About Wire and Cable
More
High-Voltage Continuous-Flex Flat Cable
- Use For: Automation, Continuous Motion
- Continuous Flex
- Temperature Range: -85° to 325° F
- Insulation: Silicone Rubber
A thick outer layer of silicone rubber insulation protects this cable from high voltages while remaining ultra flexible. You'll often see this cable used in harsh environments with tight turns, from robotics and aerospace to oil rigging, because it won't break down from chemicals, oil, moisture, or UV light. It stands up to continuous motion without degrading data or signal transmission.
This cable meets UL 94 V-0 for flame retardance. If it is exposed to flames, it minimizes how much smoke and halogen it releases. It also meets clean room standards because it releases minimal particles into the air.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
Per Ft. | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Bend Radius | Outer Insulation Color | Performance Properties | Environment | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | |||||||||||||||
12,000V DC/17,000V AC | |||||||||||||||
24 | 8 | 24/8 | 8 A @ 86° F | 0.5" | 0.09" | 1" | Clear | Low Smoke/Zero Halogen | Clean Room | Fed. Std. Class 1, ISO Class 3 | UL Recognized Component, CSA Certified, UL 94 V-0 | 00000000 | 00000 | 00000 |
Servomotor Continuous-Flex Cable
- Use For: Automation, Continuous Motion, Interference Shielding, Motors
- Continuous Flex
- Temperature Range: -40° to 175° F
- Insulation:
Outer: Polyurethane Rubber
Inner: Polypropylene Plastic
Connect servocontrollers and servomotors in automated equipment and on assembly lines. This cable withstands continuous motion without degrading data or signal transmission. The polyurethane rubber insulation resists abrasion and oil. It’s flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Cable with signal wires is also known as feedback cable. It sends and receives signals between a servomotor and a PLC.
Shielded cable has a layer of braid that blocks signal interference from nearby equipment and devices.
Bend radius is the point to which the cable will bend without being damaged. It is measured from the center of the bend to the edge of the cable. The smaller the measurement, the tighter the bend.
No. of Wires | Wire Ga. | Cable AWG | Current | OD | Bend Radius | Outer Insulation Color | Inner Insulation Color | Specifications Met | 5 ft. | 10 ft. | 20 ft. | 30 ft. | 50 ft. | |
Shielded—30V AC/45V DC | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
8 | 24 | 24/8 | 1.4 A @ 86° F | 0.29" | 1.87" | Green | Blue, Brown, Gray, Green, Pink, Red, White, Yellow | UL Recognized Component, UL 2556 VW-1 | 0000000 |
Ethernet Cable
- Use For:
Unshielded: Data; Category 3 can also be used for Telephones
Shielded, Double Shielded: Data, Interference Shielding - Flexible
- Insulation:
Outer: PVC Plastic
Inner: See table
Send data between computers, printers, servers, and switches. Ethernet category standards describe the cable’s performance capabilities. Higher category numbers mean faster speeds, superior data transfer, and better signal strength. Category cables are backward compatible, so you can mix and match, but your speed will only be as fast as the lowest-rated cable.
Unshielded cable is the choice for day-to-day wiring, such as connecting your desktop computer to an ethernet port.
CM and CMR cable prevent the spread of flames down the length of the cable. CMR is more flame resistant than CM cable.
Inner Insulation | Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ethernet Cable Category | Transmission Frequency | Wire Ga. | No. of Wires | Cable AWG | Max. Temp., °F | OD | Industry Designation | Material | Color | Choose an Outer Insulation Color | Length, ft. | 1-499 | 500-Up | |
Unshielded Solid Wire | ||||||||||||||
3 | 16 MHz | 24 | 8 | 24/8 | 140° | 0.16" | CMR | PVC Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | Gray | 000000 | 00000 | 00000 | |
5E | 100 MHz | 24 | 8 | 24/8 | 165° | 0.21" | CM | Polyolefin Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | 0000000 | 000 | 000 |
Duct-Rated Ethernet Cable
- Use For:
Unshielded: Data
Shielded: Data, Interference Shielding - Flexible
- Insulation:
Outer: PVC Plastic
Inner: See table
Also known as plenum cable, this CMP cable has flame-resistant, low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. Use it to send data between computers, printers, servers, and switches in an office. It’s backward compatible so it works in networks that meet the same or a lower category. Choose cable with a higher ethernet cable category for a clearer signal.
Use unshielded cable in applications where signal interference is not a concern.
Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ethernet Cable Category | Transmission Frequency | Wire Ga. | No. of Wires | Cable AWG | Max. Temp., °F | OD | Inner Insulation Material | Inner Insulation Color | Choose an Outer Insulation Color | Length, ft. | 1-499 | 500-Up | |
Unshielded Solid Wire | |||||||||||||
5E | 350 MHz | 24 | 8 | 24/8 | 165° | 0.21" | FEP/Polyolefin Plastic Blend | Blue, Brown, Green, Orange, White/Blue, White/Brown, White/Green, White/Orange | 0000000 | 00000 | 00000 |
Oil-Resistant Ethernet Cable
- Use For:
Unshielded: Data
Shielded: Data, Interference Shielding - Flexible
- Max. Temperature: 165° F
- Insulation:
Inner Insulation: See table
Outer Insulation: PVC Plastic
From mines and factories to robotics, this rugged Ethernet cable sends data between sensors and switches in the grimiest places. The PVC outer insulation is treated to stand up to oil and coolants where typical PVC insulation would become brittle and crack. To make sure it doesn't kink and snap, this cable was tested under repeated bending and rubbing with little signs of wear. Higher numbers for the Ethernet category standard mean faster speeds, superior data transfer, and better signal strength. Category cables are backward compatible, so you can mix and match. However, your speed will only be as fast as the lowest-rated cable.
