McMaster-Carr logo
    Filter by
    American Wire Gauge (AWG)
    Industrial Info Snippet
    Attribute Image
    Number of Wires
    Attribute Image
    System of Measurement
    Wire Construction
    Industrial Info Compare
    NEMA Type
    Industrial Info Compare
    Wire Material
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Industrial Info Compare
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    29 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Power Cable

    Image of Product. Front orientation. Power Cable.
    Built for rough handling and frequent positioning, this cable delivers power you can count on. Use it for everything from extension cords to cords for hydraulic presses. Made to NEC Article 400 requirements, you can trust it to power whatever you need. Plus, the flexible jacket takes the struggle out of routing it through tight spaces and around machinery.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-249
    250-Up
    300V AC
     
    SJTW Cable
    12/3
    25 amp @ 86° FPVC
    Orange-40 to 165UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507394K130000000000
     
    SJEOOW Cable
    12/3
    25 amp @ 86° FTPE
    Black-40 to 220UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507082K2400000000
    12/3
    25 amp @ 86° FTPE
    Yellow-55 to 220UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508046K1600000000
     
    SJOOW Cable
    12/3
    25 amp @ 86° FEPDM
    Black-40 to 190UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507422K2600000000
     
    600V AC
     
    STOW Cable
    12/3
    25 amp @ 86° FPVC
    Yellow-40 to 165UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508201K4600000000
     
    SEOOW Cable
    12/3
    25 amp @ 86° FTPE
    Black-40 to 220UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507080K4400000000
    12/3
    25 amp @ 86° FTPE
    Yellow-75 to 220UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507080K2400000000
     
    SOOW Cable
    12/3
    25 amp @ 86° FEPDM
    Black-40 to 190UL 2556 FT2
    CSA Certified, UL Listed
    10, 25, 50, 100, 2507081K2400000000
    12/3
    25 amp @ 86° FEPDM
    Yellow-55 to 220UL 2556 FT1
    CSA Certified, UL Listed
    10, 25, 50, 100, 2508041K5800000000
     

    Armored Building Cable

    Also known as metal clad (MC) cable, this cable has metal armor that acts as conduit to protect the building wires. It's often used along the exterior of walls to carry power to outlet boxes. It has a ground wire that is not counted in the number of wires.
    Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
    MC, THHN Solid Wire
    Image of Product. Front orientation. Building Cable. Armored Building Cable , THHN Cable.
    Cable with THHN wire stands up to condensation and moisture in basements and other damp environments.
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Material
    Material
    Color
    Temp. Range,
    ° F
    Features
    Hazardous Location Rating
    Specs.
    Met
    Flammability
    Rating
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    600V AC
    12
    312/3
    20 amp @ 86° F0.51"Aluminum
    PVC
    Black, Green, Red, White15 to 190Insulated Ground WireNEC Class I Division 2 Groups A, B, C, D
    NEC Class II Division 2 Groups F, G
    NEC Class III Divisions 1, 2
    UL 1569UL 2556 VW-1
    6730T25000000000000000000000000000000000
     

    Continuous-Flex Control Cable

    Image of Product. Front orientation. Control Cable. Continuous-Flex Control Cable, Unshielded.

    Unshielded

    Even after millions of flex cycles, this cable transmits reliable signals. Its finely stranded conductors are twisted together like a rope to resist wear from constant bending. Use it in moving equipment such as cable carriers.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability Rating
    Certification
    Clean Room
    Std.
    Choose a Length, ft.
    1-99
    100-Up
    300V AC
     
    Unshielded
    12/3
    37 amp @ 86° F2.93"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    ISO Class 1
    5, 10, 20, 30, 50, 100, 2505106N390000000000
     
    600V AC
     
    Unshielded
    12/3
    30 amp @ 86° F3.38"PVC
    Black45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    5, 10, 20, 30, 50, 1009204K84000000000
     

    Harsh-Environment Power Cable

    Image of Product. Front orientation. Power Cable. Harsh-Environment Power Cable, Type P Cable.

    Type P Cable

    Image of Product. Front orientation. Power Cable. Harsh-Environment Power Cable, Type P Cable with Bronze Armor.

    Type P Cable with Bronze Armor

    Transmit power in dirty, corrosive environments such as offshore rigs and ships. This cable is strong enough to resist crushing forces from heavy equipment. Its CPE jacket and tin-plated copper conductors maintain power in areas exposed to chemicals, oil, and salt water. It meets UL 1309 for high-performance marine cables, yet works just as well on land.
    Bronze Armor—A layer of bronze armor between the two outer jackets boosts resistance to abrasion, impact, and crushing.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Specs.
    Met
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Type P Cable
    12/3
    25 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K180000000000
     
    Type P Cable with Bronze Armor
    12/3
    25 amp @ 86° FCPEBlack-40 to 230UL 1309ABS Type Approved, CSA Certified, UL Listed
    10, 25, 50, 1008248K4800000000
     

    VFD Motor Cable

    This cable is used in variable-frequency drive motors. It has a layer of braid and foil shielding that provides excellent protection against signal interference caused by voltage fluctuations and current spikes. The industry designation is WTTC, so it can be installed in cable trays or raceway in a wind turbine generator. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray. The insulation resists oil.
    Power Wire— Stranded with Cross-Linked Polyethylene Outer Jacket
    Image of Product. With Three Uninsulated Ground Wires. Side1 orientation. VFD Motor Cable. Power Wire— Stranded with Cross-Linked Polyethylene Outer Jacket, Three Uninsulated Ground Wires.

