Safety Cabinets for Vertical Storage of Flammables in 55-Gallon Drums


Rollers inside the cabinet make contents easy to load and remove. An adjustable shelf provides space for 5-gallon cans. The door sill is raised for spill containment.
Self-closing cabinets, required in some jurisdictions, have fusible links that melt at 165° F to close the doors.
OSHA regulations restrict storage of more than 60 gallons of flammables with a flash point below 100° F in a single cabinet.
Cabinets | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Max. No. of Drums per Cabinet | Shelves | Optional Ramp | |||||||||||||
Wd. | Ht. | Dp. | Cap., lbs. | 55-Gal. | 5-Gal. | Total No. of | Cap., lbs. | Ctr.-to-Ctr. Adjustments | Material | Color | Lock Type | Specifications Met | Each | Each | ||
With Hinged Doors—Assembled | ||||||||||||||||
31" | 65" | 31" | 1,300 | 1 | 1 | 1 | 500 | 2 1/2" | Steel | Yellow | Keyed | OSHA Compliant 29 CFR 1910.106, OSHA Compliant 29 CFR 1910.307, FM Approved, NFPA 30 | 00000000 | 000000000 | 0000000 | 0000000 |
56" | 65" | 31" | 1,300 | 2 | 2 | 1 | 500 | 2 1/2" | Steel | Yellow | Keyed | OSHA Compliant 29 CFR 1910.106, OSHA Compliant 29 CFR 1910.307, FM Approved, NFPA 30 | 00000000 | 00000000 | 0000000 | 000000 |
With Hinged Self-Closing Doors—Assembled | ||||||||||||||||
31" | 67" | 31" | 1,300 | 1 | 1 | 1 | 500 | 2 1/2" | Steel | Yellow | Keyed | OSHA Compliant 29 CFR 1910.106, OSHA Compliant 29 CFR 1910.307, FM Approved, NFPA 30 | 00000000 | 00000000 | 0000000 | 000000 |
56" | 67" | 31" | 1,300 | 2 | 2 | 1 | 500 | 2 1/2" | Steel | Yellow | Keyed | OSHA Compliant 29 CFR 1910.106, OSHA Compliant 29 CFR 1910.307, FM Approved, NFPA 30 | 00000000 | 00000000 | 0000000 | 000000 |
Safety Cabinets for Horizontal Storage of Flammables in 55-Gallon Drums

Store your drums horizontally to allow gravity-flow dispensing. The door sill is raised for spill containment. These cabinets have space for a drum stand and drip container (both not included).
The self-closing cabinet, required in some jurisdictions, has fusible links that melt at 165° F to close the doors.
OSHA regulations restrict storage of more than 60 gallons of flammables with a flash point below 100° F in a single cabinet.
Cabinets | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Optional Ramp | ||||||||||
Wd. | Ht. | Dp. | Max. No. of 55 Gal. Drums per Cabinet | Material | Color | Lock Type | Specifications Met | Each | Each | ||
With Hinged Doors—Assembled | |||||||||||
30" | 50" | 48" | 1 | Steel | Yellow | Keyed, Padlockable | OSHA Compliant 29 CFR 1910.106, NFPA 30 | 0000000 | 000000000 | 0000000 | 0000000 |
With Self-Closing Hinged Doors—Assembled | |||||||||||
30" | 50" | 48" | 1 | Steel | Yellow | Keyed, Padlockable | OSHA Compliant 29 CFR 1910.106, NFPA 30 | 0000000 | 00000000 | 0000000 | 000000 |
Replacement Keys (Pack of 2) | 0000000 | Pkg. | 000000 |
Outdoor Safety Cabinets for Flammables in 55-Gallon Drums

Keep your workplace safe and free up valuable floor space by storing drums outdoors. A secondary reservoir holds leaks from damaged drums and has removable grating for easy sump cleaning.
OSHA regulations restrict storage of more than 60 gallons of flammables with a flash point below 100° F in a single cabinet; do not exceed 120 gallons of any liquid with a flash point.
Overall | Mounting Holes | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wd. | Ht. | Dp. | Max. No. of 55 Gal. Drums per Cabinet | Spill Cap., gal. | Material | Color | Lock Type | Mounting Fasteners Included | No. of | Dia. | Specifications Met | Each | |
With Hinged Doors—Assembled | |||||||||||||
60" | 83" | 42" | 2 | 55 | Steel | Gray | Keyed | No | 4 | 7/8" | OSHA Compliant 29 CFR 1910.106, OSHA Compliant 29 CFR 1910.307, FM Approved, NFPA 30 | 0000000 | 000000000 |
60" | 83" | 60" | 4 | 68 | Steel | Gray | Keyed | No | 4 | 7/8" | OSHA Compliant 29 CFR 1910.106, OSHA Compliant 29 CFR 1910.307, FM Approved, NFPA 30 | 0000000 | 00000000 |
Spill-Control Sheds





