    131 Products

    Square D Load-Center Circuit Breakers

    Match these circuit breakers to Square D breaker boxes or panel boards of the same manufacturer series. Because they are thermal-magnetic, these breakers trip two different ways. They either trip when heat is generated by sustained low-level overload current or quickly when the magnetic coil senses a high-current short circuit.
    QO Series
    Image of Product. QO Series, 2 Poles. Front orientation. Circuit Breakers. Square D Load-Center Circuit Breakers, QO Series, 2 Poles—Toggle Switch.

    QO Series,

    2 Poles

    UL 489—They meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    Mounting
    Location
    Wire Connection
    Method
    Wd.
    Specs.
    Met
    Certification
    Each
    2 Poles—Toggle Switch
    1548V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Breaker BoxSnap On1 1/2"UL 489UL Listed
    6782K212000000
    2048V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Breaker BoxSnap On1 1/2"UL 489UL Listed
    6782K21300000
    3048V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Breaker BoxSnap On1 1/2"UL 489UL Listed
    6782K21400000
    4048V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Breaker BoxSnap On1 1/2"UL 489UL Listed
    6782K21500000
    50 48V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Breaker BoxSnap On1 1/2"UL 489UL Listed
    6782K21600000
    6048V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Breaker BoxSnap On1 1/2"UL 489UL Listed
    6782K21700000
    7048V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Breaker BoxSnap On1 1/2"UL 489UL Listed
    6782K22000000
     
    QO Series with 6 mA Ground Fault Sensitivity
    Image of Product. QO Series, 2 Poles. Front orientation. Circuit Breakers. Square D Load-Center Circuit Breakers, QO Series, 2 Poles—Toggle Switch.

    QO Series,

    2 Poles

    Circuit breakers with ground fault sensitivity will trip if they detect a current leak above 6 mA. This minimizes the risk of electric shock to workers and equipment.
    UL 489—They meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage, V AC
    Freq., Hz
    Breakthrough Current @ Voltage
    Mounting
    Location
    Wire Connection
    Method
    Wd.
    Specs.
    Met
    Certification
    Each
    2 Poles—Toggle Switch
    20120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On1.5"UL 489UL Listed
    6782K3040000000
    30120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On1.5"UL 489UL Listed
    6782K305000000
     
    QOB Series
    Image of Product. QOB Series, 2 Poles. Front orientation. Circuit Breakers. Square D Load-Center Circuit Breakers, QOB Series, 2 Poles—Toggle Switch.

    QOB

    Series, 2

    Poles

    UL 489—They meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    Mounting
    Location
    Wire Connection
    Wd.
    Specs.
    Met
    Certification
    Each
    2 Poles—Toggle Switch
    1548V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Panel BoardScrew-Clamp Terminal1 1/2"UL 489UL Listed
    6782K611000000
    2048V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Panel BoardScrew-Clamp Terminal1 1/2"UL 489UL Listed
    6782K61200000
    3048V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Panel BoardScrew-Clamp Terminal1 1/2"UL 489UL Listed
    6782K61300000
    4048V DC
    120V AC
    240V AC
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    5,000 amp @ 48V DC
    Panel BoardScrew-Clamp Terminal1 1/2"UL 489UL Listed
    6782K31100000
     
    Homeline Series
    Image of Product. Homeline Series, 3 Poles. Front orientation. Circuit Breakers. Square D Load-Center Circuit Breakers, Homeline Series, 2 Poles—Toggle Switch.

    Homeline

    Series, 3

    Poles

    UL 489—They meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage, V AC
    Freq., Hz
    Breakthrough Current @ Voltage
    Mounting
    Location
    Wire Connection
    Method
    Wd.
    Specs.
    Met
    Certification
    Each
    2 Poles—Toggle Switch
    15120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On2"UL 489UL Listed
    69225K92000000
    20120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On2"UL 489UL Listed
    69225K7500000
    30120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On2"UL 489UL Listed
    69225K7600000
    40120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On2"UL 489UL Listed
    69225K7700000
    50 120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On2"UL 489UL Listed
    69225K10200000
    60120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On2"UL 489UL Listed
    69225K10300000
     
    Homeline Series with 6 mA Ground Fault Sensitivity
    Image of Product. Homeline Series, 3 Poles. Front orientation. Circuit Breakers. Square D Load-Center Circuit Breakers, Homeline Series, 2 Poles—Toggle Switch.