    With Three Uninsulated Ground

    Wires

    Cable with power wires sends electricity to run a motor.
    Three Uninsulated Ground Wires—Cable with three uninsulated ground wires pairs a ground wire with each power wire, so you can create multiple circuits from the same cable. These wires aren’t counted in the cable’s number of wires.
    Power
    Wire
    Inner
    Insulation
    No.
    of
    AWG
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Features
    5 ft.
    Long
    10 ft.
    Long
    20 ft.
    Long
    30 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    Double Shielded—1,000V AC/1,000V DC
    312
    12/3
    30 amp @ 86° F0.57"BlackPolyethyleneBlack, White-40 to 220WTTC
    Three Uninsulated Ground Wires7777T320000000000000000000000000000000000000000
     

    No-Conduit-Required Control Cable

    Image of Product. Front orientation. Control Cable. No-Conduit-Required Control Cable, Unshielded.

    Unshielded

    Made to TC-ER (Tray Cable, Exposed Run) standards, this crush- and impact-resistant cable eliminates the cost and hassle of installing conduit. It’s ideal for exposed runs, such as from a cable tray down to a control panel or motor control box. Support it every six feet to prevent sagging. You can flex and bend this cable during installation and adjustments, but it isn't made for continuous motion.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Cable
    Designation
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Unshielded
    12/3
    20 amp @ 86° FPVC
    BlackTC-ER
    -10 to 190UL 2556 FT4
    C-UL Listed, CSA Certified, UL Listed
    10, 20, 30, 50, 1006452T810000000000
     

    Submersible Pump Cable

    Image of Product. Side1 orientation. Submersible Pump Cable.
    Supply power to submersible pumps in water or oil wells. The TPE insulation holds up to moisture, chemicals, oil, and UV light, so this cable can be used outdoors. Also known as twisted pump cable, it can be used in grounded or ungrounded water well cable systems. The insulated ground wire is not counted in the number of wires.
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket Color
    Temp. Range,
    ° F
    Features
    Cable
    Designation
    Certification
    Specs.
    Met
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    Stranded Wire with TPE Outer Jacket
     
    600V AC
    12
    312/3
    20 amp @ 86° F0.46"Black, Green, Red, Yellow-55 to 140Insulated Ground WireTHWUL Listed
    UL 836237N22000000000000000000000000000
     

    High-Temperature Power Cable

    Image of Product. Front orientation. Power Cable. High-Temperature Power Cable, Unshielded.

    Unshielded

    When others can't take the heat, this cable delivers power in ovens, furnaces, steel mills, and foundries. The PTFE jacket won't degrade and weaken as temperatures rise. It also resists abrasion, chemicals, oil, and moisture.
    Fiberglass Fabric over PTFE and Mica Tape—A layer of mica tape, naturally heat resistant and electrically insulating, delivers superior protection against high temperatures.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @ Temp.
    Material
    Color
    Temp.,
    ° F
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Unshielded
    12/3
    56 amp @ 86° F
    23 amp @ 700° F
    Fiberglass Fabric over PTFE and Mica TapeBlack-40 to 8405, 10, 20, 509464T19000000000000
     

    Coiled Power Cable

    Image of Product. Front orientation. Power Cable. Coiled Power Cable.
    Extend to full length for added reach, then watch this cable retract and self-coil for convenience. It's often used with hand tools, pendant switches, and other portable devices.
    Outer
    Jacket
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Certification
    Extends from 2
    ft. to 10 ft. Long
    Extends from 4
    ft. to 20 ft. Long
    Extends from 6
    ft. to 30 ft. Long
    Extends from 8
    ft. to 40 ft. Long
    600V AC
     
    SEOW Cable
    12/3
    25 amp @ 86° FTPE
    Black0 to 175CSA Certified, UL Listed
    7520K28000000000000000000000000000
     
    SOW Cable
    12/3
    20 amp @ 86° FNeoprene
    Black-40 to 190CSA Certified, UL Listed
    7088K228000000000000
     

    Building Cable

    Image of Product. Front orientation. Building Cable. Building Cable , NM-B Cable, THHN Cable.
    Image of Product. Front orientation. Building Cable. Building Cable , THHN Cable, UF-B Cable.