Store hazardous liquids outside and away from people and workspaces. These sheds are made of polyethylene, so they resist most chemicals, including acids. Their roll-up doors offer access from the front or back to move containers, dispense liquids, and protect contents from the elements. All have two or more holes to secure with padlocks (not included).
For use with 55 gal. drums or 275 gal. IBC tanks, these sheds meet EPA 40 CFR 264.175 when used correctly. Choose a shed that’s large enough to hold either 10% of the total capacity of all the containers on it or the full capacity of the largest container—whichever is greater.
Sheds without a drain have fewer potential leak points, but they’re harder to empty after a spill. Sheds with a drain let you empty liquid after a spill without having to remove containers or pump liquids out through the top.
Sheds with a removable grating are easy to clean.
Sheds that hold two 275 gal. tanks have a single, continuous basin, so they can’t be separated into individual sheds.
Unassembled sheds are simple to put together—no fasteners required.
Add a bucket (sold separately) to catch spills and drips when dispensing from the tank. The bucket holds up to 3 gallons. When the bucket fills too high, excess liquid is released into the well of the shed.
Sheds | |||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Usable | Max. Fork | Buckets | ||||||||||||||||||||
For No. of 55-Gallon Drums | For No. of 275-Gallon Tanks | Spill Capacity, gal. | Overall Capacity, lbs. | Lg. | Wd. | Ht. | Lg. | Wd. | No. of Entry Points for Forklifts | Wd. | Ht. | Color | Lock Type | For Max. No. of Padlocks | For Max. Padlock Shackle Dia. | For Min. Padlock Shackle Lg. | Assembled or Unassembled | For Use Outdoors | Features | Each | Each | ||
Without Drain | |||||||||||||||||||||||
Polyethylene Plastic—Meets EPA 40 CFR 264.175 | |||||||||||||||||||||||
1 | __ | 70 | 800 | 36" | 36" | 66" | 26" | 26" | __ | __ | __ | Yellow | Padlockable | 3 | 5/16" | 2" | Assembled | Yes | Roll-Up Doors | 0000000 | 0000000 | 000000 | 00 |
2 | __ | 58 | 2,000 | 60" | 37 1/2" | 73" | 48" | 24" | 2 | 8" | 3 1/4" | Yellow | Padlockable | 2 | 7/16" | 4" | Unassembled | Yes | Removable Grating, Roll-Up Doors | 0000000 | 00000000 | 000000 | 00 |
4 | __ | 66 | 6,000 | 65" | 58" | 69" | 48" | 48" | 2 | 7 1/2" | 1 3/4" | Yellow | Padlockable | 2 | 7/16" | 5" | Unassembled | Yes | Removable Grating, Roll-Up Doors | 0000000 | 00000000 | 000000 | 00 |
__ | 1 | 369 | 5,000 | 65" | 65" | 101" | 48" | 48" | 2 | 8" | 3 1/4" | Yellow | Padlockable | 2 | 7/16" | 5 1/2" | Unassembled | Yes | Removable Grating, Roll-Up Doors | 0000000 | 00000000 | 000000 | 00 |
__ | 2 | 535 | 17,000 | 128" | 67" | 96" | 52" | 52" | 2 | 7 3/4" | 3 1/2" | Yellow | Padlockable | 4 | 5/16" | 1 1/2" | Assembled | Yes | Removable Grating, Roll-Up Doors | 0000000 | 00000000 | 00000000 | 0000000 |
With Drain | |||||||||||||||||||||||
Polyethylene Plastic—Meets EPA 40 CFR 264.175 | |||||||||||||||||||||||
1 | __ | 70 | 800 | 36" | 36" | 66" | 26" | 26" | __ | __ | __ | Yellow | Padlockable | 3 | 5/16" | 2" | Assembled | Yes | Roll-Up Doors | 0000000 | 000000 | 000000 | 00 |
2 | __ | 58 | 2,000 | 60" | 37 1/2" | 73" | 48" | 24" | 2 | 8" | 3 1/4" | Yellow | Padlockable | 2 | 7/16" | 4" | Unassembled | Yes | Removable Grating, Roll-Up Doors | 0000000 | 00000000 | 000000 | 00 |
4 | __ | 66 | 6,000 | 65" | 58" | 69" | 48" | 48" | 2 | 7 1/2" | 1 3/4" | Yellow | Padlockable | 2 | 7/16" | 5" | Unassembled | Yes | Removable Grating, Roll-Up Doors | 0000000 | 00000000 | 000000 | 00 |
__ | 1 | 369 | 5,000 | 65" | 65" | 101" | 48" | 48" | 2 | 8" | 3 1/4" | Yellow | Padlockable | 2 | 7/16" | 5 1/2" | Unassembled | Yes | Removable Grating, Roll-Up Doors | 0000000 | 00000000 | 000000 | 00 |
__ | 2 | 535 | 17,000 | 128" | 67" | 96" | 52" | 52" | 2 | 7 3/4" | 3 1/2" | Yellow | Padlockable | 4 | 5/16" | 1 1/2" | Assembled | Yes | Removable Grating, Roll-Up Doors | 0000000 | 00000000 | 00000000 | 000000 |