    Homeline

    Series, 3

    Poles

    Circuit breakers with ground fault sensitivity will trip if they detect a current leak above 6 mA. This minimizes the risk of electric shock to workers and equipment.
    UL 489—They meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage, V AC
    Freq., Hz
    Breakthrough Current @ Voltage
    Mounting
    Location
    Wire Connection
    Method
    Wd.
    Specs.
    Met
    Certification
    Each
    2 Poles—Toggle Switch
    20120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On2"UL 489UL Listed
    69225K1040000000
    30120
    240
    50/6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxSnap On2"UL 489UL Listed
    69225K105000000
     

    DIN-Rail Mount Equipment Circuit Breakers

    Image of ProductInUse. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers.
    Image of Product. Auxiliary Contact. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers.
    Image of Product. Distribution Bar. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers.
    Image of Product. Distribution Bar Terminal Cover. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers.

    Auxiliary

    Contact

    Distribution Bar

    Distribution Bar

    Terminal Cover

    Image of Product. Distribution Bar End Cover. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers.
    Image of Product. Shunt Trip. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers.
    Image of Product. Extension Terminal. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers.

    Distribution

    Bar End Cover

    Shunt

    Trip

    Extension

    Terminal

    Distribution bars simplify wiring by powering multiple adjacent circuit breakers without needing separate wires for each one. This cuts down on assembly time and space. Cut them to the number of terminals that you need.
    Distribution bar terminal covers shield unused, live terminals on distribution bars to prevent injury and damage.
    Auxiliary contacts send a signal to other equipment when the circuit trips. They can activate a warning light, initiate a shutdown, or start a backup power source.
    Shunt trips receive a signal from equipment to trip your circuit breaker in situations other than overload or short circuit conditions. For example, use them with a smoke detector to shut off power to a system in the event of a fire.
    Extension terminals raise the wire connection point above distribution bars for easy access to connect power to a set of circuit breakers.
    Also known as supplemental protectors, these circuit breakers mount directly to DIN rail downstream from a branch circuit breaker to protect a single piece of equipment. Because they are thermal-magnetic, these breakers trip two ways. They either trip when heat is generated slowly by consistent low-level overload current, or they trip quickly when the magnetic coil senses a high-current short circuit.
    Distribution bar end covers seal the live ends of distribution bars to prevent injury and damage.
    B Trip
    Image of Product. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers, 2 Poles—Toggle-Switch Style.

    2

    Poles—Toggle-Switch

    Style

    B-trip circuit breakers are best for protecting sensitive equipment, such as programmable logic controllers (PLCs) and sensors, which could be damaged by a spike in current. These circuit breakers will trip if a rush of current reaches 3 to 5 times their rated current.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    For DIN
    Rail Size, mm
    Mounting
    Location
    Wire Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Specs. Met
    Certification
    Each
    2 Poles—Toggle-Switch Style
     
    Thermal/Magnetic
    196V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K6160000000
    596V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K617000000
    1096V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K618000000
    1596V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K619000000
    2096V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K681000000
    3096V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K621000000
     
    Accessories for Circuit Breakers
    C Trip
    Image of Product. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers, 2 Poles—Toggle-Switch Style.

    2

    Poles—Toggle-Switch

    Style

    C-trip circuit breakers are the most common. They’re best for applications such as lighting and control panels, where equipment startup causes a moderate spike in current. They won’t trip until a rush of current reaches 5 to 10 times their rated current.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    For DIN
    Rail Size, mm
    Mounting
    Location
    Wire Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Specs. Met
    Certification
    Each
    2 Poles—Toggle-Switch Style
     
    Thermal/Magnetic
    196V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K6330000000
    296V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K634000000
    396V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K635000000
    496V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K636000000
    596V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K71000000
    696V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K637000000
    896V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K638000000
    1096V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K72000000
    1596V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K73000000
    2096V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K74000000
    2596V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K639000000
    3096V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K911000000
    4096V DC
    277V AC
    480YV AC/277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 480V AC
    5,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K683000000
    50 96V DC
    277V AC
    480YV AC/277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 480V AC
    5,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K641000000
     
    Accessories for Circuit Breakers
    D Trip
    Image of Product. Front orientation. Circuit Breakers. DIN-Rail Mount Equipment Circuit Breakers, 2 Poles—Toggle-Switch Style.