    THHN Cable

    NM-B Cable

    UF-B Cable

    THHN Cable

    Rated for in-wall installation, this cable carries power to wall outlets. Also known as branch circuit wire, it can be used without conduit. It has solid THHN building wires, so the cable will stay in the shape you bend it. The uninsulated ground wire is not counted in the number of wires.
    NM-B Cable—NM-B cable is for dry locations where moisture is not a concern, and often run through walls, ceilings, and concrete blocks.
    UF-B Cable—UF-B cable is for wet locations where cable may be exposed to moisture or humidity. It's often used as underground feeder cable for pumps and lighting. The insulation resists moisture and UV light.
    Outer
    Jacket
    Inner
    Insulation
    Per Ft.
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    Wd.
    Thk.
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Features
    Certification
    Specs.
    Met
    Choose a Length, ft.
    1-249
    250-Up
    NM-B, THHN Solid Wire
     
    600V AC
    12
    312/3
    20 amp @ 86° F0.52"0.19"PVC
    PurplePVC
    Black, Red, White10 to 190Uninsulated Ground WireUL Listed
    UL 71910, 25, 50, 100, 25069935K650000000000
     
    UF-B, THHN Solid Wire
     
    600V AC
    12
    312/3
    20 amp @ 86° F0.63"0.18"PVC
    GrayPVC
    Black, Red, White10 to 190Uninsulated Ground WireUL Listed
    UL 49310, 25, 50, 100, 2507116K9600000000
     

    Control Cable

    Image of Product. Front orientation. Control Cable. Unshielded.

    Unshielded

    Control, monitor, and regulate stationary equipment such as sensors and PLCs. You can flex and bend this cable during installation and adjustments, but it isn't made for continuous motion.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Unshielded
    12/3
    30 amp @ 86° FPVC
    Gray45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10, 20, 30, 50, 1009936K360000000000
     

    Turn-Lock Power Cords

    Image of Product. Front orientation. Power Cords. Turn-Lock Power Cords.
    The curved blades lock into place with a quarter turn. These cords won’t disconnect when bumped or pulled, so they’re often used in high-vibration applications, such as on assembly lines or with heavy machinery.
    Outer
    Jacket
    Lg.,
    ft.
    Voltage,
    V AC
    Current,
    amp
    AWG
    Cable
    Designation
    Material
    Color
    Certification
    Each
    NEMA L5-20 Plug × Wire Leads
    81252012
    SJT
    PVC
    BlackC-UL Listed, UL Listed
    70355K103000000
    121252012
    SJT
    PVC
    BlackC-UL Listed, UL Listed
    6674N1100000
     
    NEMA L6-20 Plug × Wire Leads
    82502012
    SJT
    PVC
    BlackC-UL Listed, UL Listed
    70355K10400000
     

    Pendant Cable

    Often used to wire pendant switches, this cable hangs from an overhead connection. It’s also known as bus drop cable.
    Stranded Wire with Three Uninsulated Ground Wires
    Image of Product. Front orientation. Pendant Cable. Stranded Wire with Three Uninsulated Ground Wires.
    Cable with three uninsulated ground wires can be used in wet environments. The ground wires are not counted in the number of wires.
    PVC Inner Insulation—The PVC insulation resists abrasion, chemicals, and oil.
    Inner
    Insulation
    Per Ft.
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Color
    Material
    Color
    Temp.,
    ° F
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
    12
    312/3
    25 amp @ 86° F0.42"GrayPVC
    Black, Red, White-40 to 140UL Listed
    10, 25, 50, 100, 2507128K110000000000
     

    Armored Building Cable with Fittings

    Image of Product. Front orientation. Building Cable. Armored Building Cable with Fittings .
    Also known as fixture whips, this cable has locknuts and fittings attached to the metal armor to secure to a knockout. The armor acts as conduit to protect the THHN building wires. It has 6" long wire leads for hardwiring to an existing electrical system, and is often used to connect light fixtures.
    Inner
    Insulation
    6 ft. Long
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Material
    Material
    Color
    Temp. Range,
    ° F
    Includes
    Certification
    Each
    THHN Stranded Wire
     
    600V AC
    12
    312/3
    20 amp @ 86° F0.52"SteelPVC
    Black, Green, White-10 to 1901/2 NPT Fittings, Locknuts, 6" Wire LeadsUL Listed
    9340T11000000
     

    Armored Building Cable with Uninsulated Ground Wire

    Image of Product. Front orientation. Building Cable. Armored Building Cable with Uninsulated Ground Wire.
    Also known as AC cable, this cable has an uninsulated aluminum ground wire that's in constant contact with the aluminum armor, so it can be used for bonding and grounding. The uninsulated ground wire is not counted in the number of wires. The armor acts as conduit to protect the THHN building wires. It's often used along the exterior of walls to carry power to outlet boxes. All are flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    Current @
    Temp.
    OD
    Outer Jacket
    Material
    Material
    Color
    Temp. Range,
    ° F
    Features
    Certification
    Flammability
    Rating
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    AC, THHN Solid Wire
     
    600V AC
    12
    312/3
    20 amp @ 86° F0.52"Aluminum
    PVC
    Black, Red, White15 to 190Uninsulated Ground WireUL Listed
    UL 2556 VW-1
    6755T45000000000000000000000000000000000
     
    back to top