Filter by
System of Measurement
Wire Construction
Cable Designation
Shielding
Flexibility
Inner Insulation Material
Current @ Temperature
Outer Jacket Color
Wire Material
Environment
Finish
Inner Insulation Color
Hazardous Location Rating
Export Control Classification Number (ECCN)
DFARS Specialty Metals
REACH
About Wire and Cable
Compare wire vs. cable and choose the right option based on gauge, number of conductors, insulation, and current rating.
Armored Building Cable
MC, XHHW-2 Stranded Wire
Inner Insulation | |||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AWG | No. of Wires | Cable AWG | Current @ Temp. | OD | Outer Jacket Material | Material | Color | Temp. Range, ° F | Features | Hazardous Location Rating | Specs. Met | 10 ft. Long | 25 ft. Long | 50 ft. Long | 100 ft. Long | 250 ft. Long | |||
600V AC/600V DC | |||||||||||||||||||
| 14 | 3 | 14/3 | 15 amp @ 86° F | 0.64" | Aluminum, PVC | Cross-Linked Polyethylene | Black | -40 to 190 | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 6730T31 | 000000 | 000000 | 0000000 | 0000000 | 0000000 | ||
| 12 | 3 | 12/3 | 20 amp @ 86° F | 0.65" | Aluminum, PVC | Cross-Linked Polyethylene | Black | -40 to 190 | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 6730T32 | 00000 | 00000 | 000000 | — | 000000 | ||
| 12 | 4 | 12/4 | 20 amp @ 86° F | 0.68" | Aluminum, PVC | Cross-Linked Polyethylene | Black | -40 to 190 | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 6730T33 | 00000 | 00000 | 000000 | 000000 | 000000 | ||
| 10 | 3 | 10/3 | 30 amp @ 86° F | 0.7" | Aluminum, PVC | Cross-Linked Polyethylene | Black | -40 to 190 | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 6730T34 | 00000 | 000000 | 000000 | 000000 | 000000 | ||
| 10 | 4 | 10/4 | 30 amp @ 86° F | 0.74" | Aluminum, PVC | Cross-Linked Polyethylene | Black | -40 to 190 | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 6730T35 | 00000 | 000000 | 000000 | 000000 | 000000 | ||
Building Wire
Stranded Wire with Polyethylene Outer Jacket
AWG | Wire Strand Count | Current @ Temp. | OD | Temp. Range, ° F | Outer Jacket Color | Cable Designation | Certification | 25 ft. Long | 50 ft. Long | 100 ft. Long | 250 ft. Long | 500 ft. Long | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
600V AC/600V DC | |||||||||||||||
| 14 | 7/22 | 15 amp @ 86° F | 0.14" | -40 to 190 | Black | XHHW-2 | UL Listed, CSA Certified | 7715T1 | 000000 | 000000 | 000000 | 0000000 | 0000000 | ||
| 12 | 7/20 | 20 amp @ 86° F | 0.16" | -40 to 190 | Black | XHHW-2 | UL Listed, CSA Certified | 7715T2 | 00000 | 00000 | 00000 | 000000 | 000000 | ||
| 10 | 7/18 | 30 amp @ 86° F | 0.18" | -40 to 190 | Black | XHHW-2 | UL Listed, CSA Certified | 7715T3 | 00000 | 00000 | 00000 | 000000 | 000000 | ||
| 8 | 7/16 | 55 amp @ 86° F | 0.24" | -40 to 190 | Black | XHHW-2 | UL Listed, CSA Certified | 7715T4 | 00000 | 00000 | 000000 | 000000 | 000000 | ||
600V AC/1,000V DC | |||||||||||||||
| 6 | 7/14 | 75 amp @ 86° F | 0.27" | -40 to 190 | Black | XHHW-2 | C-UL Listed, UL Listed | 7715T5 | 00000 | 00000 | 000000 | 000000 | 000000 | ||
| 4 | 7/12 | 95 amp @ 86° F | 0.32" | -40 to 190 | Black | XHHW-2 | C-UL Listed, UL Listed | 7715T7 | 00000 | 000000 | 000000 | 000000 | 000000 | ||