    2

    Poles—Toggle-Switch

    Style

    D-trip circuit breakers prevent nuisance tripping, so they are best for equipment that has a high spike in current at startup, such as transformers, power supplies, and heaters. They will not trip unless a rush of current reaches 10 to 20 times their rated current.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    For DIN
    Rail Size, mm
    Mounting
    Location
    Wire Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Specs. Met
    Certification
    Each
    2 Poles—Toggle-Switch Style
     
    Thermal/Magnetic
    196V DC
    277V AC
    480YV AC/277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 480V AC
    5,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K6560000000
    296V DC
    277V AC
    480YV AC/277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 480V AC
    5,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K411000000
    396V DC
    277V AC
    480YV AC/277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 480V AC
    5,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K412000000
    496V DC
    277V AC
    480YV AC/277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 480V AC
    5,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K657000000
    596V DC
    277V AC
    480YV AC/277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 480V AC
    5,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K413000000
    696V DC
    277V AC
    480YV AC/277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 480V AC
    5,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K658000000
    896V DC
    277V AC
    480YV AC/277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 480V AC
    5,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K659000000
    1096V DC
    277V AC
    480YV AC/277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 480V AC
    5,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K414000000
    1596V DC
    277V AC
    480YV AC/277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 480V AC
    5,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K415000000
    2096V DC
    277V AC
    480YV AC/277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 480V AC
    5,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K416000000
    2596V DC
    277V AC
    480YV AC/277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 480V AC
    5,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K685000000
    3096V DC
    277V AC
    480YV AC/277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 480V AC
    5,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K661000000
    4096V DC
    277V AC
    480YV AC/277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 480V AC
    5,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K417000000
    50 96V DC
    277V AC
    480YV AC/277V AC
    50/605,000 amp @ 277V AC
    5,000 amp @ 480V AC
    5,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal3.15"1.4"2.36"-40 to 165UL 1077, IEC 60947-2UL Listed, CSA Certified, CE Marked
    7026K662000000
     
    Accessories for Circuit Breakers

    Siemens Load-Center Circuit Breakers

    Image of Product. Front orientation. Circuit Breakers. Siemens Load-Center Circuit Breakers, 2 Poles—Toggle-Switch Style.

    2

    Poles—Toggle-Switch

    Style

    Use with Siemens EQ series breaker boxes. Because they are thermal-magnetic, these circuit breakers trip two different ways. They either trip when heat is generated slowly by consistent low-level overload current or quickly when the magnetic coil senses a high-current short circuit.
    UL 489—These circuit breakers meet UL 489 requirements for branch circuit protection, so they protect downstream equipment and wiring from overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage, V AC
    Freq.,
    Hz
    Breakthrough Current @ Voltage
    Mounting
    Location
    Wire Connection
    Wd.
    Specs.
    Met
    Each
    2 Poles—Toggle-Switch Style
     
    Thermal/Magnetic
    15120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal2"UL 4895259T51000000
    20120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal2"UL 4895259T5200000
    30120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal2"UL 4895259T5300000
    40120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal2"UL 4895259T5400000
    50 120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal2"UL 4895259T5500000
    60120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal2"UL 4895259T5600000
    70120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal2"UL 4895259T600000
     

    DIN-Rail Mount Branch Circuit Breakers

    Image of ProductInUse. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers.
    Image of Product. Extension Terminal. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers.
    Image of Product. Distribution Bar Terminal Cover. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers.
    Image of Product. Shunt Trip. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers.

    Extension

    Terminal

    Distribution

    Bar Terminal

    Cover

    Shunt

    Trip

    Image of Product. Auxiliary Contact. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers.
    Image of Product. Distribution Bar. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers.

