McMaster-Carr logo
    Filter by
    Number of Wires
    Attribute Image
    American Wire Gauge (AWG)
    Industrial Info Snippet
    Attribute Image
    Wire Construction
    Industrial Info Compare
    System of Measurement
    Inner Insulation Color
    Outer Jacket Material
    Shield Type
    Inner Insulation Material
    Signal Type
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    16 Products
    About Wire and Cable
    industrial info icon

    Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.

    Continuous-Flex Control Cable

    Image of Product. Front orientation. Control Cable. Continuous-Flex Control Cable, Unshielded.
    Image of Product. Front orientation. Control Cable. Continuous-Flex Control Cable, Shielded.

    Unshielded

    Shielded

    Even after millions of flex cycles, this cable transmits reliable signals. Its finely stranded conductors are twisted together like a rope to resist wear from constant bending. Use it in moving equipment such as cable carriers.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability Rating
    Certification
    Clean Room
    Std.
    Choose a Length, ft.
    1-99
    100-Up
    300V AC
     
    Unshielded
    20/2
    10 amp @ 86° F1.65"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    C-UL Recognized Component, CE Marked, UL Recognized Component
    ISO Class 1
    5
    ,
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    ,
    250
    5106N210000000000
     
    600V AC
     
    Unshielded
    20/2
    10 amp @ 86° F1.63"PVC
    Green25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5
    ,
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    ,
    250
    4514N1400000000
     
    Shielded
    20/2
    8 amp @ 86° F1.9"PVC
    Green25 to 155UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    ISO Class 2
    5
    ,
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    ,
    250
    4514N3500000000
     

    Control Cable

    Image of Product. Front orientation. Control Cable. Unshielded.

    Unshielded

    Image of Product. Front orientation. Control Cable. Shielded.

    Shielded

    Control, monitor, and regulate stationary equipment such as sensors and PLCs. You can flex and bend this cable during installation and adjustments, but it isn't made for continuous motion.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Unshielded
    20/2
    6 amp @ 86° FPVC
    Gray45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    ,
    250
    9936K830000000000
     
    Shielded
    20/2
    6 amp @ 86° FPVC
    Gray45 to 190UL 2556 VW-1
    CSA Certified, UL Recognized Component
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    9936K7300000000
     

    Abrasion-Resistant Power Cable

    Image of Product. Front orientation. Power Cable. Abrasion-Resistant Power Cable, Unshielded.

    Unshielded

    Pull this cable over rough surfaces without damage. The thick polyurethane jacket protects the wires inside and resists wear. It also stands up to moisture, oil, and chemicals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    300V AC
     
    Unshielded
    20/2
    5.6 amp @ 86° FPolyurethane Rubber
    Black-20 to 190UL 2556 VW-1
    C-UL Recognized Component, UL Recognized Component
    5
    ,
    10
    ,
    25
    ,
    50
    ,
    100
    8237K230000000000
     

    Industrial CAN-Bus Cable

    Image of Product. Front orientation. CAN-Bus Cable. Industrial CAN-Bus Cable.
    Connect devices such as sensors, PLCs, and actuators to a CAN-Bus network.
    Use this continuous-flex cable in automated applications that require continuous motion, such as robotics. This double shielded cable has a layer of braid and foil shielding for better protection against signal interference than foil alone. Use it in environments with high signal distortion, such as near transformers, generators, and heavy duty motors.
    This flame-rated cable meets requirements for preventing the spread of flames based on a timed test. VW-1 cable is suspended vertically during testing.
    PVC Outer Jacket—Choose cable with PVC outer jacket for general purpose indoor applications. Its protective layer resists abrasion, though it contains halogen. It’s also less flexible than cable with TPE jacket.
    TPE Outer Jacket—Cable with TPE outer jacket has a protective layer that is more flexible and resists abrasion better than other materials. It also stands up to extreme temperatures and chemicals, making it good for use in harsh outdoor environments.
    Outer
    Jacket
    Per Ft.
    Transmission
    Speed, Mbit/s
    AWG (No.
    of Wires)
    Temp. Range,
    ° F
    OD
    Material
    Color
    Flammability
    Rating
    Choose a Length, ft.
    1-99
    100-Up
    Continuous Flex
     