Choose unshielded cable for most applications. When working with variable frequency drives or small motors, choose shielded cable, which has a layer of foil that protects from signal interference. It has an uninsulated ground wire that is not counted in the number of wires.
Inner Insulation | Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Ethernet Cable Category | Transmission Frequency | Wire Ga. | No. of Wires | Cable AWG | OD | Material | Color | Outer Insulation Color | Features | Length, ft. | 1-99 | 100-Up | |
Unshielded Solid Wire | |||||||||||||
5E | 350 MHz | 24 | 8 | 24/8 | 0.23" | Polyolefin Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | Black | __ | 000000 | 00000 | 00000 | |
Shielded Solid Wire | |||||||||||||
5E | 100 MHz | 24 | 8 | 24/8 | 0.27" | Polyolefin Plastic | Blue Blue/White Brown Brown/White Green Green/White Orange Orange/White | Black | Uninsulated Ground Wire | 000000 | 0000 | 0000 |
Duct-Rated Oil-Resistant Ethernet Cable
- Use For: Data
- Flexible
- Max. Temperature: 300° F
- Insulation: FEP Plastic
Also known as plenum cable, this cable is designated CMP, so it has low-smoke insulation and can be used without conduit in duct work and above a drop ceiling. The oil-resistant FEP insulation protects wires as the cable moves from duct to equipment or machinery. It also resists UV light. It’s backward compatible so it works in networks that meet the same or a lower category.
Continuous-Flex Data Communication Cable
- Use For: Automation, Continuous Motion, Data, Interference Shielding
- Continuous Flex
- Temperature Range:
PVC Plastic Insulation: 25° to 155° F
TPE Rubber Insulation: -30° to 210° F
Often used to send signal and data to order pickers and cranes, this cable withstands continuous motion applications without degrading data or signal transmission. In addition to a layer of braid shielding, it has twisted pairs of wires that cancel signal interference from multiple transmission lines. Suitable for clean rooms, it releases minimal particles into the air. It is CE marked as compliant with European health, safety, and environmental standards.
Cable with PVC insulation is for indoor use.
Cable with TPE rubber insulation is for outdoor use and resists coolant, oil, and UV light.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | OD | Bend Radius | Outer Insulation Color | Environmental Rating | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Shielded Stranded Wire with PVC Plastic Insulation | |||||||||||
300V AC | |||||||||||
24 | 8 | 24/8 | 0.31" | 2.33" | Gray | ISO Class 1 | CE Marked, UL 2556 VW-1, NFPA 79 | 0000000 | 00000 | 00000 | |
Shielded Stranded Wire with TPE Rubber Insulation | |||||||||||
300V AC | |||||||||||
24 | 8 | 24/8 | 0.35" | 2.24" | Blue | ISO Class 1 | CE Marked | 0000000 | 00000 | 0000 |
Data Communication Cable
- Use For: Data, Interference Shielding
- Flexible
- Outer Insulation: PVC Plastic
Connect computers, CNC machines, and other equipment that requires complex data and signal transmission. This double-shielded cable has both braid and foil for the highest level of protection against signal interference. Use it in areas with high signal distortion, such as near transformers, generators, and motors. This CM-designated cable is flame rated for general purpose applications, such as in-wall installation or use between equipment on shop floors. It’s also rated VW-1 to keep fire from spreading. This cable has an uninsulated ground wire that is not counted in the number of wires.
Per Ft. | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Transmission Speed, Mbps | Capacitance per Foot | Temp. Range, °F | OD | Industry Designation | Outer Insulation Color | Inner Insulation Color | Features | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Double-Shielded Stranded Wire | |||||||||||||||
300V AC | |||||||||||||||
24 | 8 | 24/8 | 10 | 12.5 pF | 0° to 165° | 0.28" | CM | Gray | Black, Blue, Brown, Green, Orange, Red, White, Yellow | Uninsulated Ground Wire | NEC Article 800, UL 2556 VW-1 | 00000000 | 00000 | 00000 |
Communication and Security System Cable
Often used for intercoms, speakers, and security systems, this cable is designated as CM and CL2 or CMG, so the insulation is flame resistant and approved for in-wall installation in single-level facilities.
Shielded cable has a layer of foil that blocks signal interference from nearby equipment and devices. It has an uninsulated ground wire is not counted in the number of wires.
- Use For: Buildings, Interference Shielding
- Flexible
- Temperature Range: See table
- Insulation: PVC Plastic
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Temp. Range, °F | OD | Outer Insulation Color | Inner Insulation Color | Features | Industry Designation | Length, ft. | 1-99 | 100-Up | |
300V AC/300V DC | ||||||||||||
24 | 8 | 24/8 | 0° to 175° | 0.22" | Gray | Black, Blue, Brown, Green, Orange, Red, White, Yellow | Uninsulated Ground Wire | CM, CMG | 00000000 | 00000 | 00000 |