Blowers | Replacement Wheels | ||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting | ||||||||||||||||||||
Airflow @ SP | Volume (Sound) @ Distance | Motor Speed, rpm | Power, hp | Outlet Dia. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Wt., lb. | Current | Temp. Range, ° F | Housing Material | Fasteners Included | Hole Dia. | Each | Each | ||||
120V AC/230V AC | |||||||||||||||||||||
Single Phase—Hardwire | |||||||||||||||||||||
| 615 ft³/min @ 5 in. H₂O 845 ft³/min @ 3 in. H₂O | 65 dBA @ 15 ft. | 3,450 | 2 | 5 15/16" | 7" | 10 5/8" | 21 1/8" | 19 1/8" | 18 5/16" | 95 | 17.5 amp/8.7 amp | -10 to 150 | Steel | No | 7/16" | 1953K36 | 000000000 | 1953K104 | 0000000 | ||
230V AC/460V AC | |||||||||||||||||||||
Three Phase—Hardwire | |||||||||||||||||||||
| 615 ft³/min @ 5 in. H₂O 845 ft³/min @ 3 in. H₂O | 65 dBA @ 15 ft. | 3,450 | 2 | 5 15/16" | 7" | 10 5/8" | 21 1/8" | 19 1/8" | 17 7/8" | 87 | 4.9 amp/2.5 amp | -10 to 150 | Steel | No | 7/16" | 1953K37 | 00000000 | 1953K104 | 000000 | ||
High-Output Spark-Resistant Blowers
With Round Outlet and Round Inlet—Totally Enclosed Motor Enclosure
Overall | Mounting | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow @ SP | Volume (Sound) @ Distance | Motor Speed, rpm | Power, hp | Outlet Dia. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Wt., lb. | Current | Temp. Range, ° F | Housing Material | Fasteners Included | Hole Dia. | Each | |||
120V AC/230V AC | |||||||||||||||||||
Single Phase—Hardwire | |||||||||||||||||||
| 530 ft³/min @ 5 in. H₂O 685 ft³/min @ 3 in. H₂O | 80 dBA @ 15 ft. | 3,450 | 1 1/2 | 5" | 6" | 10 5/8" | 18" | 14 1/2" | 16 1/8" | 55 | 17.8 amp/8.9 amp | 0 to 100 | Aluminum | No | 7/16" | 1954K55 | 000000000 | ||
230V AC/460V AC | |||||||||||||||||||
Three Phase—Hardwire | |||||||||||||||||||
| 530 ft³/min @ 5 in. H₂O 685 ft³/min @ 3 in. H₂O | 80 dBA @ 15 ft. | 3,450 | 1 1/2 | 5" | 6" | 10 5/8" | 18" | 14 1/2" | 16 1/8" | 73 | 4.2 amp/2.1 amp | 0 to 100 | Aluminum | No | 7/16" | 1954K72 | 00000000 | ||
High-Output Hazardous Location Spark-Resistant Blowers
With Round Outlet and Round Inlet
Overall | Mounting | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow @ SP | Volume (Sound) @ Distance | Motor Speed, rpm | Power, hp | Outlet Dia. | Inlet Dia. | Wheel Dia. | Ht. | Wd. | Dp. | Wt., lb. | Current | Temp. Range, ° F | Housing Material | Hazardous Location Rating | Fasteners Included | Hole Dia. | Each | |||
120V AC/230V AC | ||||||||||||||||||||
Single Phase—Hardwire | ||||||||||||||||||||
| 530 ft³/min @ 5 in. H₂O 685 ft³/min @ 3 in. H₂O | 80 dBA @ 15 ft. | 3,450 | 1 1/2 | 5" | 6" | 10 5/8" | 18" | 14 1/2" | 16 1/8" | 88 | 15.0 amp/7.5 amp | 0 to 100 | Aluminum | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G | No | 7/16" | 1954K65 | 000000000 | ||
230V AC/460V AC | ||||||||||||||||||||
Three Phase—Hardwire | ||||||||||||||||||||
| 530 ft³/min @ 5 in. H₂O 685 ft³/min @ 3 in. H₂O | 80 dBA @ 15 ft. | 3,450 | 1 1/2 | 5" | 6" | 10 5/8" | 18" | 14 1/2" | 16 1/8" | 73 | 3.8 amp/1.9 amp | 0 to 100 | Aluminum | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G | No | 7/16" | 1954K73 | 00000000 | ||