    Double-Shielded Stranded Wire
    120 (2)-30 to 1550.31"TPE
    PurpleUL 2556 VW-1
    10
    ,
    25
    ,
    50
    ,
    100
    ,
    250
    8097T220000000000
    120 (2)45 to 1550.33"PVC
    PurpleUL 2556 VW-1
    10
    ,
    25
    ,
    50
    ,
    100
    ,
    250
    8097T2700000000
     

    Vehicle Cable

    Image of Product. Front orientation. Vehicle Cable.
    Also known as GPT cable, this cable is often used in low-voltage applications such as battery and vehicle wiring and radios. It has one red wire and one black wire to easily identify polarity. The wires can be pulled apart for installation.
    Outer
    Jacket
    Per Ft.
    AWG
    No. of
    Wires
    Cable
    AWG
    Wd.
    Thk.
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Choose a Length, ft.
    1-249
    250-Up
    Stranded Wire
     
    12V DC
    20
    220/2
    0.17"0.08"PVC
    Black, Red-40 to 175GPT
    25
    ,
    50
    ,
    100
    ,
    250
    ,
    500
    9697T720000000000
     

    No-Conduit-Required Continuous-Flex Control Cable

    Image of Product. Front orientation. Control Cable. No-Conduit-Required Continuous-Flex Control Cable, Unshielded.

    Unshielded

    Image of Product. Front orientation. Control Cable. No-Conduit-Required Continuous-Flex Control Cable, Shielded.

    Shielded

    Eliminate the need for conduit and cable splices. Made to TC-ER (Tray Cable, Exposed Run) standards, this cable resists impact and crushing force. You can run a single length from stationary equipment to and through moving equipment, such as cable carriers. Support it every six feet to prevent sagging. Even after millions of flex cycles, this cable transmits reliable signals. Its finely stranded conductors are twisted together like a rope, strengthening the cable and preventing fatigue from constant bending.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Cable
    Designation
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Unshielded
    20/2
    8 amp @ 86° F2.16"PVC
    GrayTC-ER
    25 to 175UL 2556 FT4
    CSA Certified, UL Listed
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    9700T610000000000
     
    Shielded
    20/2
    8 amp @ 86° F3.5"PVC
    GrayTC-ER
    25 to 175UL 2556 FT4
    CSA Certified, UL Listed
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    9700T7500000000
     

    High-Temperature Power Cable

    Image of Product. Front orientation. Power Cable. High-Temperature Power Cable, Shielded.

    Shielded

    When others can't take the heat, this cable delivers power in ovens, furnaces, steel mills, and foundries. The PTFE jacket won't degrade and weaken as temperatures rise. It also resists abrasion, chemicals, oil, and moisture.
    Shielded—Shielding stops these cables from acting as antennas that emit electromagnetic interference, which could disrupt nearby equipment such as control or data cables.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @ Temp.
    Material
    Color
    Temp.,
    ° F
    Mil. Spec.
    Choose a Length, ft.
    1-99
    100-Up
    600V AC
     
    Shielded
    20/2
    8.2 amp @ 86° F
    4 amp @ 300° F
    PTFE
    White-65 to 390MIL-W-16878/4 Type E
    10
    ,
    20
    ,
    50
    ,
    100
    8219K570000000000
     