    Auxiliary

    Contact

    Distribution Bar

    Distribution bar terminal covers shield unused, live terminals on distribution bars to prevent injury and damage.
    Auxiliary contacts send a signal to other equipment when the circuit trips. They can activate a warning light, initiate a shutdown, or start a backup power source.
    Shunt trips receive a signal from equipment to trip your circuit breaker in situations other than overload or short circuit conditions. For example, use them with a smoke detector to shut off power to a system in the event of a fire.
    Extension terminals raise the wire connection point above distribution bars for easy access to connect power to a set of circuit breakers.
    Mount these circuit breakers directly to DIN rail to protect equipment and wiring in an area of your facility from overloads and short circuits. Because they are thermal-magnetic, these breakers trip two ways. They either trip when heat is generated slowly by consistent low-level overload current, or they trip quickly when the magnetic coil senses a high-current short circuit.
    Distribution bars simplify wiring by powering multiple adjacent circuit breakers without needing separate wires for each one. This cuts down on assembly time and space.
    B Trip
    Image of Product. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers, 2 Poles—Toggle-Switch Style.

    2

    Poles—Toggle-Switch

    Style

    B-trip circuit breakers are best for protecting sensitive equipment, such as programmable logic controllers (PLCs) and sensors, which could be damaged by a spike in current. These circuit breakers will trip if a rush of current reaches 3 to 5 times their rated current.
    UL 489—They meet UL 489 requirements for branch circuit protection and are certified as current limiting, so they protect equipment by minimizing passing current during a short circuit.
    Voltage
    Freq., Hz
    For DIN
    Rail Size, mm
    Wire Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Specs. Met
    Certification
    Choose a Current, A
    Each
    2 Poles—Toggle-Switch Style
    96V DC
    277V AC
    480YV AC/277V AC
    50/6035Screw-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    1
    ,
    5
    ,
    10
    ,
    15
    ,
    20
    ,
    30
    5789T202000000
     
    Accessories for Circuit Breakers
    C Trip
    Image of Product. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers, 2 Poles—Toggle-Switch Style.

    2

    Poles—Toggle-Switch

    Style

    C-trip circuit breakers are the most common. They’re best for applications such as lighting and control panels, where equipment startup causes a moderate spike in current. They won’t trip until a rush of current reaches 5 to 10 times their rated current.
    UL 489—They meet UL 489 requirements for branch circuit protection and are certified as current limiting, so they protect equipment by minimizing passing current during a short circuit.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    For DIN
    Rail Size, mm
    Mounting
    Location
    Wire Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Specs. Met
    Certification
    Choose a Current,
    A
    Each
    2 Poles—Toggle-Switch Style
     
    Thermal/Magnetic
    96V DC
    240V AC
    50/6010,000 amp @ 240V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    35
    ,
    40
    ,
    50
    ,
    63
    5789T206000000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    1/25789T11500000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    15789T11600000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    1 1/25789T11700000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    25789T11800000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    35789T11900000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    45789T12100000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    55789T8100000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    65789T12200000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    75789T12300000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    85789T12400000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    105789T8200000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    135789T12500000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    305789T8500000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    325789T12800000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6014,000 amp @ 277V AC
    14,000 amp @ 480V AC
    14,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    155789T8300000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6014,000 amp @ 277V AC
    14,000 amp @ 480V AC
    14,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    165789T12600000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6014,000 amp @ 277V AC
    14,000 amp @ 480V AC
    14,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    205789T8400000
    96V DC
    277V AC
    480YV AC/277V AC
    50/6014,000 amp @ 277V AC
    14,000 amp @ 480V AC
    14,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    255789T12700000
    250V DC
    125V DC
    50/6010,000 amp @ 125V DC
    10,000 amp @ 250V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    2
    ,
    5
    ,
    10
    ,
    15
    ,
    20
    5789T20500000
     
    Accessories for Circuit Breakers
    D Trip
    Image of Product. Front orientation. Circuit Breakers. DIN-Rail Mount Branch Circuit Breakers, 2 Poles—Toggle-Switch Style.

