Barometric Pressure | Altitude Measuring Range, ft. | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | Max. Transmission Distance, ft. | Range | Accuracy | Min. | Max. | Weather Features | No. of Readings | Ht. | Wd. | Dp. | Data Connection | Battery Size (No. Req.) | Batteries Included | Mounting Hole Dia. (No. of) | Fasteners Included | Each | |||
Remote-Reading Barometers with LCD Display | |||||||||||||||||||
| A | 200 | 31.15 in. Hg to 32 in. Hg | ±0.15 in. Hg | — | — | Audible Alarm, Clock, Trend Indicator | — | 4 1/4" | 6 1/4" | 1 1/4" | — | AA (4), AA (2) | No | 5/16" (1) | No | 3964K61 | 000000 | ||
Direct-Reading Barometers with LCD Display and Calibration Certificate Traceable to NIST | |||||||||||||||||||
| B | — | 14.5 in. Hg to 30 in. Hg | ±0.12 in. Hg | — | — | Audible Alarm, Clock, Trend Indicator | — | 4" | 3" | 1" | — | AA (3) | Yes | 3/8" (1) | No | 3964K11 | 000000 | ||
| C | — | 500 mbar to 1,030 mbar | ±4 mbar | -320 | 8,200 | Audible Alarm, Clock, Trend Indicator | 525,600 | 5 1/2" | 3 1/4" | 1" | USB-A | AAA (3) | Yes | 3/8" (1) | No | 3964K12 | 000000 | ||