    Twisted-Pair Continuous-Flex Control Cable

    Image of Product. Front orientation. Control Cable. Twisted-Pair Continuous-Flex Control Cable.
    Prevent mixed messages in control systems such as sensors and PLCs. The twisted-pair wires in this cable prevent internal and external signal interference, even in electrically noisy areas. Designed for the demands of continuous motion, this cable transmits signals for millions of flex cycles. Its finely stranded conductors are twisted together like a rope to resist wear from constant bending.
    Shielded—A single layer of shielding protects sensitive electronics and control systems by blocking electromagnetic interference (EMI). Otherwise, equipment such as motors and pumps could distort signals.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability Rating
    Certification
    Clean Room
    Std.
    Choose a Length, ft.
    1-99
    100-Up
    300V AC
     
    Shielded
    20/2
    1.8"PVC
    Gray25 to 155NFPA 79, UL 2556 VW-1
    CE Marked
    ISO Class 1
    10
    ,
    25
    ,
    50
    ,
    100
    2099T6410000000000
     

    Space-Saving Continuous-Flex Control Cable

    Image of Product. Front orientation. Control Cable. Space-Saving Continuous-Flex Control Cable.
    Cut congestion in crowded cable carriers that are always moving. This cable is one-third the diameter of other control cables of the same gauge, letting you fit more into the same footprint. Its slim profile comes from mPPE (modified polyphenylene ether) insulation, which is nearly half the weight of other insulation materials. Its finely stranded conductors are twisted together like a rope to resist wear from constant bending. The rugged jacket protects the cable from wear and tear and exposure to chemicals, oil, and moisture. Altogether, this cable endures millions of flex cycles while maintaining reliable signals.
    Unshielded—Choose unshielded wires when electromagnetic interference (EMI) isn't a concern. Equipment such as motors and pumps may have voltage fluctuations and current spikes that distort signals.
    Outer
    Jacket
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    600V AC
     
    Unshielded
    20/2
    5.6 amp @ 86° F1"Polyurethane Rubber
    Gray-40 to 175CSA Certified, UL Recognized Component
    6650T51
    000000
    000000
    0000000
    0000000
     

    Thermostat Cable

    Image of Product. Front orientation. Thermostat Cable.
    Hook up thermostats, air-conditioning units, and other low-voltage equipment. This cable is designated CL2 so it has flame-resistant insulation. The wires are solid so it stays in the shape you bend it.
    Outer
    Jacket
    Inner
    Insulation
    AWG
    No. of
    Wires
    Cable
    AWG
    OD
    Material
    Color
    Material
    Color
    Temp. Range,
    ° F
    Cable
    Designation
    Certification
    10 ft.
    Long
    25 ft.
    Long
    50 ft.
    Long
    100 ft.
    Long
    250 ft.
    Long
    Solid Wire
     
    150V AC/150V DC
    20
    220/2
    0.11"PVC
    BrownPolyethyleneRed, White0 to 140CL2
    ETL Listed
    8278T11
    00000
    000000
    000000
    000000
    000000
     

    High-Voltage Continuous-Flex Flat Power Cable

    Image of Product. Front orientation. Power Cable. High-Voltage Continuous-Flex Flat Power Cable.
    For high-voltage systems with constant motion, this cable flexes without breaking. Its thick silicone rubber jacket insulates against high voltage and resists chemicals, oil, moisture, and UV rays. The jacket also has a low-smoke, zero-halogen (LSZH) design to prevent toxic emissions if there’s a fire.
    Outer
    Jacket
    Per Ft.
    Cable
    AWG
    Current @
    Temp.
    Bend
    Radius
    Material
    Color
    Temp.,
    ° F
    Flammability
    Rating
    Certification
    Clean Room Std.
    Choose a Length, ft.
    1-99
    100-Up
    25,000V AC/18,000V DC
     
    Unshielded
    20/2
    13 amp @ 86° F1.2"Silicone Rubber
    Clear-85 to 325UL 94 V-0
    CSA Certified, UL Recognized Component
    Fed. Std. Class 1, ISO Class 3
    10
    ,
    20
    ,
    30
    ,
    50
    ,
    100
    9634T5010000000000
     