    2

    Poles—Toggle-Switch

    Style

    D-trip circuit breakers prevent nuisance tripping, so they are best for equipment that has a high spike in current at startup, such as transformers, power supplies, and heaters. They will not trip unless a rush of current reaches 10 to 20 times their rated current.
    UL 489—They meet UL 489 requirements for branch circuit protection and are certified as current limiting, so they protect equipment by minimizing passing current during a short circuit.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    For DIN
    Rail Size, mm
    Mounting
    Location
    Wire Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Specs. Met
    Certification
    Each
    2 Poles—Toggle-Switch Style
     
    Thermal/Magnetic
    196V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T444000000
    296V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T51100000
    396V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T51200000
    496V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T44500000
    596V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T51300000
    696V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T44600000
    896V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T44700000
    1096V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T51400000
    1596V DC
    277V AC
    480YV AC/277V AC
    50/6014,000 amp @ 277V AC
    14,000 amp @ 480V AC
    14,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T51500000
    2096V DC
    277V AC
    480YV AC/277V AC
    50/6014,000 amp @ 277V AC
    14,000 amp @ 480V AC
    14,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T51600000
    2596V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T44800000
    3096V DC
    277V AC
    480YV AC/277V AC
    50/6010,000 amp @ 277V AC
    10,000 amp @ 480V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T51700000
    4096V DC
    240V AC
    50/6010,000 amp @ 240V AC
    10,000 amp @ 96V DC
    35DIN RailScrew-Clamp Terminal4.13"1.4"2.36"-10 to 165UL 489, IEC 60947-2CSA Certified, CE Marked
    5789T44900000
     
    Accessories for Circuit Breakers

    Cutler-Hammer Load-Center Circuit Breakers

    Image of Product. Front orientation. Circuit Breakers. Cutler-Hammer Load-Center Circuit Breakers, 2 Poles—Toggle-Switch Style.

    2

    Poles—Toggle-Switch

    Style

    Install these circuit breakers into Cutler-Hammer CH series breaker boxes. Because these circuit breakers are thermal-magnetic, they trip two different ways. They either trip when heat is generated slowly by consistent low-level overload current or quickly when the magnetic coil senses a high-current short circuit.
    UL 489—They meet UL 489 requirements for branch circuit protection and are certified as current limiting, so they protect equipment by minimizing passing current during a short circuit.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage, V AC
    Freq.,
    Hz
    Breakthrough Current @ Voltage
    Mounting
    Location
    Wire Connection
    Wd.
    Specs.
    Met
    Each
    2 Poles—Toggle-Switch Style
     
    Thermal/Magnetic
    15120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal1 1/2"UL 4895259T81000000
    20120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal1 1/2"UL 4895259T8200000
    30120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal1 1/2"UL 4895259T8300000
    40120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal1 1/2"UL 4895259T8400000
    50 120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal1 1/2"UL 4895259T8500000
    60120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal1 1/2"UL 4895259T8600000
    70120
    240
    6010,000 amp @ 120V AC
    10,000 amp @ 240V AC
    Breaker BoxScrew-Clamp Terminal1 1/2"UL 4895259T900000
     

    High-Temperature Panel-Mount Circuit Breakers

    Image of Product. Front orientation. Circuit Breakers. High-Temperature Panel-Mount Circuit Breakers , 2 Poles—Toggle-Switch Style.

    2

    Poles—Toggle-Switch

    Style

    Unlike breakers that trip thermally, these breakers have a hydraulic-magnetic trip mechanism, so they aren’t affected by changes in temperature. Instead, these circuit breakers trip when they hydraulically sense consistent low-level overload current, or they trip quickly when the magnetic coil senses a high-current short circuit. Use the threaded holes on the face to install them through panels, enclosure covers, or walls to keep them close to the equipment they protect.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    For Panel
    Cutout
    Mounting
    Holes
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    Temp. Range,
    ° F
    Ht.
    Wd.
    Dia.
    Dp. Behind
    Panel
    No.
    of
    Thread
    Size
    Mounting Fasteners
    Included
    Wire Connection
    Ht.
    Wd.
    Each
    2 Poles—Toggle-Switch Style
    580V DC
    277V AC
    50/605,000 amp @ 277V AC
    7,500 amp @ 80V DC
    -40 to 1850.63"2"46-32
    NoQuick-Disconnect Terminal2"1.5"72015K51000000
    1080V DC
    277V AC
    50/605,000 amp @ 277V AC
    7,500 amp @ 80V DC
    -40 to 1850.63"2"46-32
    NoQuick-Disconnect Terminal2"1.5"72015K5200000
    15250V AC50/601,500 amp @ 250V AC-40 to 1851.45"1.52"2.573"46-32
    NoScrew Terminal2.5"1.5"72015K41000000
    20250V AC50/601,500 amp @ 250V AC-40 to 1851.45"1.52"2.573"46-32
    NoScrew Terminal2.5"1.5"72015K42000000
     

    DIN-Rail Mount Ground Fault Circuit Protectors

    Image of ProductInUse. Front orientation. Circuit Breakers. DIN-Rail Mount Ground Fault Circuit Protectors, 2 Poles—Toggle-Switch Style.

    2 Poles—Toggle-Switch

    Style

    Add ground fault protection to a circuit to minimize the risk of electric shock to workers and equipment if there is a current leak. These protectors will trip if they detect a current leak above 30 mA. However, they do not protect against overloads. Pair them with a circuit breaker to fully protect a circuit. Commonly used in electrical enclosures, these protectors mount directly to DIN rail.
    UL 1053—These protectors meet strict UL 1053 standards for ground fault detecting devices.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    Current,
    A
    Voltage, V AC
    Freq., Hz
    Breakthrough Current @ Voltage
    Ground Fault
    Sensitivity, mA
    For DIN
    Rail Size, mm
    Mounting
    Location
    Wire Connection
    Ht.
    Wd.
    Dp.
    Temp. Range,
    ° F
    Specs. Met
    Certification
    Each
    2 Poles—Toggle-Switch Style
    25120
    208YV AC/120V AC
    50/605,000 amp @ 120V AC
    5,000 amp @ 208V AC
    3035DIN RailScrew-Clamp Terminal3.15"1.38"2.36"-10 to 100UL 1053, IEC 61008UL Listed, CE Marked
    4418N110000000
    40120
    208YV AC/120V AC
    50/605,000 amp @ 120V AC
    5,000 amp @ 208V AC
    3035DIN RailScrew-Clamp Terminal3.15"1.38"2.36"-10 to 100UL 1053, IEC 61008UL Listed, CE Marked
    4418N12000000
    63120
    208YV AC/120V AC
    50/605,000 amp @ 120V AC
    5,000 amp @ 208V AC
    3035DIN RailScrew-Clamp Terminal3.15"1.38"2.36"-10 to 100UL 1053, IEC 61008UL Listed, CE Marked
    4418N13000000
     

    Panel-Mount Equipment Circuit Breakers

    Mount these breakers, also known as supplemental protectors, through panels downstream from a branch circuit breaker to protect a single piece of equipment. These breakers can also be used as on/off switches. All are thermal, so they use the heat generated in overcurrent situations to trip the breaker.
    Push-Button Style—Screw-On Mount
    Image of Product. Front orientation. Circuit Breakers. Panel-Mount Equipment Circuit Breakers, Push Button Manual Reset.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    For Panel
    Cutout
    Mounting
    Holes
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    Ht.
    Wd.
    Dp. Behind
    Panel
    No.
    of
    Dia.
    Mounting Fasteners
    Included
    Quick-Disconnect
    Tab Wd.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    2 Poles
    560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T51000000
    1060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T5200000
    1560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T5300000
    2060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.98"0.99"1.96"20.15"No0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T5400000
     
    Circuit Breaker Covers
    Rocker-Switch Style—Snap-In Mount
    Image of Product. Front orientation. Circuit Breakers. Panel-Mount Equipment Circuit Breakers, Rocker Switch Manual Reset.
    UL 1077—They are rated UL 1077 for protection against overloads and short circuits.
    Breakthrough Current @ Voltage—Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
    For Panel
    Cutout
    Current,
    A
    Voltage
    Freq., Hz
    Breakthrough Current @ Voltage
    Ht.
    Wd.
    Dp. Behind
    Panel
    Quick-Disconnect
    Tab Wd.
    Temp. Range,
    ° F
    Specs.
    Met
    Certification
    Each
    2 Poles
    560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T21000000
    1060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T2200000
    1560V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T2300000
    2060V DC
    240V AC
    50/601,000 amp @ 240V AC
    1,000 amp @ 60V DC
    1.77"0.85"1 3/4"0.25"15 to 130UL 1077UL Recognized Component, CSA Certified
    3931T2400000
     